Acoustic and Vibration Isolation for Asylum Research AFMs

Similar documents
For further information about our products and installation services please call to arrange a personal consultation.

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY MATERIALS MANAGEMENT DIVISION

INC Pre-Assembled Structures

IAC Acoustics Moduline Noise Control Enclosures. Mark Simnick

Applied Noise Control. D. W. Herrin, Ph.D., P.E. University of Kentucky Department of Mechanical Engineering

Environmental simulation chamber for cyclical temperature

Rectangular sound attenuator

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

Exceptional Technology for Material Science TT DMA. Dynamic Mechanical Analyser

2D LASER CUTTING SYSTEMS WITH 3000 WATT CO2 LASER

Accutone2 Architectural Enclosures

Verizon NEBS TM Compliance: Freeze/Thaw Test Setup and Procedure Verizon Technical Purchasing Requirements VZ.TPR.9407 Issue 1, October 2007

MIR COOLED INCUBATORS

PLANT GROWTH CHAMBERS 6320, 6321, 6322, 6323, 6340, 6341, 6342, 6343 SERIES

42U SmartRack White Standard-Depth Rack Enclosure Cabinet with doors, side panels & shock pallet packaging

B.O.D. INCUBATOR. Model no.: ACM I TECHNOLOGIES PVT. LTD.

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

MONAIR. Recirculating Fume Cabinet. Low cost, efficient and State-of-the-art design. Reliability and safety assured

S CHEDULE G - D OCUMENTS S UBMITTAL R EQUIREMENTS

Designed for Storage of Noxious and Odorous Evidence

Projector mounts. CMA115 6 (152 mm) CEILING PLATES. concrete. vaulted. CMA330 8 (203 mm) CMA700 6 (152 mm)

Space dividing P100. Features. Surface Options. Specifications. Operable walls

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Agilent Transducer Systems

Which Microstat is right for you?

TABLE OF CONTENT. Equipment kit Description of the technology Installation of equipment Start of construction...

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Air Compressor Series.

Product Data Catalog

Controls and Software CHORE-TRONICS 2 Controls

50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens

LAYHER PROTECT SYSTEM

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

3 News PORTE INDUSTRIALI

SCO Series - Air Jacketed Units. SHEL LAB CO2 Incubators

Controls and Software CHORE-TRONICS 2 Controls

Transfer Air Device Type LDO-T

PO Box Riyadh Kingdom of Saudi Arabia. Tel: / , Fax: Website:

Exterior Wall Solutions Building Shell

QUIET ZONE MODULAR BROADCAST STUDIOS AND VOICE BOOTHS

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

QUIET ZONE MODULAR BROADCAST STUDIOS AND VOICE BOOTHS

ISO 20FT MOBILE FIELD WORKSHOP SHELTER

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES

SECURE.GUARD Ultra low temperature freezer

Smardt Water Cooled Chillers

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

Controls and Software CHORE-TRONICS 2 Controls

Capital Projects Group Air Terminal Units Specification

FITOCLIMA 600 & 1200 BIO

Wood Casework Acid Storage

SECTION The specification section is organized by placing information in three standard parts:

For More Information Contact: Zebra Communications

METALWORKS RH215 Faceted Custom Hook-on Panels

SoftWall Enclosures. Flexible In-plant Enclosure Systems An Excellent Alternative to Rigid Wall Systems

all VAC LIFT ALL-VAC-LIFT Phone Redstart Street Fax

ALARIS CONSOLE ABOUT ALARIS CONSOLE ALARIS CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

SOLUTION FOR BUILDINGS WITHOUT AN ELEVATOR. KONE ProSpace

AIRCOOL VENTILATORS FURTHER INFORMATION

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Developing Positioning Systems for Pathology Scanners

Hysitron TI 980 TriboIndenter. Innovation with Integrity. Tribology and Mechanical Testing

Hysitron TI 980 TriboIndenter. Innovation with Integrity. Tribology and Mechanical Testing

Model FD 23 Drying and heating chambers Classic.Line with forced convection

NEXUS 8000XL Series Universal/Brinell hardness tester

DLE-H LINEAR ENCLOSURE DISPLACEMENT DIFFUSER WITH INTEGRAL HEAT

GARAGE STORAGE & ORGANIZATION

The Stress Limit for your products. Temperature Shock Test Chamber Model TS 130. Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik

ERK Series. features: options: specifications: enclosure. what great systems are built on.

New loading platforms and Hörmann Dock Control. New Loading Technology Products for Innovative solutions for increased efficiency

You dream it. We build it. ELEVATORS

SIDERISE SC cavity barriers & fire stops for suspended ceilings

Low-Head Filters High-Efficiency Polishing Filtration for Water and Wastewater Treatment

Automatic panel bender: Today's solution. For your tomorrow.

