RESEARCH HIGHLIGHT. Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings

Similar documents
RESEARCH HIGHLIGHT. Design and Construction of the Northern Sustainable House Arviat, Nunavut

EVALUATING THE ENERGY SAVINGS OF HIGH PERFORMANCE BUILDING ENCLOSRE RETROFITS Brittany Hanam, MASc, P.Eng. Graham Finch, MASc, P.Eng.

THE IMPORTANCE OF BALCONY AND SLAB EDGE THERMAL BRIDGES IN CONCRETE CONSTRUCTION

ACHIEVING HIGH-PERFORMANCE MULTI-UNIT RESIDENTIAL BUILDINGS: THE OPPORTUNITIES

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

The Importance of Slab Edge & Balcony Thermal Bridges

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Benny Farm Redevelopment, Montréal

airflow in to, out of, and within buildings. These airflows are resisted by the airtightness of building elements including the exterior enclosure and

Adaption of the passive house concept in northern Sweden - a case study of performance

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec Existing external wall construction

Thermal Bridging and Whole Building Energy Performance

Thermal Performance of Northern Facades ISO Clip System Summary

Welcome to this continuing education seminar. This is the first of two parts of the High- Performance Building series.

2010 National Building Code Adoption and Associated Process Changes

Thermal Bridging in Building Thermal Envelope Assemblies: Repetitive Metal Penetrations

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target.

APPENDIX 3C DOMINION HOTEL SPECIFICATIONS

Impact of Insulated Concrete Curb on Concrete Balcony Slab

THERMAL BRIDGING OF MASONRY VENEER CLADDINGS & ENERGY CODE COMPLIANCE

RESEARCH HIGHLIGHT. Documentation of Super-Insulated Housing in Yukon

Passive House Solutions Guide

What is NUFORM HOUSE KIT?

The Importance of Slab Edge & Balcony Thermal Bridges

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

Building Envelope

Built for sustainability Built for the environment Built for fuel efficiency Built for life

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec

Energy consumption and thermal comfort in a passive house built in Romania

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

FERO RAP TIE AND FAST SYSTEM THERMAL ANALYSIS

Airport Vicinity Acoustic Insulation

Project Description. Projected build start date 01 May 2010 Projected date of occupation 01 Nov Belfast, County Antrim, Northern Ireland

Testing different approaches to energy reduction in five 1½-storey post-war houses. n Roof constructed of 2 x 6 roof rafters and 1 x 8 roof

Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series.

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

14.8 kwh/(m²a) Project Documentation. 1 Abstract. R-951 Residence: Three Family Passive House Building. 1.1 Data of building. Year of construction

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

Iconography. KAPSARC Mosque

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

Exterior Perspective, East End

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

Supplementary Standard SB-12. Energy Efficiency For Housing

Thermal Analysis of CL-TALON Cladding Support System

EXTERIOR WALLS. exterior wall systems, cladding w/ masonry. chapters SUBJECT

2001 Building Failures Study

Passive Design Solutions. Passive House The Road to Net-Zero

2014 British Columbia Building Code Changes

Supplementary Standard SB-12. Energy Efficiency For Housing

Homesol Passive House Design Process

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

BUILDING ENCLOSURE DESIGN GUIDE WOOD FRAME MULTI-UNIT RESIDENTIAL BUILDINGS. Summary. 1. Introduction

Achieving the nearly zero energy building concept - A study based on practical experience

APPENDIX 3E HAZELWOOD HOTEL SPECIFICATIONS

36 BTrd / DP Architects ArchDaily

City of Vancouver Land Use and Development Policies and Guidelines

Thermal Bridging and Energy Standards 2014 BOABC Education Conference. November 27, 2014

Project Description. Projected build start date 11 Feb 2013 Projected date of occupation 14 Nov

Armatherm Structural Thermal Bridging Solutions

Case Study #9 Phoenix Rising

Built examples and project certification. Zeno Bastian, Passive House Institute

Project name SOLAR HOUSE 80/50 Project summary

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Project Description. Projected build start date Projected date of occupation. Dungannon, County Tyrone, Northern Ireland

