COMPRESSED AIR FILTERS HF SERIES

Similar documents
20 21,250 SCFM GLOBAL AIR TREATMENT. CFL Series

CFF Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC

World Class Filtration

CAF Series Compressed Air Filters 20 21,250 CFM

industry revolves around VAF Series Compressed Air Filters CFM

Engineering Excellence

Compressed Air Filters. Particulate, Liquid, and Oil Removal ,250 scfm. kaeser.com

Energy Saving Compressed Air Filters. NGF SERIES 20 to 1500 scfm (34 to 2459 nm 3 /h)

Compressed Air Filters. Particulate, Liquid, and Oil Removal ,875 scfm. kaeser.com

Compressed Air Filters. Particulate, Moisture, and Oil Removal scfm.

Features and Benefits

Del-Monox Breathing Air Purifiers DM Series

Filters & Elements. People. Passion. Performance

Filters & Elements. People. Passion. Performance

Line filters LINE FILTERS

Energy Saving Compressed Air Filters. NGF SERIES 20 to 1500 scfm (34 to 2459 nm 3 /h)

Compressed Air Systems. Compressed Air Filters. Balston Microfiber Filter Assemblies. Product Features

Atlas Copco Quality Air Solutions. Compressed Air Filters

Atlas Copco. Quality Air Solutions Compressed Air Filters

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

Line filters LINE FILTERS

Del-Monox Breathing Air Purifiers

Breathing Air Purifiers BAP SERIES

Table of Contents. Delta Series

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

ASME Code Filter Vessels Compressed Air & Gas Filtration

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

ULTRA-FILTER COMPRESSED AIR FILTERS DF SERIES. Compressed Air & Process Filtration

HIGH EFFICIENCY FILTERS FOR COMPRESSED AIR PURIFICATION. Filtration & System solutions. AIR VIP EvO

F-Series 1 Elements Performance Validation

CONTINUOUS FLOW BREATHING AIR PURIFIERS

Compressed Air Filtration

Compressed Air Filters Sample Filters

Filtration and Air Drying Products. Balston Product Catalog. Bulletin FNS-G

TF Threaded filters

2 Through 10 Line Size Filters Model AKC-0280 Model AKC-0880 Balston Natural Gas Filters Balston Compressed Gas Filters Balston high flow rate compres

Compressed Air Filtration. Filters Coalescers Absorbers Elements Mist Eliminators

Compressed Air Filters AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. JLA, JT & JW Series

PRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES

North American Filter Corporation

Compressed Air Filters 1/4 and 1/2 Line Size Filters

HAFFMANS CPM COALESCENCE & ACTIVATED CARBON FILTERS FOOD & BEVERAGE FILTRATION

The most energy efficient compressed air filters in the world.

High Pressure Compressed Air and Gas Filters

FLUIDPRO SERIES MEMBRANE AIR DRYERS WITH OPTIONAL PREFILTRATION AND OPTIONAL PURGE CONTROL ENGINEERED FILTRATION

Finite. ASME Coded Vessels Compressed Air & Gas Filters. Bulletin /USA. Coalescing, Bulk Liquid Removal, Particulate & Hydrocarbon Adsorption

P-SRF V STERILE AIR PLEATED DEPTH FILTER ELEMENTS. Process Filtration

COALESCING FILTERS. UD+ Series ( l/s / cfm) Nautilus filter technology

Table of Contents. International H-Series. ASME Coded Vessels. Pages Micro-Series. Dual Stage BA-Series. High Pressure Filters.

Ingersoll Rand. You, Your Company and Our Environment

Continuous Flow Breathing Air Purifiers CATALITE CBA SERIES

STEAM, STERILE AIR AND LIQUID FILTRATION. Process Filtration

ASME Code Filter Vessels

COMPRESSED AIR SYSTEM DESIGNS BEGIN WITH THE DEMANDS

Relays & Volume Boosters

OIL-X EVOLUTION. High Efficiency Compressed Air Filters ENGINEERING YOUR SUCCESS.