Lightning Speed superb acceleration rates with temperature shock test chambers

NEXUS 8000XL Series Universal/Brinell hardness tester

NEXUS 8000XL Series Universal/Brinell hardness tester

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

Model KB 720 Cooling incubators with compressor technology

Tangible heat exchanger savings Just eight steps away! 30% More resource efficient Less refrigerant

Largo & Allegro. Air Compressors. Largo & Allegro

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

NV series. Induction VAV air volume control terminals

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

OVERHEAD SERVICE DISTRIBUTION

Characteristics Mechanical strength Air leakage Filter by-pass leakage Thermal transmittance Thermal bridge factor

PREMIUM VINYL WINDOWS AND DOORS FOR NEW CONSTRUCTION AND REPLACEMENT

AMSCO WARMING CABINET MID-SIZE SINGLE COMPARTMENT

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

185 DISCOVERY DRIVE COLMAR, HATFIELD TOWNSHIP MONTGOMERY COUNTY, PA. 2.9+/- acres. Approximately 38,000 square feet

Options. Single racking cabinet

FITOCLIMA 600 & 1200 BIO

YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE

Servo electric bending technology by Prima Power. The Bend The Combi The Laser The Punch The System The Software

Melhart Music Center Modular Music Practice Rooms - E3 Ready Specifications Section 13034

Transcription:

Vibration Enclosures and Tables Acoustic and Vibration Isolation for Asylum Research AFMs DATA SHEET 01 Isolation from the lab environment plays an important role in image and measurement quality. Our AFM systems inherently have some of the lowest noise specifications in the industry, however, Asylum Research offers a variety of isolation tables and integrated acoustic enclosures that will optimize your AFM s performance in noisy environments. Vibration isolation is required for all MFP-3D AFM systems and is optional for the Cypher AFM. Because each facility environment is different, we recommend prospective users evaluate their available options. As a courtesy to our customers, Asylum Research can provide a site survey kit to quantify the vibration and acoustic noise of your lab prior to your system installation. Acoustic Isolation Enclosures Two different models of enclosures are available for the small and large footprint MFP-3D systems. The enclosures provide excellent acoustic protection, low frequency passive vibration isolation and protect your instrument from air currents. The frame is made of powder-coated steel tubing. The chamber has a powder-coated steel exterior and a proprietary layered interior which provides the ultimate in sound insulation over a wide frequency range. Each enclosure is designed with a front window, an adjustable stand inside for resting the MFP-3D Head while changing cantilevers, two side cable clamps, swiveling casters, and leveling feet. Contact Asylum Research for choices of compatible vibration isolation tables and their dimensions. AEK 2002 The AEK 2002 is a smaller enclosure designed for use with MFP-3D Stand Alone systems (Figure 1). Figure 1: AEK 2002 acoustic isolation enclosure with the MFP-3D Stand Alone AFM inside.

BCH-45 The BCH-45 is designed for the large footprint of the MFP-3D-BIO systems. It provides room to access attachments such as illumination pillars, side mounted cameras, lamp houses, and epi-fluorescence, TIRF, or confocal accessories (Figure 2). Doors open for 180 interior access. Dual front windows open allowing for viewing and quick access and adjustment. Options for Acoustic Isolation Enclosures 1) Air Temperature Control Minimize drift with the AEK and BCH enclosures The Air Temperature Control (ATC) option is available for the both the AEK and BCH enclosures (Figure 3). The ATC controls temperature inside the hood and reduces thermal drift by a factor of 20X-100X, improving AFM drift especially in labs with large temperature swings. The ATC system keeps the air temperature inside of the hood constant around the instrument regardless of the laboratory temperature. A quiet fan draws air into the bottom of a vertical duct in the hood, then forces it through a series of heater coils and expels the warm air above a porous false ceiling which creates a plenum above the AFM. The warm air uniformly flows downward over the microscope where temperature feedback sensors, typically placed near the AFM head and scanner, monitor the hood temperature. The ATC simply plugs into the expansion port in the ARC2 or MFP-3D AFM system controller. Fan speed, temperature setpoint, ramp rate, and heater power are easily controlled through the software interface. (Contact Asylum Research for current specifications and current user upgrades.) 2) BCH-45 Optical Window This optical window can be installed in the BCH-45 enclosure and will protect low-light beams in applications such as fluorescence lifetime imaging, Raman spectroscopy, and single-molecule fluorescence. It fits into a standard or extra cable port location. 3) BCH-45 Extra Ports This is a custom option for researchers needing additional ports in their BCH enclosure. The extra ports can be used for cables or with the BCH-45 optical window option. The port location(s) are subject to review by Asylum Research before ordering. Figure 2: BCH-45 enclosure with a large footprint MFP-3D-BIO system. Porous Ceiling Figure 3: The BCH-45 Enclosure with Air Temperature Control installed including porous ceiling and vertical duct. The ATC reduces thermal drift by a factor of 20X-100X in labs with large temperature changes. Vibration Isolation Tables Vertical Duct Asylum offers two series of vibration isolation tables, the Herzan AVI Series and the Table Stable Series. Either will fit nicely in the matching acoustic enclosures. We recommend the AVI-SA for the MFP-3D Stand Alone and the AVI-BIO for the MFP-3D-BIO.

