Minimize Sulfur Pit Vent Contribution to Stack Emissions

Similar documents
Downsizing a Claus Sulfur Recovery Unit

Cansolv Technologies Inc. Air and Waste Management Association South Coast AQMD May 14, Rick Birnbaum

Cansolv Technologies Inc. Alberta NOx and SOx Control Technologies Symposium April 9, Rick Birnbaum

ThioSolv, LLC s SWAATS Process A Low-Cost Alternative for increasing SRU Capacity ThioSolv, LLC, Spring Branch, TX ph:

Treatment Options for Molten Sulfur

Refinery SRU s Tail Gas Handling Options. 2 nd Middle East Sulphur Plant Operations Network Forum Abu Dhabi October 18-20, 2015

Dow Oil, Gas & Mining

GT-LPG Max SM. Maximizing LPG Recovery from Fuel Gas Using a Dividing Wall Column. Engineered to Innovate

SO 2 Clean for SRU Expansion

WWT Two-Stage Sour Water Stripping

Taravosh Jam Design & Engineering Co.

SULPHUR RECOVERY BY TAIL GAS TREATING TECHNOLOGY (MCRC PROCESS) MAXIMUM CLAUS

by: Steven M. Puricelli and Ernesto Vera-Castaneda MECS, Inc USA

GTC TECHNOLOGY. GT-UWC SM How a Uniting Wall Column Maximizes LPG Recovery. Engineered to Innovate WHITE PAPER

SRU-TGTU Analyzer Best Practices. RefComm Galveston 2016 Sulfur Recovery

Brownfield Projects. Equinox Engineering

2011 BRIMSTONE SULFUR SYMPOSIUM. Fundamentals 2011: Ammonia Destruction in SRU Furnaces

Fate of Ammonia in Refinery Amine Systems

Corrosion in GASCO Habshan CBA Units and its mitigation

Sulfur Recovery. Chapter 16 Based on presentation by Prof. Art Kidnay

D GAASS TM Sulfur Degasification Process Update

White Paper. Solutions to Contain VOC Emissions and Comply with Evolving EPA Regulations.

Natural Gas Processing Unit Modules Definitions

Sulsim Sulfur Recovery in Aspen HYSYS V9 A Brief Tutorial for Using and Optimizing Your Sulfur Recovery Unit in Aspen HYSYS

February 2017 SCOT ULTRA POWERS PERFORMANCE

CANSOLV SO2 Scrubbing System - 10 Years of Reliable Operation Integration with SRU Tail Gas Incineration

The Cost of Mercury Removal in an IGCC Plant

COLLECTION AND INCINERATION OF HIGH VOLUME-LOW CONCENTRATION PULP MILL NONCONDENSIBLE GASES

Sulfur Recovery Catalysts

SYNTHETIC NATURAL GAS PLANT. Philadelphia, PA

Petroleum Refining. Environmental Guidelines for. Multilateral Investment Guarantee Agency. Industry Description and Practices. Waste Characteristics

The COPE TM Process Increase Sulfur Recovery Capacity to Meet Changing Needs

September 2010 API Recommended Practice

Instructor s t Background

Advanced Sulfur Technologies for Mega Size Sulfur Complexes in Arid Environments. Presented by Thomas Chow

SULPHUR PLANT TAIL GAS INCINERATORS IN ALBERTA A SURVEY OF CURRENT OPERATING PRACTICE AND OPPORTUNITIES TO REDUCE FUEL GAS CONSUMPTION

The types of industrial exhaust streams that present particular pollution-control challenges include:

AMINE GAS SWEETENING & SULPHUR RECOVERY

Study evaluates two amine options for gas sweetening

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control

Salt deposition in FCC gas concentration

Catalytic Abatement Plant

Amine Plant Energy Requirements & Items impacting the SRU

Methanol Production by Gasification of Heavy Residues

Process Gas Monitoring In Petroleum Refineries

Cansolv Technologies Inc.