Seven Stage Color Guard Depth Filtration

FILTRATION SYSTEMS Jordair QC Program Filter Design Features: Cartridge Features:

Continuous Flow Breathing Air Purifiers

ENVIROAIRE VS15 VS HP OIL-LESS SINGLE-STAGE VARIABLE SPEED ROTARY SCREW COMPRESSOR. EnviroAire VS Series

FILTRATION for CNG. Compressed Natural Gas (CNG) Filters. Dryers Compressors Storage Cascades Dispensers.

Air Compressor Series.

LIQUID LINE FILTER DRIER DCH SERIES (SOLID CORE TYPE)

Introduction. Keith Atkinson Global Product Manager Downstream Equipment & Nitrogen Systems. Gardner Denver Industrials Group

MATERIALS OF CONSTRUCTION

Vacuum Dehydration Oil Purification System (VDOPS)

Oil-Free Rotary Screw Air Compressors kw Horsepower

0.01 Micron Membrane Filters

PRESSURE SWING ADSORPTION NITROGEN GENERATION SYSTEM. GDN2 Series

OIL PURIFICATION SYSTEM

G E N E R A L C AT A L O G

NITROGEN SERIES COMPRESSOR SYSTEMS

Air Filtration. Innovation Reliability Efficiency

High Pressure Filter Assemblies

parker domnick hunter oil-x evolution

Continuous Flow Breathing Air Purifiers CATALITE CBA SERIES

1,500 PSIG STAINLESS STEEL HOUSINGS

Process Inline Filter, Change-Over

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

Particulate Filters. Filter Function. Exclusive Dense Pack Element Design. Optional Components

PERTH SYDNEY MELBOURNE BRISBANE ADELAIDE NEWCASTLE DARWIN MACKAY KALGOORLIE

UFR+L FILTER REGULATOR + LUBRICATOR

STERILE AIR. Process Filtration

NATURAL GAS FILTRATION High efficiency filters and separators for removing solid particles, water, aerosol and oil vapour from compressed Natural gas

Fiberglass Cooling Towers

Equipment. Description. Features. Ordering Information. indicating oxygen trap Series 6200

Energy Saving Refrigerated Air Dryer. HES SERIES 3750 to scfm (6371 to nm 3 /h)

NITROGEN SERIES COMPRESSOR SYSTEMS

Specifications. 304 Stainless Steel Mesh Screen. Specifications

Filtmaster filtration

REVERSE OSMOSIS WATER TREATMENT

Products for Industrial Filtration

ISO/TC 131/SC Pneumatic fluid power Compressed-air filters

* Approximate flow at 90 psig (6.3 bar) inlet pressure and 5 psig (0.35 bar) pressure drop. F07 FLOW CHARACTERISTICS

Process Filtration From Pure to Sterile

Ingersoll Rand. Air Filtration

Lubricated Rotary Screw Air Compressors. Constant Speed Drives and Variable Speed Drives kw hp

Maximum performance. Contaminant Removal Efficiency 99.97% Baldwin RS % Contaminant Holding Capacity. 3362g. 3365g

WARRENDER, LTD. Services. Ammonia & CO² Circulation and Transfer Pumps

Transcription:

