Poultry Housing and Manure Management Systems : Recent Developments in Italy as Regards Ammonia Emissions

Similar documents
NH 3 Emissions from Poultry Layer Operations

EUROVENT. The ventilated laying battery for exceptional b i rd perf o rmance with dry manure pro d u c t i o n

Forced convection in drying of poultry manure

REDUCTION IN MANURE WEIGHT AND VOLUME USING AN IN-HOUSE LAYER MANURE COMPOSTING SYSTEM UNDER FIELD CONDITIONS

Dust, ammonia and greenhouse gas emissions associated with three housing types for laying hens

Emissions, Regulations and Impact in the European Union and The Netherlands

DRAINING OF SLURRY PITS - A SIMPLE WAY TO REDUCE EMISSIONS FROM PIG HOUSING UNITS

Mitigation of Ammonia Emissions from Poultry

Noxious gases in rabbit housing systems: effects of cross and longitudinal ventilation

NATURA Step. The modern aviary system for barn, free-range and organic egg production

PRACTICAL APPROACHES TO IMPROVE AIR QUALITY OF ANIMAL FEEDING OPERATIONS WITH PROPER FACILITY AND MANURE MANAGEMENT

Air quality in pullet barns

Moisture Production of A Commercial Laying Hen House with Manure Belt

COMPOSTING POULTRY LOSSES

Figure 1. Basic principle of ventilation: fresh air mixes with shelter air contaminants and is discharged. CONTAMINATED AIR OUT MOISTURE MIXING GASES

COMPARISON OF BIOFILTER RESIDENCE TIME

Appendix B: Ratings for the Organic Egg Scorecard

07059, Antalya / TURKEY ABSTRACT

Case Study : The Dynamics of an Organic Compost Operation. Presented by: L. G. (Larry) Conrad, P.Eng. Chair, The Compost Council of Canada

HOW PHYSICAL PROPERTIES OF BIOMASS GRASSES INFLUENCE THEIR PERFORMANCE AS A BEDDING MATERIAL FOR BROILER CHICKENS

Ammonia Emissions and Potential Options for U.S. Poultry Facilities

Improving the Air Quality of Animal Feeding Operations

Relationship between odour intensity and concentration of n-butanol

Victoria's Chicken Egg Industry

AMMONIA EMISSION EVALUATION FROM MANURE MANAGEMENT

Ventilation Rates of a Laying Hen House Based on New vs. Old Heat and Moisture Production Data

Improving the Air Quality of Animal Feeding Operations

SIMPLE AND CHEAP AIR CHANGE RATE MEASUREMENT USING CO 2 CONCENTRATION DECAYS

Best Available Techniques in French pig production Nadine GUINGAND, IFIP Institut du Porc France

AviMaxtransit. The multi-tier system for hygienic, efficient and successful broiler growing

Measures against Ammonia Release in a Floor Housing System for Laying Hens

Windrowing Poultry Litter Pros and Cons

Ammonia and Greenhouse Gases Concentrations and Emissions of a Naturally Ventilated Laying Hen House in Northeast China

Equipment for Floor Systems

Durum wheat growth analysis in a semi-arid environment in relation to crop rotation and nitrogen rate

Passively Aerated Composting of Manure Slurry

TECNO: THE SOLUTION AT HAND.

Issues and Challenges in Broiler Production. Richard L. Lobb Director of Communications National Chicken Council

FDI Condo Enrichable Stacked Layer Cage Features & Benefits (Many other cage sizes and number of tiers available upon request)

Ammonia Emissions from U.S. Laying Hen Houses in Iowa and Pennsylvania

Measurement and Modelling of Circumstances in Animal Houses: What, Why and How

Agricultural and Biological Engineering. Biological Manipulation of Manure: Getting What You Want from Animal Manure

Biofiltration is. The average odor. Treating Odor Emissions from Buildings Biofilters

Impact of EU and national legislation on production cost for broilermeat and eggs.

