MCINTOSH COUNTY SCHOOLS TODD GRANT (K-5) SCHOOL DEMOLITION AND FINISHED SITE WORK

Similar documents
Attachment A-Flagpole(s) Specifications

SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole.

SECTION FLAGPOLES

D I V I S I O N 10: S P E C I A L T I E S

SECTION VISUAL DISPLAY SURFACES

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION METAL STAIRS

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

A. Access doors and frames are part of an access door and frame allowance.

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION TURBINE VENTILATORS

SECTION MISCELLANEOUS METALS

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION ALUMINUM GATES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS


SECTION DECORATIVE METAL AND GLASS RAILING

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION METAL STAIRS

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION METAL STAIRS

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

A. This Section includes the following: 1. Aluminum pipe and tube handrails and railings.

SECTION AWNINGS

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION ROOF SPECIALTIES

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ACCORDION FOLDING PARTITIONS

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

G. Shop drawing of wall with all dimensions, details, and finishes. Drawings must include post foundations.

SECTION CHAIN LINK FENCES

SECTION ALUMINUM RAILINGS

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

A. American Society for Testing and Materials (ASTM):

SECTION OVERHEAD COILING SHUTTERS

SECTION ROOF ACCESSORIES

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

SPECIFICATIONS Section Gable Walkway Covers

The City of Winnipeg SECTION ST. VITAL LIBRARY RENOVATION PROJECT 6 FERMOR AVE. Page 1 of 5

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION WALL AND DOOR PROTECTION

ITEM 442 METALS FOR STRUCTURES

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH GLASS INFILLS

Preassembled steel stairs with concrete-filled treads.

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

Trex Commercial Products page Metal Railing

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

SECTION HANGERS AND SUPPORTS FOR PLUMBING

PIPE AND TUBE RAILINGS

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION (10705) EXTERIOR SUN CONTROL DEVICES

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION ARCHITECTURAL PRECAST CONCRETE. A. American Society for Testing and Materials (ASTM):

Section PANEL SIGNAGE

SECTION METAL FABRICATIONS

Architectural Roof and Wall Products Guide Specifications

SECTION HVAC GRAVITY VENTILATORS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION PRECAST CONCRETE COVER SYSTEM

Work Order Number *************************************************************************** SECTION C20 STAIRS 02/18

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION ORNAMENTAL ALUMINUM RAILINGS PART 1 - GENERAL 1.01 SUMMARY

Ultra Aluminum Fence, Rail & Gate Specifications

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION VISUAL DISPLAY BOARDS

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

CONCRETE WALKS AND CURBS SECTION CONCRETE WALKS AND CURBS PART 1 - GENERAL

Item 442 Metal for Structures

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION PIPE AND TUBE RAILINGS

Transcription:

MCINTOSH COUNTY SCHOOLS TODD GRANT (K-5) SCHOOL DEMOLITION AND FINISHED SITE WORK ADDENDUM NO. 2 DATE: April 18, 2016 John A. Tuten & Associates, Inc. 4680 Hwy 17 North Brunswick, GA 31525 PROJECT MANUAL 1. SECTION 103500 - FLAGPOLES A. ADD Section 103500 Flagpoles dated April 18, 2016 to the Project Manual. END OF ADDENDUM NO. 2 Attachments: Section 103500 1301\160\160418AddendumNo2 ADDENDUM NO. 2 Page 1 of 1

SECTION 103500 FLAGPOLES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work of this Section. 1.02 SUMMARY A. Extend and location of each type of flagpole shown on drawings. 1.03 SUBMITTALS A. Product Data: Submit manufacturer's technical data and installation instructions for each type flagpole required. B. Shop Drawings: Submit shop drawings of flagpoles and bases, showing general layout, jointing and complete anchoring and supporting systems. C. Samples: Submit samples of each finished metal for flagpoles, and accessories as may be requested. 1.04 QUALITY ASSURANCE A. Manufacturing Standards: Provide each flagpole as complete unit produced by single manufacturer, including fittings accessories, bases and anchorage devices. B. Design Criteria: 1. Provide flagpoles and installations constructed to withstand wind velocity when flying flag of appropriate size. Code requirements See Sheet S0.1. 2. Capable of mounting one 3 x5 flag and one 6 x10 flag. 3. Use heavy pipe sizes if required for flagpole type and height shown. C. Pole Construction: 1. Construct pole and ship to site in one piece if possible. 2. If more than one piece necessary, provide snug-fitting, precision joints with selfaligning, internal splicing sleeve arrangement for weather-tight, hairline field joints. 1.05 DELIVERY, STORAGE AND HANDLING A. Spiral wrap flagpoles with heavy Kraft paper or other protective wrapping and prepare for shipment in hard fiber tube or other protective container. B. Deliver flagpoles and accessories completely identified for installation procedure. FLAGPOLES 103500-1

