A Solar Wall System Utilized in Rural Houses of Northeast China

Similar documents
Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Simulation and Energy Analysis of Thermal Environment of Unassisted Passive Solar House

Chapter 7. Passive Solar Contents

Study on the design of high thermal efficiency gas stove based on waste heat recovery

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

Optimal design for a dual-airflow window for different climate regions in China

Feasibility study of a roof top Solar room heater

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Experimental investigation on a ceiling capillary radiant heating system

RETRACTED ARTICLE. Energy Saving Measures and Strengthening Thermal Insulation Construction Technology in Residential Building Design.

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

Energy performance of a ventilation system for an apartment according to the Italian regulation

Commissioning of a Coupled Earth Tube and Natural Ventilation System at the Post-Acceptance Step

Energy Conservation Measure in RDP House in South Africa Overen O. Kelvin, Edson L. Meyer Abstract. Introduction Methodology

Effect of insulation ground on anti-condensation in rural residence

Thermal Characteristics of a Vernacular Building Envelope

Field measurements of performance of roof solar collector

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

A survey on energy consumption status and characteristics of hotel buildings in Guangzhou

Sustainable Building Façade and Advanced Fenestration Systems

Solar Flat Plate Thermal Collector

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

ENERGY SAVING INNOVATION IN CHINESE TRADITIONAL BUILDINGS. L. Zhu Nanjing University of Technology China

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

3C.1 Passive Solar Design National Sustainable Building Advisor Program

The Economic Benefits Analysis on Rural Energy-Saving Housing of Northern China-A Case Study of Woniuhe New Rural Construction, Zhalantun City, China

Monitoring of Advanced Facades and Environmental Systems

Effects of external window form on residential building energy consumption

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

The Study on Green Energy-saving Buildings Design. Li Weifang

Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant. Heating System 1

Chapter 14 Indoor Air Quality

Shading effects on the winter thermal performance of the Trombe wall air gap: An experimental study in Dalian

CAE 331/513 Building Science Fall 2017

Research Article Sensitive Analysis for the Efficiency of a Parabolic Trough Solar Collector Based on Orthogonal Experiment

Influence of Shelves on Air Temperature and Velocity in a Supermarket

Introduction and utilizing of natural energy in Net ZEB practice

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

The Influence of Operation Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

Application Study on Combined Ventilation System of Improving IAQ

Advances in Engineering Research, volume 103 Proceedings of the 3rd International Conference on Material Engineering and Application (ICMEA 2016)

171: An urban office designed for the southern Brazilian climate

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

Analysis of the Window Side Thermal Environment Formed by Air Barrier. Technique in Winter Conditions and Its Economy

Analysis of Uniformity and Energy Consumption in. Supermarket installed DurkeeSox Air Dispersion System. with PE Air Dispersion Model

Numerical Simulation of Airflow Organization and Temperature Distribution in Bulk Curing Barn Yong-qiao WANG, Yan-qiong LI, Yan ZHAO

Experimental Performance Analyses of a Heat Recovery System for Mechanical Ventilation in Buildings

Research on single hole heat transfer power of ground source heat pump system

Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment

Report On Task 57, Subtask B1: Development of Accelerated Ageing Tests for Evacuated Tube Collectors

Technical Feasibility Study of Hybrid Ventilation for a High-rise Office Building in Shanghai

Study on Water-Cooled Solar Semiconductor Air Conditioner

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

An approach for energy conscious renovation of residential buildings in Istanbul by Trombe wall system

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

EFFECTS OF WEATHERS AND INDOOR TEMPERATURES ON PERFORMANCE OF ENERGY RECOVERY VENTILATOR. Yanping Zhou, Jingyi Wu, Ruzhu Wang

ENERGY SIMULATION AND ANALYSIS OF AN INTERMITTENT VENTILATION SYSTEM UNDER TWO CLIMATES

Solar Nova Scotia CANADIAN SOLAR HOME DESIGN MANUAL. for anyone wanting more than a suntan!

