UTILITY NOTES GENERAL CONSTRUCTION NOTES PAVING AND GRADING NOTES: TREE PROTECTION NOTES

Similar documents
INVITATION TO BID ITB/FFS-15/16-79 CONSTRUCTION OF A BUILDING FACILITY AT INDIAN LAKE RANGER STATION

NORTH OF THE PROPERTY ON BOYETTE ROAD, PUBLISHED ELEVATION 92.29' (NAVD88).

CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413

BASE BID FORM FY 2015

CONSTRUCTION PLANS FOR ENTERPRISE RENTAL CAR

CITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST ADDRESS: DATE:

GENERAL NOTES ROADWAY CONSTRUCTION RD0001-1A ISSUED:2017 REVISED: --

CONSTRUCTION PLAN CHECKLIST


SITE PLAN NOTES 1. MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED FROM VIEW WITH HEDGE.


Port KC RFP NORTHLAND PARK BUILDING V

West Energy Sanitary Sewer in Columbia, SC State Project # H27-Z185-CP Prepared For. Chao & Associates, Inc.

SEMINOLE TRIBE OF FLORIDA PURCHASING DEPARTMENT RFB MABEL T FRANK WAY ROADWAY CONSTRUCTION BIG CYPRESS INDIAN RESERVATION

CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS

Index. Composition and Order of Plan Set. Utility Plan... 5

CONSTRUCTION SURVEY. Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following:

HYDROLOGIC RESTORATION OF THE CASH CREEK BASIN IN TATE'S HELL STATE FOREST

36 JASPER THPMAS ROAD CRAWFORDVILLE, FL.

This is only a general checklist; please refer to the CVWD Development Design Manual (DDM) for all requirements and regulations.

City of Redwood City Stormwater Pollution Prevention Program. Drainage Guidelines for Residential Development

PART II - SURVEYING AND GRADING CRITERIA

IMPROVEMENT PLANS FOR CITY OF RIO VISTA CONDITIONAL USE PERMIT NO

CITY OF ELKO BID TABULATION FOR Sports Complex

LOT GRADING GUIDELINES FOR COMMERCIAL, INDUSTRIAL, INSTITUTIONAL, MEDIUM AND HIGH DENSITY RESIDENTIAL PROPERTIES

Engineering Standard Minimum Checklist

ENGINEERING REVIEW CHECKLIST City of Mount Clemens

Appendix K: Soil Erosion and Sedimentation Control Plan Check List

Florida Department of Environmental Protection Bureau of Design and Construction 3540 Thomasville Road Tallahassee, Florida 32309

STATE UNIVERSITY CONSTRUCTION FUND

PUBLIC WORKS STANDARD DETAILS

EXHIBIT A FEE SCHEDULE

CITY OF URBANA CLASS 2 EROSION CONTROL PERMIT STANDARD DETAILS

2015 Financial Assurance (Basic form) 3/17/2015 Estimate Form

T a b l e o f C o n t e n t s

GENERAL PLAN OF SERVICING

PART V - STORM DRAIN DESIGN CRITERIA

PART V - STORM DRAIN DESIGN CRITERIA

CONSTRUCTION PLAN REVIEW CHECKLIST FOR PRIVATE DEVELOPMENT

WAKULLA SITE PLANNING

PUBLIC WORKS DEPARTMENT GENERAL NOTES

CONDITIONS EXISTING EXISTING CONDITIONS SURVEY PROVIDED BY EGAN, FIELD & NOWAK ON FEBRUARY 20, PRELIMINARY - NOT FOR CONSTRUCTION

LOT GRADING. LOT GRADING REQUIREMENTS The following lot grading requirements came into effect on May 1, 2007:

E.P. CLARKE ELEMENTARY SCHOOL SITE IMPROVEMENTS

CUSTOM HOMES, ADDITIONS TAYLOR BUILDING & COMMERCIAL DESIGNS 63 KENSINGTON ROAD, SAN ANSELMO, CALIFORNIA SPIRIT LIVING GROUP APN

580-1 Wells Road, Orange Park, Florida 32073

CITY OF ALBANY Public Works Department ADDENDUM #1 ST CROCKER LANE RECONSTRUCTION

FDOT REF. ITEM DESCRIPTION

Chapter 3 Dispersion BMPs

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance

RESTORATION SPECIFICATION

Item Name Description Unit of Measure Mobilization Per WSDOT Lump Sum

EROSION CONTROL GENERAL NOTES EC JAN 2017 C.B.

