VORTISAND CROSS-FLOW MICROSAND FILTRATION SYSTEMS THE INDUSTRY LEADER IN HIGH EFFICIENCY SUBMICRON FILTRATION SYSTEMS

Similar documents
VAF FILTRATION SYSTEMS COOLING TOWER WATER FILTRATION SYSTEMS

HYDRO-CLEAR FILTERS: COUNT ON THEM 24/7/365 REACTION TANKS

YOUR DIRTY PROCESS WATER IS INCREASING YOUR TOTAL OPERATING COSTS

MEMCOR MEMBRANES FOR DRINKING WATER APPLICATIONS

ADI MEMBRANE BIOREACTOR (MBR) AEROBIC WASTEWATER TREATMENT SOLUTION

THE COMAG SYSTEM FOR ENHANCED PRIMARY AND TERTIARY TREATMENT

The Culligan Hi-Flo 50 Series Industrial Water Filter System

CHLOROPAC SYSTEMS FOR SEAWATER ELECTROCHLORINATION

Treatment or Process Filtration

REACTION TANKS ADVANCED MEMBRANE FILTRATION

REACTION TANKS BUILD OWN OPERATE WATER MANAGEMENT PROGRAM

Produced Water Treatment Systems

ADI ANAEROBIC MEMBRANE BIOREACTOR (AnMBR)

Akiki Engineering Est.

THE BIOMAG SYSTEM FOR ENHANCED SECONDARY TREATMENT

WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters

The Use of Walnut Shell Filtration with Enhanced Synthetic Media for the Reduction and/or Elimination of Upstream Produced Water Treatment Equipment

Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September Evoqua Water Technologies LLC

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration

FILTERS. specifically designed for Ballast Water Treatment TECHNICAL SPECIFICATIONS. Vol. 2

PURELAB CHORUS SYSTEMS

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

High Efficiency Liquid-Solid Separators

Produced Water Treatment Systems

PURELAB CHORUS SYSTEMS

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

3M Purification Inc. 3M High Flow Series Filter Systems

DEFENDER REGENERATIVE MEDIA FILTER REACTION TANKS

Astrasand Continuous Backwash Filter. Water Technologies

Omnipac Field-Erected SBR Package Plants. jet tech sbr technology

REACTION TANKS CENTRA CENTRALIZED LABORATORY WATER SYSTEMS

Municipal & Industrial. Filtration Solutions

rim-flo secondary Clarifier with Tow-Bro unitube sludge removal system

Pall Aria System Rescues Bottled Spring Water Producer from Plant Closure

THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS

TECHNOLOGIES THAT MAXIMIZE PROFITABILITY AND ENSURE COMPLIANCE

EVALUATION OF PILE CLOTH MEDIA FILTRATION OF SECONDARY EFFLUENT FOR WATER REUSE

AS-H Iso-Disc Cloth Media Filter

ReactoGard V. Your industry partner for refinery solutions in liquid filtration

Walnut Shell Filter Reuse Potential

We Know Water. Hydrotech Discfilter Pure Performance WATER TECHNOLOGIES

SeaCURE BALLAST WATER MANAGEMENT SYSTEMS COMPLIANCE ASSURED, WHEREVER YOU ARE.

Pora. A Host of Latest Water Membrane Technologies

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Please Contact us for a price on this Refurbished Ion Exchange Softener!

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

Industrial & Municipal Catalogue

Standard Water Treatment Equipment Solutions WATER TECHNOLOGIES

Leopold Desalination Pretreatment Systems

COMMERCIAL / INDUSTRIAL COOLING TOWER SIDE STREAM FILTER SYSTEMS

FLUIDPRO SERIES MEMBRANE AIR DRYERS WITH OPTIONAL PREFILTRATION AND OPTIONAL PURGE CONTROL ENGINEERED FILTRATION

OmniflO Sequencing batch reactor (SBR) jet tech sbr technology. Proven Performance Under Demanding Conditions

NEW LOGIC RESEARCH. Case Study

Advances in Media Filtration

Keeping the heat transfer surfaces of a cooling tower system clean is widely recognized as the best way to ensure efficient operation.

Discfilter. Filtration Made Simple

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

Heat Transfer Filtration

Proven Solutions for the Most Challenging Wastewaters

A reliable, scalable and proven way to treat ballast water

Compact design Smaller housing minimises capital expense requirements Reduces system footprint. Up to 50% smaller than competitively sized housing.

Advances in media filtration. Leveraging advanced filtration media with a high oil loading capacity to improve water treatment

Reclamation of Sand Filter Backwash Effluent using HYDRAcap LD Capillary UF Membrane Technology

Waste Water Treatment Equipment

Features Reliable, DOW FILMTEC Membrane 4 - Stage Reverse Osmosis System - Part Number:

Specifications 9-Inch 10-Inch

Energy and Water Savings

Filtration Systems TM. Wherever Water Flows...

