CORROSION INHIBITORS IN CONCRETE

Similar documents
Doç. Dr. Halit YAZICI. D. E. U. Civil Engineering Department.

Reed, Hale 1. Slag Cement Concrete for Use in Bridge Decks. August 1, Words (6 Tables = 1500 words)

Surface Resistivity as a Performance Test for Transport Properties

Fundamentals of Concrete

SULFATE AND CHLORIDE RESISTANCE PROPERTIES OF PORTLAND CEMENT BLENDS

Admixtures-Section 924

MEASURING THE EFFECTIVENESS OF MIGRATING CORROSION INHIBITORS (MCIs) BY ELECTROCHEMICAL TECHNIQUES

FINAL REPORT EVALUATION OF CORROSION INHIBITORS FOR CONCRETE BRIDGE DECK PATCHES AND OVERLAYS. Michael M. Sprinkel, P.E. Associate Director

Migrating Corrosion Inhibitors to Protect Reinforced Concrete Structures

IS : Dr. S. RAVIRAJ

High-Performance Concrete

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

Prediction of Chloride Permeability of High Performance Concrete

Experimental Case Study Demonstrating Advantages of Performance Specifications Karthik Obla 1 Fernando Rodriguez 2 and Soliman Ben Barka 3

Experimental Case Study Demonstrating Advantages of Performance Specifications

CHAPTER 3 MATERIAL PROPERTIES AND MIX PROPORTIONS

EFFECT OF CHLORIDE CONCENTRATION IN SOIL ON REINFORCEMENT CORROSION

NRMCA is working on. Experimental Case Study Demonstrates Advantages of Performance Specifications

DURABILITY of CONCRETE STRUCTURES

Chloride Corrosion Threshold Dependence on Steel Potential in Reinforced Concrete

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

CORROSION MONITORING IN REINFORCED CONCRETE BY ACOUSTIC EMISSION

Specifying Concrete for Durability Performance-Based Criteria Offer Best Solutions Karthik Obla, Colin Lobo, Lionel Lemay NRMCA

INTEGRALLY COLORED CONCRETE [DECORATIVE CONCRETE PAVING]

Effect of silica fume on the corrosion performance of reinforcements in concrete

Standard Specification for Admixtures to Inhibit Chloride-Induced Corrosion of Reinforcing Steel in Concrete 1

Fundamental study on the effectiveness of nitrite for polymer-cement mortar

EVALUATION OF DURABILITY OF ODOT PRESTRESSED/PRECAST CONCRETE IN OHIO

COMPUTATION OF CORROSION DISTRIBUTION OF REINFORCING STEEL IN CRACKED CONCRETE

PERFORMANCE OF ADMIXTURES INTENDED TO RESIST CORROSION IN CONCRETE EXPOSED TO A MARINE ENVIRONMENT

PERFORMANCE EVALUATION OF CORROSION INHIBITORS AND GALVANIZED STEEL IN CONCRETE EXPOSURE SPECIMENS

Laboratory Assessment of Drying Shrinkage of Concretes Containing Shrinkage Reducing Agents Compared with a New Low shrinkage Concrete

Chloride-induced reinforcement corrosion in blended cement concretes expores to chloride-sulfate environments

Corrosion Protection for Concrete Structures in Marine Environments. D.B.McDonald, Ph.D., P.E, FACI

Effects of Materials and Mixing Procedures on Air Void Characteristics of Fresh Concrete

Performance-based Specifications State of the Industry and Way Forward

Chapter VI Mix Design of Concrete

Mixture Design for Durability. Dr. Peter Taylor

SECTION 706 AGGREGATES FOR PORTLAND CEMENT PRODUCTS SCOPE

Pumice Pozz vs. Fly Ash

Effects of Cement Type and Fly Ash on the Sulfate Attack Using ASTM C 1012

Sensitivity of Resistivity Measurements on Concrete Bridge Decks to Operator-Controlled and Concrete Material Variables

Sensitivity of Resistivity Measurements on Concrete Bridge Decks to Operator-Controlled and Concrete Material Variables

Protecting Concrete Structures Against Corrosion Damage. David McDonald, Ph.D., P.E., FACI, Epoxy Interest Group of CRSI

Effect of Polypropylene Fibers on Durability Characteristics of No-Aggregate Concrete