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

*Corresponding authors. Tel.: x415, address: (N. Zhu)

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

NORTH PROJECT AQABA, JORDAN. Recommended Energy Efficiency and Renewable Energy Measures for the Premium Villa

Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

For all those with the ability to influence the design, layout or indoor air quality of buildings

Where,h(t)the indicial response of thermal flow rate, B 0 the

The 3-D Numerical Simulation of a Walking Beam Type Slab Heating Furnace with Regenerative Burners

The research and simulation on passive solar house with the attached. sunspace in Beijing

Numerical Investigation of the Air Flow in a Novel PV-Trombe Wall Based on CFD Method

Solar Power. Technical Aspects and Environmental Impacts. 6 th March 2011 Sustainable Energy Options (UAU212F) - University of Iceland

proposal for a mini solar chimney with venturi to multiply air flow velocity and to generate electricity from solar energy with high efficiency

Effect of Building Orientation and Window Glazing on the Energy Consumption of HVAC System of an Office Building for Different Climate Zones

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

Xiaofen Xu, Liang Zhang, Huajing Sha, Ying Ji, Peng Xu. Tongji University, Shanghai, China

A Field Study of Thermal Comfort in Open-plan Office Buildings during Transition Seasons in Harbin. Yunsong Han 1, 2, Huixuan Sun 1, 2, Cheng Sun 1, 2

AREN 3050 ENVIRONMENTAL SYSTEMS FOR BUILDINGS I FALL 2005

THE EFFECTS OF INDOOR ENVIRONMENT IN SUPERMARKET ON CLIENTS' AND OPERATORS' SATISFACTION

COMPARATIVE STUDIES ON THERMAL EFFICIENCY OF SINGLE AND DOUBLE GLAZED FLAT PLATE SOLAR WATER HEATER

A preliminary study on the climate adaptive design of green rural houses in west China

ScienceDirect. Thermal performance of a quartz tube solid particle air receiver

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

ENERGY SAVING IN BUILDING USING PCM IN WINDOWS

Consumer Energy Tax Credit

Performance Study of Solar Air Heater with Baffled Duct

Radical POTENTIAL!! COMFORT ZONE WHAT IS IT? WHAT DOES IT HAVE TO DO WITH GREEN BUILDING + ZERO CARBON?

SIMULATION OF THE PERFORMANCE OF A HYBRID VENTILATION SYSTEM IN DIFFERENT CLIMATES. Technicka 2896/2, Brno, Czech Republic

NUMERICAL SIMULATIONS OF THE NATURAL VENTILATION DESIGN MIX OF ELEMENTARY SCHOOL CLASSROOMS

Modeling Energy Consumption Effects of Glazing

10 green building innovations in India

Energy impact of ASHRAE s museum climate classes: a simulation study on four museums with different quality of envelopes

Performance Improvement Analysis for a Negative-pressurized Biosafety Level Laboratory

FULL YEAR PERFORMANCE SIMULATION OF A DIRECT-COOLED THERMAL STORAGE ROOF (DCTSR) IN THE MIDWEST

Thermal Performance Simulation of Residential Building in Tropical Climate Case Study: Housing in Bandar Universiti, Malaysia

Thermal Performance of Solar Heating System with Water Floor

Transcription:

A Solar Wall System Utilized in Rural Houses of Northeast China Tiantian Zhang and Yufei Tan in rural buildings, for instance, only 16.4% of the investigated houses employ solar energy to produce hot water [4]. Moreover, there is always a contradiction between the heating and ventilation in a rural house in winter. Since the outdoor air temperature is extremely low, if there is an increase in the amount of ventilation, the room air temperature will decrease, thus the heating demand of the room space will increase accordingly [5]. Resolving this conflict becomes a major problem in improving the indoor thermal comfort and air quality. This paper proposes a solar wall system for rural buildings in cold regions for the purpose of increasing the indoor air temperature as well as improving the indoor air quality. Firstly, the structure and the operation modes of the system are introduced in detail. Then the methods of testing and instrument are detailed. Based on the test, the heating capacity of the solar wall system has been evaluated by investigating the temperature distributions of the solar walls and indoor spaces. Finally, the influence of the system on indoor air quality is analyzed by contrasting the pollutant concentrations of different operation modes of the system. Abstract Resolving the conflict between the heating and ventilation in a rural house in winter becomes a major problem in improving the indoor thermal comfort and air quality. This paper proposes a solar wall system for rural buildings in cold regions for the purpose of increasing the indoor air temperature as well as improving the indoor air quality. Firstly, the structure and the operation modes of the system are introduced in detail. Then the methods of testing and instrument are detailed. Based on the test, the heating capacity of the solar wall system has been evaluated by investigating the temperature distributions of the solar walls and indoor spaces. Finally, the influence of the system on indoor air quality is analyzed by contrasting the pollutant concentrations of different operation modes of the system. Index Terms Solar wall system, thermal comfort, indoor air quality, experimental test. I. INTRODUCTION For rural buildings in severe cold area of China, the long heating period, the low levels of design and construction technology, and the poor energy resource structure, may lead to significant energy consumption in winter [1]. The energy consumption in buildings is becoming increasingly higher, especially in winter when there are both heating and cooking requirements in a rural residential house. However, though the energy input increases, the thermal comfort level and indoor air quality vary little compared with before [2]. On account of poor insulating properties of the envelops and low efficiencies of the heating systems, the indoor air temperature can only be maintained in a range from 5 oc to 15 oc, on the premise that the energy used for space heating takes up 40 % of the total energy consumption in rural residential buildings [3]. Conventional heating measures, such as Chinese kang, heating stove and indigenous radiator heating system, still play a dominant role in rural building heating field. Most of the energy-using facilities, both heating and kitchen, are mainly reliant on fuel woods, crop stalks or coal, burnt in open fires or stoves to produce heat energy. The energy utilization efficiencies of these systems are only 8-10%. Usually, the indoor pollutants, such as CO, CO2, particulate matter, NOx and SO2, are always far above standard values. Besides, new energy and sustainable energy are rarely utilized II. THE TEST BUILDING AND THE SOLAR WALL SYSTEM The solar wall house is a single-stand building which is seated in north but facing the south. The internal area is 74.5 m2, and the height is 3m. The external length in the east-west direction is 12m, and the width in the north-south direction is 8m. There are 4 rooms, including 2 bedrooms, a kitchen and a sitting room. The external wall is made of solid bricks with a cavity insulating layer and two plaster layers (the total thickness is 500mm: 20mm internal plaster layer, 240mm brick wall layer, 100mm insulation layer, 120mm brick layer, and 20mm external plaster layer). The external windows are all double-glazing windows with the sizes of 2.2m 1.8m. Polystyrene board insulation layers with different thicknesses are added to the roof and ground of the house (for the roof, the thickness of the polystyrene board is 100mm, and for ground is 50mm). The bedrooms are placed in the south side, and each bedroom is equipped with a Chinese kang for space heating (see Fig. 1). The solar wall is a glazed transpired collector (GTC) type located on the external surface of the whole south wall with the length of 12m and the height of 2.9m (see Fig. 2). Except for the window areas, the total area of the black metal plate (also named solar energy collector) is about 18m2. The solar wall system provides hot air for the south bedrooms. The glass-cover of the solar wall reduces the energy exchange between the solar wall and outdoor air by weakening the Manuscript received July 9, 2015; revised September 21, 2015. This work was financially supported by a grant from the National Key Technologies R & D Program of China during the 12th Five-Year Plan Period (No. 2011BAJ08B07). Tiantian Zhang and Yufei Tan are with the Harbin Institute of Technology, Harbin, China (e-mail: x418298537@163.com, tanyufei2002@163.com). doi: 10.18178/jocet.2016.4.5.307 330