COMPRESSED AIR FILTERS HF SERIES

COMPRESSED AIR TREATMENT REDUCES OPERATING COSTS Cut the Cost of Compressed Air. Hankison filters remove more contaminants with less pressure drop. Compare the operating pressure drop of competitive brands and remember that for every extra psi of pressure drop, power input needs to be increased by %. FROM THE LEADER IN COMPRESSED AIR TREATMENT Since Hankison first developed their coalescing filters in the 970s, they have been a leader in filtration design. HF Series filters are the result of extensive testing of the latest state-of-the-art materials in filtration media. Filter elements have been designed utilizing the latest media innovations and manufacturing techniques. The result is increased performance, reduced size and lower operating pressure drop, in a variety of grades to match your requirements. Housings have large flow areas to reduce pressure drop and to allow easier installation, operation and maintenance. A systems approach has been used to allow for convenient matching of filter types to achieve the air quality you desire, while comprehensive third party testing guarantees performance to CAGI, ISO and PNEUROP standards. With a greater selection of filter grades, more models to choose from and worldwide technical and service support, Hankison offers a systemized solution for your compressed air quality needs. LET HANKISON GIVE YOU THE COMPRESSED AIR QUALITY YOU REQUIRE A typical compressed air system is contaminated with...abrasive solid particles such as dust, dirt, rust and scale...compressor lubricants (mineral or synthetic)...condensed water droplets and acidic condensates...and oil and hydrocarbon vapors. If not removed, these contaminants increase pneumatic equipment maintenance costs, lead to instrument and control failure, contribute to poor product fit and finish, and contaminate processes. The right Hankison filter or filter system will remove these contaminants allowing your compressed air system to deliver the quality of air required by your application...whether it s plant air, instrument air or medical air...helping to ensure consistent output quality while minimizing operating costs. CAGI - Compressed Air And Gas Institute ISO - International Standards Organization PNEUROP - European Committee of Manufacturers of Compressors, Vacuum Pumps and Pneumatic Tools

HF SERIES COMPRESSED AIR FILTERS MODULAR HOUSINGS FOR FLOWS THROUGH 780 SCFM Enlarged flow paths reduce pressure drop Manufactured from top quality aluminum, zinc and steel Chromated and epoxy powder painted (interior and exterior) for added durability and corrosion resistance 00 psig ( kgf/cm ) maximum working pressure (tested to a : safety factor) EASY TO OPERATE New differential pressure indicators Indicates optimum time for element change maximizing your element investment while minimizing pressure drop. Slide indicator Economical changes color when filter element requires replacement. Gauge Large easy to read gauge face Dual gauge faces allow housings to be mounted in any flow direction Can be mounted remotely Switch for remote indication available EASY TO INSTALL Modular connections - allow housings to be connected in series easily, while saving space Wall mounting bracket optional Can be mounted for left or right entry New space saving design reduces service clearances EASY TO MAINTAIN 8 turn, self locking bayonet head to bowl connections (through ) Push on elements make element replacement quick and easy If housing is not depressurized before disassembly, escaping air gives audible warning Captive o-ring Ribbed bowls allow use of C spanner Color coded elements for easy identification Gauge Liquid level indicator Allows visual monitoring of liquid level and signals the need for preventative maintenance to avoid downstream contamination Manufactured from thermoset polyurethane, compatible with synthetic lubricants Bayonet Head Internal automatic drains Pilot operated, pneumatically actuated...reliably discharges collected liquids Viton seals...totally compatible with synthetic lubricants Inlet screen for additional protection Discharge fitting threaded to facilitate drain line connection Liquid Level Indicator Internal Automatic Drain

HANKISON ELEMENTS OFFER ENHANCED PERFORMANCE AND LOW PRESSURE DROP A CHOICE OF SEVEN ELEMENT GRADES ALLOWS YOU TO DESIGN A SYSTEM THAT DELIVERS THE AIR QUALITY YOU REQUIRE Push-on elements make element replacement easy Piston type element to housing seal keeps unfiltered air from by-passing element Corrosion resistant cores - Stainless steel for added structural integrity - Low resistance to flow - Seam welded for extra strength New matrix blended fiber media - Large, effective surface area - improves capture rate - ensures high efficiencies - Large open area minimizes pressure drop Coated, closed cell foam sleeve - Resists chemical attack from oils and acids - Ensures high efficiencies by preventing reentrainment of coalesced liquids Chemically resistant end caps bound to media with specially formulated adhesive Silicone free Withstands temperatures to 0 F (66 C) Grade Grade 7 MOISTURE SEPARATOR bulk liquid removal. Maximum inlet liquid Load: 0,000 ppm w/w Filtration Two stainless steel orifice tubes provide 0 micron mechanical separation GENERAL PURPOSE AIR LINE FILTER for removal of liquid water and oil; removes solid particles to micron (.0 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores First stage - captures larger particles with alternate layers of fiber media and media screen Second stage - coalesces aerosols and captures solid particles with multiple layers of epoxy bonded, blended fiber media Air Quality/Pressure Drop Solid Pressure Drop at Rated Particles Remaining Conditions Down to Oil Content psid [kgf/cm ] Grade micron ppm by weight Dry Wet 0-0.8 [0.06] 0.8 [0.06] 9 [0.07]. [0.] 7 [0.07] [0.4] 6 - [0.07] - 0.0 0.008 [0.07] [0.] 0.0 0.0008 [0.07] 6 [0.4] 0.0 0.00 [0.07] NA Grade 9 SEPARATOR/FILTER mechanical for bulk liquid removal plus a micron coalescer ( ppm w/w maximum remaining oil content) First stage - two stainless steel orifice tubes provide 0 micron mechanical separation Second stage - in-depth fiber media captures solid and liquid particles to microns 4