Thermal Control in Buildings by John Straube (updated )

Project Description. Projected build start date Projected date of occupation 01 Jun Low Energy Buildings

Deep Energy Retrofit of a HighRise MURB

The Homeowner s Building Application Checklist for Constructing a Residential Addition

Can you Believe Energy Savings Forecasts

Energy Efficiency Requirements 9.36

SIP Homes: Built for a Lifetime of Comfort and Value

Energy Step Code requirements for Part 9 buildings. City of Richmond June 29, 2017

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Project Description. Projected build start date 03 May 2010 Projected date of occupation 06 Aug

2006 Building Science Press All rights of reproduction in any form reserved.

5 social row houses (Wachtebeke)

The Thermal Performance of the Nexcem Wall Form System.

Optimizing Energy Efficiency During Integrated Design: A Whitehorse Case Study

Mark Lawton, P.Eng., FEC. Airtightness in Buildings A Canadian History June 2017

Colorado Mountain College: Sustainable Design Standards

Chapter 7. Passive Solar Contents

A New Paradigm for the Design of Sustainable Buildings

Assessing the Impact of US Housing. Retrofits. Building Carbon Emissions. Building Energy Use. buildingscience.com

appendix 19 acoustic insulation requirements

THE STRANGE AND SAD STORY OF QATAR S FIRST PASSIVHAUS

Building Enclosure Details and Assemblies for Wood-Frame Buildings

LEED Building Design & Construction Contribution NC v4.0 (April, 2017)

Be Aggressive About the Passive Solutions

Understanding thermal mass

Passivhaus Project Documentation Wrexham Passivhaus

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Passive House Solutions

BC BUILDING CODE ERRATA

Energy Efficiency For Housing

Single Family Homes - over 3,000 sqft. Parfitt Residence

NEW FOUR STORY MEDICAL CENTER OWNER S PROJECT REQUIREMENTS

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

Net Zero Construction with Sean Moran of Skender Getting to Net Zero with Solar Energy

Transcription:

RESEARCH HIGHLIGHT Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings Case study: Bois Ellen Co-operative Residence, Laval, Quebec April 2016 Technical Series INTRODUCTION This Research Highlight documents the design development of a low-energy, affordable multi-unit residential building (MURB) for the Bois Ellen Co-operative Residence in Laval, Quebec. This case study is in response to growing interest in the development of energy-efficient, sustainable and affordable MURB design that benefits occupants, operators and the environment. The Bois Ellen Co-operative is a low- to mid-rise set of buildings with a six-storey wing (Y) along Robert-Élie Avenue and a thirteen-storey wing (X/Z) along the northern edge of the site. The buildings have incombustible cast-in-place concrete foundations, floor and roof slabs, columns and walls. They are clad in a combination of brick and metal panels backed up by light steel framing. The design project focused on maximizing the most appropriate sustainable principles for the Bois Ellen Co-operative s objectives and circumstances and describes the innovations that may be applied to the six-storey building that is identified as Y in figure 1. With a total of 166 units, the residents of this building will be a mix of young families and independent but less-mobile seniors. Approximately two thirds of the units will have one to two bedrooms and are designed to accommodate both independent and semi-independent seniors who range from the fully mobile to those who may need to use walkers or wheelchairs. The objectives of the design process were to identify the most strategic innovations to integrate into this MURB design to enhance the sustainability of the project with respect to the key criteria highlighted below while considering the financial limitations of the project. Figure 1 Site plan of the future Bois Ellen Co-operative Residence in Laval, Quebec (Image source: GFA/ L OEUF) Energy efficiency: the effectiveness and complementarity of building systems to achieve higher than average levels of energy performance. Comfort: designing to increase thermal comfort and enhance indoor air quality for residents. Durability: the selection and integration of durable, lowmaintenance building elements, equipment and systems that greatly reduce potential future risks, in the short and long term. Resilience: future adaptability or future proofing the selection of resilient building systems that can be adapted over the long term with changing demands on the building including changes in energy sources, climate change and severe weather events.

