RISER DETAIL NTS SHANNON FIRE PROTECTION, LLC SCALE: 3/32" = 1'-0"

Similar documents
COIN QR UPRIGHT FUSIBLE ELEMENT SPRINKLER VK901 (SPECIFIC APPLICATION) TECHNICAL DATA

COIN QUICK RESPONSE UPRIGHT SPRINKLER VK900 (SPECIFIC APPLICATION) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

TECHNICAL DATA COIN QUICK RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION)

SPECIFIC APPLICATION MODEL "IC" INTERSTITIAL COMBUSTIBLE CONCEALED SPACE UPRIGHT SPRINKLER GL5608

Sprinkler Identification Numbers (SINs)

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible

SPECIFIC APPLICATION MODEL "IC" INTERSTITIAL COMBUSTIBLE CONCEALED SPACE UPRIGHT SPRINKLER GL5608

MICROFAST COIN TM QUICK RESPONSE UPRIGHT SPRINKLER SIN VK900 (SPECIFIC APPLICATION) TECHNICAL DATA

Design Criteria, CPVC Pipe

40.09 V25, K4.2 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS SPECIFIC APPLICATION V2502 UPRIGHT QUICK RESPONSE

Design Criteria, CPVC Pipe

SPECIFIC APPLICATION ATTIC SPRINKLERS

SPECIFIC APPLICATION ATTIC SPRINKLERS

SPECIFIC APPLICATION ATTIC SPRINKLERS

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

NEWS LETTER MARCH 27, 2009

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

APPLICATION FOR FINISHED BASEMENT PERMIT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

3. technical data. Page 1 of 10

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

Presented by: Stephen Carr Regional Building Science Manager (386)

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

GF HARVEL CPVC FIRE SPRINKLER PIPING PRODUCTS

RESIDENTIAL BUILDING REQUIREMENTS

Presented by: Stephen Carr Regional Building Science Manager (386)

WATER SUPPLY AND DISTRIBUTION

Only required in new home construction

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

TRUMAN STATE UNIVERSITY OPHELIA PARRISH FINE ARTS CENTER ACOUSTICAL RENOVATIONS TABLE OF CONTENTS DIVISION 21 FIRE PROTECTION SYSTEM

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

IRC 2012 Key Changes

FRAMING INSPECTION GENERAL

CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET. Adopted Codes:

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

2003 International Residential Building Code

BlazeMaster CPVC Fire Sprinkler Systems

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

Changes to NFPA 13 from the 2013 Edition to the 2016 Edition. James Golinveaux

RESIDENTIAL BASEMENT ALTERATIONS GUIDE

SECTION FIRE SPRINKLER NARRATIVE PART 1 - GENERAL INTRODUCTION

First Revision No. 634-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Safety margins for this property are as follows: Prior to Instalation: PSI Saftey After Instalation: PSI Safety

11.1.2* Adjacent Hazards or Design Methods. For buildings with two or more adjacent hazards or design methods, the following shall apply:

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

CHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION

Extended Coverage Sprinklers

Explaining the Thermal Bypass Checklist. Ed Minch, Energy Services Group Kelly Parker, GWS

FIELD COPY ATTACHMENT

Basement Finish. City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN (952) Fax (952)

Hardin County Planning and Development Commission

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION SUPPORTS AND ANCHORS

Building Codes and Ordinances ARC 227

* RESIDENTIAL PLAN REVIEW *

PIPING SPECIALTIES (PLUMBING) A. American Society for Testing and Materials (ASTM):

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013

Fairfax County, Virginia

ADDENDUM A CONSTRUCTION SPECIFICATIONS

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Typical Finished Basement Details

General Residential Code Requirements

General Residential Code Requirements

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks

ROWHOUSE CONSTRUCTION

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

INTERNATIONAL CODE INTERPRETATIONS

Common Plan Review Rejection Reasons

2018 IRC Sections R303 through R310 Building Planning II

Applications for building permits will not be reviewed until all of the required information has been submitted.

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Common Plan Review Rejection Reasons

Re-inspections due to failed work or jobs that are not accessible cost both contractors and city inspectors time and money.

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

Session: Firestop - Let s Walk a Project and Look at Firestop Together

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

Advanced Ventilation for Residential applications FBC Res 2010.

