TM Wallbox Power Module HWI-WPM-6D VAC, 50/60Hz HWI-WPM-6D VAC, 50/60Hz

Similar documents
Installation Instructions. Overview. Important Notes. LINCTM Enclosure EDB-WPM-GRX-6-CE


product specifications e

SS Wallstation Installation Guide

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Installation and Operation Manual

Sivoia QS Skylight Shade (4.75 inch frame)

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

General Safety Information

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Sivoia QS roller 225. Lutron Sivoia QS. Roller 225TM shades

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Downlight Position... 2 Tilted Position... 2 Sloped Ceilings... 2

M LIM Line Leak Interface Module Procedure Guide (only for the Integra 500)

Royal Sovereign RSL 2701 Laminator

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

Moving money forward UV MG

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

OptoLum MegaLine RGBW Luminaire

E-Series Installing E-Series U Cabinet

CM-v-3 module. GSM/GPRS/EDGE communication module for MT880 meters. Technical description

Saphyr System Safety Guide for Saphyr P/N 60325

DUST FREE ACTIVE Total Home Air Purification

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

ABSORPTION HYBRID FILTER FAR-Q TYPE

Table of contents. 1. Introduction

PD662 LOOP-POWERED METER

PD662 LOOP-POWERED METER Instruction Manual

TallSlateTM Grandee Installation Manual

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

Quick Start Guide. Effective February 2015 New Information

2-Position T1/HDSL Environmental Mounting Assembly Model EM02-0xx

Model 5200 Cargo Lift Installation and Operation Manual

General-Purpose Scale Bases

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Key-type Selector Switches

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

User Manual

Model 5000 Cargo Lift Installation and Operations Manual

DIN Panels and Accessories

2 3 Rough-in Wiring Rough-in

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

FAST SPOTTER WT-FS-5.0

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

Owner s Manual & Safety Instructions

Model 5200 Cargo Lift Installation and Operation Manual

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Pallet Safe: Installation Supplement Rev

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)

DMC When Accuracy Counts

P1902 Installation Manual

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

AUTOMATIC CAPACITOR BANK FOR LOW VOLTAGE NETWORKS INSTRUCTION MANUAL. MIBATBT_05i

MODEL INSTALLATION INSTRUCTIONS

booster EX2 / EX3 Operating Manual Extrusion Welder Weldy AG Galileo-Strasse 10 CH-6056 Kaegiswil / Switzerland TECHSPANGROUP

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

Calibrate Accessory Actuators Instructions

DJ Switch 10F V2 ORDERCODE 50365

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

Wealtec Corp. E-Centrifuge Microcentrifuge Operation Manual. Version 3.0 Item # *This instrument is intended for laboratory use only

64C Amplification Block. Instruction Manual

Sby SR Instruments, Inc.

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., UNIT B-1, TEMECULA, CA PHONE (951) FAX (951)

Please read through the usage and service instructions outlined in this owner s manual before operating the unit. Warnings Diagrams...

MODELS PH PH PH

Adjustable Fused Power Supply

Installation. Basic Rack Power Distribution Units AP9560 AP9561

CH-200M. Ceiling Type X-ray Tube Support GENERAL FEATURES PD

INSTALLATION INSTRUCTIONS

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

Outdoor Enclosure. Installation, Operation and Maintenance Manual

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

WP200e Wallbox to CD Changer Adapter

PD662 Loop-Powered Meter Instruction Manual

i i i i i i i i i i i i i i i i i i i i i i i i i

MODEL INSTALLATION INSTRUCTIONS

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

Smart-UPS X-Series External Battery Pack Installation and Operation

Undertile Heating Mat Installation Manual

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

SOLCAL. 1 digital regulator. 257 series CONTENTS INSTALLATION AND COMMISSIONING MANUAL. Function

ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER KD-90D MODEL INSTRUCTION MANUAL

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

MODEL CA-72 SERIES ACCELERATION TRANSDUCER INSTRUCTION MANUAL

WLC60 Heavy Duty LED Light

Degassed Cation Conductivity

INSTALLATION INSTRUCTIONS

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

INSTRUCTION BOOKLET FOR PALLET DECOILER

Part Number Inches Millimeters " x 8.36" x 1.625" 279 mm x 212 mm x 41mm. 9.25" x 6.75" 235 mm x 172 mm. 9.25" x 7.

