Boundary-breaking acoustic focusing cytometry

Similar documents
flow cytometry reinvented

Attune NxT Acoustic Focusing Cytometer The next generation in acoustic cytometry

NovoCyte Flow Cytometer

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

Cancer inflammation research applications and products

Flow Cytometry - The Essentials

Each question may have MULTIPLE correct answers. Select all that are correct.

PowERFUL. INTUITIvE. customizable. ThE NEw STAR of. BENchToP FLow cytometry

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Flexible, Intuitive and Affordable

Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer

FLOW CYTOMETRY. CyAn ADP. Analyzer

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Proceedings of Meetings on Acoustics

What you need to know before designing a panel

NovoCyte Quanteon F. Flow Cytometer. When Exceptional Performance Meets Simplicity

No-wash, no-lyse detection of phagocytic cells via a phrodo BioParticles functional assay in human whole blood on the

BD LSRFortessa. Performance without peer, choice without compromise

Spherotech, Inc. 1. SPHERO TM Technical Note STN-8 Rev C

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

Attune TM Acoustic Focusing Cytometer Training. Manik Punj Attune Training

GUAVA EASYCYTE SYSTEMS

Designing and Implementing a High-Level Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington

Your Research, Revolutionized

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY

INTRODUCTION TO FLOW CYTOMETRY

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Using Fluorescence Spillover to Advantage

Everything counts. But nothing counts like the

Best practices in panel design to optimize the isolation of cells of interest

Your Research, Revolutionized

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

Flow Cytometry. Flow Cytometry Basics Guide

Novel Developments in Cytometry. Martin Adelmann Marketing Manager Cellular Analysis & Life Science Beckman Coulter EMEAI

CyFlow Cube series Appealing from every angle

DURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH. For Reseach Use Only - Not for use in Diagnostic procedures

BD FACSMelody. Cell Sorter. The simple solution for consistent, quality results

Anatomy of a flow cytometer

Cellometer Vision CBA

determine optimum instrument settings for their own instruments and establish their own daily values.

Principles of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

Guava easycyte Systems Expanding the potential of flow cytometry

Expanding Multicolor Options in Flow Cytometry with Novel Brilliant Violet TM Fluorophores. Carsten Wiethe Scientific Application Manager BioLegend

Phagocytosis Assay Kit (IgG PE)

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences

Flow cytometry analysis of transcription factor expression during differentiation of hpsc-derived cardiomyocytes

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Flowcytometry Dirk Pacholsky

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Principles of Immunophenotyping

BD Multicolor CompBeads

Guava EasyCyte Systems Expanding the potential of flow cytometry

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

ANAT 3231 Cell Biology Lab12 Stem Cell Analysis

A previous ICCS Module entitled Instrument optimization - Adjusting PMT voltages and compensation 1 should be read as a prerequisite to this module.

BASICS OF FLOW CYTOMETRY

Flow cytometry within reach.

See what you ve been missing

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

a Beckman Coulter Life Sciences: White Paper

BD LSR Cell Analyzer. Performance without peer, choice without compromise

Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) Annotation

Welcome to More Choice. Mouse Panels

Spherotech, Inc Irma Lee Circle, Lake Forest, IL 60045

CyFlow Space. Your Flexible Flow Cytometer.

a Beckman Coulter Life Sciences: White Paper

Selecting Reagents for Multicolor Flow Cytometry

Application Note. Introduction. EMD Millipore is a division of Merck KGaA, Darmstadt, Germany

CLEARLLAB LS LYMPHOID SCREEN REAGENT

Flow Cytometry Support Reagents

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

CyFlow Space Your flexible flow cytometer

Hematopoietic Progenitor Cell Product Characterization

PERFECT-COUNT MICROSPHERES

a Beckman Coulter Life Sciences: White Paper

Flow Cytometry Immune Activation SOP

CyFlow Space Your flexible flow cytometer

Definitions. What functions does a flow cytometer be able to do? The build of the Flow cytometry and sorting. Flow cytometry