Given that the Bois Ellen Co-operative is heavily involved in caring for its residents, the design team was encouraged to provide the owner with a building that will require only standard levels of maintenance, straightforward operations, and an improved and durable building envelope. METHODOLOGY The integrated design process (IDP) offers housing development teams a framework whereby an interdisciplinary team of experts establishes objectives and then engages in an iterative trade-off, feedback and optimization process to achieve as many objectives as possible within given capital and operating budget restraints. The IDP charrette that was organized to develop a design for part Y of the Bois Ellen Co-operative encouraged participants to explore and consider all aspects of the project that could influence the performance criteria. Participants and stakeholders focused on the design of the building envelope, mechanical building systems, and the potential complementarity and interdependency between systems that together can further improve overall building performance and user comfort. FINDINGS The integrated design process A whole building energy consumption simulation analysis was engaged from the beginning of the design process as a useful way to understand and forecast the energy performance of the proposed building, given the many design options considered. The project team sought to use passive means to achieve energy efficiency. Passive, low-energy design principles inspired many of the technical innovations considered for this project. Many of the building science recommendations and technical innovations emerged from the collective experience of the expert consultants, client and others involved in the IDP and were applied to the following three areas of focus: 1. Improvements to the building envelope essential to the long-term energy efficiency of a building. 2. Improvements to building systems including heating, ventilation and air conditioning (HVAC), plumbing and electrical systems important to overall building performance. 3. Implementation of effective mechanisms of coordination testing and performance monitoring during the construction phase and during a year-long monitoring phase necessary to provide feedback on the success of the measures included in the building. Improvements to the building envelope Windows and doors strategic selection and installation In most building envelopes, windows and doors are weak points in the overall thermal resistance of the exterior wall assembly. For the Bois Ellen Co-operative project, it was determined that, according to the simulations of the whole building analysis, an initial investment in triple-glazed windows with a good performance frame on north-facing facades could result in significant energy savings. Insulation placement and thickness To meet or exceed the insulations values of the Novoclimat standards, the IDP team conceived an exterior wall assembly with 125 mm (5 in.) of semi-rigid outsulation (insulation situated outside of the supporting steel stud wall). This configuration has a nominal RSI of 4.4 (R-25), helps to reduce the risk of condensation and moisture damage within the wall assembly and protects the integrity of the air barrier that is placed over the exterior surface of the exterior wall sheathing. This results in a higher performing, durable building envelope system and reduces the complexity of labour and associated costs. It can also help reduce longer-term repair and maintenance costs. The whole building energy analysis for the Bois Ellen Co-operative suggested that a 125-mm (5-in.) thickness of rigid roof insulation with a nominal RSI of 5.18 (R-29.5) would be a cost-effective strategy for reducing heat loss in the winter and heat gain in the summer. Thermal bridging mitigation Mitigating thermal bridging is extremely important to ensure the overall integrity and durability of a building envelope. The overall effective insulation values of even very highly insulated wall assemblies can be significantly undermined by thermal bridges. For the Bois Ellen Co-operative, the project team focused on reducing thermal bridging in the following locations. 2 Canada Mortgage and Housing Corporation