AVI Series The Herzan AVI Series provides active isolation with six degrees of freedom (Figures 4-6). Continuously senses external vibrations and, through a feedback loop, signals internal actuators to react to compensate for them. Active 1.2Hz to 200Hz; Passive >200Hz 5-20 msec response Virtually no amplification of noise at low frequencies. Will isolate under the most extreme vibration environments. Requires no on-site calibration No compressed air required Comes with rigid table top, isolators and control electronics. Available in a variety of sizes and models (contact Asylum Research for size and enclosure compatibility). Four models available: AVI-SA, AVI-BIO, AVI-BIO-XL, AVI-OCT Table Stable Series The Herzan TS-Series Table Stables (Figure 7) offer a precise automatic level adjustment mechanism that allows convenient handling of different loads without any user intervention. The TS-150 is recommended for use with the Cypher AFM when installed in an especially high vibration environment. In some MFP-3D-BIO systems with external optics, the automatic level adjustment of the TS-series helps stabilize optical alignment. Isolation begins at 0.7Hz, increasing rapidly to 40dB Active 0.7Hz to 1000Hz; passive beyond 1000Hz No low frequency resonance 500X stiffer than air tables Isolation of all six possible translational and rotational modes of vibration with automatic leveling Two models available: The TS-150 for small footprint AFMs and the TS-140 for large footprints No compressed air source required Figure 4: AVI-SA vibration isolation pictured with the MFP-3D Stand Alone AFM. Figure 5: AVI-BIO table for large MFP-3D-BIO footprints; available with XL granite top (not pictured). Figure 6: AVI-OCT table for large MFP-3D-BIO footprints. Figure 7: TS-150 vibration isolation table.

Table I: Vibration Isolation Table and Acoustic Isolation Enclosure Compatibility Table Compatible Dimensions Dimensions Load Weight AFM Model Enclosure (in) (cm) (lbs/kg) (lbs/kg) System AVI-SA* AEK-2002/ 18w x 18d x 3h 45.7 x 45.7 x 7.6 330/150 100/45 MFP-3D-SA ATC-AEK-2002 18 x 12 x 3 45.7 x 30.5 x 7.6 ~95/43 MFP-3D-SA BCH-45 18 x 18 x 3 45.7 x 45.7 x 7.6 100/45 MFP-3D-BIO 1 AVI-BIO* BCH-45/ATC-BCH 24 x 24 x 3 61 x 61 x 7.6 330/150 100/45 MFP-3D-BIO 2 AVI-BIO-XL BCH-45/ATC-BCH 24 x 34 x 4 61 x 86.4 x 10.2 330/150 100/45 MFP-3D-BIO 2 AVI-OCT BCH-45/ATC-BCH 36 x 36 x 4 91.4 x 91.4 x 10.2???? MFP-3D-BIO 2 TS-150 AEK 2002 15.7 x 17.7 x 3 40 x 45 x 7.6 330/150 35/16.5 MFP-3D-SA BCH-45 MFP-3D-BIO 1 Cypher + TS-140 BCH-45 19.6 x 23.6 x 3.3 50 x 60 x 8.5 300/140 60/27 MFP-3D-BIO 2 *Recommended for the MFP-3D-SA and MFP-3D-BIO respectively 1 Small footprint systems 2 Large footprint systems + Cypher inherently has extremely low noise specs, however, use of an isolation table may be needed in especially high vibration environments. Table II: Acoustic Isolation Enclosure Dimensions Enclosure Position Dimensions (in) Dimensions (cm) Weight (lbs/kg) AFM System AEK 2002 Open 30w x 31.5d x 67.5h 76.2 x 80 x 171.5 810/367 MFP-3D-SA Closed 30 x 31.5 x 55.25 76.2 x 80 x 140.3 870/395 (shipping) Inside 21 x 28 x 24 53.3 x 71.1 x 61 BCH-45 Open 90 x 71 228.6 x 180.3 930/422 MFP-3D-BIO 1, 2 Closed 45 x 79 114.3 x 200.7 1365/619 (shipping) Inside 41 x 44 104.1 x 111.8 Please contact Asylum Research for complete facility specifications.

Acoustic Isolation Diagrams AEK 2002 66 30 21 Inside 26 24 Interior 45 55.25 28 31.5 BCH-45 91 45 45 41 Internal Width 42 Internal Height MFP-3D, MFP-3D-SA, MFP-3D-BIO and Cypher are trademarks of Asylum Research 5-2012 6310 Hollister Ave. Santa Barbara, CA 93117 voice: 805-696-6466 fax: 805-696-6444 toll free: 888-472-2795 www.asylumresearch.com info@asylumresearch.com