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Precision ventilation to improve indoor air quality and reduce emission in pig housing

EMISSION FACTOR DEVELOPMENT FOR PARTICULATE MATTER FROM A BROILER HOUSE

Footpad lesions in broiler chickens

Effect of Reducing CP Content on NH3 Emission of High-Rise Layer Houses

Propane Saving in Poultry Farm through Waste Heat Recovery System

Management, Handling, Transfer, Storage and Treatment of Manure and Litter from Poultry Production Facilities

ELODIE: A Tool for the Environmental Assessment of Building

Heat and Moisture Production of Hy-Line Brown Hens in Aviary Houses in the Midwestern U.S.

D. Reduced emission manure storage techniques

XVII th World Congress of the International Commission of Agricultural and Biosystems Engineering (CIGR)

Emissions of NH 3, N 2 O and CH 4 from composted and anaerobically stored farmyard manure

OTA DRAFT COMMENTS AT-A-GLANCE

Environmental Control for Poultry Buildings in Riyadh Area of Saudi Arabia

INFOSheet. Introduction. Do These Problems Sound Familiar?

22 Manure management, hygienic conditions and greenhouse gas emissions in dairy farms using recycled manure solids as bedding for cows

MINIMUM DISTANCE SEPARATION (MDS II) GUIDE FOR NEW OR EXPANDING LIVESTOCK FACILITIES AND/OR MANURE STORAGES

National Organic Standards Board Livestock Committee Animal Welfare Discussion Document Stocking Density. September 9, 2010

AIR EMISSIONS FROM TWO SWINE FINISHING BUILDING WITH FLUSHING: AMMONIA CHARACTERISTICS

Ammonia Emissions from Two Empty Broiler Houses with Built-Up Litter

Livestock climate control systems as a potential ammonia abatement technique

Influence of Temperature, Humidity and Ventilation Rate on the Release of Odour and Ammonia in a Floor Housing System for Laying Hens

Sector Guidance Note. How to comply with your environmental permit for intensive farming EPR Introduction and chapters

COMMISSION OF THE EUROPEAN COMMUNITIES COMMISSION WORKING DOCUMENT

Manure Production and Management Record Keeping Forms

Electricity and Fuel Use of Aviary-Laying Hen Houses in the Midwestern United States

Ventilation performance measurement of a decentralized mechanical system with heat recovery using Tracer gas decay method

Slurry Grass Crops. Soil. Water. Livestock. The Environment

Cattle Housing and Ventilation

Ammonia emission from organic pig houses determined with local parameters

AA22 Animal Science II Unit C Animal Management

The microbiological environment in specific rooms of a university campus

Comparative evaluation of three egg production systems: Housing characteristics and management practices

VERA Test Protocols: general overview of main revisions

Made in Germany. Enriched cage system. Enriched laying cage types

MINIMUM DISTANCE SEPARATION (MDS 1) GUIDE FOR NEW NON-AGRICULTURAL USES ADJACENT TO EXISTING LIVESTOCK

HVAC and lighting: Reducing energy costs in poultry farming

Ammonia Emissions from Two Empty Broiler Houses with Built-Up Litter

Effect of Agro Clima Unit on ammonia emission from broiler houses

Tab 1a. Pigs Data Entry and Assumptions (April 26, 2018)

APPLICATION GUIDE. environmental products inc.

Monitoring thermal conditions during transport of racing pigeons on a vehicle equipped with controlled ventilation

FUMIGATION OF A SILO BIN WITH A MIXTURE OF MAGNESIUM PHOSPHIDE AND CARBON DIOXIDE BY SURFACE APPLICATION

Airborne dust control for floor housing systems for laying hens

Revised Best Available Techniques (BAT) Reference Document for Intensive Rearing of Poultry or Pigs (IRPP BREF)

APPENDIX - A A STUDY ON PRODUCTION, MARKETING AND FINANCIAL PERFORMANCE OF POULTRY FARMS IN NAMAKKAL DISTRICT, TAMILNADU INTERVIEW SCHEDULE

Ford Dickison (2000) Inc., 53 Wellington St., S. Mitchell, ON Canada N0K 1N0 Tel: or Fax:

VERA TEST PROTOCOL. for Livestock Housing and Management Systems. Version 3:

Working Group Agriculture and Environment March 2011 Agri-environmental data needs

Proposal for Cumulative Effects Assessment (CEA) in Air Approvals

EFFECTS OF POULTRY BUILDING DESIGN ON INDOOR AIR QUALITY IN HUMID CLIMATES ABSTRACT

Moving Floor Concept. patented new technology for automatic cleaning in pig barns. No water Improved hygiene Increased profitability