SOPVII-7. Panel X: NK-characterization

Introduction to. BD FACSAria TM Cell Sorter. Flow = Fluid Cyto = Cell Metry = Measurement

SA3800 Spectral Analyzer

Flow Cytometry SOP: Monocytes from Frozen Cells

Attune NxT Flow Cytometer

Understanding Flow Cytometry

Navios Now Because Every Event Matters

Designing and executing a successful flow cytometry experiment

High-dimensional flow-cytometric analysis of human B-cell populations

seminar

The Basics of Flow Cytometry

Institute of Science & Technology in Medicine Control of Substance Hazardous to Health COSHH assessment

Immuno-oncology research

Attune NxT Flow Cytometer. Efficient. Flexible. Transformative. Flow cytometry instrument

For detecting mitochondrial membrane potential changes in cells using our proprietary fluorescence probe.

SOPVII-7. Panel VII: Treg-FACS-staining

Compensation: Fundamental Principles

Review of techniques in imaging and cytometry. Peter Meeus Onze Lieve Vrouw Ziekenhuis, Aalst 7 may 2009, SCK/CEN Mol

Transcription:

Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab

One of the main projects in my laboratory is focused on the description and functional analysis of an emerging innate lymphoid cell type. These cells are extremely rare both in blood and in tissues. For flow cytometry analysis we use the Attune Acoustic Focusing Cytometer. The high sample rates of the Attune cytometer allow me to reduce centrifugation steps so that we retain more cells and more rapidly detect rare events. We could not have performed these studies with any other instrument. Prof. David Cousins University of Leicester

MHCII Pacific Blue CD8 Alexa Fluor 7 CD8 Alexa Fluor 7 CD25 APC B22 Pacific Orange Counts Rapid, accurate detection of rare events The Attune NxT Acoustic Focusing Cytometer is a benchtop analyzer that uses a revolutionary technology, acoustic focusing, to align cells prior to interrogation with a laser for your multicolor flow cytometry analysis. The system offers: Unique modular design one-day field upgradable system with configurations from 1 4 lasers, with the ability to detect up to 14 colors Fast detection speed short acquisition time without loss of data quality enables unique applications such as rare event detection and use of no-wash/no-lyse techniques Distinctive acquisition and analysis software intuitive and powerful for users of all experience levels Convenient size complete setup fits on even small benchtop space Multicolor analysis in a modular design With the option to be configured with up to 4 lasers and 14 colors for multiparameter analysis (Figure 1, the Attune NxT Acoustic Focusing Cytometer was designed as a modular system to fit most experimental design needs and lab budgets. The Attune NxT cytometer can be designed to accommodate the most common fluorophores and fluorescent proteins used in flow cytometry to match the panels you are currently running (Table 1. Multiple fluorescent proteins can be detected with an optional 561 nm laser (Figure 2. Whether you configure your system now or upgrade later, the Attune NxT Acoustic Focusing Cytometer can grow with you and your research needs. A 1, B 1 C 5 Side scatter 75 5 25 75 1, Forward scatter CD45.2 APC-Cy 7 1 6 CD PerCP-Cy 5.5 1 D 6 E F G CD11c PE-Cy 7 1 6 CD11b FITC CD4 Pacific Green 1 2 1 1 1 Foxp PE Figure 1. Multiparameter (1-color analysis of murine regulatory T cells and dendritic cells with the Attune NxT Acoustic Focusing Cytometer. Lymphocytes were gated using FSC/SSC parameters (A, left and B22-expressing B cells were omitted from subsequent analysis (A, middle. Within the B22, CD45.2 + gate, T cells were analyzed based on their expression of CD (A, right. CD + T cells were separated into two populations based on expression of the co-receptors CD4 or CD8 (B, left. Within the CD4 + T cells there is a subpopulation of suppressive regulatory T cells that express the transcription factor Foxp and the cell surface marker CD25 (IL-2Rα (B, right. CD cells were separated to show a rare population of CD11c + MHCII +, professional antigen-presenting dendritic cells (C, left. Splenic dendritic cells can be subdivided further into CD11b + and CD8 + dendritic cell subsets (C, right, each possessing unique antigen presentation properties.