Journal of Engineering Sciences, Assiut University, Vol. 34, No. 4, pp , July 2006

Evaluation of Corrosion Inhibitors

ORGANOFUNCTIONAL SILANE CORROSION INHIBITOR SURFACE TREATMENT OF CONCRETE TO MITIGATE CORROSION DUE TO CHLORIDES OR CARBONATION ABSTRACT

PERFORMANCE OF CORROSION INHIBITING ADMIXTURES IN HAWAIIAN CONCRETE IN A MARINE ENVIRONMENT. FINAL PROJECT REPORT by

STUDY OF MIX DESIGN FOR HIGH PERFORMANCE CONCRETE

APPLICATION OF SELF-CONSOLIDATING CONCRETE FOR BRIDGE REPAIR

MICHIGAN CONCRETE ASSOCIATION GUIDE FOR COLD WEATHER CONCRETING

Experimental Investigation to Study Effect of Polyester Fibre on Durability of HVFA Concrete through RCPT Method

PERFORMANCE-RELATED SPECIAL PROVISION FOR HIGH PERFORMANCE CONCRETE MIX DESIGNS FOR CONCRETE SUPERSTRUCTURE (Tollway)

CORROSION DEVELOPMENT OF POST TENSIONED TENDONS WITH DEFICIENT GROUT

CALCIUM NITRATE MIXED CEMENT MORTAR FOR REPAIRING CORRODED RC STRUCTURES. University of Ruhuna, Sri Lanka

Study of High Performance Concrete with Silica Fume and Glass Fibre

Study and Analysis of High Performance Concrete and Estimation of Concrete Strength

CONSIDERATIONS ON THE THRESHOLD CHLORIDE CONTENT VALUES ON THE CORROSION OF STEEL BARS IN CONCRETE

The Effect of Cement Type on Behavior of Reinforced Concrete against Attack Sulfate Salt

Overlays. HCC Deck Overlays. Key Decisions for Concrete Deck Overlays

MITIGATING ALKALI SILICA REACTIVITY (ASR) WITH FLY ASH

ULTRA-HIGH STRENGTH SHEAR KEY GROUT

What Is Concrete Mix Design?

Effect of silica fume on the resistance to chloride ion penetration in high performance concrete

INVESTIGATION INTO THE USE OF MICROSILICA AND FLY ASH IN SELF COMPACTING CONCRETE

Comparison of Properties of Fresh and Hardened Concrete Containing Finely Ground Glass Powder, Fly Ash, or Silica Fume

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

Durability Predictions Using Early-Age Durability Index Testing

Tolerances- Section

CARBONATION-INDUCED CORROSION OF BLENDED-CEMENT CONCRETE MIX DESIGNS FOR HIGHWAY STRUCTURES

Truck Mixer, Agitator and Front Discharge Concrete Carrier. Standards. TMMB Printing

Influence of Organic Inhibitor on the Corrosion Potential of Steel in Concrete

IN THE APPLICATION INVENTOR(S) ABUL KALAM AZAD AND IBRAHIM YAHYA AHMED HAKEEM FOR ULTRA-HIGH PERFORMANCE CONCRETE REINFORCEMENT BARS

Research Article The Effect of Accelerators and Mix Constituents on the High Early Strength Concrete Properties

Durability Performance of Australian Commercial Concrete Modified with Permeability Reducing Admixture

Efficiency of an amine-ester based corrosion inhibitor for concrete

The durability of normal strength concrete: an experimental study

Alkali Aggregate Reactions

September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE

research report Virginia Transportation Research Council Final Report VTRC 10-R11 D. STEPHEN LANE Associate Principal Research Scientist

Research Article Experimental and Empirical Time to Corrosion of Reinforced Concrete Structures under Different Curing Conditions

6.4.1 Concrete mix design. The four concrete mixes were designed using the absolute volume method as shown below:

Evaluation of Processed Bottom Ash for Use as Lightweight Aggregate in the Production of Concrete Masonry Units

Concrete Pipe in Acid Sulfate Soil Conditions

ALKALI-SILICA REACTION (ASR)

INVESTIGATION OF THE CHEMICAL ADMIXTURE INFLUENCE ON THE PERFORMANCE OF SELF COMPACTING CONCRETE

PART 1 - GENERAL. Section Cast-in-Place Concrete 1.3 REFERENCES

Techniques to Assess the Corrosion Activity of Steel Reinforced Concrete Structures