A. Through the exterior wall insulation: The potential thermal bridge of the sub-girts that hold the exterior insulation in place and support the exterior cladding materials could be significant, due to the ubiquity of the girts on all exteriors walls, making mitigation an important goal for the project team. The team considered multiple affordable ways of minimizing this common thermal bridge, such as using non-conductive sub-girts or by using thermally broken sub-girts. B. At the structural lintels supporting the masonry cladding: Given the heavier loads carried by the structural lintels that support masonry cladding, this thermal bridge can be more difficult and costly to mitigate. The project team considered ways in which the masonry lintels could be designed so that their installation was thermally broken. For example, the team considered reducing thermal bridging by using intermittent (rather than continuous) anchoring of the structural lintels back to the building structure. As well, the team considered ways to thermally break the intermittent structural supports with gaskets and the use of other non-conductive materials while still retaining the required structural strength necessary to support the masonry cladding. C. At balconies and loggias: Fully cantilevered balconies represent major thermal bridges that often result in cold floors and ceilings where they join the floor slabs. The project team elected to use non-conductive reinforcement bars and rigid insulation at the structural joints between the concrete floor slabs and the exterior balcony and loggia slabs to reduce heat loss. Passive solar shading brise-soleil The design team proposed solar and heat gain control devices (brise-soleil) be installed on the southwest-facing building facade to permit solar heat gains in the winter, but to mitigate solar heat gains (by about 80 per cent) in the summer (figure 2). A combination of insulated glazing units (IGUs) that permit high solar gain and fixed brise-soleil assemblies attached at the exterior of the building envelope can selectively reduce solar heat gain to help reduce air conditioning loads for the greatest benefit of the building s residents. Although the fixed shading devices devised by the project team are not expected to fully eliminate summertime heat gain, their simplicity and minimal maintenance was a critical component of the decision-making process that led to their inclusion in the project design. Figure 2 Solar penetration on July 21 and December 21 on the southwest facade Section view of the southwest facade of the six-storey building at proposed fixed brise-soleil showing solar penetration at 1:30 p.m. in summer and winter. (Source: L OEUF) Canada Mortgage and Housing Corporation 3

Consideration of budget constraints versus the benefits of the installation of brise-soleil on other building facades suggested that brise-soleil on all building facades were not to be implemented at initial construction. In order to add adaptability and future-proof the building, thermally broken structural anchoring plates to support future brise-soleil were proposed. Vegetated roof The roof assembly of the six-storey building will be constructed to be ready to receive a future vegetated roof. Though vegetated roofs are proposed for the initial construction of other roofs on site, a vegetated roof could not be accommodated within the project budget for the six-storey building. A light-coloured roof membrane and root barriers for a future vegetated roof will be installed. Improvements to building systems Ventilation strategy A strategically balanced mechanical ventilation strategy was proposed for the project. This allows for partial individual control through the installation of heat recovery ventilator units (HRVs) in each unit combined with the overall benefits that can be gained from the efficiencies of centralized preconditioning of makeup fresh air (including preheating in the winter and dehumidification in the summer). Figure 3 shows how the placement of a centralized air intake at the roof of the building can benefit the quality of indoor air. On sunny days in the winter and shoulder seasons, this hybrid ventilation system is supplemented by centralized solar preheating. Plumbing strategy for water efficiency The proposed plumbing fixtures in this project were waterefficient, reduced-flow models. Additionally, heat is to be recuperated and reintegrated into the domestic hot water system from some shower wastewater. The plumbing system was also designed to allow for future conversion of hot water heating from electric to solar. Figure 3 The proposed ventilation concept for Bois Ellen: the outside air intake is located at the roof, away from common smoking areas. Air is preconditioned by a large commercial system before being supplied to the individual unit HRVs. The roof-mounted system boasts high-efficiency filtration that improves outside air quality by removing fine particulates. (Clipart smoker: free.clipartof.com. Image concept: Frédéric Genest, Pageau Morel) Resident engagement and responsibility Once the project is occupied, systems monitoring and resident engagement can make the building operations as efficient as possible. Additionally, as the systems are in part controlled by the residents and metered individually, there can be additional incentives for residents to form energy-efficient habits. Selection of low pollutant emitting materials To improve indoor air quality (IAQ), many of the affordable building materials (especially interior finishes, although not including built-in furnishings) contain low or no volatile organic compounds (VOCs). 4 Canada Mortgage and Housing Corporation