Challenges in Industrial Waste Heat Recovery. Texas Technology 2006 Showcase Tony Dafft December 6 & 7, 2006

PROClaus: The New Standard for Claus Performance

Using SWSPlus for Sulfur Capacity Addition

Guidelines for acticat Presulfurized Catalyst

Valorisation of Synthesis Gas from Biomass - the Piteå DME pilot. Esben Lauge Sørensen, May 2009

CRYOGENIC SOLVENT ABATEMENT (VOC s )

SUEZ helps refineries to save time, reduce energy consumption, emissions and waste by efficient decontamination

Oxygen Enrichment of Sulfur Recovery Units to Boost Capacity, Conserve Capital, and Improve Environmental Performance

TANK/PIPELINE DEGASSING SYSTEM BACT Size: Minor Source BACT THERMAL OXIDIZING UNIT - PORTABLE. BACT Determination Information

Item Hydrogen Gas Plant

Odorless pulp mill in successful operation

Delayed Coker Blowdown System Water Reuse

BEST AVAILABLE CONTROL TECHNOLOGY & TOXIC BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

Corrosion monitoring solution for sour water stripping units

Statement of Basis. Daikin America, Inc. Morgan County Decatur, Alabama

Successful SmartSulf unit starting up at PEMEX Salamanca Refinery

Post Combustion CO 2 Capture Scale Up Study

Claus plants. SURE oxygen enrichment portfolio for sulfur recovery in

Carbon Capture Options for LNG Liquefaction

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

SANTA BARBARA COUNTY APCD GUIDANCE DOCUMENT FOR EMISSION VERIFICATION OF CONTAMINATED SOIL/GROUNDWATER CLEANUP (CSC) PROCESSES

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

HOW PYROLYSIS WASTE TO ENERGY WORKS

DESIGN CONSIDERATIONS FOR NATURAL DRAFT VENTILATION IN MOLTEN SULFUR STORAGE TANKS

T-125 EVOLUTION OF THERMAL REMEDIATION. Technical Paper T-125. EVOLUTION OF THERMAL REMEDIATION by Wendell R. Feltman P.E.

Quality water. Powerful results.

Wastewater Recycling Plants with Zero Effluent Discharge. Water Recycling Plants

Hydrogen is a particularly

MECS SULFOX High Energy Efficient Sulfuric Acid Process Technology for cleaning up Lean & Wet Sulfurous Off-gasses

Topsøe Methanol Technology for Coal Based Plants

A Better Approach To Energy Performance Benchmarking

Quality water. Powerful results.

Case No. 601: Reducing NOx Emissions from Nitric Acid Manufacturing Plants with NOx Abatement or NSCR

A Presentation Prepared For: PROCESS COMBUSTION CORPORATION

Latest Development of Lurgi s MPG-technology Update on Hydrogen Unit for NWU Project

DIESEL HYDRODESULPHURISATION UNIT CHAPTER-9 CATALYST AND REGENERATION

TGTU Catalyst In-situ Presulphiding. Fernando Maldonado Business Manager Gas Treating Catalysts

Guidelines for acticat Presulfurized Catalyst

Methane Emission Reductions in Oil and Gas Processing

ADVANCED PROCESS CONTROL QATAR GAS ONE YEAR EXPERIENCE

HYDROGEN GENERATION FOR MODERN REFINERIES

Sandhya Eswaran, Song Wu, Robert Nicolo Hitachi Power Systems America, Ltd. 645 Martinsville Road, Basking Ridge, NJ 07920

Industrial Gas Analyzers in Applications Information

REDUCING SULFUR DIOXIDE EMISSIONS DOWNSTREAM OF AMINE UNITS WITH DRY SORBENT INJECTION

Integrated processes for converting coal to chemicals and fuels. Maninder Jit Singh Haldor Topsøe

Chemistry of Petrochemical Processes

TRONDHEIM CCS CONFERENCE

Fossil Energy. Fossil Energy Technologies. Chapter 12, #1. Access (clean HH fuel) Coal. Air quality (outdoor)

Using a Process Simulator to Improve Sulphur Recovery

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes. a technical solution to meet every need

Overview of pinch analysis and its application in hydrocarbon Industries

RULE GASOLINE AND ROC LIQUID STORAGE TANK DEGASSING OPERATIONS (Adopted 11/8/94)

Achieving Process Energy Efficiency via Innovation Honeywell. All rights reserved.