DIVISION II CONSTRUCTION AND MATERIAL SPECIFICATIONS SECTION 2700 STRUCTURES

Evaluation of Processed Bottom Ash for Use as Lightweight Aggregate in the Production of Concrete Masonry Units

Dusit Roongsang, P.E. Presented at. PNWS AWWA Conference Bellevue, WA May 1, 2015

CHAPTER 4 DURABILITY STUDIES ON PMMFRHPC

EFFECT OF CORROSION INHIBITOR ON PROPERTIES OF CONCRETE AND MORTAR MADE WITH DIFFERENT ADMIXTURES

FINAL REPORT EVALUATION OF HYDRAULIC CEMENT CONCRETE OVERLAYS PLACED ON THREE PAVEMENTS IN VIRGINIA. Michael M. Sprinkel, P.E.

Beyond Water-Cement Ratio and Strength. Patrick Harrison Vice President Structural Services, Inc.

MECHANICAL PROPERTIES OF HIGH-PERFORMANCE CLASS C FLY ASH CONCRETE SYSTEMS

SELF COMPACTING CONCRETE FOR LNG TANKS CONSTRUCTION IN TEXAS

Multiple Corrosion Protection Systems for Reinforced Concrete Bridge Components

Transcription:

Paper No. 3288 CORROSION INHIBITORS IN CONCRETE R.J. Kessler, R.G. Powers, and W.D. Cerlanek Florida Department of Transportation State Materials Office 26 NE Waldo Road Gainesville, FL 3269 A.A. Sagüés University of South Florida Department of Civil and Environmental Engineering 422 E Fowler Ave ENB 118 Tampa, FL 3362-535 ABSTRACT This report discusses the behavior of various corrosion inhibitors for steel in concrete. Three commercially available inhibitors (two based on organic compounds and one calcium nitrite-based) were selected for detailed examination. Each inhibitor was evaluated in several types of concrete mix designs. The mixes included Portland cement concrete as the control, concrete admixed with silica fume, and concrete admixed with fly ash for comparison. Non-destructive tests in progress of steelreinforced concrete laboratory specimens are used to identify the time at which corrosion of the reinforcement initiates. Standard specimens containing either of the two organic corrosion inhibitors performed relatively equal to control specimens (Type II cement, no pozzolans, no inhibitors). Standard specimens containing the calcium nitrite-based inhibitor showed improved performance. However, specimens containing silica fume exhibit no corrosion activity to date. Based on current data, the calcium nitrite-based inhibitor was effective in mitigating corrosion in high permeability concretes. However, low-permeability concrete specimens containing pozzolans (particularly silica fume) continue to exhibit a significantly longer time to corrosion initiation than specimens containing only conventional corrosion inhibitors. Keywords: Concrete, corrosion, reinforcing steel, macrocell current, corrosion inhibitor, calcium nitrite, rebar, polarization, pozzolan 1

INTRODUCTION The overall objective of this report is to discuss the behavior of selected commercially available corrosion inhibitors for steel in concrete. The extent to which these inhibitors prevent or slow down corrosion will be contrasted with the beneficial action of fly ash and silica fume. Unlike corrosion inhibitors, these pozzolanic admixtures do not directly influence the electrochemical corrosion reactions themselves, but nevertheless delay corrosion initiation by slowing down the ingress of chloride ions in concrete. The combined effect of the presence of corrosion inhibitors and pozzolanic admixtures will be discussed as well. EXPERIMENTAL PROCEDURE Three commercially available corrosion inhibitors, one calcium nitrite-based (CN) and two based on organic compounds (ORG1, ORG2) (a), were selected for detailed examination 1. For comparison, each inhibitor (plus blank controls) was admixed at recommended dosages per manufacturer guidelines (a) into several types of concrete mix designs, including Type II cement (American Association of State Highway and Transportation Officials [AASHTO] M 85) concrete, concrete admixed with silica fume, and concrete admixed with fly ash. The mixes to be discussed used 985 kg/m 3 of oolitic limestone as coarse aggregate with a maximum diameter of 1 mm. The fine aggregate was silica sand with a fineness module of 2.16. The cementitious factor was 7 bags (39 kg/m 3 ). The pozzolans were admixed as cement replacement in the percentages of 2% by weight of cement for Type F Fly Ash and 8% by weight of cement for silica fume. A summary of the proportions is shown in Table 1. Table 1. Concrete Mix Proportions 7-Bag Std Mix Water/Cement Ratio 2% Fly Ash 8% Silica Fume CTRL X.41 ORG1 X.41 CN X.41 ORG2 X.41 Fly Ash X.41 X Silica Fume X.41 X The mixes were batched in a 27 ft 3 (.76 m 3 ) central mixer, which is located in a warehouse environment. During extreme environmental conditions, batching was conducted in a temperaturecontrolled room, with a portable mixer. To maintain control of the w/c ratio, all components were carefully measured and aggregate moisture adjustments were made. Before batching, all aggregate was obtained from Florida Department of Transportation (FDOT) pre-qualified sources and tests were (a) CN DCI-S manufactured by W.R. Grace & Co, dosage 22 liters per cubic meter of concrete. ORG1 FerroGard 91 manufactured by Sika Corp, dosage 9.9 liters per cubic meter of concrete. ORG2 Rheocrete 222+ manufactured by Master Builders Technologies, dosage 5. liters per cubic meter of concrete. 2

