Gas Analysis with a Mass Spectrometry Twist. Eric S. Oxley, Ph.D.

Similar documents
Oxygen Detection After the gas stream is purified the oxygen content is measured with a dual-range CO infrared (IR)

Bruker JUWE G8 GALILEO ONH. High-End Melt-extraction Analyzer. Elemental Analysis. think forward

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

July Table 1. General influencing trends of carbon and sulfur on the physical properties ofmetals.

Assessing Heat Treatment Carburization via the Combustion Method

CS744 Series: Carbon/Sulfur by Combustion

CS744 Series: Carbon/Sulfur by Combustion

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Chemical Threat Mitigation. Innovation with Integrity. Enhanced Environmental Mass Spectrometer: Bruker E 2 M CBRNE

Graphite and C/C Products for Semiconductor & Solar Applications

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Detecting Argon Trapped in Reference Samples Made by Hot Isostatic Pressing

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

ABB MEASUREMENT & ANALYTICS. AlSCAN and AlSCAN Argon Hydrogen analysis in liquid aluminum

Steels suitable for galvanizing

Simultaneous Oxygen, Nitrogen and Hydrogen Determination of Metals. Dennis Lawrenz, John Hawkins

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

New Castle, DE USA Lindon, UT USA Hüllhorst, Germany Shanghai, China Beijing, China Tokyo, Japan Seoul, South Korea Taipei, Taiwan Bangalore, India

Slow cooling of hot rolled bars to eliminate hydrogen induced cracks in Cr-Mo steels

Chapter 5: Atom and Ion Movements in Materials

WELDING TECHNOLOGY AND WELDING INSPECTION

Introduction: NAV 30 - FORGING PROCESS. State, Zip: Type of company ownership: Business ownership/relationship with other organizations:

Benelux Scientific Technology Days Ghent, May 6th 2015

Surface Finishing Solutions Using. High-Purity Aluminum

Aluminium & Non-Ferrous Production Optimization Fast, Reliable, Efficient

Summary of Round-robin Tests for Standardizing Hydrogen Analysis Procedures

BENCHMARKING SUMMARY BETWEEN SLM AND EBM RELATED TO POWDER RECYCLING.

Effect of Precipitation Hardening on Microstructural Characteristics of 15-5 Ph Steel

ULTRA-CUT XT SYSTEMS THE NEXT GENERATION OF HIGH PRECISION PLASMA CUTTING. We Bring Intelligence to the Table. Victor Thermal Dynamics introduces

Module-13. Corrosion and Degradation of materials

Forging Application Overview

Rev. 02. SC-71LHM Cored. FLUX CORED ARC WELDING CONSUMABLE FOR WELDING OF MILD & 490MPa CLASS HIGH TENSILE STEEL HYUNDAI WELDING CO., LTD.

revolutionary flexibility

STUDY OF HEAT TREATMENT PROCESS IN HEX BOLT

Degassing Components Unique Oxidation Resistance Treatment

Combustion Master CS Carbon and Sulphur Analyser

Carbon / Sulfur Analyzers

Learning Objectives. Chapter Outline. Solidification of Metals. Solidification of Metals

Carbon / Hydrogen / Sulfur Analyzers

Induction coils are considered the weakest link in an induction

Far-reaching efficiency.

This document is a preview generated by EVS

The Interaction between Hydrogen and Surface Stress in Stainless Steel

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY

advanced IRMS inlets Isoprime

If the zinc bath was aluminum free, a cross-section of the coating might look similar to that in Figure 1.

AquaEC Electrodeposition Coatings

Introduction. From the combination of TG and DTA or HDSC one receives a broad range of information, such as:

Thermo Scientific X-ray product range. For chemical and phase analysis of solids, liquids and powders

Thermo Scientific X-ray product range. For chemical and phase analysis of solids, liquids and powders

DETECTION AND DETERMINATION OF H 2 S AND TOTAL SULFUR IN NATURAL GAS Marshall T. Schreve Del Mar Scientific, LTD.

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Fusion

Utilizing Glow Discharge in Optical Emission Spectroscopy

Welding Job Knowledge

ULTRA-CUT XT SYSTEMS THE NEXT GENERATION OF HIGH PRECISION PLASMA CUTTING. We Bring Intelligence to the Table. Victor Thermal Dynamics introduces

Imperfections in the Atomic and Ionic Arrangements

HOT DIP GALVANIZED STEEL

Prima PRO process mass spectrometer

HOT DIP GALVANNEALED STEEL

PEER REVIEW FILE. Reviewers' Comments: Reviewer #1 (Remarks to the Author):

High-Speed Infrared Imaging for Characterization of the Additive Manufacturing Process

SIMS Analysis of Hydride in Commercially Pure Titanium

1 of 7. Leco Instruments (M) Sdn. Bhd. Sulfur/Carbon Series. Carbon/Nitrogen/Protein/Sulfur - TruMac Series

