DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

Similar documents
Union County Vocational - Technical Schools Scotch Plains, New Jersey

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

1.1 RELATED DOCUMENTS

Acousti-Seal 932. Operable Partitions (10650)

Acousti-Seal 933E. Operable Partitions (10650)

Acousti-Seal 931. Operable Partitions (10650)

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

1.1 RELATED DOCUMENTS

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

1.1 RELATED DOCUMENTS

SECTION OPERABLE PARTITIONS. A. American Society for Testing and Materials (ASTM):

A. American Society for Testing and Materials (ASTM):

Soundmaster & Modernfold TECHNICAL DATA

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

SECTION ACCORDION FOLDING PARTITIONS

Series 3000 Pocket Doors

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

1.1 RELATED DOCUMENTS

ACOUSTI-SEAL ENCORE SERIES TECHNICAL DATA

MOVEABLE GLASS WALL TECHNICAL DATA

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

2000 POCKET DOOR TECHNICAL DATA

Model 2030 Hinged Pairs

Technical Data Sheet Signature 842

GLASS WALL SPECIFICATIONS

3000 SERIES POCKET DOOR

Model 4010 Individual Panels / Curve & Diverter

Model 2020 Individual Panels / Multi-Directional

Model 3010 Individual Panels / Curve & Diverter

Doc

2030 TECHNICAL DATA Series panels, Hinged in Pairs. KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

MODEL KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

GLASS WALL SPECIFICATIONS

GLASSWALL SPECIFICATIONS

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

3030 TECHNICAL DATA Series panels, Hinged in Pairs

SECTION IMPACT RESISTANT WALL PROTECTION

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Section PANEL SIGNAGE

North Hanover Township School District North Hanover Township, New Jersey

SECTION AWNINGS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

OPERABLE PARTITIONS. Signature

Product Guide Specification

GLASSWALL SPECIFICATIONS

Single Panel used with odd numbered panel openings. Single Panel With Expandable Panel - used with odd numbered. panel openings.

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

3030 GL TECHNICAL DATA

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

Product Guide Specification

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

Series 633E SPECIFICATIONS

SECTION SOUND CONTROL DOORS

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

OPTIONS SPECIFICATIONS See page 6 for Product Specifications

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

SECTION ORCHESTRA PIT FILLER

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

A. Access doors and frames are part of an access door and frame allowance.

2020 TECHNICAL DATA Series Individual Panels/Multi-Directional. KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

SERIES 641 SPECIFICATIONS

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

SECTION DOOR HARDWARE

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Union County Vocational - Technical Schools Scotch Plains, New Jersey

5. Division 9 Section "Site-Built Stretched Fabric Wall System" for site-built stretched fabric

ALL-ALUMINUM DOOR & WINDOW FRAMING

1. Standard two tier metal lockers and metal base.

3020 TECHNICAL DATA Series panels, Individual Panels/Multi-Directional

Soundmaster Modernfold Accordion Doors & Partitions

SECTION DOOR AND WALL PROTECTION

DIVISION VIII - DOORS AND WINDOWS

MODEL Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

3020 GL TECHNICAL DATA

MODEL 3020WT. Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit

Series 643E SPECIFICATIONS

Model 810 MD Multi- OPTIONS SPECIFICATIONS See page 8 for Product Specifications

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

SECTION SECTIONAL OVERHEAD DOORS

SERIES 631 SPECIFICATIONS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ACCESS DOORS AND FRAMES

SECTION SOUND-ABSORPTIVE PANELS

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

MODEL KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Transcription:

DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Manually operated, acoustical panel partitions. B. Related Sections: 1. Division 05 Section "Metal Fabrications" for supports that attach supporting tracks to overhead structural system. 2. Division 06 Section Rough Carpentry for wood blocking supports. 3. Division 26 Section Electrical 1.3 DEFINITIONS A. ADA-ABA Accessibility Guidelines: U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA) and Architectural Barriers Act (ABA) Accessibility Guidelines for Buildings and Facilities." B. NRC: Noise Reduction Coefficient. C. STC: Sound Transmission Class. 1.4 PERFORMANCE REQUIREMENTS A. Delegated Design: Design operable panel partitions, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated. B. Seismic Performance: Operable panel partitions shall withstand the effects of earthquake motions determined according to SEI/ASCE 7 and OBC. 1. The term "withstand" means "the panels will remain in place without separation of any parts from the system when subjected to the seismic forces specified." C. Acoustical Performance: Provide operable panel partitions tested by a qualified testing agency for the following acoustical properties according to test methods indicated: 13-HC1-033 10 22 26-1