conducted to ascertain proper gradation. The aggregate was bagged and completely saturated by submerging the bagged materials in water. One hour before mixing, the bagged materials were removed from the water and allowed to drain. After mixing, the concrete was placed into the forms in two equal lifts. Using a table vibrator, the specimens were vibrated for 45 seconds per lift, to consolidate the concrete. Each specimen was light- trowel finished and the specimens were then covered with a polyethylene film for 24 hours. All specimens were cured in 1% relative humidity for 72 hours and further cured in a dry warehouse environment for a minimum of 9 days before testing commenced. The specimens were manufactured to provide relatively short-term results, and were placed in a sheltered, outdoor exposure site. The arrangement of the specimens is shown in Figure 1 and the specimen configuration is shown in Figure 2. Conditions for exposure consisted of partial immersion, as seen in Figure 2. The water was a 3% NaCl solution. The specimen and tank temperatures depended on the fluctuations in the daily temperatures in Gainesville, FL. The four tanks are interconnected by water pipes and two pumps are used to circulate the saltwater. Twice daily, the water is circulated for one hour to ensure uniform chloride content within the tanks, and full aeration of the water. Water depth and salt content are measured weekly; each component is added, as necessary, to maintain the desired concentrations, and to maintain the desired water level. Routine specimen testing includes coupled and individual element half-cell potentials (using a standard calomel electrode, [SCE]), resistance to an external electrode, inter-element resistance, macrocell currents, polarization resistance, electrochemical impedance spectroscopy, and wet surface resistivity. Figure 1. Sheltered outdoor specimens Figure 2. Schematic of outdoor specimens Testing continues until specimen failure. Failure of a specimen is considered the point when a corrosioninduced crack is visually detected. Upon failure, specimens are removed from saltwater exposure and cores are taken from uncracked concrete for chloride analysis, which will be reported in a subsequent publication. Continuing work will also take into account the possible extent of inhibitor loss due to leaching out of the specimens during the tests 2,3. RESULTS AND DISCUSSION This paper is based on the test results obtained from the ongoing Corrosion Inhibitors in Concrete 1 project through September 22. Each specimen was tested and monitored until visible indications of corrosion-induced cracking became evident on the surface of the specimen. Many of the specimens have advanced to failure and have been removed from the tanks. All that remain are those specimens admixed 3