Transcription:

Installation Instructions Please Read Before Installing Overview The HWI-WPM-6D-120 and -240 are for use with HomeWorks systems. The modules are programmed with a personal computer using the HomeWorks Utility. Each module controls up to six zones of light. Up to 8 Wallbox Power Modules, each with a unique address, can be linked together on a single configurable link of the HomeWorks Processor. TM Wallbox Power Module HWI-WPM-6D-120 100-127VAC, 50/60Hz HWI-WPM-6D-240 220-240VAC, 50/60Hz HWI-WPM-6D-120 HWI-WPM-6D-240 Important Notes Codes: Install in accordance with all applicable electrical codes. Overheat Damage: To reduce the risk of overheating and possibly damaging other equipment, do not install to control receptacles or motor-operated appliances. Environment: Ambient operating temperature: 0-40 C, 32-104 F, 0-90% humidity, non-condensing. Indoor use only. Spacing: If mounting one module above another, leave at least 4.5" (114mm) vertical space between them. Lamp Type: Wallbox Power Modules are designed for use with permanently installed incandescent, magnetic low-voltage, or tungsten halogen lamps only. For electronic low-voltage, Lutron Fluorescent Dimming Ballasts, 0-10V control fluorescent dimming ballasts, or to increase zone capacity, a separate interface is required. See Interface Guide. Input Voltage Zone Capacity Unit Capacity 100-127VAC 25-800W/VA 2000W/VA 220-240VAC 40-1200W/VA 3000W/VA Low-Voltage Applications: Use the HWI-WPM-6D-120 and -240 with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit with all lamps inoperative or removed may result in current flow in excess of normal levels. To avoid transformer overheating and premature transformer failure, Lutron strongly recommends the following: a. Do not operate low-voltage circuits without operative lamps in place. b. Replace burned-out lamps as quickly as possible. c. Use transformers that incorporate thermal protection or fuse transformer primary windings to prevent transformer failure due to overcurrent. Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions. Wallboxes: Lutron recommends using 3.5" (89mm) deep wallboxes for easier installation. Default Scene Remote: Use only an NTGRX-1S or a momentary switch rated for switching 120VAC (HWI- WPM-6D-120) or 240VAC (HWI-WPM-6D-240). See SSA Wiring Diagram. Interface Guide Load 120V Interface 240V Interface Electronic Low- Voltage Lutron Fluorescent 0-10V Control Fluorescent Increase Zone Capacity ELVI-1000 GRX-FDBI-16A-120 GRX-TVI NGRX-PB-WH HP 2 4 6TM NGRX-ELVI-AU-WH NGRX-FDBI-AU-WH GRX-TVI NGRX-PB-AU-WH 1

Installation 1. Turn power off to all feeds to the module. DANGER - Locate and lock supply breaker in the OFF position before proceeding. 2. Mount wallbox. Use standard 4-gang U.S. wallbox (Lutron P/N 241-400 may be used), 3.5" (87mm) deep is strongly recommended, 2.75" (68mm) deep minimum. Always allow at least 4.5" (110mm) clearance above and below the module to ensure proper heat dissipation. 3. Pull wires. Use the rearmost knockouts when pulling wires into the wallbox. This will provide the most clearance when mounting the module. 4. Line voltage wiring. Strip 0.5" (12mm) of insulation from all line voltage wires in the wallbox and connect them to the appropriate terminals on the back of the module (as shown in the Line Voltage Wiring Diagram). Each terminal can accept up to two #12AWG (2.4mm 2 ) wires (does not apply to Class 2/PELV terminal block). Secure wires using 9 in.-lbs. (1.0 Nm) for line voltage connections and 10 in.-lbs. (1.3 Nm) for the earth/ground connection. See Line Voltage Wiring Diagram (page 3). CAUTION - Do not connect line voltage/mains wiring to Class 2/PELV terminals. CAUTION - Proper short circuit and overload protection must be provided at the distribution panel. You can use up to a 20A (16A for 240V model) maximum circuit breaker/mcb with adequate short-circuit breaking capacity for your installation. 5. Class 2/PELV wiring. Strip 1" (25mm) of insulation from the Class 2/PELV cable. Strip 0.375" (8mm) of insulation from each wire in the cable. Connect the Class 2/PELV wires to the Class 2/PELV terminal block, making sure no bare wire is exposed after making the connections. Secure the wires using 3.5 in.-lbs. (0.4 Nm) of torque for Class 2/PELV connections. See Low-Voltage (Class 2/PELV) Wiring Diagram. CAUTION - The Class 2/PELV cable and terminal block should be separated from the line voltage/mains cables by at least 0.25" (7mm). 6. Mount the module using the screws provided (see Mounting Diagram). When mounted in the wallbox, the Class 2/PELV cable and terminal block should remain separated from the line voltage/mains cables. 7. Turn ON input feed circuit breaker and check that it does not trip. For any feed circuit breaker that trips, locate the short or resolve the wiring problem before proceeding. 8. Use the Address Switch to check the operation of each zone. See Address Switch Operation (page 5). 9. Set each address switch to match the module s address on the link (as programmed in the HomeWorks Utility). See Address Switch Operation (page 5). 10. After the HomeWorks system is programmed, check each module s diagnostic LED (light emitting diode). See Diagnostic LED Status (page 5). Mounting Diagram 4-Gang Wallbox (Lutron P/N 241-400 may be used) 3.28" (83mm) Clearance Module 8.66" (220mm) 4.50" (114mm) clearance, minimum. 5.43" (138mm) Faceplate Side View 0.33" (8mm) 2.13" (54mm) CAUTION - Do not connect the #2 wire to the Class 2/PELV terminal block. See Low-Voltage (Class 2/PELV) Wiring Diagram. 4.50" (114mm) clearance, minimum. 4.98" (126mm) 2