SURE Double Combustion Increases Capacity at the. Tesoro Northwest Company Sulfur Plant (Anacortes, WA)

Transcription:

Minimize ulfur Pit Vent Contribution to tack Emissions Grant Qui, P.E. Excel Paralubes - ConocoPhillips 2800 Old panish Trail 3008 MO Westlake, LA 70609 Houston, TX 77079 Al Keller Refining Technical ervices - ConocoPhillips 337-491-5464 281-293-3168 Grant.Q.Qui@conocophillips.com Al.E.Keller@conocoPhillips.com Abstract O 2 stack emissions approaching the EPA rolling 12 hour average of 250 ppmv limited the capacity of two parallel 90 LTPD RU/TGU trains at the ConocoPhillips Lake Charles Manufacturing complex. Using data from a performance test by Brimstone T on the RU/TGU and sulfur storage pit, a plan was developed to reduce TR and sulfur pit vapor emissions allowing increased acid gas throughput. Individual plan steps and subsequent positive results are discussed. Introduction ulfur recovery units have environmental limits on emissions from the sulfur plant stack. These limits include a concentration limit such as 250 ppmv O 2 on 12 hour rolling average corrected at zero percent excess air or a mass limit in pounds O 2 emission per hour. There are two sulfur containing gas streams normally going to the sulfur plant stack. The first one is the process gas from the tail gas amine absorber overhead, which is then routed to the incinerator (thermal oxidizer) for H 2 destruction and enters the stack. The other sulfur containing gas stream going to the incinerator is the pit vent gas. The pit vent gas carries H 2 released from liquid sulfur by natural degassing or forced degassing in the sulfur pit (or storage tank) to keep the sulfur storage safely below the lower explosion limit (LEL) of 3.7% H 2 in the vapor space. Both sources contain sulfur compounds and contribute to O 2 emissions in the stack. When O 2 emissions in the stack are near the maximum limit, the operators typically cut back the flow of pit vent gas. However, this may lead to blocking in the pit vent gas inadvertently, allowing H 2 containing gases to emit to the atmosphere, resulting in personal H 2 exposure and possible sulfur pit fire/explosion. This article is a summary of the effort to quantify the relative O 2 contribution to the stack from process gas and pit vent gas. It also describes an effort to minimize the pit vent gas contribution while maintaining a safe and reliable sulfur plant operation. Figure 1 shows a typical Claus process and sulfur rundown diagram using an underground storage pit. The process gas from tail gas amine absorber overhead and

the pit vent from sulfur storage pit are the two sources that contribute to stack O 2 emissions. In the sulfur pit, the dissolved H 2 and H 2 x in liquid sulfur from waste heat boiler and sulfur condensers are stripped with sparging air and oxidized to form elemental sulfur and O 2. ulfur vapor, O 2 and unconverted H 2 are swept to the thermal oxidizer. Figure 1: Claus Process and ulfur Rundown: Acid Gas Feed WHB To Tail Gas Air 1st Cond. 2nd Cond. 3rd Cond. 4th Cond. parging Air Degassing section Degassed sulfur Pit Vent To Thermal Oxidizer The problem The Lake Charles Refinery Manufacturing Complex has sulfur processing capacity including 4 Claus/TGU trains, a sulfuric acid plant, and an off-site NaH plant. The loss of a significant amount of capacity in any one of these units can impact the overall sulfur balance in the refinery which may require adjustments in upstream unit rates including crude units, hydrodesulfurization units, FCC, Coker units or sometimes to shut down wash water to HD units or sour water processing units (sour water strippers) temporarily. Crude slate changes and higher severity of hydrotreating for cleaner diesel and gasoline can also add more acid gas feed to the RUs. Any constraints in sulfur processing units such as RU stack emission constraints are not desirable. ulfur plant stack emission will naturally go up over time as the Claus catalyst or the tail gas hydrogenation bed catalyst ages slowly losing its activity. When a sulfur plant can not run the rate it used to run, there will be an intensified effort to review sulfur plant operation and troubleshoot for sulfur plant emission problems. A lower sulfur stack emissions also supports our core value of reducing pollution!