natural convection and radiation heat transfer. Three fresh air inlets (the sizes are 20cm 8cm) are placed at the bottom of the cavity. An air supply outlet (20cm 20cm) is placed on the ceiling of each bedroom. A return air inlet (20cm 20cm) is also placed on the external wall of each bedroom. The hot air from the solar wall cavity is distributed to the bedrooms by circular ducts with the diameter of 100mm. The power source of the air flow is provided by an air fan located in each bedroom. Fig. 1. The appearance of the solar wall house. Fig. 2. System schematic of the solar wall system. The transpired absorber plate is constructed from metal plate with uniform-distributed holes, which is perforated and covered with selective coating. Each of the uniform-distributed holes on the absorber plate has a diameter of 1 2mm. The transpired absorber plate is mounted out 150 mm from the back plate, and the distance between the absorber plate and the glazing is 150 mm [6]. Fan draws the outdoor air, or the recirculated air (indoor air), or the mixture of them into the cavity between the glazing and the absorber plate, and then through the transpired absorber plate into the cavity between the transpired absorber plate and the back plate, and at last into the space that need to be heated through air duct. With the promotion of the solar energy absorbed by the metal plate, air is heated when it is drawn through the small holes on the absorber plate. At nighttime, the air inlet and the fan are closed to form an enclosed cavity in the solar wall structure. The heat loss of the external wall is absorbed by the internal air of the enclosed cavity, which offers an air insulation layer for the external envelops. In summer, the outer cavityis opened, the transpired absorber plate absorbs the solar energy instead of the external walls in a common envelop system, and heats the internal air of the cavity. The air moves from the bottom to the top of the cavity which generates an air exchange between the cavity and the out ambient under the buoyancy results from the temperature difference of the internal air and ambient air. The heat gain of the solar wall system is released to the ambient by the air movement, thus a heating insulation effect is achieved. Four running modes can be achieved in winter by the solar wall system [7]: Full fresh air mode: In this mode, one or more fresh air inlets are opened, while all return air inlets in the bedrooms are closed. The outdoor air is sent into the indoor space after being heated by the transpired absorber plate. The ventilation effect is the biggest in this mode. Mixture mode: According to different ventilation demands, one or more fresh air inlets are opened, while corresponding return air inlet in the bedrooms is also opened. The mixture of the fresh air and return air is sent into the indoor space after being heated. The drive force is the combination of the buoyancy and air fans. Full return air mode: When the indoor air quality satisfies daily life demands, all fresh air inlets are closed, while all return air inlets are opened. The recalculated return air is sent back to the room space after being heated. In this mode, the heating effect is the biggest. Off mode: All air inlet and outlets are closed to form an enclosed cavity in the solar wall structure. The air gap in the enclosed system is served as an air insulation layer for the external envelops. In summer, the running method of the system is totally different. All return air inlets and all air fans are closed, while all the fresh air inlets and the outlets at the top of cavity 1 are opened. The air exchanges between the internal cavity and the outdoor. In this mode, the heat gain of the external wall in summer daytime can be reduced, thus the indoor air temperature is decreased. During the test period in winter, there was one Chinese kang in each of the bedroom. The sizes of the kang are 4.6m in length, 2.1m in width, and 0.6m in height. The total surface heating area is about 9.66m2. The Chinese kangs are the main heating facilities in the house, while the solar wall is served as a supplement heating system and the main ventilation facility. III. TEST PURPOSE AND MEASURING INSTRUMENTS The performance tests consist of thermal performance test of the solar wall and the indoor air quality test. Based on the tests, the heating effectiveness of the solar wall hot-air system 331