PROCESSOR LINK 1 2 3 4 5 6 G1 V1 G2 V2 G3 V3 G4 V4 G5 V5 G6 V6 Link 7 RS-232 Link PROCESSOR LINK Line Voltage Wiring Diagram Earth/Ground from Distribution Panel #12 AWG Distribution Panel (2) #12 AWG (2) #12 AWG Hot/Live Load 2 Load 4 Load 6 ZONE 2 ZONE 4 ZONE 6 CU WIRE ONLY ZONE 1 ZONE 3 ZONE 5 Load 1 Load 3 Load 5 Neutral Hot/Live #12 AWG HOT/LIVE SSA USA CLASS 2 IEC PELV NEUTRAL Rear View of Wallbox Power Module Neutral #12 AWG Low-Voltage (Class 2/PELV) Wiring Diagram Rear View of Wallbox Power Module ZONE 2 ZONE 1 ZONE 4 CU WIRE ONLY ZONE 3 ZONE 6 ZONE 5 Wallbox Power Modules may be connected to any of these three links depending on the configuration of the HomeWorks Utility. HOT/LIVE SSA USA CLASS 2 IEC PELV NEUTRAL 8 8 Rear View of Wallbox Power Module 12 34 ZONE 2 ZONE 4 CU WIRE ONLY ZONE 1 ZONE 3 ZONE 6 ZONE 5 HOT/LIVE SSA USA CLASS 2 IEC PELV NEUTRAL See Note 1 See Notes 2, 3 & 4 Notes 1. Connection between #2 terminals is not made between Wallbox Power Modules, GRAFIK Eye Control Units, or the HomeWorks Processor. 2. Low-Voltage communications wiring must be daisychained. 3. Total length of wire on a single link may be up to 2000 feet (600m). 4. There may be up to a total of 8 Wallbox Power Modules and/or GRAFIK Eye Control Units per link. 3

SSA Wiring Diagram Earth/Ground from Distribution Panel #12 AWG Distribution Panel ZONE 2 ZONE 4 CU WIRE ONLY ZONE 1 ZONE 3 Hot/Live ZONE 6 ZONE 5 Neutral Hot/Live #12 AWG HOT/LIVE SSA USA CLASS 2 IEC PELV NEUTRAL Rear View of Wallbox Power Module Neutral #12 AWG #12 AWG #12 AWG Default Scene operation using an NTGRX-1S or a momentary switch. Default Scene Operation Pressing the Default Scene Button will toggle the module between the Default Scene and OFF. An NTGRX-1S or a momentary switch may be connected to the SSA terminal on the module to perform the same function as the Default Scene Button (See SSA Wiring Diagram). To program the Default Scene, use the HomeWorks Utility. Default Scene Button Default Scene Status LED 4