HF SERIES COMPRESSED AIR FILTERS Grade 6 Second stage - captures larger particles with alternate layers of fiber media and media screen Grade DRY PARTICULATE AIR LINE FILTER for removal of solid particles to micron First stage - coalesces aerosols and captures solid particles with multiple layers of epoxy bonded, blended fiber media HIGH EFFICIENCY OIL REMOVAL FILTER for coalescing fine water and oil aerosols; removes solid particles to 0.0 micron (0.008 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores First stage - multiple layers of fiber media and media screen remove larger particles, prefiltering the air for the second stage Second stage - multiple layers of bonded, blended fiber media for fine coalescence Outer coated, closed cell foam sleeve Grade outer cores First stage - coated, closed cell foam sleeve acts as prefilter and flow disperser Second stage - multiple layers of matrix blended fiber media for ultra-fine coalescence Outer coated, closed cell foam sleeve Grade ULTRA HIGH EFFICIENCY OIL REMOVAL FILTER for coalescing ultra-fine oil aerosols; removes solid particles to 0.0 micron (0.0008 ppm w/w maximum remaining oil content) Corrosion resistant inner and OIL VAPOR REMOVAL FILTER for removal of oil and hydrocarbon vapors normally adsorbable by activated carbon; removes solid particles to 0.0 micron (0.00 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores First stage - a stabilized bed of finely divided carbon particles removes the majority of the oil vapor Second stage - multiple layers of fiber media with bonded microfine carbon particles remove the remaining oil vapor Multiple layers of fine media prevent particle migration Outer coated, closed cell foam sleeve prevents fiber migration Designed for 000 hour life at rated conditions Filter efficiency has been established in accordance with CAGI standard ADF400 and is based on 00ºF (8ºC) inlet temperature. Filter efficiency has been established in accordance with CAGI standard ADF00 and is based on 00ºF (8ºC) inlet temperature.