Superior reliability and maximum signal efficiency The novel design of the optical path helps ensure precise fixed alignment of four spatially separated lasers onto the sample stream enabling consistency in data over time, superior performance, and superior reliability. The instrument can be configured with up to 4 solid-state lasers (45 nm, 488 nm, 561 nm, and 67 nm with flat top beam profiles to minimize the effects of changes in fluidics or optics, which cause instability and alignment issues leading to instrument downtime. The light emitted from cells in the flow cell is transported with high efficiency to the detection optics through fiber-optic cables with minimal loss of signal. The filters in front of the photomultiplier tubes collect light signals and can be easily interchanged and customized to minimize reagent crosstalk and maximize signals (Figure. What is acoustic focusing? The Attune NxT Acoustic Focusing Cytometer uses ultrasonic waves (over 2 MHz, similar to those used in CellLight Nucleus-GFP, BacMam 2. 1 2 1 2 CellLight Plasma Membrane-RFP, BacMam 2. Figure 2. Live-cell fluorescent protein detection. U2OS cells were simultaneously transduced with Cellight Nucleus-GFP (Cat. No. C162 and CellLight Plasma Membrane-RFP (Cat. No. C168. Cells were analyzed on the Attune NxT Acoustic Focusing Cytometer using a 488 nm laser and 5/ emission filter along with a 561 nm laser and 585/16 nm emission filter. Table 1. Attune NxT Acoustic Focusing Cytometer fluorophore selection guide. Laser Excitation Emission Common dye Fluorescent protein Violet Blue Yellow Red 45 nm 488 nm 561 nm 67 nm 44/5 Pacific Blue TM ECFP 512/25 Pacific Green TM 6/48 Pacific Orange TM 71/5 Qdot 75 488/1 FSC 488/1 SSC*** 5/ FITC EGFP, Emerald GFP 574/26* Propidium iodide EYFP 59/4** Propidium iodide Fluorescent proteins 695/4 PerCP-Cy 5.5 78/6 PE-Cy 7, Qdot 8 EYFP 585/16 PE RFP 62/15 PE-Texas Red mcherry, dtomato, DsRed, mstrawberry 695/4 PE-Cy 5.5 78/6 PE-Cy 7 67/14 APC 72/ Alexa Fluor 7 78/6 APC-Alexa Fluor 75 *Without a yellow laser present **With a yellow laser present ***Side scatter can be detected by any laser line (default is blue laser. Violet side scatter is recommended for no-wash/no-lyse applications.

A. Acoustic focusing = better precision Acoustically focused sample stream Laser (cross-section device Figure. Example filter configuration for the Attune NxT Acoustic Focusing Cytometer. Filters are easily interchanged to create customized configurations to meet your experimental needs. medical imaging, rather than hydrodynamic forces, to position cells into a single, focused line along the central axis of a capillary (Figure 4. Acoustic focusing is largely independent of the sample input rate, enabling cells to be tightly focused at the point of laser interrogation regardless of the sample-to- ratio (Figure 5. This, in turn, allows the collection of more photons for high-precision analysis at superior volumetric sample throughput. The Attune NxT cytometer accomplishes this without high-velocity or high-volumetric fluid, which can damage cells. In addition, volumetric syringe pumps enable absolute cell counting without beads minimizing cost and sample preparation time. In contrast, cytometers that use hydrodynamic focusing maintain the same sample speed at all flow rates, causing cells to lose focus as the sample core widens to increase flow rate. B. Traditional hydrodynamic focusing: compromised data quality Hydrodynamic core Laser (cross-section Figure 5. Acoustic focusing vs. traditional hydrodynamic focusing as particles pass through the laser. (A In acoustic focusing, cells remain in tight alignment even at higher sample rates, resulting in less signal variation and improved data quality. (B In traditional hydrodynamic focusing, increasing the sample rate results in widening of the sample core stream, resulting in increased signal variation and compromised data quality. Dilute your samples, not your data quality Washing and lysis of red blood cells (RBCs can cause significant cell loss and damage. Significantly higher sample collection rates allow the Attune NxT cytometer to deliver a no-wash/no-lyse protocol to minimize cell loss and simplify sample preparation (Figure 6. This feature is particularly useful for samples that are inherently low in concentration. Dilute samples like cerebrospinal fluid (CSF, stem cells, and any sample with low cell numbers can take a long time to acquire. With the Attune NxT cytometer, even dilute samples can be acquired quickly and without compromising data. Difficult-to-collect samples like Figure 4. Acoustic focusing in action. Fluorescent microspheres were applied to the capillary system of an acoustic focusing cytometer. Beads flow through randomly without any acoustic focusing (left. With the acoustic focusing, the beads are focused into a single line (right.