1. Sound-Transmission Requirements: Operable panel partition assembly tested for laboratory sound-transmission loss performance according to ASTM E 90, determined by ASTM E 413, and rated for not less than the STC indicated. 1.5 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work. 1. Indicate storage and operating clearances. Indicate location and installation requirements for hardware and track, blocking, and direction of travel. 2. Indicate loading to be imposed in the supporting structure. 3. Indicate embedded items to be incorporated into other work. C. Samples for Initial Selection: For each type of exposed material, finish, covering, or facing indicated. Include similar Samples of accessories involving color selection. D. Samples for Verification: For each type of exposed material, finish, covering, or facing indicated, prepared on Samples of size indicated below: 1. Textile: 12 x 12 section of fabric from dye lot to be used for the Work, with specified treatments applied. Show complete pattern repeat. 2. Panel Facing Material: Manufacturer's standard-size unit, not less than 3 inches square. 3. Panel Edge Material: Not less than 3 inches long. E. Qualification Data: For qualified Installer and testing agency. F. Product Certificates: For each type of operable panel partition, from manufacturer. G. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each operable panel partition. H. Operation and Maintenance Data: For operable panel partitions to include in maintenance manuals. In addition to items specified in Division 01 include the following: 1. Panel finish facings and finishes for exposed trim and accessories. Include precautions for cleaning materials and methods that could be detrimental to finishes and performance. 2. Seals, hardware, track, carriers, and other operating components. 1.6 QUALITY ASSURANCE A. Installer Qualifications: An employer of workers trained and approved by manufacturer. B. Testing Agency Qualifications: Qualified according to Division 01 for testing indicated. C. Fire-Test-Response Characteristics: Provide panels with finishes meeting one of the following as determined by testing identical products by UL or another testing and inspecting agency acceptable to authorities having jurisdiction: 1. Surface-Burning Characteristics: As determined by testing per ASTM E 84. 10 22 26-2 13-HC1-033

D. Pre-installation Conference: Conduct conference at Project site. 1.7 DELIVERY, STORAGE, AND HANDLING A. Protectively package and sequence panels in order for installation. Clearly mark packages and panels with numbering system used on Shop Drawings. Do not use permanent markings on panels. 1.8 PROJECT CONDITIONS A. Field Measurements: Verify actual dimensions of operable panel partition openings by field measurements before fabrication. 1.9 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of operable panel partitions that fail in materials or workmanship within specified warranty period. 1. Failures include, but are not limited to, the following: a. Faulty operation of operable panel partitions. b. Deterioration of metals, metal finishes, and other materials beyond normal wear. 2. Warranty Period: 1 year from date of Substantial Completion. PART 2 - PRODUCTS 2.1 MANUALLY OPERATED PARTITIONS (SINGLE AND PAIRED PANEL) A. Operable Acoustical Panels: Operable acoustical panel partition system, including panels, seals, finish facing, suspension system, operators, and accessories. a. Basis-of-Design Product: Subject to compliance with requirements, provide Modernfold, Inc.; a DORMA Group Company, or comparable product by one of the following: b. Hufcor. c. Panelfold Inc. d. Moderco B. Classroom Panel Operation: Manually operated, paired panels. C. Stage Panel Operation: Manually operated, single panels. D. Panel Construction: Provide top reinforcement as required to support panel from suspension components and provide reinforcement for hardware attachment. Fabricate panels with tight hairline joints and concealed fasteners. Fabricate panels so finished in-place partition is rigid; 13-HC1-033 10 22 26-3