Figure 2 shows the stack O 2 was trending higher near the maximum 250 ppm in April / May 2010 and the unit could not run the rate demonstrated in the first half of 2009. Figure 2: RU O2 emissions vs. feed rate. RU O2 Emission vs. feed ppm O2 and MCFH feed 300 250 200 150 100 50 0 Design Rate constrained by emissions 1/1/09 3/2/09 5/1/09 6/30/09 8/29/09 10/28/09 12/27/09 2/25/10 4/26/10 6/25/10 8/24/10 O2 ppm Feed The troubleshooting effort started with determining the O 2 sources to the stack. This lead to a number of optimization adjustments in operating temperatures from Claus and hydrogenation bed inlet temperatures. The most significant reduction of stack O 2 emission came from reducing liquid sulfur temperature and lowering the pit sweep gas flow rate. O 2 Mass Balance Brimstone T were brought in to conduct sample analysis in 2007. Data was used to establish optimum operating conditions and benchmark the sulfur plant process gas and pit vent emission contributions. ummary data are listed below for the sulfur rundown and gas streams. ulfur Rundown Dissolved, ppm ample ource H 2 H 2 X Total RU WHB Rundown 440 196 636 RU Cond 1 Rundown 263 285 548 RU Cond 2 Rundown 58 53 111 RU Cond 3 Rundown 12 10 22 RU Cond 4 Rundown 2 1 3 RU Degassed (pit) 42 41 83

Process Gas and Pit Vent Gas Analysis ample ource H 2,ppm CO, ppm O 2, ppm RU Absorber OVHD 30~50 100~130 - RU ulfur Pit Gas 200 ~900 <80 200~600 To determine the O 2 mass balance, the pit vent gas was blocked away from thermal oxidizer temporary. The process gas contribution to stack was measured with the thermal oxidizer analyzer. Process flows with and without pit sweep were generated (see Figure 3 for the block diagram and flow conditions). ARU gas 145 W gas 25 Claus Unit Tail Gas Unit Hydro. Rx inlet = 550 F Abs OH gas 311 Fuel gas 18 Thermal Oxidizer 3.0% O2 190 ppmv O2 Air 285 parge air 2.0 ulfur made 127 TPD Pit Vent 22 ulfur Pit Molten sulfur temps: 303 F degassing pit 291 F storage pit Pit sweep air 20 Figure 3: Process conditions with pit vent gas

1. With pit vent to thermal oxidizer, T.O., with flows in MCFH in () Estimated flow to T.O. : = Abs ovhd gas (311) + fuel gas (18) + air (285) + pit vent (22) = 636 MCFH O 2 at T.O.: 190 ppmv. O 2 volume = 636 MCFH* 190 ppmv = 120.8 CFH or /379 * 64 = 20.4 lbs/hr 2. Without pit vent to thermal oxidizer Estimated flow to T.O.: = Abs ovhd gas (311) + fuel gas (16) + air (264) + pit vent (0) = 591 MCFH. O 2 at T.O.: 110 ppmv. O 2 volume = 591 MCFH * 110 ppmv = 65 CFH or /379 * 64 = 11 lbs/hr 3. Equivalent O 2 concentration in process gas: = 65 scfh/311 MCFH = 209 ppmv The equivalent O 2 concentration (209 ppm) was higher than the normal expected level and the analytical test results in the past (30 ppm H 2 and 100 ppm CO). CO was believed to be formed in the hydrogenation reactor where unconverted CO from the water gas shift reaction participated with H 2 to form CO and H 2 in the sour gas shift reaction. Adjustment was made to increase hydrogenation bed temperature to increase CO destruction in the hydrogenation bed. The Claus bed temperatures were also optimized based on the above calculation. 4. Equivalent O 2 concentration in pit vent: The O 2 contribution from pit vent was calculated with the results from step 1 and 2. The O 2 volume from pit vent = O 2 volume with pit vent (120.8) - O 2 volume without pit vent (65) = 55.8 CFH. The equivalent O 2 concentration in the process gas: = O 2 volume (55.8 scfh) /pit vent volume (22 ) = 2536 ppmv The equivalent O 2 concentration of 2536 ppm in the pit vent was very high comparing to the design concentration of 350 to 900 ppm H 2 and 350 to 550 ppm sulfur mist (The analytical test in 2007 showed 200 to 900 ppm H 2, 200 to 600 ppm O 2. ulfur mist was not included). Amount of sulfur mist and sulfur vapor in the pit vent exceeded the design by about 1000 to 1500 ppm. Higher liquid sulfur temperature and higher pit sweep flow can carry excess sulfur mist and sulfur vapor to the pit vent and thermal oxidizer. A step test was conducted to lower the degassing pit liquid sulfur temperature and reduce the abnormal high pit vent flow to a comfortably safe level.

