C-130 HERCULES COMPOSITE FLAPS FATIGUE TEST PROGRAM

Similar documents
Damage Assessment in Aerospace Grade Carbon Fiber Composites subjected to Drop Weight Mechanical Impact

Principles for determining material allowable and design allowable values of composite aircraft structures

A SIFT approach for analysing failure by delamination and disbonding in composite structures

Certification Aspects of Large Integrated Bonded Structure

DAMAGE ACCUMULATION IN COMPOSITE STRUCTURES UNDER REPEATED LOADS

DEVELOPMENT OF XF-2 FIGHTER COMPOSITE STRUCTURES (COCURED COMPOSITE WINGS)

Subject Index. Broadgoods, 64 Buffer strips, 5

Damage Tolerance Workshop

Load Introduction into Aerospace Structures

CURVATURE EFFECTS ON THE DAMAGE TOLERANCE OF IMPACT DAMAGED COMPOSITE SANDWICH PANELS

Synergy between Advanced Composites and New NDI Methods

Composite Structures some basic issues and principles. Dr Barbara Gordon Consultant - University of Bristol

A NEW APPROACH TO EVALUATE DURABILITY AND DAMAGE TOLERANCE FOR AIRCRAFT COMPOSITE STRUCTURES

Bearing and Delamination Failure Analysis of Pin Loaded Composite Laminates

COMPOSITE LANDING GEAR COMPONENTS FOR AEROSPACE APPLICATIONS

AN AXIAL TENSILE TEST OF COMPOSITE STIFFENED PANELS WITH TWO MAN-HOLES AFTER IMPACT

Structural development and optimization of rotor blades for wind turbines Lessons from the aerospace industry. Josef Mendler Christoph Katzenschwanz

Composites methods development under the next generation composite wing (NGCW) research programme

LOAD RESPONSE AND FAILURE OF THICK RTM COMPOSITE LUGS

Proof of Concept for New Composite Structures of Aircraft

RESPONSE OF COMPOSITE FUSELAGE SANDWICH SIDE PANELS SUBJECTED TO INTERNAL PRESSURE AND AXIAL TENSION

Damage-Tolerance Characteristics of Composite Fuselage Sandwich Structures With Thick Facesheets

BEHAVIOR OF COMPRESSION-LOADED COMPOSITE PANELS WITH STRINGER TERMINATIONS AND IMPACT DAMAGE

QUALITY SYSTEM DEVELOPMENT FOR THE MANUFACTURE OF PRIMARY COMPOSITE AIRCRAFT STRUCTURE

NUMERICAL ANALYSIS OF BUCKLING AND POST BUCKLING BEHAVIOR OF SINGLE HAT STIFFENED CFRP PANEL

Exploratory Investigation of Failure Mechanisms in Transition Regions between Solid Laminates and X-cor Truss Sandwich

Natural Laminar Flow Flight Demonstrator (NLFFD)

Analysis and optimization of Composite Sandwich Structures using Optistruct

SPECIALTY MATERIALS, INC.

State-of-the-art Nondestructive Inspection Technology for Composite Materials

FAA Workshop on Adhesive Bonding. Ch. KAUFFMANN Head of Technology Department

1 American Institute of Aeronautics and Astronautics

Design and Testing of Wing Leading Edge of a Light Transport Aircraft

EVALUATION OF THE STRUCTURAL RESPONSE AND FAILURE OF A FULL-SCALE STITCHED GRAPHITE-EPOXY WING

THE CFRP SAILPLANE WING SEGMENTS MANUFACTURED BY FILAMENT PLACEMENT

FATIGUE LIFE ASSESSMENT FOR COMPOSITE MATERIALS

The Joint Advanced Materials and Structures Center of Excellence

Design of a High-g Unmanned Aerial Vehicle Structure

CURVED BEAM TEST BEHAVIOR OF 3D WOVEN COMPOSITES

Structural Stability of a Stiffened Aluminum Fuselage Panel Subjected to Combined Mechanical And Internal Pressure Loads. Ralph E. Gehrki.