Proportions of Calf Raising Cost. Calf Housing Costs (Birth to Weaning) Hutches. Calf Housing Hutches with protection for worker

Detecting Ammonia in Poultry Housing Using Inexpensive Instruments

MANAGING BUILT UP LITTER

Transcription:

Poultry Housing and Manure Management Systems : Recent Developments in Italy as Regards Ammonia Emissions Bâtiments avicoles et systèmes de gestion des déjections : développements récents en Italie, en lien avec les émissions d ammoniac. F. da Borso, R. Chiumenti University of Udine, Department of Crop Sciences and Agricultural Technologies, Section of Agricultural Engineering, Via delle Scienze, 208-33100 Udine, Italy E-mail : Francesco.daborso@dputa.uniud.it Abstract Laying hen and broiler keeping systems strongly developed during the last years, aiming to the reduction of environmental impacts (especially of emissions in atmosphere) and to make easier poultry manure management. As concerns broiler structures, no advances technologies are applied, but simple management systems can significantly reduce ammonia and odour emissions ; to give an example, the adoption of an adequate height of litter layer and the use dropcollecting drinking nipples allowed a reduction of ammonia level to 6 ppm, in respect to about 20 ppm of the «traditional» system tested. As concerns the laying hen compartment, several studies on the vertical batteries with manure drying on belts were carried out, showing a sufficiently improved management of poultry manure. Therefore, the possibility of reaching higher levels in dry matter of manure must be closely examined. Keywords : poultry manure, ammonia and odour emission, drying, composting. Résumé De nombreux systèmes ont été développés récemment dans le but de réduire l impact environnement (notamment les émissions atmosphériques) et de faciliter la gestion des déjections avicoles (fumiers de volailles et pondeuses). En ce qui concerne les bâtiments volailles de chair, de simples mesures permettent de réduire les émissions d ammoniac telles que l épaisseur de la litière et l amélioration des systèmes d abreuvement. En ce qui concerne les bâtiments de pondeuses, plusieurs études sur le séchage ont montré leur efficacité. Cependant ces systèmes ne permettent pas d obtenir un taux de matière sèche du produit au delà de 50% ; ce séchage incomplet s accompagnant de nuisances olfactives et d émissions d ammoniac au cours du stockage et de l épandage. Mots-clés : fumier volailles, ammoniac et odeurs, séchage, compostage. 15

1. Introduction Modern poultry breeding techniques have been developed with the purpose of improving farm productivity, automation and environmental impacts, both indooors (i.e. animal health and welfare, workers safety) and outdoors (i.e. preservation of soil, water and air quality and their related ecosystems). Several studies which dealt with housing and manure management systems have been carried out by our Department in order to have an insight into these aspects. The aim of the present work is to review different housing and manure handling systems which are adopted in broiler and laying hen sectors, as far as ammonia emission are concerned. 2. Materials and methods During a period of 3 years and taking several technical, environmental, energy and economic parameters into account, the following full scale poultry barns were monitored at a full scale : I. broiler litter bed floor houses, II. laying hen houses with different types of batteries and manure drying systems, III. alternative-to-cage systems for laying hens (litter bed and perches), IV. laying hen houses with manure drying and storage in deep pit. When the housing systems were characterized by natural ventilation (systems I and III) ammonia concentration were measured with a photo-acoustic infrared instrument, the Bruel & Kjaer 1320 with 1303 Multiplexer; air samples were taken in several points inside the barn in order to calculate the mean indoor ammonia concentration. Ammonia emissions were calculated basing on airflow rate estimate by means of the carbon dioxide balance method; the carbon dioxide produced by animals was estimated at 41 ml CO 2 per kj of the total heat produced by one bird (Albright, 1990). Under artificial ventilation conditions (systems II and IV), ammonia concentrations were measured with the above mentioned instrument; however, air samples were taken in the airflow at the fan oulets. Ammonia emissions were calculated basing on airflow rate measurements by means of hot-wire and magnetic transducer anemometers. Further details on sampling points and frequencies will be given in the specific paragraphs. 16

