Solar Powered Air Conditioning System

Similar documents
Stand-Alone Photovoltaic (SAPV) System Assessment using PVSYST Software

Available online at ScienceDirect. Energy Procedia 110 (2017 ) 89 94

Analysis of Solar Irradiance and Solar Energy in Perlis, Northern of Peninsular Malaysia

Available online at ScienceDirect. Energy Procedia 91 (2016 )

INVESTIGATION ON THE EFFCETIVE USE OF SOLAR ENERGY FOR SOLAR AIR- CONDITIONER

Optimal integrated diesel grid-renewable energy system for hot water devices

Analysis of Solar Thermal Cooling System Using TRANSOL

Performance of a photovoltaic solar container under Mediterranean and arid climat conditions in Algeria.

Available online at ScienceDirect. Energy Procedia 110 (2017 )

Design and Manufacturing of Solar Air Conditioning.

Available online at ScienceDirect. Energy Procedia 70 (2015 )

NORTH PROJECT AQABA, JORDAN. Recommended Energy Efficiency and Renewable Energy Measures for the Premium Villa

Reference: Photovoltaic Systems, p. 229

Design and Performance Analysis of a Grid Connected Solar Photovoltaic System

S.R.ELECTRONICS (SOLAR AIR CONDITIONER WITH COOLING & HEATING) SAVE THE WORLD FROM GLOBAL WARMING

Nocturnal radiation cooling tests

Analysis of Heat Gain in Computer Laboratory and Excellent Centre by using CLTD/CLF/SCL Method

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Solar Radiation Potential as Energy Source of Photovoltaic Powered Uninterrupted Power Supply in Perlis, Northern Malaysia

AN EMPIRICAL APPROACH TO SAPV SIZING IN TROPICAL ISLANDS Sendanayake, S 1., Jayasinghe, M.T.R 2

BCE Program March-2017 Electrical Power Systems Time: min Quiz 1 Model A رقم المجموعة:

Simulation of Solar Thermal Cooling System for an Office Building in Indian Climates using Evacuated Tube Collector

Design and Development of Hybrid Power Generation System

Available online at ScienceDirect. Transportation Research Procedia 14 (2016 )

A New Technique of Photovoltaic/Wind Hybrid System in Perlis

Techno-economic Analysis of Solar Photovoltaic Cooling System: an analysis in four different climates in India

Investigation on Temperature Coefficients of Three Types Photovoltaic Module Technologies under Thailand Operating Condition

Application of Photovoltaic Cells as a Power Supply for Smart Greenhouse Project

Website:

Comparative Study of Photovoltaic Modules and Their Performance in the Tropics: A Case Study in Nigeria

Study on Water-Cooled Solar Semiconductor Air Conditioner

An Investigation of a Grid-Connected Solar Powered Water Pumping System. Mohammed Shadman Salam I.D:

Fresh air pre-cooling and energy recovery by using indirect evaporative cooling in hot and humid region a case study in Hong Kong

Optimization of a solar photovoltaic applied to greenhouses

FEASIBILITY EVALUATION OF SOLAR REFRIGERATION SYSTEM: A CASE STUDY

A Modified Heat Pump Air-Conditioning System for Electric Vehicle

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 20 26

From the Agent. In This Issue

Contents. What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

Available online at ScienceDirect. Energy Procedia 91 (2016 )

The Novel Solar Water Heating by Means of Thermoelectric Modules

NCSC Focal Theme Science, Technology & Innovation for Sustainable Development Sub theme- Energy By

Experimental Investigation on Heat Pump for Electric Vehicles with different refrigerant injection compressors

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

PHOTOVOLTAICS HISTORY OF PHOTOVOLTAICS

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Contents. What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

Design optimization of solar powered aeration system for fish pond in Sleman Regency, Yogyakarta by HOMER software

Simulation and economic analysis of solar cooling for building in tropical climate of Surabaya, Indonesia

Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

A Method for On-Going Commissioning of VRV Package Systems Using a. Simulation Model

SOLAR TRAINING MANUAL (INTERMEDIATE)

Available online at ScienceDirect. Energy Procedia 50 (2014 )

Evaluation of Solar PV and Wind Alternatives for Self Renewable Energy Supply: Case Study of Shrimp Cultivation

Solar chilled drinking water sourced from thin air: modelling and simulation of a solar powered atmospheric water generator

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

Heat pumps. WP5 Education and Economic Promotion

Available online at ScienceDirect. Energy Procedia 90 (2016 )

Radiant energy from the sun has powered life on Earth for many millions of years.