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Feature Zone IECC 2009 IECC

CHAPTER 6 TYPES OF CONSTRUCTION

One & Two Family Residential ADDITIONS

SECTION STANDPIPE AND HOSE SYSTEMS

DEVICES AND LUMINAIRES

FS , 712, 713, 714

Residential Building Permit Application Note: Storm Water Permit may be required.

Applying the Building Code During Design

Design & Construction Standards, Revised January

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Transcription:

MAXIMUM DISTANCE BETWEEN HANGERS NOMINAL PIPE SIZE (in.) 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 5" 6" 8" STEEL PIPE EXCEPT THREADED LIGHTWALL THREADED LIGHTWALL STEEL PIPE COPPER TUBE 10-0 10-0 CPVC 5-6 6-0 6-6 7-0 9-0 POLYBUTYLENE (IPS) 3-9 4-7 5-0 5-11 POLYBUTYLENE (CTS) 2-11 3-4 3-11 4-5 5-5 ROD SIZE 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" VIKING FREEDOM RESIDENTIAL PENDENT SPRINKLER SIN = VK468, 4.9K ESCUTCHEON PLATE = E-1 SMOOTH FLAT HROIZONTAL CEILING, SLOPES UP TO 2-1/2" MINIMUM COLD COLDER SPACING = 8' MAXIMUM SPACING = 256 SF, 16' X 16'-0 WITH 8'-0 OFF WALL MAXIMUM RECESSED WRENCH P/N: 12144W/B - THE MAXIMUM UNSUPPORTED LENGTH BETWEEN THE SPRINKLER HEAD AND THE LAST HANGER ON THE LINE FOR PRESSURES LESS THAT 100 PSI IS, 1" = 3'; 1-1/4" = 4'; 1-1/2" = 5' FOR STEEL PIPE. IF THE PRESSURE EXCEEDS 100 PSI THAT 12" FOR STEEL PIPE AND 6" FOR COPPER TUBE. - THE HANGER CLOSEST TO THE SPRINKLER SHALL PREVENT UPWARD MOVEMENT. - THE HANGER ROD SHALL BE WITHING 1/8" TO THE TOP OF THE PIPE OR USE SURGE RESTRAINER CLIPS TO PREVENT UPWARD MOVEMENT. - THE LONGEST HORIZONTAL LENGTH OF AN UNSUPPORTED ARM OVER TO A SPRINKLER, UNSUPPORTED DROP, OF SPRIG-UP, SHALL NOT EXCEED 24" FOR STEEL OR 12" FOR COPPER TUBE. IF THE PRESSURE EXCEEDS 100 PSI THAN 12" FOR STEEL AND 6" FOR COPPER TUBE. REDUCE TO 1-1/2 CPVC AT TOP OF EACH RISER RISER DETAIL NTS 4.0 K, 1/2" NPT, SIN = VK486 ESCUTCHEON PLATE = E-1 SMOOTH FLAT HROIZONTAL CEILING, SLOPES UP TO 2-1/2" MINIMUM COLD COLDER SPACING = 8' MAXIMUM SPACING = 288 SF, 16' WIDTH AND 18' THROW CEILING DEFLECTOR FROM 4" TO 6" OR 6" TO 12" RECESSED WRENCH P/N: 13196W/B WET SYSTEM GENERAL NOTES : 3/32" = 1'-0" - Protection Area Limitation: Total Sq Ft =800 - Classification of Occupancy: ReSIDENTIAL - System Hydraulic Design: DESIGNED PER NFPA #13R RESIDENTIAL - All hanger material and methods are pre NFPA 13, see details. - Sprinkler system is to be tested at 200 psi for 2 hours, per NFPA 13. - + Elevations = Finished Floor to Center Line of the Pipe. - * Elevations = Top Of Something (TOS) to Center Line of the Pipe. - Cutting of structural members to be done by others. - All penetrations in fire walls and floors to be fire caulked per UL. - Access panels to be provided and installed by others. - Spare sprinkler stock provided per NFPA 13. - Systm design pressure not to exceed 175 psi. - All control valves to be electronically supervised or locked open. - Wiring of all electronic devices to be done by others. - All sprinkler heads to