3. Broiler houses Most of the broiler produced in Italy are bred on litter bed in floor barns. Several experimental tests were carried out by our Department with the purpose of improving litter management in these housing systems, i.e. litter material, height of the layer, number of birds per m 2, drinking and eating equipments, litter discharge and storage methods, etc.; aim of the present review is to quantify the effects of different drinkers on ammonia emissions. With regard to this aspect, tests were carried out in 2 barns which were identical in reference to the number of animals (12,800 birds each), the size (12 m x 99 m each) and the litter material (wood sawdust). Hence, it was possible to compare ammonia levels in the air from barn equipped with nipple drinkers with those from the barn equipped with nipple drinkers plus bowls, used for preventing water dropping. Indoor air was hourly sampled during a period of 9 days in summer; ammonia concentrations were significantly lower in the barn with nipple drinkers + bowls, apparently because of a lower moistening of litter below drinkers. The mean airflow rate was estimate to be 2.4 m 3 h -1 bird -1 ; this estimate showed ammonia emissions of 0.657 and 0.404, for the nipple and nipple + bowl drinkers respectively (Table 1). Drinker type Birds / drinker, Estimated ventilation rate, Ammonia concentration, Ammonia emission, number m 3 h -1 bird -1 mg m -3 Nipples 6.5 2.4 11.4 0.657 Nipples + bowls 12.4 2.4 7.01 0.404 Table 1 Results of ammonia determination in broiler barns 4. Laying hen batteries with manure drying In Italy, a large number of laying hens are kept in new types of batteries which allow a partial drying of manure on the conveyer belts. Since 1991, the following manure drying systems were studied by our Department : - air moved by a system of paddles over the belts (Salmet Ô); - air blowed by fans through holed air-ducts over the belts (i.e. Valli Ô); - air sucked by fans into tunnels over the batteries where manure belts flow (Farmer Ô). During a period of 1 year, several parameters (i.e. manure characteristics, energy consumption, environmental aspects, etc.) were monitored in full scale barns characterized by different manure drying systems. With regard to ammonia emissions, results are shown in Table 2. 17

Manure drying system Ammonia emission in winter, Ammonia emission in summer, Paddle system 0.031 0.172 Air blowed in holed ducts 0.027 0.157 Air sucked in tunnels 0.027 0.134 Table 2 Results of ammonia determinations in laying hen barns characterized by different manure drying systems Ammonia emissions from barns equipped with fan drying system batteries were lower than those from barns characterized by paddle drying system batteries, both in winter and in summer. However, it must be noticed that ammonia emissions from all the 3 manure drying systems were considerably lower than those usually shown by batteries without any drying system. In fact, previous studies concerning barns which adopted stair-step cage batteries with gutters and scrapers for manure removal showed that ammonia emissions were about 0.18 in winter and up to 0.70 in summer. 5. Alternative-to-cage systems for laying hens Housing systems where laying hens are not confined in cages are present in several European Countries. Until today, these systems have assumed a relatively little importance in Italy, but the interest in them is growing especially in relation to the animal welfare requirements as well as to the egg marketing advantages. Because of this increasing importance, an experimental research was carried out fucusing on the environmental requirements which these alternative systems have to meet. During 3 weeks in spring, two alternative poultry barns were monitored; they were identical in relation to the ventilation system (natural ventilation), the relative surface of the bed floor and the perches to the total surface (the litter bed floor was 1/3 of the total surface), the animal density (7 birds m -2 ), but they differed from each other in the age of breeding animals; one barn kept pullets, the other laying hens. The mean indoor ammonia concentration was higher in laying hen barn than that one in pullet barn; the estimated ammonia emission was 0.262 and 0.192 g day -1 bird -1, for laying hens and pullets respectively (Table 3). 18

