Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

Similar documents
Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: Level 1/Level 2, TOUGHCable Connectors. Increase Performance. Extreme Weather-Proof

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

CABLEMASTER CABLE GUIDE

HELUKABEL CC-Link Certified Cables

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section

HELUKABEL CC-Link Certified Cables

PURENET-U (Part No.: U RXX2, U PXX2)

Cables for Industrial Ethernet copper cables

Data sheet E-DAT C6 24x8(8) 1RU modular LSA Cat.6 patch panel

Detailed Specifications & Technical Data

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

DATA NETWORK TECHNOLOGY

Separator, suitable tape between the braid and outer sheath

Compact Module. Enhanced Category 5 FTP Cabling System

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

TECHNICAL SPECIFICATION

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

YG-B Series. Single Point Load Cell

Company Overview.

SECTION INSULATED WIRE AND CABLE

Data sheet chainflex CFSPECIAL.182

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

Manhattan Thermocouple Cable

Comparison of BS 5308, PAS 5308 and BS EN

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series

THE ESSENTIAL GUIDE TO CHOOSING THE RIGHT ESD BAG

Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

PCCAT5EP CAT5e SFTP Ethernet Patch Cable. PCCAT5EPX2 Dual CAT5e SFTP Figure Eight Cable. PCCAT5EUTPP CAT5e Ultra-Patch UTP Ethernet Cable

Cable Designs. We take pride in being a total support OEM/ODM cable manufacture

SECTION GROUNDING AND BONDING

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

Caledonian Cables Ltd

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Data sheet chainflex CF887


ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew Series

List Price w.e.f. 02nd January, 2018

List Price w.e.f. 24th July, 2018

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

M-FLEX CONTROL CABLES

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

BELDEN COPPER DATA NETWORKING CABLE PLENUM RATED

Wire and Cable SPEC 44 Wire and Cable

SERV-RITE Wire and Cable

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.


Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Engineering Data for Copper and Aluminum Conductor Electrical Cables

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Industry Application Information

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

Construction guideline

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Tele-Fonika Cable Americas

Energy Chain System Training

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

Shipboard and Offshore Cables

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

Excellent Integrated System Limited

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

catalog Copper Wires

Una e mpre sa Vi akab l e GLOSSARY.

REMOTE POWERING TEST RESULTS & MODELING

SENTRAN. Low Profile Load Cell. For more information call

Low Smoke Halogen Free cables

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

*** Supercedes: BECO E and COM , , & ***

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

COMMUNICATIONS CABLING SECTION COMMUNICATIONS CABLING PART 1 - GENERAL

YBSeries. Single Point Load Cell

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CONTENT INTRODUCTION. VISION Introduction & Assortment HDMI interconnects Component interconnects SCART interconnects Antenna Interconnects

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

3M Cold Shrink Joint, SC145-II/SS145-II

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS

Transcription:

1Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support

Datasheet Protect your networks from the most brutal environments with Ubiquiti s industrial-grade shielded Ethernet cable, TOUGHCable. Increase Performance Dramatically improve your Ethernet link states, speeds, and overall performance with Ubiquiti TOUGHCables. Extreme Weatherproof TOUGHCables have been built to perform even in the harshest weather and environments. ESD Damage Protection Protect your networks from devastating electrostatic discharge (ESD) attacks. Extended Cable Support TOUGHCables have been developed to increase power handling performance for extended cable run lengths. TOUGHCable Connectors!"#$%&$'(()*+#,%-.#+*/01*2,#*3%45*67%82%4%*9:6;<='7(#,*'.+*'>'%('7(#*%.***************** 100-pc. bags, TOUGHCable Connectors protect against ESD attacks and Ethernet 5'1+3'1#*+'?'-#*35%(#*'((03%.-*1'"%+*&#(+*+#"(0)?#.4*3%45024*,0(+#1%.-@ Bulletproof your networks TOUGHCable is currently available in two versions: PRO Shielding Protection and CARRIER Shielding Protection. ESD attacks are the leading cause for device failures. The diagram below illustrates the areas vulnerable to ESD attacks in a network. By using a grounded Ubiquiti Power over Ethernet (PoE) Adapter along with Ubiquiti TOUGHCable and TOUGHCable Connectors, you can effectively protect against ESD attacks. TOUGHCable PRO A Category 5e, outdoor, carrier-class shielded cable with an integrated ESD drain wire. TOUGHCable CARRIER A*='4#-01)BC#D*024+001D*$'11%#1E$(',,* shielded cable that features an integrated ESD drain wire, anti-crosstalk divider, and secondary shielding. It is rated to provide optimal performance on Gigabit Ethernet networks. Additional Information: F* 24 AWG copper conductor pairs F* 26 AWG integrated ESD drain wire to prevent ESD attacks and damage F* PE outdoor-rated, weatherproof jacket F* Multi-layered shielding F* Available in lengths of 1000 ft GHIJ@KB?L 2 Unshielded cable with no ESD drain Ubiquiti TOUGHCable PoE adapter with no earth ground Ubiquiti PoE Adapter