PROPOSED STOCK PILE YARD PHASE 1 SITE: MYRA FALLS MINE

ROYAL AVENUE. Wat. San. MH. Wat. Wat San. Rim = I.E. = Existing Curb Opening. Wat. Wat. San. San. San. gas. gas. gas.

WASTEWATER REVIEW CHECKLIST. Project Number: Reviewed By: Telephone:

TOWN OF MANCHESTER PLANNING AND ZONING COMMISSION Subdivision Application Minimum Submission Requirements

Stormwater Management The District exercises regulatory authority for Stormwater Management in the City of Edina.

November 29, CITY OF PLANT CITY Purchasing Division (813)

PRELIMINARY DEVELOPMENT PLAN INFORMATION

ENGINEERING PERMIT APPLICATION SUBMITTAL CHECKLIST SINGLE FAMILY RESIDENTIAL STRUCTURE

DRAINAGE SUBMITTAL CHECKLIST

County of Georgetown, South Carolina

SOIL TRACKING PREVENTION DEVICE TYPE A

Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control


ESMT 8''SAN 8''SAN 8''SAN 8''SAN 8''SAN 8''SAN 8''SAN EX STM MH RIM = ESMT ESMT 929 INV 48" CONC (N & S)= W W W W W

Klickitat County. On-Site Sewage System. Construction Manual

COLLIER COUNTY Growth Management Department

18"ST 8"W 6"FM OHE T CTV 4"G 8"S RCAP LRCP CMP RCP PVC VCP DIA M.01 W.01-W.02 CROSS SECTIONS - ACCESS ROAD PROTECTION OF VEGETATION

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR

CITY OF ROCKLIN STANDARD DRAWINGS

QUESTIONS & ANSWERS ITB HELEN MCCALL PARK IMPROVEMENTS

McDONALD'S WILSON, NC

GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW

CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT

Site Plan & Design Review Checklist

Site Plan and Design Review Checklist

BARTOW COUNTY RESIDENTIAL DRAINAGE PLAN or RDP

CONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOLLOWING INSTALLATION OF PIPELINES, UTILITIES, AND ASSOCIATED STRUCTURES

CHAPTER 3. Grading Standards

Table Related Arlington County Standards, Specification and Policies

SECTION MEASUREMENT AND PAYMENT

Housing Authority of Utah County

Beaumont Lot Grading Guidelines

Manual for Erosion and Sediment Control Updates

CHAPTER 12 INSTALLATION OF UTILITIES AND OTHER SYSTEMS TABLE OF CONTENTS

SECTION CONSTRUCTION SERVICES

Engineering Division 701 Laurel Street Menlo Park, CA Phone: (650) Fax: (650)

ZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance

CONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOR UNDERGROUND UTILITIES

AMERA COURT RESIDENTIAL SUBDIVISION

Stormwater Erosion Control & Post-Construction Plans (Stormwater Quality Plans)

COMMUNITY PLAZA WAY ASPHALT PAVEMENT OVERLAY ADDENDUM NO.1 UPPER SKAGIT INDIAN TRIBE PAGE 1

LOT GRADING GUIDELINES FOR LOW DENSITY RESIDENTIAL PROPERTIES

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

SECTION 903 EROSION CONTROL

PROPOSED SEGMENTAL RETAINING WALLS ARGONAUT RETAIL VILLAGE - PHASE I PENSACOLA, FLORIDA

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS

SECTION TRENCHING

Transcription:

GENERAL CONSTRUCTION NOTES PAVING AND GRADING NOTES: UTILITY NOTES PROPOSED LEGEND 66.50 66.50 GROUND SPOT ELEVATION GROUND SPOT ELEVATION (MATCH EXISTING GRADE) MATCH EXISTING GRADE MITERED END SECTION (MES) AND STORM PIPE CENTERLINE APPROX. FILL LIMIT APPROX. CUT LIMIT SETBACK LINE WM SAN WATER MAIN SANITARY SEWER SEPTIC TANK & DRAIN FIELD W WATER WELL CRUSHED LIMEROCK LIMITS CONCRETE CONCRETE SLAB ON GRADE BUILDING TREE PROTECTION NOTES SECTION IDENTIFICATION SHEET NUMBER DETAIL IDENTIFICATION SHEET NUMBER EROSION & POLLUTION CONTROL NOTES CLEARING AND PREPARATION NOTES: F.F. EL. R.O.W., R/W F&I MATCH/MEET EXISTING GRADE FINISHED FLOOR ELEVATION FURNISH AND INSTALL

TREE TABLE TOPOGRAPHIC SURVEY OF BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD EXISTING TREE LEGEND SURVEYOR'S REPORT 1. The survey date is August 12, 2015 (last date of fieldwork). 2. This is a Topographic Survey as defined by Chapter 5J-17.050(10)(k) of the Florida Administrative Code. 3. This Topographic Survey map and report or the copies thereof are not valid without the signature and the original raised seal of a Florida licensed surveyor and mapper. 4. Additions or deletions to Survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 5. Copyright 2015 by MacSurvey, Inc. 6. The bearings shown upon this Survey are based on Grid North as established by the National Ocean Service ("NOS") through its program office National Geodetic Survey ("NGS") and the bearing between NGS control point "FLGPS33 1989" and NGS control point "FLGPS33 AZMK 1989" being N47 35'57"W. 7. Elevations shown heron are referenced to the North American Vertical Datum of 1988 (NAVD88) as established by a NGS benchmark being a stainless steel rod in a NGS access cover stamped "FLGPS33 1989" with an elevation of.60'. 8. The coordinate system utilized hereon is relative to the Florida State Plane Coordinate System, West Zone, North American Datum of 1983, 2011 adjustment as established using the control points described in Note #6 and conventional field survey methods. All distances shown hereon are in US Survey Feet (grid). 9. Aerial imagery shown heron was provided by the Florida Department of Environmental Protection ("FDEP") and is shown for informational purposes. The imagery was flown in 2014. 10. Field work performed by Columbia America, licensed Florida Surveying and Mapping Business #79, last date in the field 8/12/2015. 11. The features on this survey that were intended to be topographically mapped include existing topography and existing improvements within the project limits provided by the Florida Forest Service. 12. The scale of this Survey may have changed due to reproduction. SURVEY PROVIDED BY: MacSurvey, Inc. 13. Wetland lines determined by

BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD 37.1' 85.4' 48.4' 49.0' 86.0' 37.0' R40.0' R20.0' R20.0' R40.0' 29.2' F.F. EL.=.50 BLDG ADMIN. R36.0' R3.0' R1 39.1' 38.9' PROPOSED CONCRETE 87.2' PROPOSED SWALE 6" DEEP 4' WIDE AT INLET PROPOSED CONCRETE 99.2' PROPOSED RIP RAP CONCRETE FLUME CONCRETE WEIR (SEE DETAIL ON THIS SHEET) SKIMMER 42.7' PROPOSED POND TOP OF BANK = 65.5 BOTTOM = 63.5 20.0' 37.5' 5'x5'x4" CONCRETE SLAB 66.0' 20.0' 9.2' 93.0' PROPOSED REGULAR PARKING SPACE 103.8' (PROPOSED LIME ROCK) 12.0' 12.0' 26.0' 24.9' 18.0' 9.0' R 93.0' R17.0' R R2 PROPOSED FIRE SUPPRESSION TANK WITH SIAMESE FDC CONNECTION 18.0' PROPERTY SITE INFO: DRAIN FIELD SEPTIC TANK 5'x5'x4" CONCRETE SLAB 30.0' 12.0' R AREA 47,7 S.F. 1.10 AC. PROPOSED IMPERVIOUS ADMIN BUILDING 1,917 SF. 0.04 AC. POLE BARN BUILDING 6,480 SF. 0.15 AC. LIME ROCK 13,223 SF. 0.30 AC. CONCRETE 777 SF. 0.02 AC. TOTAL 22,397 SF. 0.51 AC. PARKING (10) 18'x9' REGULAR PARKING SPACES PROVIDED (1) 18'x12' HANDICAP PARKING SPACE PROVIDED SITE INFO: DRAINAGE DATA: IMPERVIOUS AREA: TREATMENT VOLUME (T.V.) = 1" x IMPERVIOUS AREA T.V. = 1,866 C.F. REQUIRED 22,397 S.F. POND BOTTOM AREA 854 S.F. DESIGN HIGH WATER AREA 1,9 S.F. TOP OF BANK AREA 2,058 S.F. 4'x4'x4" CONCRETE SLAB FOR A/C UNIT GRAVITY SANITARY SEWER SERVICE PROPOSED FENCE LINE PROPOSED 5' WIDE CONCRETE SIDEWALK PROPOSED CONCRETE HANDICAP PARKING SPACE 5'x5'x4" CONCRETE SLAB 5'x5'x4" CONCRETE SLAB.0' STORAGE RANGER F.F. EL.=.50 50'x' BAY 20'x' BAY (OPEN) 13.7' W WATER WELL AREA 11,7 S.F. 0.27 AC. PROPOSED IMPERVIOUS CONCRETE 2,891 SF. 0.07 AC. VOLUME PROVIDED 1,930 S.F. 4'x3'x4" CONCRETE SLAB FOR A/C UNIT.0' 20.0' 20.0' PROPOSED LIME ROCK 40.0' 5'x5'x4" CONCRETE SLAB POTABLE WATER SERVICE

I H 20'x' BAY (OPEN) 20.0' 4.0' BOTTOM 3.3' 3.3' BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX #273 RE-GRADE TOP AND TOP OF DITCH PER FDOT 64 LF OF 14"x23" ERCP INDEX #273 & #515 (TYP. AT ALL MES) 65.40 66.00 66.76 A RE-GRADE TOP OF DITCH DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX #273 64 LF OF 14"x23" ERCP 64 LF OF 14"x23" ERCP.63.16 66.38 66.95 RE-GRADE TOE OF DITCH.85.90.53 E DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX #273 66.50 66.82.01.07.13.25 10.0'. 10.0' 6" DEEP SWALE (4' WIDE BOTTOM).87.21 D..00.25.37.49.05 DOUBLE SIDE DRAIN MITERED END SECTION INV.=M.E.G PER FDOT INDEX #273 STORM STRUCTURE AND PIPE TABLE S-01 MITERED END SECTION INV. =63.5 (PER FDOT INDEX #273) S-02 TYPE C DITCH BOTTOM INLET WITH TRAVERSABLE SLOT RIM EL. =.40 SLOT INV. =66. INV. =64.2 (PER FDOT INDEX #232) S-03 TYPE C DITCH BOTTOM INLET WITH TRAVERSABLE SLOT RIM EL. =.00 SLOT INV. =.42 INV. =64.58 (PER FDOT INDEX #232) P-01 P-02 LF OF 12" RCP @ 1.0% SLOPE 38 LF OF 12" RCP @ 1.0% SLOPE () CONCRETE FLUME CONCRETE WEIR (SEE DETAIL ON THIS SHEET) SKIMMER APPROX. LIMITS OF FILL FLAT BERM PROPOSED POND TOP OF BANK = 65.5 BOTTOM = 63.5 42.7' S-01 64 LF OF 14"x23" ERCP.5 DRAIN FIELD.5 C F G MIN. 10.7' P-01 S-02.43 F.F. EL.=.50 BLDG ADMIN..55 30.0' CANTILEVER GATE PER FDOT INDEX 803.48.26.40.82 S-03 P-02.60..93.25.36.37.16.66.50.55.50.50.47.31.16.29.41.34.83.38 B.59.53.65.50.50..79.60..91 30.0' CANTILEVER GATE PER FDOTINDEX 803 APPROX. LIMITS OF CUT 5' PROPERTY SITE INFO: AREA 47,7 S.F. 1.10 AC. PROPOSED IMPERVIOUS ADMIN BUILDING 1,917 SF. 0.04 AC. POLE BARN BUILDING 6,480 SF. 0.15 AC. LIME ROCK 13,223 SF. 0.30 AC. CONCRETE 777 SF. 0.02 AC. TOTAL 22,397 SF. 0.51 AC. DRAINAGE DATA: IMPERVIOUS AREA: APPROX. LIMITS OF FILL ROOT PRUNE AS NECESSARY 22,397 S.F..90.20 APPROX. LIMITS OF FILL J STORAGE F.F. EL.=.50 50'x' BAY PARKING (10) 18'x9' REGULAR PARKING SPACES PROVIDED (1) 18'x12' HANDICAP PARKING SPACE PROVIDED SITE INFO: AREA 11,7 S.F. 0.27 AC. TREATMENT VOLUME (T.V.) = 1" x IMPERVIOUS AREA T.V. = 1,866 C.F. REQUIRED POND BOTTOM AREA 854 S.F. DESIGN HIGH WATER AREA 1,9 S.F. TOP OF BANK AREA 2,058 S.F. VOLUME PROVIDED 1,930 S.F. PROPOSED 1,086 LF OF TYPE A FENCE PER FDOT INDEX 801 (WOVEN WIRE FABRIC WITH TIMBER POSTS) RANGER. PROPOSED IMPERVIOUS CONCRETE 2,891 SF. 0.07 AC. 5' LIMITS. APPROX. LIMITS OF CUT

BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD PROPOSED 400 SF DRAINAGE FIELD PROPOSED EL.=.5 F&I: 1" 45 BEND 239.2' F&I: 1" 45 BEND 15.2' BERM 10.0'.5 F.F. EL.=.50 BLDG ADMIN. PROPOSED INV.=65.90 WATER MAIN SHALL BE 48" MIN. DEPTH OF COVER WITHIN VEHICULAR AREA 10.0' MIN. F&I: 1" 45 BEND 48.7' F&I: FIRE SUPPRESSION TANK WITH SIAMESE FDC CONNECTION.5 F&I: 89 LF OF 4" PVC WATER MAIN 103.0' ROOT PRUNE 40.0' PROPOSED CLEAN OUT INV.=65.58 PROPOSED CLEAN OUTS INV.=65.82 PROPOSED CLEAN OUT INV.=66.60 F&I: 186 LF OF 4" PVC SANITARY PIPE AT 1.0% SLOPE 10.0' MIN. STORAGE SEE DETAIL "A-A" F&I: 117 LF OF 1" PVC WATER MAIN F.F. EL.=.50 50'x' BAY F&I: 1.5" 90 BEND 20'x' BAY (OPEN) F&I: 4"x2" TEE 2"x1.5" REDUCER 1.5" WATER MAIN VALVE F&I: 1" 90 BEND 1" END CAP PROPOSED CLEAN OUT INV.=66.84 RANGER W PROPOSED CLEAN OUT INV.=66.06 PROPOSED CLEAN OUT INV.=66.26 PROPOSED CLEAN OUT INV.=.28 PROPOSED INV.=.36 PROPOSED WATER WELL CONCRETE PADS EL.=.5 (SEE ELECTRICAL PLANS FOR POWER SUPPLY) NOTE: 1. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY FOR NEAREST ELECTRICAL CONNECTION. F&I: 1.5" 90 BEND F&I: 213 LF OF 1.5" PVC WATER MAIN F&I: 1.5" 90 BEND F&I: 1" 45 BEND F&I: 1" 45 BEND F&I: 1.5"x1" REDUCER F&I: 1.5"x1" TEE F&I: 1" BALL VALVE DETAIL "A-A" SCALE: 1"=10' RANGER F&I: 1" TEMP. CAP