Experimental investigation on a ceiling capillary radiant heating system

Simulation of Solar Air-Conditioning System with Salinity Gradient Solar Pond

Effect of Thermoelectric Cooling (TEC) module and the water flow heatsink on Photovoltaic (PV) panel performance

SOLAR PV-DRIVEN AIR CONDITIONER

Residential Solar Energy Systems: Solar Hot Water and Solar PV. Darren C. Anderson, MSc Renewable Energy Director of Operations Sungrid Ltd

Available online at ScienceDirect. Energy Procedia 78 (2015 )

future-proof energy with photovoltaic systems

Solar Absorption Aqua-Ammonia Absorption system simulation base on Climate of Malaysia

Design and life cycle cost analysis of a SAPV system to electrify a rural area household in India

SOLAR ASSISTED HVAC HVAC

Rural Electrification Through Solar and Wind Hybrid System: A Self Sustained Grid Free Electric Power Source

Welcome Everyone. Not Quite this kind! Geothermal Heat Pumps are a indirect solar heating system! Introduction to Geothermal

GPC ONE PLANETS CONSULTANTS LTD

Available online at ScienceDirect. Energy Procedia 57 (2014 )

Performance enhancement of a photovoltaic thermal (PVT) and ground-source heat pump system

EXPERIMENTAL STUDY ON THE REPLACEMENT OF HFC-R134A BY HYDROCARBONS MIXTURE IN AUTOMOTIVE AIR CONDITIONER. Skudai, Johor, Malaysia 81310

ANet Quiz RI.4.2 English Language Arts, Grade 4

COMPANY PROFILE. Energy Srl Piazza Manifattura, Rovereto TN Italy

Advanced HVAC Technologies. Electricity Producing Air Conditioning (E-HVAC) Integrated Power Generation and Liquid Desiccant HVAC System

Optimization of Solar Cooling Systems with Simulation Modeling

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Design, Fabrication and Experimental Study of a Novel Loopheat-pipe based Solar Thermal Facade Water Heating System

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

Instant discount of 33% off improvement cost, up to $1,250 Plus, potential savings bonus of up to $250 (**)

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

REPORT ON THE BENEFITS OF ICE- BASED THERMAL STORAGE FOR DISTRICT COOLING IN THE UAE MARKETS

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Application of Low Cost Active and Passive Energy Saving Technologies in an Ultra-low Energy Consumption Building

Design of Grid Connected PV System Using Pvsyst

IJRASET: All Rights are Reserved

Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Ch 13 Achieving Energy Sustainability

Solar Power Vs. Nuclear Power. By: G. H C. P S. J

Geothermal Heating and Cooling Overview. Why should I consider it?

THE PTM ZEO BUILDING

Design of Hybrid Power Generation Using Solarpv Module and Wind Turbine

CFD and Wind Tunnel Study of the Performance of a Multi- Directional Wind Tower with Heat Transfer Devices

Fact sheet. Photovoltaic systems. Why consider photovoltaics?

Transcription:

Available online at www.sciencedirect.com ScienceDirect Energy Procedia 36 (2013 ) 444 453 TerraGreen13 International Conference Solar Powered Air Conditioning System I. Daut a, M. Adzrie a, M. Irwanto a, P. Ibrahim a, M. Fitra a, a Centre of Excellence for Renewable Energy, School of Electrical System Engineering, Universiti Malaysia Perlis, Taman Pengkalan Indah, Jalan Pengkalan Assam, 01000 Kangar, Perlis, Malaysia. Abstract The development of renewable energy is on the rise worldwide because of the growing demand on energy, high oil prices, and concerns of environmental impacts. In recent years, progress on solar-powered air conditioning has increased as nowadays, air conditioning system is almost a must in every building if we want to have a good indoor comfort inside the building. Therefore, this paper focuses in the design and construction of a direct current (DC) air conditioning system integrated with photovoltaic (PV) system which consists of PV panels, solar charger, inverter and batteries. The air conditioning system can be operated on solar and can be used in non-electrified areas. As we all known, solar energy is cost effective, renewable and environmentally friendly. 2013 2010 The Published Authors. Published by Elsevier by Elsevier Ltd. Ltd. Selection Open access and/or under peer-review CC BY-NC-ND under license. responsibility of TerraGreen Academy Selection and/or peer-review under responsibility of the TerraGreen Academy Keywords: Solar; Direct current, Air conditioning system 1. Introduction The demand of air conditioning is increasing due to the effect of climate change and global warming. If we still rely on the conventional electric air conditioning but electricity is generated form fossil fuels, the greenhouse gas emission would continuously worsen global warming, in turn the demand of air conditioning would be further increasing. In subtropical cities, air conditioning is a standard provision for buildings. However, air conditioning would commonly take up half of building electricity consumption [1]. 1876-6102 2013 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and/or peer-review under responsibility of the TerraGreen Academy doi:10.1016/j.egypro.2013.07.050

I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 445 Air conditioning is defined as the simultaneous processing of temperature, humidity, purification and distribution of air current in compliance with the requirement of space needing air conditioning [2]. In general, air conditioning which also can be known as refrigeration is defined as any process of heat removal. To produce the process, it requires energy where the sources are commonly gas and electricity. With increasing gas and electricity tariffs, solar energy becomes attractive once the system has been installed [3]. As one of the sources of renewable energy, solar energy is likely the most suitable system for installation in sub-tropical countries. The most common globally, preferred type of thermally driven technology is absorption cooling. The system, which has simpler capacity control, mechanism, easier implementation, high reliability, silent operation, long life and low maintenance cost was a genuine candidate for efficient and economic use of solar energy for cooling applications [3]. But in this project concentrates on development and improvement of a normal air conditioner unit in order to operate using electricity generated from the PV system. Utilizing solar energy to run the air conditioning system is a practical technique to replace conventional electricity. In order to obtain a feasibility of the air conditioning system using solar, a lot research and testing have been initiated to learn and discover the design and operation of the air conditioning and solar system which is consist of PV system. The purpose of this paper is to design and construct a direct current air conditioning system besides describe the component and characteristics of the system including its advantages and limitations. The actual performance of the system will be studied based on operational view and commercial applications. 2. Methodology The approaches used in this project are based on suggestion by Tsoutsos et al [4], and are as follows: a) Collection of the required meteorological data: meteorological data for Perlis was used. A typical meteorological year (TMY) was created and the hourly, monthly and annual values of solar radiation processed. b) Cooling load calculation: Determine what kind of cooling and how much of cooling needed. c) Design and sizing of the air conditioning system: Using the weather data, and the selected design conditions, the components of the system could be sized. d) Optimisation of the system: The aim was to use least cost energy so the designed system was optimised with that in mind. e) Material procurement and construction of the experimental system: Once the system had been optimised, the components were procured and the system was constructed and tested. f) Performance evaluation and economic analysis: The energetic and economical effectiveness of the system was evaluated. The life cycle costs for solar cooling system were calculated and competitiveness with regards to price and thermal efficiency for domestic applications determined. g) Analysis of results and making of recommendations: The results were analysed and necessary improvements recommended. Options for improving technical effectiveness and economic competitiveness were suggested. Ways of improving research and development efforts in this field were also investigated.