C. Handle and store flagpoles to prevent damage or soiling. PART 2 - PRODUCTS 2.01 MANUFACTURERS A. Manufacturer: Subject to compliance with requirements, provide products of one of following: 1. Aabec Pole Div., Morgan-Francis Co. 2. Acme Flagpole Div., Lingo Inc. 3. American Flagpole, Div. of Kearney-National. 4. Baartol Co., Inc. 5. Concord Industries, Inc. 6. Eder Flag Manufacturing Co. 7. Pole Tech 2.02 FLAGPOLE TYPE A. Aluminum Flagpoles 1. Fabricate from seamless extruded tubing, complying with ASTM B 241, alloy 6063-T6, having min. wall thickness of 3/16" (0.1875"), min. tensile strength of 30,000 psi and yield point of 25,000 psi. 2. Heat-treat and age-harden flagpoles after fabrication. 3. Pole Height: exposed height 40 feet. 4. Provide Entasis tapered aluminum flagpoles. 2.03 FLAGPOLE MOUNTING A. Provide manufacturer's standard base system for type flagpole installation required. B. Base Plate: 1. For anchor-bolt mounting, furnish manufacturer's standard cast metal shoe base of same material as flagpole. 2. Furnish and install anchor bolts and lightning ground spike as required. C. Foundation Tube: 1. For ground-set flagpoles, proved 16-gage minimum galvanized corrugated steel tube, or 12 gage rolled steel tube, sized to suit flagpole and installation. 2. Furnish complete with welded steel bottom base and support plate, lightning ground spike, and steel centering wedges, all welded construction. 3. Provide loose hardwood wedges at top for plumbing pole after erection. 4. Galvanize steel parts after assembly, including foundation tube. 5. Provide manufacturer's standard flash collar, finished to match flagpole. 6. Provide steel ground protector extending 12" above ground and 6" below ground for steel flagpoles where base or flash collars not provided.

2.04 SHAFT FINISH A. Aluminum: Fine, directional, mechanical satin polish (NAAMM-M32), finished as follows: 1. Buff and seal aluminum surfaces with clear, hardcoat wax Clear anodized 2.05 FITTINGS A. Finial Ball: Manufacturer's standard flush seam ball, size as indicated, or if not indicated, to match pole butt diameter. 1. Stainless steel, bright polished. B. Truck: Ball-bearing non-fouling, revolving, double-track assembly of cast metal, finished to match pole shaft. C. Cleats: Two 9" cast metal cleats with fasteners, finished to match pole shaft. D. Halyards: Provide 2 continuous halyards for each flagpole, as follows: 1. Nylon, braided, with metal core. 2. Size: (a) 5/16" (No. 10). E. Halyard Flag Snaps: Provide 2 swivel snaps per halyard, as follows: 1. Chromium-plated bronze PART 3 - EXECUTION 3.01 INSTALLATION A. Excavation: 1. Excavate for foundation concrete to neat clean lines in undisturbed soil. 2. Provide forms where required due to unstable soil conditions. 3. Remove wood, loose soil, rubbish and other foreign matter from excavation, and moisten earth before placing concrete. B. Concrete: 1. Provide concrete composed of Portland cement, coarse and fine aggregate and water, mixed in proportions to attain min. 28-day compressive strength of 3000 psi, complying with ASTM C 94. 2. Place concrete immediately after mixing. 3. Perform chuting to avoid segregation of mix.

4. Compact concrete in place by use of vibrators. 5. Moist-cure exposed concrete for min. 7 days, or use non-staining curing compound in cold weather. 6. Finish trowel exposed concrete surfaces to smooth, dense surface. 7. Provide positive slope for water runoff to base perimeter. C. Flagpole Installation: 1. Install flagpoles as shown and in compliance with final shop drawings and manufacturer's instructions. 2. Provide positive lightning ground for each flagpole installation. 3. Paint portions of ground-set flagpole below grade with heavy coat of bituminous paint. END OF SECTION 103500