Call for tender for the "Acquisition and maintenance of an Inducted Coupled Plasma Mass Spectrometer (ICP-MS)"

GLOBAL COMPETENCE IN ALUMINIUM SOLUTIONS

Nondestructive Testing

Uddeholm Formax. Formax is a trademark registered in Sweden

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

Definition and description of different diffusion terms

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

PULSED LASER WELDING

To ensure success, this work was carried out in three phases. At first, the electrical-thermal process associated

ISO 9001:2008 Registered. 11 Metal Sourcing Tips for LNG Tanks

Analyzing & Testing. Thermogravimetric Analysis TGA. Method, Technique, Applications

EFFECT OF THE SECOND PHASE ON HYDROGEN EMBRITTLEMENT OF IRON ALLOYS

Chapter Outline: Failure

PTA WELDING SYSTEMS.

High-end stationary vacuum spectrometer. Innovation with Integrity OES

Iron Carbon Equilibrium Diagrams

Fracture. Brittle vs. Ductile Fracture Ductile materials more plastic deformation and energy absorption (toughness) before fracture.

SPECIFICATION FOR TITANIUM AND TITANIUM ALLOY CASTINGS

Improving fiber laser weld quality and yield with CleanWeld

AEROSPACE MATERIAL SPECIFICATION

METAL SPRAYING WELDING TECHNOLOGY ENGINEERING STEEL CONSTRUCTION. THe Partner for

H2scan Market Overview

Innovative Gauging. Best Practice Best Value. In-line Non-laser Non-contact. Robust. 2D/3D. Flexible. Reliable. Exact.

Oxygen/Nitrogen/Hydrogen Analyzer ONH-3000 >>>>>>>>

Gas Analysis CAPABILITIES

71T1 - Gas Shielded Flux Cored Welding Wire Provides excellent performance in all position welding. Weld Metal - Chemistry

The Callen Group of Companies. Callen Manufacturing Aluminum Die Casting

HOT DIP GALVANIZED STEEL. Agricultural Equipment. Transportation

Phase change processes for material property manipulation BY PROF.A.CHANDRASHEKHAR

Section 906. STRUCTURAL STEEL

Gas Analysis CAPABILITIES

The TOCA Ductile Iron Foundry in Dingzou

Ovality Correction Methods for Pipes

Materials of Engineering ENGR 151 CORROSION ELECTRICAL PROPERTIES

Rev. 04. Supercored 71H. FLUX CORED ARC WELDING CONSUMABLES FOR WELDING OF Mild & 490Mpa CLASS HIGH TENSILE STEEL HYUNDAI WELDING CO., LTD.

Fundamentals of Metal Forming

HOT DIP GALVANIZED STEEL. Agricultural Equipment. Transportation

Transcription:

Gas Analysis with a Mass Spectrometry Twist Eric S. Oxley, Ph.D. Innovation with Integrity

Gas Analysis with a Mass Spectrometry Twist General Topics Hydrogen a pesky little element Automotive industry driving technology Limitations of existing technology Bruker s advancement of the industry Dr. Eric S. Oxley Bruker AXS Product Manager, North America Gas Analysis 2

Primary Portfolio G4 PHOENIX DH G8 GALILEO ON/H G4 ICARUS CS HF 3

Hydrogen-Induced Failure Controlling hydrogen content is paramount Hydrogen has a negative impact on the physical properties of metals Any form of hydrogen can be detrimental Trapped hydrogen in lattice Mobile diffusible hydrogen Leads to weakening of the workpiece and the formation of cracks and pores Companies are investing in Bruker technology to help prevent these defects Instruments are being incorporated into: Material Development Process Control Quality Assurance 4

Diffusible Hydrogen Such a pesky little element Small atomic diameter of hydrogen allows easy diffusion within metal lattice Introduced during fabrication, processing, and even after production is complete Melting Casting Forging Welding Corrosion Hydrogen-induced embrittlement Hydrogen-assisted cracking Flake formation Pickling/blistering Once within lattice it has great mobility via interstitial diffusion Large pockets of high-pressure molecular hydrogen collect in metal, especially within grain irregularities Hydrogen not bound to lattice (diffusible hydrogen) can liberate and leave voids 5

High-Strength Steel Automotive industry drives new tech Auto companies, and suppliers of highstrength steel, are investing in cutting-edge hydrogen assessment technology Emphasis on minimizing fuel consumption while maintaining structural integrity Pushes development of high-strength lowalloyed steel to reduce vehicle weight and maximize fuel economy Especially susceptible to hydrogen-induced failure because it shows a high level of residual stress after cold forming Example: When steel is shaped to form contour of auto body 6

Diffusible Hydrogen Assessment G4 PHOENIX DH Dedicated Diffusible Hydrogen analyzer Analyzes steel sheets, weld coupons and many other sample configurations Rapid-heating/cooling, large infrared (IR) furnace for samples up to 30mm Utilizes a stable thermal conductivity detector (TCD) for measuring hydrogen Features direct sample analysis Conforms to AWS A4.3 and ISO 3690 Rapid, automatic 10-pt gas calibration 7