06_04_SPX_Hank_HFFilters:HPRp-HES_Brochure /9/006 8:4 AM Page 6 APPLICATION GUIDE, PRODUCT FEATURES AND SPECIFICATIONS APPLICATION GUIDE Element Type Grade Description Bulk Liquid Separator Bulk Liquid CAGI, ISO, and PNEUROP Performance Data Maximum inlet liquid load: 0,000 ppm w/w Water Separator Element Grade 9 Mechanical separator and micron coalescer removes Liquid Large particles Solids and liquids microns and larger Remaining oil content ppm w/w ISO 87. Quality Class - Solids: Class, Oil Content: Class Maximum inlet liquid load:,000 ppm w/w Separator / Element Where Used Liquids and Solids 0 microns and larger Downstream of aftercoolers At point-of-use if no aftercooler/separator used upstream 9 7 Grade 7 Air Line Element Grade 6 General Purpose micron coalescer for shop air operating Tools Motors Cylinders Solids and liquids micron and larger Remaining oil content ppm w/w Upstream of ultra high efficiency oil removal filters ISO 87. Quality Class - Solids: Class, Oil Content: Class 4 Maximum inlet liquid load:,000 ppm w/w At point-of-use if aftercooler/ separator installed upstream Dry Solids Removal Pipeline protection from abrasive desiccant dust Solids microns and larger No liquid should be present at filter inlet 7 6 Downstream of pressure-swing (heatless) desiccant dryers Dry Particulate Element Grade High Efficiency Oil Removal Element Grade Ultra High Efficiency Oil Removal Element Grade Oil Vapor Removal Element Filter Type HTA Series Fine coalescer for oil free air for industrial use Painting Injection molding Instruments Control valves Solids and liquids 0.0 micron and larger 99.99+% of oil aerosols; remaining oil content 0.008 ppm w/w ISO 87. Quality Class - Solids: Class, Oil Content: Class Maximum inlet liquid load:,000 ppm w/w 6 ISO 87. Quality Class Solids: Class, Oil Content: Class Maximum inlet liquid load:,000 ppm w/w Ultra fine coalescer for oil free air for critical applications Where air contacts product Conveying Agitating Electronics manufacturing Nitrogen replacement Solids and liquids 0.0 micron and larger 99.999+% of oil aerosols; remaining oil content 0.0008 ppm w/w Activated carbon filter for odor free air for Food and drug manufacturing Breathing air Gas processing Oil vapor: remaining oil content 0.00 ppm w/w (as a vapor) Solids 0.0 micron and larger Description High Temperature Dry Particulate Afterfilter ISO 87. Quality Class - Solids: Class, Oil Content: Class Maximum inlet liquid load: 00 ppm w/w ISO 87. Quality Class - Solids: Class, Oil Content: Class Upstream of desiccant or membrane dryers; use a Grade 7 as a prefilter if heavy liquid loads are present 7 Downstream of refrigerated dryers Downstream of high efficiency oil removal filters 0R No liquid should be present at filter inlet - use a high efficiency oil removal filter upstream of Grade filters to prevent liquid oil contamination CAGI, ISO, and PNEUROP Performance Data Where Used Solids micron and larger No liquid should be present at filter inlet High Temperature Dry Particulate Solids and liquids 0.008 micron and larger 99.99+% of oil aerosols; remaining oil content 0.0 ppm w/w HTA Downstream of heat reactivated desiccant dryers