Type of birds Ammonia Concentration, mg m -3 Estimated ventilation rate, m 3 h -1 bird -1 Estimated ammonia emission, Pullets 5.4 1.48 0.192 Laying hens 7.0 1.56 0.262 Table 3 Results of ammonia determination in alternative-to-cage housing systems for laying hens 6. Laying hen housing systems with deep pit storage The housing system with deep pit storage is characterized by a subdivision of the barn into two levels: laying hens are kept in stair-step cages at the raised-floor, while poultry manure is stored at the ground floor during the whole hen production cycle (over 12 months). A mechanical ventilation system allows both the air changing at raised-floor and a partial drying of poultry manure at the ground floor. The inlets of fresh air are located under the eaves, while the suction fans are placed at the ground floor on the side walls. Hence, the air coming from the upper level can pass through the mesh floor and/or through the batteries and it can flow on the manure piles at the ground floor. An outstanding research which is presently being conducted by our Department deals both with ammonia emissions from this kind of housing system and manure characteristics during and after the storage period. Tests are being carried out in two barns which are characterized by identical size but different types of floor on the service passages between the batteries; in one poultry barn there is a wiremesh floor and hence the air can pass both the mesh floor and the cages, while in the other there is a solid floor which allows the air to pass only through the cages. Preliminary results have shown that the ammonia emissions from laying hen housing systems with deep pit storage are higher than those from the other housing systems (0.870 0.626, for wire-mesh floor and solid floor respectively, Table 4). Floor type in the corridors Ammonia emission Wire mesh floor 0.870 Solid floor 0.626 Table 4 Results of ammonia determinations in laying hen houses with deep pit storage 19

7. Discussion and Conclusions Several experimental studies have been carried out by our Department with the purpose of quantifying the effects of different housing and manure management systems on air quality, and in particular on ammonia emissions. Ammonia emissions from poultry barns were important especially in summer. If we consider that the initial nitrogen concentration in laying hen manure is 45 g total N kg -1 dry matter, the calculated nitrogen losses as ammonia emissions ranged from about 6.1 to 39.6% of the total initial manure nitrogen. Regarding the final nitrogen content in broiler litter as 35 g total N kg -1 dry matter, the ammonia emissions caused losses which ranged from 22,8 to 32,7% of total final litter nitrogen. Drinking equipments for broilers influenced litter bed moisture and consequently ammonia production from the barns. Ammonia emission from broiler barns where drinkers for water loss prevention (i.e. nipples + collecting bowls) were adopted, presented a 38.5% reduction, in comparison with those from broiler barns characterized by simple nipple drinkers. Ammonia emissions were reduced down to 80% by timely poultry manure drying inside the barns, in comparison with ammonia emissions from stair step batteries without any manure drying systems and a twice-a-month manure removal by scrapers. Ammonia esmissions from the alternative-to-cage systems were higher than those from the above mentioned cage systems, but in the same time they were lower than those from the litter bed housing systems for broilers. Ammonia emission from the housing systems where poultry manure is stored in deep pit were the highest, ranging from 0.62 to 0.87, certainly due to the long term indoor storage (13 months); moreover, sensible seasonal effects on ammonia emission could be expected. Lastly, it must be considered that the storage of poultry manure inside the barns played an important role on emissions, as regards some of the systems above described. For this reason, further studies should be necessary in order to determine the global ammonia emissions from the different housing and manure management systems. For example, considering the poultry manure produced in broiler and laying hen cage barns, it should be necessary to quantify the ammonia losses which can occur during manure storage outside the barns. 20

8. References Albright, L.D. Environment control for animals and plants (DeVore-Hansen, P. ed), Michigan: ASAE, 1990, pp 166-169. Chiumenti, R.; da Borso, F.; Pinosa, M. Layer keeping systems with manure drying on belts: environmental effects. Proceedings 19 th WPSA Congress 20-24 September, Amsterdam, The Netherlands 1992, (3): 282-288. Climatization of Animal Houses, Report of working group of C.I.G.R. Commission Internationale di Génie Rural, 1984, pp 1-27. Da Borso, F.; Chiumenti, R.; Lenarduzzi, M. Sistemi alternativi alle gabbie per l allevamento delle galline ovaiole (Alternative-to-cage housing systems for laying hens). Proceedings of 6 th National Congress of Agricultural Engineering of AIIA 10-12 September, Ancona, Italy, 1997, (2): 453-462. Feddes, J.J.R.; Leonard, J.J.; McQuitty, J.B. Carbon dioxide concentration as measure of air exchange in animal housing. Canadian Agricultural Engineering 1984, 26: 53-56. Groot Koerkamp, P.W.G. Review on emission of ammonia from housing systems for laying hens in relation to sources, processes, building design and manure handling. Journal of Agricultural Engineering Research 1994, 59: 73-87. 21