446 I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 3. System Description The proposed concept of the system consists of air conditioner and PV system is indicated in block diagram shown in Figure 1. In order to determine the characteristics and properties of all the components used, each component must be taken as a single unit. The complete system must be able to operate in stable condition, and if possible achieving the efficiency as conventional air conditioning system. For example, as for the cooling purpose, performance of the DC air conditioning should be the same as normal AC air conditioner. PV Module Balance-of-system Charge Controlle r Batteries Air Conditioner Fig. 1. Block diagram of PV system and air conditioning system 3.1 Refrigeration Load Heat naturally flows from warmer places to cooler places. In other words, the heat is called as refrigeration load. Refrigeration equipment such as air conditioner is used to transfer heat from a cooler place to a warmer place. For example, the heat inside a house is absorbed and been transferred to the outside [4]. The refrigeration load is the rate at which heat must be removed from the refrigerated space in order to produce and maintain the desired temperature conditions. The total cooling load on the refrigerating equipment is the sum of heat-gain from several different sources which include the heat gained from walls, windows and doors [5].

I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 447 There are several factors need to be considered in determining the cooling load [4]. The factors are for instance: Site size and construction of the cooling area Human presence human body continuously produces heat through a process called as metabolism. Activity level sleeping and dancing inside of an area will give a different rate of heat. Equipment printers, computers, etc contribute the heat 3.2 Air Conditioning System Either for a building or a vehicle, the air conditioner mainly consists of five key components which are compressor, refrigerant, expansion device, evaporator and condenser [4]. As shown in Figure 2, compressor is electrically operated can be described as the heart of air conditioning system as it pump refrigerant throughout the system. The main function of a compressor is to compress refrigerant vapour to a high pressure, making it hot for the circulation process of the refrigerant. Fig. 2. Air conditioner compressor Refrigerant is a material that performs as cooling agent by absorbing heat into the system and will circulating inside the circuit of the air conditioning system. Located in between of the condenser and evaporator, the expansion device allows a controlled amount of the liquid refrigerant to flow through into the low-pressure section of the process. Figure 3 illustrates the expansion device used in air conditioning system in vehicle.

448 I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 Fig. 3. Expansion device for air conditioning system in vehicle For the circulation process of the refrigerant, evaporator use the liquid state refrigerant to absorbs the heat from the cooling space into the system. As shown in Figure 4, the evaporator is located inside the indoor unit installed in the cooling area. Fig. 4. Evaporator coil At condenser, as the temperature of the refrigerant is low, the heat from the system that the evaporator absorbs is being removed. Presented in Figure 5, the condenser is situated inside outdoor unit with the compressor.

I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 449 Fig. 5. Condenser coil 3.3 PV System Even though there is many differences of the PV processes now either in research of commercial areas, the basic principle is simple. Photovoltaic which is combination of two words; photo for light and voltaic for electricity, converts the energy of sunlight directly into electricity. The conversion from the sunlight into electricity is occurred because of the PV effect. The term solar cell is reserved for devices intended specifically to capture energy from sunlight while the term photovoltaic cell is used when the light source is unspecified [7]. A complete PV system comprises two subsystems. First subsystem is the PV modules that convert sunlight into electricity. In between the first subsystem and air conditioner, there will be second subsystem which is a set of devices and structures that enables the PV electricity to be properly applied to the load. This third subsystem is known as balance of system or the BOS [8]. PV module is categorized according to their rated power output in Watts. This rating is the amount of power the solar panel would be expected to produce in 1 peak sun hour (PSHs). Different geographical locations receive different quantities of average peak sun hours per day [7].

450 I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 The peak sun hour is essential in order to know the number of PV modules to be installed. Before doing so, the power that can be assumed generated by the PV modules must be determined based on solar irradiance of the location. Fig 6. PV module The BOS in this system consists of inverter, charge controller and battery. The function of charger is to regulate the voltage and current coming from the solar panel going to the battery. The battery is the key components in PV-SA systems as it act as energy back-up for the renewable energy systems. It also functions as storage devices for storing PV generated electricity during cloudy days and at night. In order to apply this system in AC load, the inverter is needed to convert the DC electricity generated by the PV panel into AC. The AC load is a common type of load and easily available with cheaper in price. It is important when it comes to getting the right batteries and maintaining them. Economical and maintenance factors are the common issue to select suitable battery. The battery storage must have enough capacity to handle the energy demands by the system especially during periods of very low solar radiation. Rainy day, cloudy weather and at night are examples for the period of low solar radiation. Usually, for PV system, a deep cycle battery is usually used because it is specifically designed to be discharged over a long period of and recharged hundreds or thousands of times.