HF SERIES COMPRESSED AIR FILTERS HTA SERIES PRODUCT SPECIFICATIONS Dimensions Model Number Max. Flow @ 00 psig MWP @ 40 F Connections H W Weight scfm psig in. mm in. mm lbs. kg HTA00 00 0 NPT 4. 64 4. 08.9 HTA00 00 0 NPT.8 60 4. 08 9 8.6 HTA400 400 6 NPT 9.6 00 0. 60 9 4 HTA600 600 6 NPT 9.6 00 0. 60 9 4 HTA00,00 6 NPT 4.44 0 6.00 406 9 7 HTA800,800 6 NPT 4. 099 6. 4 9 99 HTA400,400 6 4 ANSI Flange 4.69 89 0.00 08 6 07 HTA000,000 6 4 ANSI Flange 4.69 89 0.00 08 9 08 HTA4800 4,800 6 6 ANSI Flange.00 46 4.00 60 9 4 HTA6600 6,600 6 6 ANSI Flange 6.00 7 8.00 7 48 49 HTA8400 8,400 6 6 ANSI Flange 6.00 7 8.00 7 48 49 HTA400,400 6 8 ANSI Flange 68.9 7.00 88 77 0 Pressure drop: At rated flow conditions pressure drop will be less than psid (0.07 kgf/cm ). Pressure drop will increase only as the filter cartridges become loaded with solid particles. Filter cartridge replacement: Filter cartridges should be replaced annually or, when pressure drop across the cartridge exceeds acceptable differential pressure. Maximum temperature: 40 F ( C) Units with higher MWP are available; contact factory. Model HTA00 and larger are ASME code constructed and stamped. BSP connections and DIN Flanges are available. HF SERIES PRODUCT SPECIFICATIONS Max. Flow Standard Features Max. Pressure & Temp. Dimensions Replacement Model Number @ 00 psig Connections Filter Grades Manual With H W Weight Element scfm NPT / ANSI Flg. 9 7,, 6 Drain D in mm in mm lb kg Model Qty. Modular Type Housings HF(Grade)--(Conn.)-(Features) 0 D D 8. 07 4. 0 4..9 E (Grade)- - /8" NPTF or D HF(Grade)-6-(Conn.)-(Features) P P P.0 8 4. 0 8..7 E (Grade)-6 4 - /" NPTF P HF(Grade)-0-(Conn.)-(Features) 60 L L.40 40 4. 0 8..9 E (Grade)-0 HF(Grade)-4-(Conn.)-(Features) 00 6 - /4" NPTF or D. 89. 6..9 E (Grade)-4 D HF(Grade)-8-(Conn.)-(Features) 70 8 - " NPTF G, L 00 psig 0 psig D 9.7 497. 6.9. E (Grade)-8 kgf/cm 7.6 kgf/cm HF(Grade)--(Conn.)-(Features) 0 G 8 - " NPTF or G N/A.80 79 6.44 64 0. 4.6 E (Grade)- HF(Grade)-6-(Conn.)-(Features) 7 () 0 - -/4" NPTF or L L 0 F 0 F - - /" NPTF G 66 C 66 C 7.9 69 6.44 64.. E (Grade)-6 HF(Grade)-40-(Conn.)-(Features) 48 0 - -/" NPTF G D 6 - " NPTF or.08 789 7.6 94 8.7 E (Grade)-40 HF(Grade)-44-(Conn.)-(Features) 6 G 6.8 9 7.6 94.0 E (Grade)-44 0 - /" NPTF HF(Grade)-48-(Conn.)-(Features) 780 4.96 09 7.6 94 8 7. E (Grade)-48 ASME Pressure Vessels HF(Grade)--(Conn.)-(Features) 6 D, G D, G 00 psig 00 psig 40.88 08 0. 60 6 6. E (Grade)-PV 4 - " NPTM HF(Grade)-4-(Conn.)-(Features),000 48.00 9 6.00 406 9 4. E (Grade)-4 80 - DN 80 Flange HF(Grade)-6-(Conn.)-(Features),0 48.00 9 6.00 406 9 4. E (Grade)-PV HF(Grade)-60-(Conn.)-(Features),87 4 - " NPTM 49.00 4 6. 4 0 4.4 E (Grade)-PV HF(Grade)-64-(Conn.)-(Features),00 psig psig. 7 0.00 08 79 8. E (Grade)-PV 4 4F - 4" ANSI Flange HF(Grade)-68-(Conn.)-(Features), N/A.8kgf/cm G G G.8 kgf/cm. 7 0.00 08 8 8.6 E (Grade)-PV HF(Grade)-7-(Conn.)-(Features),000 6F - 6" ANSI Flange 4.6 87 4.00 60 7 E (Grade)-PV 8 HF(Grade)-76-(Conn.)-(Features) 6,87 0 F 0 F 6.6 89 8.00 7 8 E (Grade)-PV 6F - 6" ANSI Flange HF(Grade)-80-(Conn.)-(Features) 8,70 66 C 66 C 6.6 89 8.00 7 7 9 E (Grade)-PV 4 HF(Grade)-84-(Conn.)-(Features),87 8F - 8" ANSI Flange 69. 76.00 88 709 E (Grade)-PV 9 HF(Grade)-88-(Conn.)-(Features) 6,0 8F - 8" ANSI Flange 67.94 76 9.00 99 98 46 E (Grade)-PV 6 HF(Grade)-9-(Conn.)-(Features),0 0F - 0" ANSI Flange 70.94 80 4.88 6 4 640 E (Grade)-PV 4 Filter Grades - Mechanical Separator (bulk liquid) 9 - Separator/Filter ( micron and bulk liquid) 7 - Air Line Filter ( micron) 6 - Dry Desiccant Afterfilter ( micron) - High Efficiency Oil Removal Filter (0.008 ppm) - Maximum Efficiency Oil Removal Filter (0.0008 ppm) - Oil Vapor Removal Filter (activated carbon) Features: D - Internal Automatic Drain Mechanism G - Differential Pressure Gauge Indicator L - Liquid Level Indicator M - Filter Monitor P - Differential Pressure Slide Indicator S - Corrosion Proof Stainless Steel Cores X - External Drain Adapter CAPACITY CORRECTION FACTORS Drain plugs standard. Externally mounted automatic drains are available. () Time-based Filter Monitor recommended. To find the maximum flow at pressures other than 00 psig (7 kgf/cm ), multiply the Max. Flow (from tables below) by the Correction Factor corresponding to the minimum pressure at the inlet of the filter. --Do not select filters by pipe size; use flow rate and operating pressure. Table - Correction Factors (multipliers) for Inlet Pressure psig 0 0 40 60 80 00 0 0 00 0 00 Minimum Inlet Pressure kgf/cm.4..8 4..6 7.0 8.4 0.6 4. 7.6. Correction Factor 0.0 0.9 0.48 0.6 0.8.00.7.4.87..74 7