be a minimum of 4" from any wall. - Maintain a minimum distance of 18" from the sprinkler deflector to the top of the storage. - Sprinklers to be installed below ductwork 4 feet or wider. - Inspectors test valve to be no more than 7' above finished floor. - Spare stock of heads to be provided per NFPA 13. - Head Guards to be provided on any heads lower than 7' AFF. - Valve signs and identification to be provided per NFPA 13. RESIDENTIAL AREA'S HEADS CAN BE OMITTED 1) BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ. FT. AND THE WALLS AND CEILINGS, INCLUDING BEHIND FIXTURES, ARE OF NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS PROVIDING A 15 MINUTE THERMAL BARRIER. THE TUB AND SHOWER FIXTURE DOES GET INCLUDED IN THE ROOM DIMENSIONS. 2) CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WITHIN THE DWELLING UNITS WHERE THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ. FT. AND THE LEAST DIMENSION DOES NOT EXCEED 3 FT AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220' 3) ANY PORCHES, BALCONIES, CORRIDORS, AND STAIRS THAT ARE OPEN AND ATTACHED. 4) ATTICS, PENTHOUSE EQUIPMENT ROOMS, CRAWL SPACES, /CEILING SPACES, ELEVATOR SHAFTS, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES OR STORAGE. EXPOSED CPVC NOTES: 1. MAXIMUM AREA IS 1000 SQ. FEET. GENERAL CONTRACTOR TO PROVIDE BLOCKING TO REDUCE AREA'S TO 1000 SQUARE FEET OR LESS. 2. MAXIMUM RUN FOR JOISTS IS 32 LINEAR FEET. GENERAL CONTRACTOR TO PROVIDE BLOCKING TO REDUCE JOIST RUN OF 32 FEET OR LESS. 3. GENERAL CONTRACTOR TO PROVIDE BLOCKING IN BETWEEN FINISHED AREA'S AND UNFINISHED AREA'S 4. BLOCKING TO BE CONSTRUCTED OF: A. 1/2" PLYWOOD, MINIMUM 3/8" GYPSUM WALLBOARD, OR BATT INSULATION WITH A MINIMUM THICKNESS OF 3-1/2 INCHES. WHEN BATT INSULATION IS USED IT MUST BE A SINGLE PIECE OF INSULATION. IT MUST BE SECURED WITH WIRE NETTING WHICH MUST ENCASE THE INSULATION ON BOTH OF THE EXPOSED SIDES. THE WIRE NETTING IS REQUIRED TO HOLD THE INSULATION IN PLACE AND PREVENT IT FROM BEING DISLODGED OR REPOSITIONED OVER TIME. IT IS ACCEPTABLE FOR ITEMS SUCH AS PIPING, WIRES, DUCTS, ETC. TO PENETRATE THE BLOCKING. THE GAP BETWEEN THE ITEM PENETRATING THE BLOCKING AND BLOCKING SHOULD BE MINIMIZED. FOR INSTALLATIONS WHERE THE GAP EXCEEDS 1/4" INCH THE GAP SHALL BE FILLED WITH INSULATION, CAULKING OR OTHER SUITABLE MATERIAL. UNITS E161, E151, E141, E131, E121, E111 ROYAL MEWS

METER PIT FOR BACKFLOW NEW 2" PLASTIC FIRE LINE INTO BUILDING APPROX 50'-0 " NEXT NEXT NEXT NEXT FIRST PLAN ALL SIDEWALLS IN LOFTS FED FROM THIS WITH 1" CPVC RISERS UNITS E161, E151, E141, E131, E121, E111 ROYAL MEWS

SECOND PLAN ALL SIDEWALLS IN LOFTS FED FROM THIS WITH 1" CPVC RISERS

PREVIOUS PREVIOUS PREVIOUS PREVIOUS PREVIOUS PREVIOUS THIRD PLAN ALL SIDEWALLS IN LOFTS FED FROM THIS WITH 1" CPVC RISERS

LOFT PLAN ALL SIDEWALLS ARE FED FROM 1" BELOW ALL SIDEWALLS DESIGNED TO BE SPACED 16 FEET AND 20 FEET THROW RESIDENTIAL REMOTE #1 02.05 288 RESIDENTIAL 4.0 1/2' 16.0 2 HEADS 32.0 66.5 CITY CONNECTION 43.47 PSI