Filtration Systems. Screen Filters 50, 100 & 20, 50, 100 & 125. Plastic Screen Filters. Metallic Screen Filters 150 X 125

Your Clear Choice for Filtration and Water &Wastewater Treatment equipment

HIGH RATE DAF DISSOLVED AIR FLOTATION

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

Beer Filtration Solutions Your Partner for All Your Filtration Needs

Heat Transfer Filtration

FILTER CLEAR VESSEL FCV

Project Name: Melut Basin Oil Development. Client Name: PDOC, Petrolium. Development Oman Company. EPC: Dodsal. Consultant: Mott MacDonald

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

BIOSPHERE MOVING BED BIOLOGICAL SYSTEMS

How Far Can You Push Your Filters? Optimization Lessons

Compact Waste Water Treatment MBR /MBBR Technology

VOLUME 06 ISSUE 07-JULY 2013

INNOVATIVE TECHNOLOGY TO IMPLEMENT A REUSE WATER PROGRAM. Stefan Haecker*, John Healy** 9311 College Parkway, Suite 1 Fort Myers Florida 33919

Filter Inspection and Optimization Case Studies

ChromaPur. Chromic Acid Purification System

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

EXECUTIVE SUMMARY AND TECHNICAL INFORMATION

ADVANCED FILTERS FOR BALLAST WATER TREATMENT

ADVANCED FILTRATION FOR WATER TREATMENT APPLICATIONS

Next Generation of Filtration Technology

Fine Screening System: The More Intelligent Primary Clarifier. Sandra Schuler Huber Technology, Inc. Team Leader Mechanical Treatment

Betapure CMP Series. CMP Filter Capsules. Superior Reduction Of Large Particle Counts For Improved Yields. Features & Benefits.

ACTIFLO Process. For Wet Weather and Wastewater Treatment WATER TECHNOLOGIES

Iron/Manganese Package Plant Pre-Engineered Ground Water Treatment. Village of Bolivar, NY

City of Woodbury. Red Bank Water Treatment Plant - Treatment Alternatives Analysis November 2016

POREX Tubular Membrane Filter (TMF ) Applied in Copper/Nickel Wastewater Treatment System for an Electroplating Industry Park

Xylem s fully integrated, ozone-enhanced biologically active filtration system for water reuse

The High-Capacity. Inclined Plate. Settler System

Lowering The Total Cost Of Operation

ACTIFLO Process. For Wet Weather and Wastewater Treatment WATER TECHNOLOGIES

Transcription:

VORTISAND CROSS-FLOW MICROSAND FILTRATION SYSTEMS THE INDUSTRY LEADER IN HIGH EFFICIENCY SUBMICRON FILTRATION SYSTEMS

MARKETS Cooling Towers Pre Membrane/RO Aquatics & Recreational Oil & Gas Water Reuse Wastewater Semiconductor & Electronics Drinking Water Food & Beverage Data Centers

ABOUT VORTISAND SYSTEMS Vortisand systems are synonymous with water filtration, serving the industrial water markets since 1986. The award-winning Vortisand is a High Efficiency Microsand Filtration System. It is a high capacity media filter that combines cross-flow dynamics with microsand media to achieve submicron filtration performance. This technology allows the unit to operate at filtration rates of up to 5 times greater than those of traditional media filters, while filtering 10-50 times finer. With over 2,500 installations worldwide, Vortisand has become a leader in high efficiency filtration systems. D1200 (Stacked & Skid Mounted) Classic S36 (Skid Mounted) 3 x D1200 (Stacked & Skid Mounted)

HOW IT WORKS Vortisand filtration systems use exclusive VortiJet TM diffusers to generate cross-flow patterns that sweep the surface of the media. This sweeping motion causes a portion of the water to flow parallel to the top media layer, allowing for high filtration rates while preventing fouling and channeling. Contaminants trapped in suspension and within the microsand media (depth filtration) are easily removed using an automatic backwash cycle. The system s backwash cycle requires less flow and a shorter duration than traditional sand or multi-media filters. The result is a technology that removes particles down to submicron levels at 4 to 5 times the hydraulic flow rate of other media filters, while requiring up to 50% less water for backwash.