Level 1 Shielding Protection Cable Ethernet Support Wire Gauge Diameter Insulation Type Insulation Thickness Insulation Diameter Separation (Polyester Wrapping) Cable Shield (Aluminum Foil) Jacket Material Jacket Thickness Jacket Outer Diameter Jacket Color Reference Standard CAT5e, Shielded Up to 1 Gbps 24 AWG Solid Bare Copper 0.500 ± 0.005 mm Solid PE AVG: 0.26 mm, MIN: 0.25 mm 1.04 ± 0.03 mm Thick: 0.025 mm, Extent: 20 mm None Thick: 0.060 mm, Extent: 18 mm 0.4 CCS Yes PE AVG: 0.50 mm, MIN: 0.46 mm 6.0 ± 0.30 mm Gray ISO/IEC 11801, TIA/EIA568B.2 Datasheet Frequency (MHz) RL min. Attenuation PRO Performance NEXT/PSNEXT ACR ELFEXT/PSELFEXT 1 17.0 2.03 62.30 60.30 60.75 4 18.8 4.04 53.26 49.20 48.71 8 19.7 5.76 48.75 43.00 42.69 10 20.0 6.46 47.30 40.80 40.75 16 20.0 8.24 44.30 36.10 36.67 20 20.0 9.26 42.78 33.50 34.73 25 19.3 10.41 41.33 30.90 32.79 31.25 18.6 11.72 39.87 28.20 30.86 62.5 16.5 16.99 35.36 18.40 24.83 100 15.1 21.97 32.29 10.30 20.75 150 13.80 23.40 18.60/30.30 8.30 17.60/18.50 Insulation Separation Cable Shield Weatherproof Jacket 3

4Datasheet Level 2 Shielding Protection Cable Ethernet Support Wire Gauge Diameter Insulation Type Insulation Thickness Insulation Diameter Separation (Polyester Wrapping) Cable Shield (Aluminum Foil) CAT5e, Shielded Up to 1 Gbps 24 AWG Solid Bare Copper 0.500 ± 0.005 mm Solid PE AVG: 0.295 mm, MIN: 0.29 mm 1.16 ± 0.02 mm Thick: 0.025 mm, Extent: 20 mm LDPE: 4.2*0.3 mm Thick: 0.060 mm, Extent: 20 mm 0.4 TC Secondary Cable Shield (Braid) 16*8*0.16AA Density: 95% Jacket Material Jacket Thickness Jacket Outer Diameter Jacket Color Reference Standard Frequency (MHz) RL min. CARRIER Performance Attenuation NEXT/PSNEXT ACR Yes PE AVG: 0.52 mm, MIN: 0.46 mm 6.8 ± 0.30 mm Gray ISO/IEC 11801, TIA/EIA568B.2 ELFEXT/PSELFEXT 1 18.0 1.93 65.30 60.30 61.00 4 19.9 3.90 56.27 49.20 48.96 8 20.7 5.50 51.75 43.00 42.94 10 21.0 6.30 50.30 40.80 41.00 16 21.0 8.00 47.24 36.10 36.92 20 21.0 9.00 45.78 33.50 34.98 25 20.3 10.20 44.33 30.90 33.04 31.25 19.5 11.50 42.88 28.20 31.10 62.5 19.0 16.70 38.36 18.40 25.08 100 18.3 21.70 35.30 10.30 21.00 200 16.5 32.20 30.78/27.78 7.60 17.78/14.98 Insulation Separation Cable Shield Secondary Cable Shield Weatherproof Jacket

Datasheet TERMS OF USE: The Ubiquiti radio device must be professionally installed. Shielded Ethernet cable and earth grounding must be used as conditions of product warranty. It is the installer s responsibility to follow local country regulations, including operation within legal frequency channels, output power, and Dynamic Frequency Selection (DFS) requirements. For further information, please visit www.ubnt.com. PH032912 2012 Ubiquiti Networks, Inc. All rights reserved. www.ubnt.com 5