Outstanding Versatility The G4 PHOENIX DH allows you to choose a sampling method Analyze samples rapidly with integrated hot extraction furnace Collect DH with degassing canisters (Oerlikon/Yanaco) and introduce into the G4 PHOENIX 8

Complete Hydrogen Assessment G8 GALILEO ON/H Rapid Oxygen, Nitrogen, and Hydrogen assessment Utilizes TCD for hydrogen measurement HTC (High Temperature Configuration) Full automation available Crucible and Sample loading Furnace cleaning All-in-one hydrogen assessment Total Hydrogen (or Residual Hydrogen) Diffusible Hydrogen Direct temperature control of sample analysis via optical pyrometer 9

Conventional Techniques Current technology shows limitations for some applications Instruments with TC or IR detection are generally sensitive to the parts-per-million (ppm) range Thin nature of high-strength steel used in auto industry can be compromised by less than ppmlevels of hydrogen Instrumentation with better sensitivity is required Fortunately Bruker has the missing piece for this market 10

Advancing the Industry Bruker s exclusive solution Bruker has broken the sensitivity barrier by expanding their portfolio + Our G4 PHOENIX and G8 GALILEO analyzers have been coupled with external mass spectrometers Mass spectrometer acts as a secondary detector Improves hydrogen detection limits by about an order of magnitude compared to TCD and IR Maintains analysis procedures and other benefits of using the G4 PHOENIX and G8 GALILEO 11

Advancing the Industry Bruker s new Thermal Desorption Mass Spectrometry (TDMS) product line G8 GALILEO ON/H MS G4 PHOENIX DH MS 12

Advancing the Industry Bruker s TDMS features Quadrupole mass analyzer tuned for selection of hydrogen ions (e.g., m/z 2) Quadrupole Mass Analyzer Channeltron detector optimized for hydrogen sensitivity Maintains Oxygen & Nitrogen, and Hydrogen via TCD, detection capabilities Measurement of all hydrogen forms: Diffusible Hydrogen Total (or Residual) Hydrogen Channeltron Detector 13

Mass Spectrometer Signals Typical signals with G4 PHOENIX DH MS: Note: Intensity axes use same scale Intensity (cts) Intensity (cts) 0 200 Time (s) Gas dose aliquot of 5% H 2 in N 2 from gas calibration unit Approx. 0.5021mL H 2 Absolute H 2 content: 2.1 µg 0 Time (min) 12 Steel sample (50mm x 20mm x 1.3mm) Temperature ramping: 25 C 900 C, 60min Sample weight: 9.7214g H 2 concentration: 0.43 µg/g (0.43 ppm) 14

Thermal Desorption Comparison MS output from G4 PHOENIX DH-MS analysis TCD output from G4 PHOENIX DH-MS analysis 10 Intensity (cts) Intensity (volts) 0 Time (mins) 12 0 0 Time (mins) 20 Signals collected from same analysis Steel sample (50mm x 20mm x 1.3mm) Temperature ramping: 25 C 900 C, 60min Sample weight: 9.7214g H 2 concentration: 0.43 µg/g (0.43 ppm) 15

Detection Limits Finding the limits of hydrogen detection with conventional detection 10 TCD response Hydrogen Temperature Analysis Parameters Steel sample after galvanization and dezincification 50mm x 20mm x 1.3mm Temperature ramping: 25 C 900 C, 60min Sample weight: 12.8433g H 2 concentration: 0.043 µg/g (43 ppb!) Intensity (volts) No appreciable hydrogen signal measured with conventional detection (TCD). Better sensitivity is required! 0 0 Time (mins) 55 16

Outstanding Detection Limits Discovering the superior sensitivity of Bruker s TDMS Analysis Parameters Mass spectrum Same analysis as previous example Steel sample after galvanization and dezincification 50mm x 20mm x 1.3mm Temperature ramping: 25 C 900 C, 60min Sample weight: 12.8433g H 2 concentration: 0.043 µg/g (43 ppb!) Intensity (cts) Successful measurement of ppb levels of hydrogen 0 Time (mins) 12 17

Additional Literature 18

Product Support Full Demo Laboratory Hands-on demonstrations and training Consumables Compatibility with industrystandard consumables Product Specialists Sample application support Service Multiple service partners distributed throughout US, Canada and Mexico Application Notes Specific guidelines for many applications Spare Parts Ship from North American Bruker distribution centers 19

For Additional Information Bruker 40 Manning Road Billerica, MA 01821 USA (978) 663-3660 www.bruker.com Innovation with Integrity info@bruker-axs.com 20

Q&A Session Thank you for participating! If you have any questions, please submit them using the Q&A window on the right side of your WebEx viewer. Innovation with Integrity February 11, 8, 2013 21 21

Copyright Bruker Corporation. All rights reserved. www.bruker.com