level; plumb; aligned, with tight joints and uniform appearance; and free of bow, warp, twist, deformation, and surface and finish irregularities. 1. Panels shall not require or permit trim on the vertical edges and shall create a minimal groove at panel-to-panel joints. E. Dimensions: Fabricate operable acoustical panel partitions to form an assembled system of dimensions indicated and verified by field measurements. 1. Panel Width: 48". F. STC: Not less than 50. G. Panel Weight: 8 lb/sq. ft. maximum. H. Panel Thickness: Not less than 3 inches. I. Hinges for Panels, Closure Panels, Pass Doors and Pocket Doors 1. Panel hinges shall be full leaf butt hinges, attached directly to the panel frame. Welded hinge anchor plates within panel shall further support hinge mounting to frame. Hinges mounted into panel edge or vertical astragal is not acceptable. J. Steel Frame: Steel sheet, 18 gauge nominal minimum thickness for uncoated steel. K. Gypsum Board: ASTM C 36/C 36M. (Paired Panel Partitions) L. Single Panel Stage Partitions: Minimum 22ga. roll-formed steel 2.2 SOUND SEALS (MANUALLY OPERATED PARTITIONS) A. Vertical interlocking sound seal between panels, (astragals), of a reversible tongue and groove configuration shall be required in each panel edge, providing universal panel operation. Astragals shall be steel for maximum durability, and fire resistance. Rigid plastic astragals are not acceptable. B. Horizontal top seals shall be continuous contact extruded vinyl bulb shape with pairs of noncontacting vinyl fingers to prevent distortion and no mechanically operated parts. C. Horizontal bottom floor seals shall be IA1 Bottom Seal. Automatic operable seals providing nominal 1 operating clearance with an operating range of +/-0.50 and shall automatically drop as panels are positioned without the need for tools or cranks. 2.3 SUSPENSION SYSTEMS (MANUALLY OPERATED PARTITIONS) A. #17 Suspension System shall be all steel, with a minimum 11 ga. roll-formed steel. Track shall be capable of either direct mounting to a wood header or shall be supported by adjustable steel hanger brackets connected to structural support by pairs of.38 diameter threaded rods. Brackets must support the loadbearing surface of the track. B. Aluminum Tracks capable of supporting the panel system shall be acceptable. C. Carriers: All steel trolley system with steel ball. Non-steel tires are not acceptable. 10 22 26-4 13-HC1-033

2.4 ACCESSORIES (MANUALLY OPERATED PARTITIONS) A. Work Surfaces: Quantities, placement, and size indicated as follows: 1. Provide work surfaces on both sides. 2. Surface: Classroom and Stage Panels - Self-healing, tackable, vinyl-coated fabric wall covering, complying with CFFA-W-101-D, Type II, and indicated fire-test-response characteristics; laminated to natural cork tackboard. 3. Surface Color: As selected by Architect from manufacturer's full range. 4. Trim is not acceptable on vertical edges to provide uninterrupted work surface. 2.5 FINISH FACING A. General: Provide finish facings for panels that comply with indicated fire-test-response characteristics and that are factory applied to operable panel partitions with appropriate backing, using mildew-resistant nonstaining adhesive as recommended by facing manufacturer's written instructions. 1. Apply facings free of air bubbles, wrinkles, blisters, and other defects, with edges tightly butted, and with no gaps or overlaps. Horizontal seams are not permitted. Tightly secure and conceal raw and selvage edges of facing for finished appearance. 2. Color/Pattern: As selected by Architect from manufacturer's full range. B. Vinyl-Coated Fabric Wall Covering: Manufacturer's standard, mildew-resistant, washable, vinylcoated fabric wall covering; complying with CFFA-W-101-D for type indicated; Class A. 1. Total Weight: 30 ounces per lineal yard. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine flooring, structural support, and opening, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of operable panel partitions. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Comply with ASTM E 557 except as otherwise required by operable panel partition manufacturer's written installation instructions. B. Install operable panel partitions and accessories after other finishing operations, including painting, have been completed. C. Install panels from marked packages in numbered sequence indicated on Shop Drawings. D. Broken, cracked, chipped, deformed, or unmatched panels are not acceptable. 13-HC1-033 10 22 26-5

E. Broken, cracked, deformed, or unmatched gasketing or gasketing with gaps at butted ends is not acceptable. 3.3 ADJUSTING A. Adjust operable panel partitions to operate smoothly, without warping or binding. Lubricate hardware and other moving parts. B. Adjust pass doors to operate smoothly and easily, without binding or warping. Check and readjust operating hardware. Confirm that latches and locks engage accurately and securely without forcing or binding. 3.4 CLEANING A. Clean soiled surfaces of operable panel partitions to remove dust, loose fibers, fingerprints, adhesives, and other foreign materials according to manufacturer's written instructions. END OF SECTION 10 22 26 10 22 26-6 13-HC1-033