I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 451 Fig 7. Deep cycle battery The purpose of charge controller is to regulate the current from the PV module to prevent the batteries from overcharging. A charge controller is used to sense when the batteries are fully charged and to stop, or decrease, the amount of current flowing to the battery. Charge controller as in Figure 5 is rated by the amount of current they can receive from the solar panels [7]. Fig 8. Charge controller 3.4 System Operation The solar energy is received by the PV module and transform into electrical energy. The electrical energy is then being regulated by charge controller either by supplies it directly into the load or charges the batteries. As the electrical energy coming from the PV module is in DC, inverter will convert it into AC as the compressor needs AC to operate. The most common type of air conditioning is technically referred to as direct expansion, mechanical, vapour-compression refrigeration system. The goal with air conditioning is to capture heat in the cooling space and throw it outside [6]. The operation of the system starts when the cold, low pressure liquid (refrigerant) flows across the evaporator coil inside the cooling space to absorb heat. The cold liquid that

452 I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 went into the evaporator coil comes out as a low pressure gas. Then, the cool, low pressure gas is taken outside and compressed by the compressor to become a hot, high pressure gas. Next, the hot gas is passed through the condenser coil and gives off some of its heat as outdoor air is blown across the coil. This cause the hot gas to condense back to into a warm liquid. The warm liquid is carried back to the evaporator by passing through the expansion device which decreases the temperature and pressure of the liquid. Figure 4 shows the basic air conditioning operation. Fig 9. Air conditioning system [1. Condenser; 2. Expansion device; 3. Evaporator; 4. Compressor] 4. Conclusion This paper concludes that the system design needs to consider both air conditioner and PV system in order to achieve the space cooling. There are several characteristics that are needed to know either on the PV system or air conditioning system. Electrical equivalent, IV characteristic curve and factors affect the output of PV cell is an important characteristic in photovoltaic. As for the air conditioning, cooling capacity must be determined first as it will give a rough idea on how to design and construct the system with enough electrical energy supplied to it. With considering of these several factors, it will help to improve the stability and efficiency of the system for greener solutions to the world s energy needs. Acknowledgements The authors would like to express gratitude to the Centre of Ecellence for Renewable Energy, Universiti Malaysia Perlis for the technical and financial supports and those who involved in this research.

I. Daut et al. / Energy Procedia 36 ( 2013 ) 444 453 453 References [1] IPCC Fourth Assessment Report. Intergovernmental Panel on Climate Change; 2007. [2] Ochi, M.; and Ohsumi, K. Fundamental of Refrigeration and Air Conditioning: Ochi Engineering Consultant Office; 1989. [3] Bvumbe, J.; and Inambao, F. L. Solar Powered Absorption Cooling System for Southern Africa. University of Kwazulu- Natal, Durban, South Africa; 2011. [4] Tsoutsos, T.; Aloumpi, E.; Gkouskos, Z.; and Karagiorgas, M. Design of a Solar Absorption Cooling System in a Greek Hospital. Energy and Buldings; 2009. [5] McDowall, R. Fundamentals of HVAC Systems. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc and Elsevier Inc., 1st edition; 2007. [6] Tau, S.; Khan, I.; and Uken, E. A. Solar Assisted Space Cooling. Domestic Use Of Energy Conference; 2002. [7] Saad, S. S.; Daut, I.; Misrun, M. I.; Champakeow, S.; and Ahmad, N. S. Study of Photovoltaic and Inverter Characteristics. Univeristy Malaysia Perlis (UniMAP); 2010. [8] Ahmad, N. S. Development of Solar Water Pump for Small Scale Paddy Field Irrigation. University Malaysia Perlis (UniMAP); 2010. [9] Lang, V. P. Principles of Air Conditioning. Thomson Learning; 1995. [10] S. Shaari, A.M. Omar, A.H. Haris, S.I. Sulaiman and K.S.Muhammad. Solar Photovoltaic Power: Design and Installation of Stand-Alone Systems, Pusat Tenaga Malaysia; 2009, pp. 46-52, 119-129.