Gated on on live live CD19 CD19 cells at collection rate cells of 5 at μl/min collection rate of 5 ul/min Figure 6. Eliminate sample preparation without compromising data quality. Five microliters of whole blood was stained with antibodies, incubated, and diluted using 4 ml of buffer and analyzed on the Attune NxT cytometer. 45 nm light is readily absorbed by red blood cells and enables use of the differential side scatter gating shown in the middle panel in which a 45 nm vs. 488 nm side scatter dual parameter plot is used to differentiate the leukocyte and red blood cell populations. From this gated population, a daughter plot of forward and side scatter can be used to identify lymphocyte, monocyte, and granulocyte populations without the need for a fluorescent label. mouse blood and bone marrow, thin-needle aspirates, or any sample with low cell yield can be stained and then diluted without washing or performing RBC lysis. High sample collection rates make acquisition possible you can run up to 4 ml in just 4 minutes. Sample loss is minimized in sample preparation, and full panel testing is possible for all precious samples. Rapid detection of rare events Analysis of rare cell populations requires the collection of high numbers of events in order to attain a reliable measure of accuracy, leading to long acquisition times. The Attune NxT Acoustic Focusing Cytometer achieves sample throughput at rates over 1 times faster than other cytometers up to 1, μl/min and 2 x 1 7 events per run, enabling rapid detection of rare events with reliable accuracy and without aborting data (Figure 7. Precision and sensitivity at all sample rates The Attune NxT Acoustic Focusing Cytometer enables high sensitivity when you need it most. You will be able to maintain precise alignment, even at high sample rates of up to 1, μl/min. The precise alignment provided by acoustic focusing enables researchers to obtain tighter CVs to better distinguish between dim signals and background, resulting in less variation and better signal separation (Figure 8. CD45R/B22-PE fluorescence 1 6 1 2 1 2 1 6 CD17-Alexa Fluor 488 fluorescence Figure 7. Collection of more than 1 million live cells and detection of a rare population (.2% of dendritic cells. Plasmacytoid dendritic cells (pdcs are a specialized cell population that produces large amounts of type I interferons in response to viruses and are identified using the immunophenotype CD19 /B22high/CD17 +. Four-color staining of mouse splenocytes included CD19-Pacific Blue, CD17-Alexa Fluor 488, CD45R/B22-PE direct conjugates, and SYTOX AADvanced Dead Cell Stain. A gate was made on live cells using SYTOX AADvanced Dead Cell Stain, followed by gating on CD19 cells. A two-parameter plot of CD45R/B22 vs. CD17 was used to identify pdcs. A collection rate of 5 μl/min was used to acquire 1. million total cells with a cell concentration of 7.5 x 1 7 cells/ml. Plasmacytoid dendritic cells were identified as dual B22 + /CD17 + (upper right quadrant and constitute.851% of live CD19 cells, which is.194% of total splenocytes. Minimal data variation Cell cycle analysis is just one example of where it is critical to precisely detect differences in fluorescence intensity between multiple cell populations. With the Attune NxT Acoustic Focusing Cytometer, minimal variation in results is seen regardless of sample throughput rate. You no longer need to sacrifice throughput for sensitivity (Figure 9. Software that performs to your specifications Attune NxT software is designed to provide powerful data acquisition and analysis using an intuitive, userfriendly interface (Figure 1. Experiments can easily be set up, customized, and saved for future studies. Compensation is automated and can be set up using a guide.