Evaluation of a Composite Sandwich Fuselage Side Panel With Damage and Subjected to Internal Pressure

In-Service Inspection Concept for GLARE An Example for the Use of New UT Array Inspection

Composite. Background Damage threat assessment. Larry Ilcewicz CS&TA Federal Aviation Administration July 19, 2006

IMPACT RESISTANCE AND TOLERANCE OF INTERLEAVED RTM LAMINATES

Strength Prediction Technology for Composite Materials Simulating Damage Phenomena

Marian A. GIZEJOWSKI Leslaw KWASNIEWSKI Wael SALAH

COMPRESSIVE AND SHEAR PROPERTIES OF POLYAMIDE HONEYCOMB CORE

ON MINIMISING THE OBTRUSIVITY OF AN OPTICAL FIBRE SENSOR WITH RESPECT TO MATRIX CRACKING

Boeing Perspectives on Safe Composite Maintenance Practices

Ultrasonic Testing Of Carbon Epoxy Laminate Ply Drop

RESEARCH IN PROGRESS: FATIGUE OF CFRP COMPOSITES

STRUCTURAL DESIGN ON WING OF A SMALL SCALE WIG VEHICLE WITH CARBON/EPOXY AND FOAM SANDWICH COMPOSITE STRUCTURE

FRACTURE BEHAVIOR OF CFRP SPECIMEN AFTER LIGHTNING TEST

TENSION / TORSION FATIGUE BEHAVIOR OF UNIDIRECTIONAL GFRP AND CFRP

NUMERICAL ANALYSIS ON BEARING BEHAVIOR OF COMPOSITE BEAM WITH OPEN-HOLE

Development and Qualification of Composite Tail Rotor Drive Shaft for the UH-60M

Effects of Repair p Procedures on Bonded Repairs of Composite Structures

MECHANICAL PROPERTIES OF TRIAXIAL BRAIDED CARBON/EPOXY COMPOSITES

Airbus Damage Tolerance Methodology

Ultrasonic Measurements of the Elastic Properties of Impacted Laminate Composites

Disclaimer for FAA Research Publication

Finite Element Analysis of Carbon Fibre Reinforced Aircraft Wing

Contents FUNDAMENTALS OF STRUCTURAL ANALYSIS. Section A1 Elasticity... 3

TOOL MATERIAL EFFECTS ON PROCESS INDUCED DEFORMATION OF COMPOSITE SPAR STRUCTURES

MECHANICAL TEST FIXTURES

PREDICTION OF OPEN HOLE COMPRESSIVE FAILURE FOR QUASI-ISOTROPIC CFRP LAMINATES

A Study on the Skin-Stringer Panel of an Aircraft

Comparison of Novel Resin Transfer Moulding, Pre-Preg Autoclave and Metallic CNC Manufacturing for UAV Spars. Composites Centre

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

Subject Index. STP1156-EB/Jun. 1993

CHAPTER 3 EXPERIMENTAL INVESTIGATION

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

Structural design of a composite aileron using a multi-step integrated procedure

IMPACT DAMAGE DETECTION ON SCARF-REPAIRED COMPOSITES USING LAMB WAVE SENSING

Determination of through thickness properties for Composite thick laminate S.Vali-shariatpanahi * * Stress Engineer/Durability group leader -Airbus

Influence of Ductility Ingredients of Structural Adhesives on Fracture Energy under Static Mixed-Mode Loading 1. Introduction

OPTIMIZATION OF UNMANNED AERIAL VEHICLE WING STRUCTURE

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

DURABILITY PERFORMANCE OF EPOXY INJECTED REINFORCED CONCRETE BEAMS WITH AND WITHOUT FRP FABRICS

FAILURE OF PULTRUDED GRP ANGLE-LEG JUNCTIONS IN TENSION

Delamination/Disbond Arrest Features in Aircraft Composite Structures JAMS Technical Review

Composite materials for wind turbine blades. Department of Mechanical, Chemical and Materials Engineering University of Cagliari, Italy