with either silica fume or fly ash. The majority of the specimens remaining are those admixed with silica fume. Only a small percentage of specimens admixed with fly ash remain. Unfailed specimens remain under testing conditions. 1 Potentials vs SCE (mv) -1-2 -3 CORROSION THRESHOLD = -28 mv -4-5 2 4 6 8 1 12 14 16 18 2 CTRL ORG1 CN ORG2 FA SF Figure 3. Average coupled (total) half-cell potentials to a SCE over time for all specimen groups. Comparisons Of Inhibitors And Pozzolanic Admixtures Acting Separately Figure 3 shows the evolution of the average coupled (total) half-cell potentials for all of the groups. The potentials shown are averages of all specimens of each group. Each curve terminates at the time the first failed specimen in a group was removed. Half-cell potential evolutions for all individual specimens of all relevant groups are provided in Appendix A. For comparison purposes, The Time to Corrosion Initiation (TCI) for a specimen was assumed to have been reached when the coupled half-cell potential crossed the nominal threshold value of 28 mv/sce (which follows the commonly used assumption of a high probability of corrosion activity per ASTM C-876). By that criterion, the average potential trends in Figure 3 suggest representative TCI values for the specimen groups as shown in Table 2. It should be noted, based on the long-term potential data, that corrosion initiation likely occurred at a much earlier date than that corresponding to the nominal criterion used. As seen in the charts in Appendix A, a noticeable potential shift (~1 to 2 mv) occurs before the specimen potential reaches 28 mv. This shift more likely indicates the actual TCI for the specimen (average values for specimen groups are provided in Table 2). Thus, it is apparent that the 28 mv criterion produces an overestimate of the time to corrosion initiation for these specimens. 4

Sample Name Mix Date Table 2. Average TCI and Days to Failure for Specimen Groups Placement in Saltwater Average Time to First Significant Potential Drop (Days) Average TCI ( 28 mv/sce) (Days) Average Days to Failure* Percent of Failed Samples CTRL 1/28/97 1/15/97 73 29 298 1 ORG1 1/22/97 1/15/97 14 245 418 1 CN 12/16/96 1/15/97 272 484 571 1 ORG2 1/3/97 1/15/97 12 168 279 1 Fly Ash 2/1/97 1/22/97 49 >757** >958** 8 Silica Fume 4/1/97 1/22/97 >128** >1793** >1793** * Failure is considered to be the first visual sign of corrosion-induced cracks. ** Some specimens admixed with fly ash and with silica fume have not become active and testing is ongoing. For each bar in a given specimen (Figure 2), macrocell current between it and the remaining coupled bars were measured and recorded (i.e. bar 1 vs. bars 2 & 3 coupled, bar 2 vs. bars 1 & 3 coupled, etc.). From these readings, the most anodic values were determined. The average of these macrocell currents for each group is plotted against exposure time in Figure 4. 5.. Current (ua) -5. -1. -15. -2. 2 4 6 8 1 12 14 16 18 CTRL ORG1 CN ORG2 FA SF Figure 4. Average anode macrocell current values over time for specimen groups Based on previous observations, for this type of specimen, an anodic bar was considered active once the total macrocell current between that bar and the other coupled bars became 2 µa or greater. Current density was not used due to the uncertainty of the effective area. The TCI values based on macrocell current agreed generally well with those TCI values estimated from half-cell potential measurements. 5

The Rapid Chloride Permeability (RCP) test utilized was in accordance with American Society for Testing and Materials (ASTM) C 122. The purpose of this test is to estimate the permeability of the concrete by measuring its conductivity. The 36-day tests showed lower results than the corresponding 28-day tests. This indicates that the concrete in the samples improved, which also indicates that the concrete continued to cure. The continual curing is also seen in the 28-day compression (ASTM C 39) results versus the 36-day compression results. Table 4 shows the results of the 28-day and 36-day results of both the RCP and the compressions tests. Sample Name Table 4. RCP and Compressions at 28 and 36 Days 28-Day RCP (Coulombs) 36-Day RCP (Coulombs) 28-Day Compression (MPa) 36-Day Compression (MPa) CTRL 5689 4448 47.8 53. ORG1 >12 471 51.6 57.4 CN N/A* N/A* 42.6 48.1 ORG2 9821 6943 36.9 41.8 Fly Ash 6793 111 42.8 56.7 Silica Fume 1149 895 57.3 58.9 * This test is not applicable, since the ionic properties of the calcium nitrite have an effect on the results. Combination Effects Between Individual Inhibitor Groups And Pozzolan Groups Effects of the combinations between each inhibitor and each pozzolan were studied. In the following, trends in average potential, cumulative TCI behavior, and time to failure are considered. Figure 5 shows half-cell potential comparisons between control specimens, fly ash specimens, silica fume specimens, ORG1 specimens, ORG1 plus fly ash specimens, and ORG1 plus silica fume specimens. When FA specimens are compared with ORG1+FA specimens, the latter specimen group shows an improved TCI. No noticeable potential trend differences exist between control groups with and without ORG1 or silica fume groups with and without ORG1. Half-cell potentials over time for like specimens groups with and without admixed CN are displayed in Figure 6. When CN was introduced into a mix containing no pozzolans or a mix with admixed fly ash, the potential trends indicated a beneficial effect in extending the TCI compared to control specimens. However, for the CN - silica fume combinations one of the six specimens showed sudden potential drop at ~day 15 quickly followed by failure. The remaining CN-SF specimens had potential trends comparable to the SF-only specimens. Half-cell potentials over time for like specimens groups with and without admixed ORG2 are displayed in Figure 7. No noticeable differences exist between comparable specimen groups. The data series in Figures 3 through 7 are limited by truncation due to removal of failed specimens. For completeness, Figure 8 displays the cumulative fraction of all specimens in a particular group that have reached a sustained coupled half-cell potential of 28 mv (SCE) as a function of the time it took to reach that potential. This representation gives an overall view of the variability of specimen behavior within a group, as well as general TCI comparisons between groups. As indicated earlier by the average 6