tep Test There are two ways to reduce the temperature of liquid sulfur from the sulfur condensers: a sulfur cooler if it is available and/or reduce the steam pressure of the sulfur condensers (typically 50 psig steam pressure). For a sulfur pit degassing operation, a sulfur cooler is provided to cool the liquid sulfur from the sulfur condensers to about 275 o F in order to achieve the optimum degasification. For our case, the sulfur cooler is no longer available due to plugging problems. The steam pressure from the sulfur condensers is the handle we chose. The steam pressure was reduced from 57 psig to 53 psig. The sulfur pit temperature dropped about 5 o F as a result. What is the proper volume of pit vent gas? Criteria for proper volume of pit vent should include: 1) Achieve vacuum condition in pit at all time (no H 2 exposure in the pit area), 2) maintain less than 3.7% LEL of H2 in pit vapor space (no pit fire and/or explosion) and 3) minimize elemental sulfur carrying over to thermal oxidizer (no excess stack emissions). The pit vapor sample analysis in 2007 showed 200 to 900 ppm H2 in the pit vent with pit vent flow at 24 MCFH. The concentration was far less than the 3.7% H2 LEL. An operating envelope can be defined from LEL and safety margin consideration (25% of LEL considered acceptable). For a 180 LTPD design capacity of sulfur unit with sulfur degassed from 400 ppm to 10 ppm H2, the minimum pit vent flow at LEL can be defined: ulfur production 180 LTPD *2240 /24 hr *390 ppm /34 MW *379 /3.7% = 2 MCFH. The safe operating window can be ~8 MCFH based on 25% of LEL. A modification on pit flow control was done to lower the pit vent flow. Below are the test steps and observed responses: Dissolved H 2 + H 2 x in liquid sulfur Degassing efficiency Unconverted H 2 + H 2 x to pit vent ulfur vapor ulfur mist tack O 2 Liquid ulfur Temperature from 300 o F to 295 o F ulfur Pit Vent Flow from 22 to 15 15 ppm 30 ppm With a lower sulfur temperature and lower sulfur pit vent flow, the overall stack O 2 emission was reduced by about 50 ppm. Unit rate was regained back to the design rate.

RU O2 vs. feed O2, pp m 250 200 Before After 150 100 110 130 150 Feed 170 190 210 230 250 Conclusion Excess sulfur plant stack emissions can be caused by different reasons. We often focus on catalyst activities and amine absorption efficiency during troubleshooting and forget about the sulfur mist and vapor carrying over to the thermal oxidizer. The O 2 contribution from the pit vent was found to be about 50% from mass balance. With a lower sulfur temperature and defining better operating window for the pit vent flow, we can achieve a lower O 2 emission and improve unit rate. References 1. ulfur Recovery Unit Test Run Report, by Brimstone T, February 2007. 2. hell ulfur Degasification Units for ulfur Recovery Unit Goar, Allison & Associates, Inc. eptember 1994.