TECHNOLOGY BENEFITS HIGH EFFICIENCY SUBMICRON FILTRATION The system s high efficiency lies in the unique use of microsand and cross-flow filtration. Vortisand systems can capture particles under 1 micron in size, 10 to 50 times smaller than particles retained by other media filters. How Small is a Micron? HIGHER FLOW The cross-flow technology has allowed us to optimize the media bed depth and improve filtration capacity. By doing so, we were able to design a horizontal vessel that provides the ultimate in filter technology. With a single 36-inch vessel the horizontal design is capable of treating a flow of up to 1,200 gpm, offering unparalleled performance and value. The speed is up to 5 times faster than traditional filters at 25 gpm/ft2 (60 m/h), while delivering higher water quality than traditional media filters. AUTOMATED OPERATION Vortisand systems provide a fully automated experience, along with maintenance reminders and a user friendly interface to make operating and maintaining the system an easy task. LOWER COST OF OPERATION An important consideration for any filtration system is the overall operating cost. The Vortisand filtration systems help reduce operating costs in several ways: Reduced Water Consumption: Requires up to 50% less water during backwash when compared to traditional multi-media (MM) filtration systems. Energy Savings: Significant energy savings is achieved in heat transfer applications by helping prevent the formation of sediment and bio-film, leading to greater heat-exchanger efficiency. Reduced Chemical Costs: Significantly improve the effectiveness of chemical treatment by reducing the total suspended solids (TSS). Low Maintenance Costs: Requires little to no human intervention, with minimal maintenance tasks. With an array of design, instrumentation and control options, our team of engineers will develop a solution that will meet today s goals and tomorrow s challenges. SMALLER FOOTPRINT The effective use of the media bed ultimately results in requiring less media, allowing our customers to achieve high levels of efficiency with a smaller footprint (up to 80% smaller and lighter than traditional filters). The system can be customized to offer a vertically stacked design capable of doubling the filtration capacity within the same footprint. This unique lightweight and compact design provides both shipping and on-site infrastructure savings. Vortisand H2F Series Stacked

SPECIFICATIONS VORTISAND H2F SERIES The Vortisand H2F horizontal series is designed for higher flow applications. With its stackable capabilities the H2F series is available in a variety of sizes and configurations, engineered to suit nearly any application. Model Number Max Filtration Capacity @ 25 gpm/sf Shipping (Skid) Dimensions Pump Feed Inlet/ Outlet Diam. Backwash Inlet/Outlet gpm m3/h (w x l x h) hp/kw in/mm in/mm S300 350 80 4.5 x 8 x 6 (1.4m x 2.4m x 1.9m) 10/7.5 4 /100 3 /80 D300 700 160 4.5 x 9.6 x 8.4 (1.4m x 2.9m x 2.6m) 15/11.2 6 /150 3 /80 S600 600 136 6.3 x 10.2 x 6 (1.9m x 3.1m x 2m) 15/11.2 6 /150 4 /100 D600 1200 272 6.3 x 10.4 x 8.4 (1.9m x 3.2m x 2.6m) 20/14.9 8 /200 4 /100 S1200 1090 248 7.7 x 19 x 6 (2.4m x 5.8m x 1.9m) 20/14.9 8 /200 6 /150 D1200 2180 495 7.7 x 20.4 x 8.4 (2.4m x 6.2m x 2.6m) 40/29.8 10 /250 6 /150 VORTISAND CLASSIC SERIES The Vortisand classic series is designed for lower flow applications. The classic vertical series is available in a variety of sizes and engineered to suit nearly any application. Model Number Max Filtration Capacity @ 20 gpm/sf Shipping (Skid) Dimensions Pump Feed Inlet/ Outlet Diam. Backwash Inlet/Outlet gpm m3/h (w x l x h) hp/kw in/mm in/mm S12 16 3.6 32 x 38 x 66 (.81m x.97m x 1.7m) 0.5/0.4 1 /25.4 1 /25.4 S20 44 10 39 x 44 x 73 (.99m x 1.1m x 1.9m) 1.5/1.1 1.5 /38 1.5 /38 S24 65 15 43 x 48 x 74 (1.1m x 1.2m x 1.9m) 1.5/1.1 2 /51 1.5 /38 S30 100 23 46 x 51 x 78 (1.2m x 1.3m x 2m) 2/1.5 2 /51 2 /50 S36 140 32 53 x 63 x 80 (1.3m x 1.6m x 2m) 3/2.2 3 /76 2 /50

LARGE OR SMALL, THERE S A VORTISAND SYSTEM FOR YOU.

3584 Boulevard Poirier, Montreal, Quebec, H4R 2J5, Canada +1 (888) 876-9655 (toll-free) +1 (514) 335-2200 (toll) www.vortisand.com www.evoqua.com Vortisand and vortisand H2F are trademarks of Evoqua, its subsidaries and affiliates in some countries. All other trademarks are those of their respective owners. All information presented herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as to the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications. Evoqua assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse of its products. 2016 Evoqua Water Technologies LLC Subject to change without notice VS-VORTISAND-BR-1116