DEVELOPMENT OF GEODESIC COMPOSITE AIRCRAFT STRUCTURES

SMART Wind Consortium

Part 4 MECHANICAL PROPERTIES

INTERNATIONAL TASK GROUP. Chapter 3

DESIGN METHODOLOGY FOR BUCKLING OF THIN-WALLED LAMINATED COMPOSITE BEAMS

DAMAGE TOLERANCE TEST METHOD DEVELOPMENT FOR SANDWICH COMPOSITES

SD3-60 AIRCRAFT MAINTENANCE MANUAL

Research Article Volume 6 Issue No. 8

Thermography- A Tool for Understanding Dynamics of Destructive Testing in Composites

STRENGTHENING OF TUNNEL SUPPORTS USING CARBON FIBRE COMPOSITES

REVISIONS LIST OF EFFECTIVE PAGES

MECHANICAL PROPERTIES OF COMPOSITE SANDWICH STRUCTURES WITH CORE OR FACE SHEET DISCONTINUITIES

SD3-60 STRUCTURAL REPAIR MANUAL CRITICAL BASELINE STRUCTURE

FAA level II Composite Structural Engineering Safety Awareness Course Materials and Process Control Module A Historical Perspective

SKIN-STRINGER SEPARATION IN GLARE COMPOSITE AEROSPACE PANELS

Constituents Core Materials

Use of CFRP for Strengthening Steel Structures & Bridges

EGR-Contents. Standard Retractable Gear Contents. June 2005 EGR-Contents Page 1

Transcription:

C-130 HERCULES COMPOSITE FLAPS FATIGUE TEST PROGRAM J. Ayling Hawker de Havilland Pty Ltd 361 Milperra Road, Bankstown, New South Wales, 2200, Australia SUMMARY: The C130 Fatigue Test Program was a task undertaken by Hawker de Havilland to satisfy the Federal Aviation Authority certification requirements. This involved a coupon fatigue test program to quantify the fatigue threshold for the Hexcel T650/F584 material used in the design of the flaps and a component fatigue test program to demonstrate that the flaps design has satisfactory structural performance. Damage that could be expected from manufacture and service was also considered in both test programs, this included barely visible and visible impact damage. The coupon fatigue test program determined that the material fatigue threshold occurred at a nominal strain of 3400 µε being above the allowable design strain. The component fatigue test, with the inclusion of impact damage at two structurally critical sites, was completed without incident and with no damage growth. All testing was completed by December 1997 and LMAS received final type certification for the C-130J Hercules transport aircraft from the FAA on 9 th September 1998. KEYWORDS: C-130 Flaps, Certification, Fatigue and Impact Damage. INTRODUCTION On the 9 th September 1998 Lockheed Martin Aeronautical Systems (LMAS) received final type certification for the C-130J Hercules transport aircraft from the Federal Aviation Administration (FAA). Hawker de Havilland (HdH) won a competitive contract from LMAS to redesign, test and manufacture the C-130 Hercules centre and outboard flaps in early 1995. The redesign was necessary to achieve satisfactory performance in a severe acoustic-operating environment caused by the engine propeller wash and exhaust. The redesign maximised the use of carbon fibre reinforced plastic (CFRP) material and optimised the structural configuration to resist high cycle fatigue and support air and inertial loading. The structural configuration is a conventional multi-rib design being quite similar to its metal predecessor. The front and rear spar, ribs and skins are made up of carbon fibre solid