0 Address Switch Operation Diagnostic LED Status Position 0 1-8 9 A B C D E F Module Output / Purpose Internal relay ON, all zones OFF Address for normal operation Zone 1 Full ON, all others OFF Zone 2 Full ON, all others OFF Zone 3 Full ON, all others OFF Zone 4 Full ON, all others OFF Zone 5 Full ON, all others OFF Zone 6 Full ON, all others OFF All Zones Full ON LED Status Off 1 blink per second 1 blink per 7 seconds 2 blinks in one second, 2 seconds OFF Mode / Possible Cause No power or defective module Heartbeat Mode; Normal Operation Lighthouse Mode; Not communicating with processor or module set on diagnostic address Program Mode; Module is being programmed 5 blinks per second Rapid Blink Mode; Hardware problem or duplicate address Module Detail - Front View (Faceplate Removed) Diagnostic LED E F D C B A 9 8 1 2 3 4 5 6 7 E F D C B A 9 0 8 1 2 3 4 5 6 7 Address Switch (16-position rotary) 5

Troubleshooting Guide Symptom Diagnostic LED OFF Diagnostic LED is in Lighthouse Mode Diagnostic LED is in Rapid Blink Mode Loads do not respond to keypad button presses Default Scene does not turn on loads properly Cause and Action Power is not present at module: Check to make sure the module circuit is powered Remove module and check wiring The module is not communicating with the processor: Check for open Class 2/PELV wiring Check for shorted Class 2/PELV wiring Check Class 2/PELV wiring for mis-wire Module is set at a diagnostic address (0, 9-F): Set address switch to valid module address (1-8) System not properly configured or addressed in the HomeWorks Utility: Check address in the HomeWorks Utility Upload programming configuration from the HomeWorks Utility terminal Two modules are at the same address: Set modules to proper addresses A module is set to the same address as a GRAFIK Eye Control Unit: Set module or GRAFIK Eye Control Unit to the proper address Module is set at a diagnostic address (0, 9-F): Set address switch to valid module address (1-8) Power is not present at loads: Verify individual zone output using the address switch (9-F) Remove module and check line voltage wiring Keypad is not programmed or addressed correctly: Check keypad programming and address in the HomeWorks Utility Check keypad for proper address Default Scene is not configured properly in the HomeWorks Utility: Check override levels for WPM zones in the HomeWorks Utility Module set at a diagnostic address (0, 9-F): Set address switch to a valid module address (1-8) WPM zone outputs are not assigned loads in the HomeWorks Utility: Assign loads to the WPM zone outputs in the HomeWorks Utility 6

Notes: 7

World Headquarters Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. TOLL FREE: (800) 523-9466 (U.S.A., Canada and the Caribbean) Tel: (610) 282-3800; International 1 610 282-3800 Fax: (610) 282-3090; International 1 610 282-3090 European Headquarters Lutron EA LTD Lutron House 6 Sovereign Close Wapping London, E1 9HW England FREEPHONE: (0800) 28 21 07 (U.K.) Tel: (171) 702-0657; International 44 171 702-0657 Fax: (171) 480-6899; International 44 171 480-6899 Asian Headquarters Lutron Asuka Corporation K.K. 2nd Floor, Kowa Shiba-Koen Bldg. 1-11 Shiba-Koen 1 chome Minato-ku, Tokyo 105-0011 Japan TOLL FREE: (0120) 083 417 (Japan) Tel: (3) 5405-7333; International 81-3-5405-7333 Fax: (3) 5405-7496: International 81-3-5405-7496 Hong Kong Sales Office Tel: 2104-7733; International 852-2104-7733 Fax: 2104-7633; International 852-2104-7633 Singapore Sales Office Tel: 487-2820; International 65-487-2820 Fax: 487-2825; International 65-487-2825 Technical and Sales Assistance If you need assistance, call the toll-free Lutron Technical Support Center. Please provide exact model number when calling. (800) 523-9466 (U.S.A., Canada and the Caribbean) Other countries call: Tel: (610) 282-3800 Fax: (610) 282-3090 Visit our Web site at www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 11/02 P/N 043-098 Rev. A LIMITED WARRANTY Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within two years after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. Telephone the Lutron Technical Support Center toll free at 800-523-9466. After the two year period, a pro-rated warranty applies to this product until eight years after the purchase. For more information regarding this warranty contact your Lutron representative. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO TWO YEARS FROM PUR- CHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, AE, OR IMPROPER OR INCORRECT REPAIR, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUEN- TIAL DAMAGES. LUTRON S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIV- ERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This product may be covered under one or more of the following U.S. patents: 4,835,343; 4,889,999; 4,924,151; 5,170,068; 5,237,207 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, GRAFIK Eye, HomeWorks and the HomeWorks logo are registered trademarks of Lutron Electronics Co., Inc. 2002 Lutron Electronics Co., Inc.