FILTER MONITOR SERIOUS SAVINGS WITH FILTER MONITOR Titans of industry know how costly compressed air generation can be. Companies that are serious about reducing costs generally consult professional compressed air system auditors to analyze their air generation systems and plant air demands so they can strategize on areas to eliminate waste and improve efficiencies. It is no wonder that many filters are ordered and installed with an optional Filter Monitor. TAKE CONTROL Annual Energy Saving Potential Flow System Pressure Reductions SCFM psig 4 psig 6 psig 8 psig 0 psig 00 $ 4.77 $ 87.4 $ 4. $ 7.08 $ 78.8 0 9.4 78.8,078.7,47.69,797. 00 78.8,47.69,6.4,87.8,94.,000,47.69,87.8 4,.07,70.76 7,88.46,000,87.8,70.76 8,66.,0. 4,76.9,000 7,88.46 4,76.9,6.7 8,7.8,94.8 0,000 4,76.9 8,7.8 4,0.74 7,07.6 7,884.6 * Assumes scfm/hp, $0.0 per kwh, 8,760 hours of operation per year Filter Monitor's accuracy lets you manage element condition to reduce costly system pressure. Example: 00 scfm air system - change filter element at psig vs. 0 psig to add $,87.8 to your bottom line. Filter Monitor uses advanced microprocessor technology to help you take control with complementary modes of operation as standard. Time Monitoring Mode provides notification when it is time to change the filter element per your selection from - months. Differential Pressure Mode - select the exact pressure differential you will tolerate to initiate the warning to minimize the cost of pressure drop. Filter Performance Mode Filter Monitor automatically analyzes your systems flow dynamics,800 times per hour to chart its unique operating characteristics. It references the parameters you selected and continually plots your system s profile to forecast the days left until it will cost more to operate the dirty element than to replace it. A warning is triggered 60 days before change-out is recommended and the days countdown until the filter element is changed. ISO 87. QUALITY CLASSES Solid Particles Humidity and Liquid Water Oil Class Particle Size, d (micron) Total concentration, Pressure Dew Point 0.0 < d O 0. 0. < d O.0.0 < d O.0 Aerosol, Liquid and Vapor Maximum Number of Particles per m C F mg / m ppm w/w 0 As Specified As Specified As Specified 00 0 O -70 O -94 O 0.0 O 0.008 00,000,000 0 O -40 O -40 O 0. O 0.08 Not Specified 0,000 00 O -0 O -4 O O 0.8 4 Not Specified Not Specified,000 O + O +8 O O 4 Not Specified Not Specified 0,000 O +7 O +4 6 O +0 O +0 Liquid Water Content, Cw g/m 7 C w O 0. 8 0. < C w O 9 < Cw O 0 Per ISO87-: 00(E) Improvements and research are continuous at SPX Hankison Specifications may change without notice. 006 SPX Dehydration & Process Filtration. All rights reserved. Inv# DBR-00-NA-7