The software is designed to maximize efficiency in performing data analysis, with fast refresh rates for large data sets (up to 2 million events per sample with the ability to immediately visualize changes on data plots as you make adjustments. The software has unique tools to simplify experimental setup, including reagent selection using the filter configuration manager. This provides guidance for matching the right reagent to the optimized channel on the instrument by selecting reagents from a drop-down menu of prepopulated or customized reagents, which is then applied to plot labels. 241 12.5 μl/min µl/min 25 μl/min µl/min 264 292 μl/min µl/min ul/min 5 μl/min µl/min 4 A B 4 μl/min µl/min 1, μl/min µl/min ul/min 11 12 1 14 15 Conventional flow cytometer (Highest sensitivity = ~12.5 μl/min 12 1 14 15 16 Attune NxT cytometer (12.5 μl/min 869 75 5 C Sample rate (μl/min 12.5 25 5 1, G 1 CV% 2.99. 2.76 2.94 2.7 2.96 G 2 /G 1 1.99 1.99 1.99 2.5 2.5 2. 25 12 1 14 15 16 Attune NxT cytometer (5 μl/min Figure 8. Sensitivity measurements across flow rates. Fluorescent microspheres (Spherotech Rainbow Calibration Particles,.2 μm were run on (A a high-end conventional flow cytometer and (B, C on the Attune NxT Acoustic Focusing Cytometer using a 561 nm laser and (A 61/2 or (B, C 61/15 emission filters. The conventional cytometer was run using the highest sensitivity setting (~12.5 μl/min. The Attune NxT cytometer was run at (B 12.5 μl/min, which is equivalent to the traditional flow cytometer and at (C 5 μl/min, which is 4x more sample. The Attune NxT cytometer showed equal or better results even at the highest flow rates. Figure 9. Minimal data variation at high sample rates with the Attune NxT Acoustic Focusing Cytometer. Jurkat cells were fixed and stained with propidium iodide, treated with RNase, and analyzed at a concentration of 1 x 1 6 cells/ml on the Attune NxT Acoustic Focusing Cytometer at different sample rates. The left peak in all graphs reflects cells in G /G 1 phase, while the right peak reflects cells in G 2 /M phase. Regardless of sample rate, the width of the G /G 1 and G 2 /M peaks and CV% remains consistent for the Attune NxT cytometer, even at the highest sample rate of 1, μl/min. Figure 1. The Attune NxT software interface.

Service and support The Attune NxT Acoustic Focusing Cytometer is backed by our worldwide technical support and service programs. We are focused on delivering personalized service from the time our sales representative walks through the door throughout the life of your Attune NxT instrument. The Attune NxT cytometer is fully supported for one year with our extensive service plan, which includes: Comprehensive training (2 users per instrument Application and assay support Worldwide technical service Preventive maintenance Ordering information Attune NxT Acoustic Focusing Cytometer Lasers Laser color Parameters Cat. No. 4 Blue, red, yellow, violet 16 A24858 Blue, violet, yellow 1 A24859 Blue, red, violet 1 A2486 2 Blue, yellow 9 A24861 2 Blue, violet 1 A24862 2 Blue, red 9 A2486 1 Blue 6 A24864 For more information, go to lifetechnologies.com/attune For Research Use Only. Not for use in diagnostic procedures. 215 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Cy is a trademark of GE Healthcare. CO12126 115