laminates, which are predominately quasi-isotropic throughout. configuration of the centre wing flap. Fig. 1 presents the Fig 1: Structural Configuration of Centre Wing Flap As part of the overall C-130J type certification extensive structural qualification testing was performed. This included static testing of the centre and outer flaps, main spar and rib components, lightning strike of the flap skin and flight-testing. The static testing considered the possible structural performance degradation resulting from the environment (hot wet conditions) and impact damage that could arise during manufacturing, maintenance and service. However to demonstrate full compliance to FAA regulations, in particular Federal Airworthiness Regulation (FAR) 25.571(b) Damage Tolerance Evaluation, a fatigue test program was required. This test program involved testing at the coupon level, along with a full-scale substructural test article representing a critical region of the flaps. This paper outlines the methodology used to assess the fatigue performance of the composite flaps with induced damage, that could possibly arise from manufacture and service, at two structurally critical sites. The aims of the program were twofold: 1. To determine the fatigue threshold for the material, with barely visible impact damage (BVID), that was used in the design and 2. To demonstrate that the composite flaps meet the FAA s fatigue requirements. COUPON FATIGUE TEST PROGRAM Hexcel T650/F584 carbon epoxy material is used in the manufacture of the composite flaps. The majority of the parts in the flap structure consist of quasi-isotropic lay-up configurations; consequently a quasi-isotropic laminate was used to quantify the fatigue characteristics of the carbon epoxy material. A total of twenty tests were performed at the coupon level. Each coupon was nominally 152 mm (6 inch) long by 102 mm (4 inch) wide, consisting of 24 plies with the following laminate configuration: [(0/90), (±45)] 6S. Every coupon was impacted with BVID at the coupon centre using a 20 mm (0.8 inch) diameter tup and support conditions similar to test document NASA 1142, except a 102-mm (4-inch) square window was used.

Damage was considered barely visible when the depth of the impact site was a minimum of 0.25-mm (0.010-inch), which required an energy of 37 Joules (27 ft-lbs). This type of impact resulted in an average damage size through the thickness of the coupon of 38.1-mm (1.5-inch). Each coupon then had four strain gauges bonded, two back-to-back sets to monitor bending effects, located at 25 mm (1 inch) from the edge, width-wise, and 76 mm (3 inch) from the edge, length-wise. Five coupons were statically loaded in compression until failure to determine the average failure load for the laminate with induced damage. From these static test results, three load levels were calculated and the remaining coupons were tested using constant amplitude cycling with an R ratio of 10 and a frequency of 5 Hz. To ensure statistical confidence in the results, five coupons were fatigue tested at each load level. Each coupon was supported to prevent buckling, in both the static and fatigue tests; these anti-buckling supports were designed not to inhibit the growth of the BVID site in each coupon. In both the static and fatigue tests all coupons failed in a similar manner. During the fatigue tests the following similarities were observed: 1. During the initial stages of cycling, the surface of the coupon at the impact site was observed to be protruding outwards as the coupon was compressed. 2. Once initiation of the damage growth was visually detected it was found that the protrusion would grow across the full width of the specimen. 3. Upon initiation the damage growth rate appeared to be quite rapid. Fig. 2: Typical Coupon Test Installation

Fig. 2 presents the typical test setup for each coupon and Fig. 3 presents a through transmission ultrasonic (TTU) C-scan of a coupon with BVID before and after testing, including a sectional view of the damaged region. Fig. 3: TTU C-scan of a typical coupon before and after test & sectional view of damage site Fig. 4 presents the results of the coupon fatigue test program. The aim of this program was to develop the fatigue life curve and determine the strain level corresponding to the fatigue threshold (defined as one million cycles by LMAS) for the Hexcel T650/F584 material. It can be seen in the figure that a nominal strain of ~3400 µε corresponds to the fatigue threshold of one million cycles. Coupon Fatigue Life Curve 140 120 100 80 60 40 20 Load Level Data Nominal Strain Level Data 7000 6500 6000 5500 5000 4500 4000 3500 ε µε 0 3000 1.E-01 1.E+00 1.E+01 1.E+02 1.E+03 1.E+04 1.E+05 1.E+06 1.E+07 Cycles to Failure Fig. 4: Hexcel T650/F584 Material Coupon Fatigue Life Curve

FULL-SCALE SUB-STRUCTURAL FATIGUE TEST PROGRAM A full-scale sub-structural test article representing the most critical region of the composite flaps was used to demonstrate adequate fatigue life and static structural performance of the design. Finite Element Analysis (FEA) of the flap design determined the structurally critical region to be the most inboard main spar cutout of the outer wing flap. Representative flap structure was incorporated into the test article including nose ribs, aft ribs, upper skin and lower skin in an effort to replicate the flap s structural behaviour around the cutout. Consideration was also given to how the test article should be loaded. Originally it was intended to load the test article as a cantilever beam however unless the load was applied through the shear centre of the spar unfavourable twisting, not representative of actual flap structural behaviour, would result. Consequently this was aborted due to the possible instability that could occur during the test. The final solution was a four-point bend test configuration that could be tailored to minimise the twist of the spar (fig. 5). In this configuration the test article is simply supported at the spar end lugs and at the end of the torsional members forward of the nose ribs. The load was applied directly above the nose ribs, any twist would be restrained by the stiffness of the torsional members. Fig. 5: Spar Sub-Component Fatigue Test Article