Implementation of effective measures for coordination, commissioning and performance monitoring Coordination / commissioning agent The tendering documents required that the general contractor hire a commissioning agent to ensure a coordinated and successful installation of all building systems, including the administration of warranties and maintenance programs. Durability, maintenance and varied life cycles Given the differences between mechanical systems (with moving parts) and fixed assemblies (such as most parts of a building envelope), there will invariably be variations in the durability and maintenance requirements of different building systems and elements. Such differences were taken into account in the analysis of the building s life cycle and the planning of its operation and maintenance programs. Testing for airtightness The Bois Ellen Co-operative project is targeting to achieve 0.9 air changes per hour (at 50 pascals of air pressure); a significant improvement over the Novoclimat standard for airtightness of 1.5 air changes per hour (at 50 pascals). The integrity of the exterior envelope, the airtightness between adjacent units, and between units and corridors will be tested at two times: 1. after envelope construction but before building services and interior gypsum board installation; and 2. after building services installation but before substantial completion. Monitoring the operation of windows and doors and mechanical ventilation systems The operation of doors and windows can greatly affect the heating, cooling, ventilation and air quality of a building. There is, therefore, a need to better understand occupant behaviour. Monitoring and post-occupancy evaluations of window and door operation is planned at initial occupancy, at three months, six months and one year. CONCLUSIONS The baseline case scenario analyzed for Bois Ellen projected a total energy demand of about 240 kwh/m 2 /year (22.30 kwh/ft 2 /year) with a heating demand of about 144 kwh/m 2 /year (13.38 kwh/ft 2 /year). The combined effects of implementing the energy conservation measures (ECMs) developed during the IDP for Bois Ellen resulted in a projected reduced total energy demand of about 135 kwh/m 2 /year (12.54 kwh/ft 2 /year), including a heating demand of about 43 kwh/m 2 /year (3.99 kwh/ft 2 / year). This results in a projected approximate 42 per cent reduction in overall energy use, and an approximate 70 per cent reduction in heating energy use. In this study, an integrated design process (IDP) and a whole building analysis have been valuable design tools that have facilitated the integration of environmental and sustainable measures for low- to mid-rise MURBs at the early design stage. The targeted goal of seeing if the building s final design could achieve an overall energy performance reduction of about 40 per cent over average residential energy use in Quebec was achieved. Because of the likely composition of future residents of the Bois Ellen Co-operative, a mix of seniors and young families, durable, easy-to-use and low-maintenance building systems will be included in this project. The engagement and education of the residents in the operation and maintenance of their building may also play a key role in determining the future overall energy use and energy savings. Other important goals, such as improved thermal comfort, high indoor air quality and long-term envelope durability have all been integrated into the final design, while respecting the constraints of affordability. IMPLICATIONS FOR THE HOUSING INDUSTRY Design and analysis methods, including an integrated design process (IDP) and a whole building analysis, can be useful tools used in complex building projects, such as multi-unit residential buildings (MURBs). These tools and processes can be more broadly adopted and implemented to facilitate energy-efficient and robust building designs, and this project demonstrated how energy efficiency and sustainability can affordably be incorporated into the design of low-energy MURBs without adding to future operational maintenance and building complexity. Canada Mortgage and Housing Corporation 5

Principal contributors: Daniel Pearl and Cecilia Chen, L OEUF s.e.n.c. Frédéric Genest, Pageau Morel and Associates Inc. Curt Hepting, EnerSys Analytics Inc. CMHC Project Manager: Woytek Kujawski Housing Research at CMHC Under Part IX of the National Housing Act, the Government of Canada provides funds to CMHC to conduct research into the social, economic and technical aspects of housing and related fields, and to undertake the publishing and distribution of the results of this research. This Research Highlight is one of a series intended to inform you of the nature and scope of CMHC s research. To find more Research Highlights plus a wide variety of information products, visit our website at www.cmhc.ca or contact: Canada Mortgage and Housing Corporation 700 Montreal Road Ottawa, Ontario K1A 0P7 Phone: 1-800-668-2642 Fax: 1-800-245-9274 2016, Canada Mortgage and Housing Corporation Printed in Canada Produced by CMHC 19-02-16 Although this information product reflects housing experts current knowledge, it is provided for general information purposes only. Any reliance or action taken based on the information, materials and techniques described are the responsibility of the user. Readers are advised to consult appropriate professional resources to determine what is safe and suitable in their particular case. Canada Mortgage and Housing Corporation assumes no responsibility for any consequence arising from use of the information, materials and techniques described.