and the improvement on indoor air quality can be investigated. The testing parameters of the solar wall system includes: solar radiation intensity, outdoor air temperature, supply air temperature, return air temperature, air velocities at refresh air inlet, return air inlet and air supply outlet; the indoor air items includes the concentrations of carbon dioxide (CO2), carbon monoxide (CO) and inhalable particulate matters (PM2.5 and PM10). The measuring instruments needed in the tests are listed in Table I. it is the main activity space of the residents. That s the reason why the internal air temperature at point 1 is higher than that of the test point 2. The difference is about 2 oc as shown in the above figure. B. The Supply Air Temperature and the Heat Capacity of Different Running Modes The supply air temperatures under different running modes of the solar wall system tested on Feb. 2nd is presented in Table II. Based on the measured data and extra air velocity data, the heating capacity of the system under different running modes can be obtained according to the following equation: TABLE I: TEST INSTRUMENTS Test items Indoor and outdoor temperatures Concentrations of PM2.5, PM10, CO, CO2 Thermal performance of building envelops Surface temperatures of the solar wall Surface heat flux Sizes of the building Test instruments Temperature and humidity data collector 2 P Gs,i (Ts,i Tw/ n ) C Indoor air quality monitor (Precision:±3.0%, resolution:1ppm) FLUKE thermal infrared imager(operating temperature:-20~250 oc; sensitivity <0.1 o C) i 1 copper-constantan thermocouples Heat flux sensor laser range finder The tests on the four running modes of the solar wall system were processed on Feb. 2nd, 2015. The full return air mode was tested from 10:30 AM to11:30 AM; the full fresh air mode was tested from 11:30 AM to13:00 PM; the off mode was tested from 13:30 PM to15:00 PM; the mixture mode was tested from 15:30 PM to16:00 PM. And a continuous test of the solar wall system on the supply air temperature and indoor air temperature was conducted on Feb. 3rd. where P is the heating capacity of the system, W; Gs,i is the air supply volume of room i, kg/s; Ts,i is the supply air temperature of room i, oc; Tw/n is the fresh air temperature or the return air temperature (equals to indoor temperature) or the equivalent temperature of the mixture mode, oc; C is the specific heat of air, 1.03 103J/(kg oc). The calculation results are shown in Table III. The biggest heating capacity appeared in the mixture mode, the value is 12.26kW; the full return air mode has a smaller heating capacity to be 10.37kW; even when the solar wall worked in a full fresh air mode, the heating capacity was still 7.33kW. Thus, the solar wall system has an excellent heating capacity, as the supply air temperature is high and stable, which ensures a thermal stability of the indoor space. TABLE II: SUPPLY AIR TEMPERATURES UNDER DIFFERENT MODES Running mode Supply air temperature 1 Supply air temperature 2 Full return air mode 47.3 oc 45.6 oc o Full fresh air mode 46.3 C 39 oc Mixture mode 43.7 oc 37.8 oc IV. RESULTS AND DISCUSSIONS A. Relationship between Solar Radiation Intensity and Internal Air Temperature The variation curve of the solar radiation intensity and the internal temperature curves are two test points are illustrated in Fig. 3. TABLE III: HEATING CAPACITIES UNDER DIFFERENT RUNNING MODES Heat capacity(w) Room 1 Room 2 Sum Full return air mode 5166.72 5206.19 10372.91 Full fresh air mode 5093.28 2240.11 7333.39 Mixture mode 6176.03 6085.83 12261.86 C. The Supply Air Temperature and the Bedroom Temperatures in a Typical Winter Day Fig. 3. Solar radiation and internal air temperatures of the cavity. Test point 1 was located in the external wall of the master bedroom; while point 2 was positioned at the extra bedroom side. The indoor air temperature of the master bedroom is higher, as the Chinese kang in it was heated twice a day since Fig. 4. Indoor air temperature and supply air temperature in a day. 332