1 Potential vs. SCE (mv) -1-2 -3-4 -5 2 4 6 8 1 12 14 16 18 Time (days) CTRL ORG1 FA ORG1+FA SF ORG1+SF Figure 5. Average total half-cell potentials over time comparing specimen groups with and without admixed ORG1. 1 Potential vs. SCE (mv) -1-2 -3-4 -5 2 4 6 8 1 12 14 16 18 Time (days) CTRL CN FA CN+FA SF CN+SF Figure 6. Average total half-cell potentials over time comparing specimen groups with and without admixed CN. 7

1 Potential vs. SCE (mv) -1-2 -3-4 -5 2 4 6 8 1 12 14 16 18 Time (days) CTRL ORG2 FA ORG2+FA SF ORG2+SF Figure 7. Average total half-cell potentials over time comparing specimen groups with and without admixed ORG2. Fraction of Specimens Reaching -28mV (SCE) 1.9.8.7.6.5.4.3 CTRL ORG2 ORG1 CN FA ORG1+FA ORG2+FA CN+FA.2 CN+SF ORG2+SF.1 ORG1+SF SF 2 4 6 8 1 12 14 16 18 Figure 8. Fraction of specimens within each group reaching 28 mv/sce at given times. 8

potential trends, CN shows an approximate 3 to 1 increase in TCI against CTRL for concrete with no added pozzolans, while the organic inhibitors show little discernible gain. The FA group shows distinctly improved behavior while no initiation events per the adopted criterion occurred in the SF group over the entire test period. Finally, all but one specimen with admixed silica fume (CN+SF) continue to age with no sign of corrosion activity. The time to failure results in Table 6 correlate well with the observations inferred from the potential (and macrocell current) observations, indicating that the combined corrosion initiation-propagation behavior paralleled trends established during the initiation phase. Table 6. Days to Failure Admixed Days to Failure* Pozzolan CTRL ORG1 CN ORG2 1 st Failure Average 1 st Failure Average 1 st Failure Average 1 st Failure Average None 25 298 36 418 476 571 167 279 Fly Ash 53 >958 882 >1338 7 >178 53 854 Silica Fume >1793 >1793 >1793 >1793 152 >167 >1793 >1793 * Failure is considered to be the first visual sign of corrosion-induced cracks. Note: The presence of a > symbol indicates that a portion of specimens remain under evaluation. Values that do not have a > symbol indicate that all specimens in that group have failed. The overall results indicate that one of the organic products had little or no inhibiting effect under any of the material conditions examined. In the more permeable concrete formulations, the other organic inhibitor and the nitrite-based inhibitor showed some beneficial effects. The permeability of the SF concrete is very low and test times have not been long enough to sufficiently evaluate the performance of any of the inhibitors in combination with that pozzolanic admixture. The significance of the relatively early failure of one of the CN-SF specimens will need to be evaluated in terms of the behavior of the peer specimen group as longer test times accumulate. CONCLUSIONS 1. There is good agreement in inferences on corrosion behavior made from each of the performance indicators used (potential evolution, macrocell current, Time to Corrosion Initiation [TCI] and Time To Failure [TTF]). 2. In fly-ash admixed concrete (no inhibitor added) there was at least a three-fold increase in TCI and TTF over that of the non-fly-ash control mix. 3. In silica fume admixed concrete (no inhibitor added) there was at least a six-fold increase in TCI and TTF over that of the respective control mix. Testing continues. 4. Calcium nitrite was the only inhibitor to show a significant increase in TCI and TTF in the high permeability, non-pozzolanic admixed concrete. 5. Presently, only ORG-1 and calcium nitrite in fly-ash concrete reveal noticeable increases in TCI or TTF over that of the fly-ash control mix. ORG-2 showed no noticeable effect. Testing continues. 9