BENCMARK #2 BENCHMARK #1 NE 40TH AVENUE ROAD F.F. EL.=.50 BLDG ADMIN. LANDSCAPE LEGEND SYMBOL TYPE TOTAL MIN. HEIGHT SPACING TREE 4 8' AS SHOWN HEDGE 17 3' 20' O.C. SHRUB Aprox. 75 N/A 3' O.C..5.5 WM WM WM WM WM WM WM WM STORAGE RANGER F.F. EL.=.50 50'x' BAY 20'x' BAY (OPEN) WM WM WM WM WM WM WM W WM WM WM WM WM WM AREA OF SOD NOTES: 1. ALL PLANT MATERIALS ARE TO BE MINIMUM OF FLORIDA NO. ONE AS DEFINED IN GRADES AND STANDARDS REVISED, PART II, AS PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 2. ALL LANDSCAPING SHALL BE MAINTAINED PER THE STANDARDS OF ULDC 21-9.H. 3. GRASS AREAS SHALL BE SODDED. SOD PROVIDED MUST BE VIABLE, REASONABLY FREE OF WEEDS AND CAPABLE OF GROWTH AND DEVELOPMENT. IN GENERAL, SOD STRIPS SHALL BE ALIGNED WITH TIGHTLY FITTED, STAGGERED JOINTS AND NO OVERLAP OF BUTTS OR SIDES. SUBGRADE OF LAWN AREA AFTER FINISHED GRADING SHALL BE REASONABLY FREE OF STONES, STICKS, ROOTS, AND OTHER MATTER PRIOR TO THE PLACEMENT OF SOD. NEW LAWNS SHALL BE WATERED IMMEDIATELY AFTER PLANTING AND SHALL BE MAINTAINED IN A LIVING CONDITION. 4. MULCH, INCLUDING SYNTHETIC GROUND COVER, SUCH AS DECORATIVE STONE, MAY ONLY BE USED AROUND TREES AND LANDSCAPED AREAS AND MAY NOT BE USED IN LIEU OF SOD FOR LAWN AREAS. 5. ALL TREES BEING PLANTED SHALL BE 8' IN HEIGHT AT PLANTING PER ULDC 21-10.A(2).

30.0' ADMIN. BLDG. 16.9' 5.8' 5.8' 5.7' 15.7' 3.7% 66 66 65 65 2.4% 0% 64 64 A 2.8' 3.0% PROP. (2) 14"x23" ERCP 66 66 B 3.0% 0% PROP. (2) 14"x23" ERCP 2.6% 4.2% 2% 66 66 65 65 C 2% S-02 VARIES 1.0% VARIES 74 74 73 73 D 1.0% 4.0' SWALE BOTTOM MIN. 34.2' 12.2' 66 66 MES 32.8' 1.7% SLOPE 6.5' MES 65 65 64 64 PROP. (2) 14"x23" ERCP 63 63 MES 0.5% PROP. (2) 14"x23" ERCP SLOPE MES 2% 30.0' ADMIN. BLDG. 66 66 65 65 2% VARIES ( MAX.) 1.0% 66 25' SETBACK LINE 2% 61.2' ADMIN. BLDG. 65 65 66 62 62 E 64 64 F 64 64 G 76 75 73.0' POLE BARN 50.0' 93.0' TO 74 74 26.0' DRIVE AISLE VARIES SETBACK LINE (SLOPE TO R.O.W.) SWALE 6" 2 4.0' 76 75 75 73 2.0' MIN. 76 74.0' POLE BARN 93.0' TO 73 73 26.0'.0' DRIVE AISLE 18.0' PARKING SPACE VARIES (SLOPE TO R.O.W.) SETBACK LINE SWALE 6" 2 76 75 74 2.0' MIN. 75 74 73 90.0' POLE BARN 75 74 73 4.0' H I J