The test article was impacted with the same tup used for the coupons to produce BVID and visible impact damage (VID) at two predetermined sites prior to testing. For both impacts a 6- mm (0.25-inch) compressed board and steel reaction surface was used to support the back face. BVID was impacted adjacent to the spar web cutout corner, which exhibited the lowest margin of safety from the FEA. An energy of 8 Joules (6 ft-lbs) was required which resulted in a damage size through the thickness of the spar web of 11-mm (0.45-inch) in diameter. The reasoning for BVID at this location was that barely visible damage could possibly occur during handling and assembly. VID was impacted at a location along the upper spar cap flange where the maximum bending cap strain occurred as predicted by the FEA. An energy of 136 Joules (100 ft-lbs) was required resulting in a damage size through the thickness of the spar cap of 25-mm (1-inch) in diameter. Under four point bending the test article underwent: - 1. Spectrum fatigue for the equivalent of one lifetime followed by a static test to ultimate load to validate the structural performance of the BVID site. 2. A contact pulse echo ultrasonic (A-scan) on the VID site. 3. Further spectrum fatigue for the equivalent of three inspection intervals followed by a static test to limit load to validate the structural performance of the VID site. 4. A-scan of the VID site after the static test. Fatigue testing of the two damage sites was performed sequentially because the strain fields required at the two sites were unfortunately not coincident for the corresponding loads. Since testing was conducted under room temperature ambient conditions, a load enhancement factor of 1.19 was used to increase the static loads to account for any possible material degradation that would result from elevated temperatures and humid conditions. Fig. 6 presents the test article in the Instron testing machine. Fig. 6: Test Article Installation

Testing of the spar sub-component was completed successfully without incident. Pathology was performed on the two impact sites and it was found that the VID damage site had not grown in size during and at the completion of testing. The BVID site did exhibit growth indicating that the damage size was now 19 mm (0.75 inch) as compared to the original damage size of 11-mm (0.45-inch). However it was shown, with the assistance of the coupon fatigue life curve, that this damage growth was attributed to the overloading of the BVID site during the VID fatigue test and therefore was not a cause for concern. IMPACT DAMAGE DEVELOPMENT WORK Extensive development work was carried out to determine the correct energy levels required, with the corresponding support conditions, to produce consistent BVID. For all impacts a 20- mm (0.8-inch) diameter tup was used. Varying types of support conditions were used for impacting the coupons this involved using different materials to support the non-impact surface and impacting over an open window. It was determined that the impact energy was a function of the laminate thickness and the support conditions. Also the size of the damage was a function of the impact depth irrespective of the support conditions and energy used to achieve it. Therefore depth of impact should be used as a basis to quantify impact damage rather than energy. In order to facilitate the certification process however it was agreed to use a known test standard for the support conditions; consequently the National Aeronautics and Space Administration (NASA) reference publication 1142 was used. This standard is designed to produce compression after impact specimens and comprised of clamping each coupon about its periphery and impacting over an open window. The coupons used in the fatigue test program were smaller in size; thus the impact test apparatus was modified to suit. CONCLUSIONS The coupon fatigue test results showed that the strain level corresponding to the endurance limit for the material with BVID was above the allowable strains used in the design. Also nondestructive inspection of the sub-component test article indicated no measurable damage growth at the impact sites. Consequently the test program successfully met the FAA requirements demonstrating that the C-130 flap design is insensitive to fatigue and has excellent damage tolerance capability. REFERENCES 1. NASA 1142, NASA/ Aircraft Industry Standard Specification for Graphite Fiber/ Toughened Thermoset Resin Composite Material, 1985.