6. None of the three inhibitors admixed in silica fume concrete presently reveal discernable behavior differences compared to their non-inhibitor added controls. Testing continues. 7. The 28 mv criterion produced overestimates of TCI based on comparisons with long-term potential measurements. NOTICE AND ACKNOWLEDGMENTS The assistance of Mario A. Paredes and Donna R. Fugatt of FDOT is gratefully acknowledged. The authors are also indebted to Dr. Y.P. Virmani for many helpful discussions. This investigation was conducted with support from the Federal Highway Administration and the FDOT. The opinions and findings indicated here are those of the authors and not necessarily those of the supporting organizations. The United States Government or the State of Florida assumes no liability for the content or use of this publication; it does not constitute a standard, specification, or regulation. The United States Government or the State of Florida does not endorse products or manufacturers. Trade and manufacturers names appear in this publication only because they are considered essential to the object of the document. REFERENCES 1. R.G. Powers, A.A. Sagüés, W.D. Cerlanek, and C.A. Kasper, Corrosion Inhibitors in Concrete, Interim Report, pp. 32-52, Report Number FHWA-RD-2-2, National Information Service, Springfied, VA, 22. 2. R.G. Powers, A.A. Sagüés, W.D. Cerlanek, C.A. Kasper and L. Li, Time to Corrosion of Reinforcing Steel in Concrete Containing Calcium Nitrite, U.S. Department of Transportation, FHWA Publication No. FHWA-RD-99-145, McLean, VA., October 1999. 3. H. Liang, L. Li, N.D. Poor, A.A. Sagüés, Cement and Concrete Research 33, pp.139 146, 23. 1

Appendix A 11

1 Potential vs SCE (mv) -1-2 -3-4 -5 5 1 15 2 25 3 35 4 45 CTRL A CTRL B Figure A-1. Potential evolution for individual CTRL specimens 1-1 Potential vs. SCE (mv) -2-3 -4-5 -6 1 2 3 4 5 6 7 ORG1 A ORG1 B ORG1 C ORG1 D ORG1 E Figure A-2. Potential evolution for individual ORG1 specimens 12

1 Potential vs. SCE (mv) -1-2 -3-4 -5 1 2 3 4 5 6 7 8 CN A CN B CN C Figure A-3. Potential evolution for individual CN specimens -5-1 -15-2 -25-3 -35-4 -45-5 5 1 15 2 25 3 35 4 45 ORG2 A ORG2 B Figure A-4. Potential evolution for individual ORG2 specimens 13

1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 FA A FA B FA C FA D FA E Figure A-5. Potential evolution for individual FA specimens 1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 ORG1+FA A ORG1+FA B Figure A-6. Potential evolution for individual FA with ORG1 specimens 14

1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 CN+FA A CN+FA B CN+FA C CN+FA D CN+FA E Figure A-7. Potential evolution for individual FA with CN specimens 1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 ORG2+FA A ORG2+FA B ORG2+FA C ORG2+FA D ORG2+FA E Figure A-8. Potential evolution for individual FA with ORG2 specimens 15

1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 SF A SF B SF C SF D SF E SF F Figure A-9. Potential evolution for individual SF specimens 1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 ORG1+SF A ORG1+SF B ORG1+SF C ORG1+SF D ORG1+SF E ORG1+SF F Figure A-1. Potential evolution for individual SF with ORG1 specimens 16

1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 CN+SF A CN+SF B CN+SF C CN+SF D CN+SF E CN+SF F Figure A-11. Potential evolution for individual SF with CN specimens 1-1 -2-3 -4-5 2 4 6 8 1 12 14 16 18 ORG2+SF A ORG2+SF B ORG2+SF C ORG2+SF D ORG2+SF E Figure A-12. Potential evolution for individual SF with ORG2 specimens 17