Fig. 4 illustrates the daily changes of the bedroom temperatures and the supply air temperature. Seen from the figure, the master bedroom has a higher air temperature compared with the extra bedroom. The changing tendencies of the room temperatures and the supply air temperature are the same. The highest temperatures occur at 13:00. Using the solar wall system and the Chinese kang, the master room temperature can be maintained at a comfort level. Table IV illustrates the standard values of indoor air pollutants of a heating room according to IAQS2012 (indoor air quality standard). D. Indoor Air Quality Improvement Fig. 5 and Fig. 6 show the test results of indoor contaminant concentrations. In the test, the off mode, the full return air mode, the full fresh air mode and the mixture mode of the solar wall system was tested in turn. Seen from the figures, the concentrations of the indoor inhalable particulate matters are constant with that of the CO, since the pollution sources of these matters are all fuel combustion. When the solar wall converted into the full return air mode, the concentrations of particulate matters didn t change much; but it decreased a lot when the full fresh air mode was switched on; and it continued to decline in the mixture mode. The variation of CO had the similar changing tendency. The only difference was that the CO content had a reduction when the running mode changed from off mode to full return air mode. The CO2 concentration was impacted seriously by the activity of residents. When the mode changed from full return air mode to full fresh air mode, the CO2 content decreased significantly, indicating that the full fresh air mode has a great capacity in ventilation. When the mixture mode was on, the CO2 content grew a little, which implies that the mixture has a weaker ventilation capacity compared with the full fresh air mode. Compare the test values to the standard values, when the Chinese kang works, the CO2 content, the PM2.5 and PM10 contents are all above the standards. When the solar wall system starts to work in a full fresh air mode or a mixture mode, the CO2 content can be reduced below the standard value; and the PM2.5 and PM10 contents can be significantly decreased. Due to the excessive utilization of crop stalks, the particulate matters of outdoor air are also above the standards. Thus the solar wall system could not reduce the indoor particulate matter concentrations to a standard level. The solar wall system solves the conflicts between heating and ventilation in rural residential buildings. TABLE IV: STANDARD VALUES OF INDOOR AIR POLLUTANTS Category CO CO2 PM2.5 PM10 unit [ppm] [ppm] [mg/m3] [mg/m3] standard value 8 1000 0.075 0.15 V. CONCLUSION The solar wall system solves the conflicts between heating and ventilation in rural residential buildings. The implementation of this system not only ensures the indoor air thermal comfort, but also reduces the indoor pollutant concentrations and increases the indoor air quality. Four running modes can be achieved by the solar wall system in winter: The mixture mode has the biggest heating capacity of 12.26kW; the full return air mode has a smaller heating capacity to be 10.37kW; the heating capacity of the full fresh air mode was still 7.33kW. When the solar wall system works in a full fresh air mode or a mixture mode, the CO2 content can be reduced below the standard value; and the PM2.5 and PM10 contents can be significantly decreased. This wall system also improves the insulation performance of the external envelops by reducing the heat loss in south external walls, and thus reducing the heating load of a rural residential house. REFERENCES [1] [2] Fig. 5. Concentrations of PM10 and PM2.5. [3] [4] [5] [6] [7] Fig. 6. Concentrations of CO and CO2 333 C. Liu, Research on indoor air quality at rural residential house in northeast, M.S. thesis, Harbin Engineering University, Heilongjiang Province, China, 2007. R. Sun, J. Lv, and S. Ren, Investigation on energy con-sumption of rural residential housing in northeast area, Building Energy & Environment, vol. 4, pp. 45-48, April 2011. H. Jin, H. Zhao, and X. Wang, Research on the indoor thermal comfort environment of rural housing in winter in super-cold region, Journal of Harbin Institute of Technology, vol, 38, pp. 2108-2111, July 2006. T. Zhang, Y. Tan, & X. Zhang, Current situation of energy and indoor environment in rural buildings of northeast China, Applied Mechanics and Materials, vol, 522-524, pp. 1756-1759, October 2014. K. Naghman, A review on wind driven ventilation tech-niques, Energy and Buildings, vol, 40, pp. 1586-1604, August 2008. L. Gao, H. Bai, and S. Mao, Potential application of glazed transpired collectors to space heating in cold climates, Energy Conversion and Management, vol, 77, pp. 690-699, May 2014. L. Gao, H. Bai, and X. Fang, Experimental study of a building-integrated solar air heating system in cold climate of China, Energy and Buildings, vol. 65, pp. 359-367, February 2013.

Tiantian Zhang was born on December 4, 1987 in Jingzhou, China. He received his bachelor and master s degree in Harbin Institute of Technology. Now he is a Ph.D. student in HIT. His research interests focus on heat transfer, fluid mechanics, thermodynamics, solar energy, HVAC systems, gas supplying, renewable and sustainable energy technologies in buildings. Yufei Tan was born in Harbin, China in 1962. She is now a professor of the School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin, China. Her research interests include heat transfer, fluid mechanics, thermodynamics, building energy efficiency, heating ventilation, air conditioning system simulation, and control. 334