Flat Slabs. d 2. A typical flat slab (without drop and column head)

Similar documents
DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Two-way slabs. Flat plate with or without drop panels / capitals

Comparison of One-way and Two-way slab behavior. One-way slabs carry load in one direction. Two-way slabs carry load in two directions.

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

CIVIL ENGINEERING YEAR QUESTION BANK

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

Flexure and Serviceability Limit State

VARIOUS TYPES OF SLABS

DIRECT DESIGN METHOD DDM

UNIT-1 RETAINING WALLS

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07)

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

DESIGN OF RC ELEMENTS UNIT 1 PART-A

CE2401-DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY QUESTION BANK

COLUMNS. Classification of columns:

CE2306 DESIGN OF RC ELEMENTS UNIT II LIMIT STATE DESIGN FOR FLEXTURE Part A (2marks) 1. Explain the check for deflection control in the design of

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

PARAMETRIC STUDY ON FLAT SLAB WITH AND WITHOUT COLUMN DROP

Sabah Shawkat Cabinet of Structural Engineering 2017

13-14 May 2011 B.V.M. Engineering College, V.V.Nagar,Gujarat,India

Questions with Solution

KSK COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING CE 2505-DESIGN OF RC ELEMENTS QUESTION BANK

Comparative seismic performance of Flat slab with peripheral beam provided infill and shear wall panel at different heights

Lecture-06 Analysis and Design of Slab Systems

> 0. 1 f, they are treated as beam-columns.

GATE SOLVED PAPER - CE

Seismic Behaviour of RC Shear Walls

ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR FLAT SLAB FOR MULTISTOREYED BUILDING UNDER TWO SEISMIC ZONES USING ETABS AND SAFE

Level 6 Graduate Diploma in Engineering Structural analysis

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions)

Seismic Performance Of R C Flat-Slab Building Structural Systems

Analysis and Design of One-way Slab System (Part-I)

Types of Foundations

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for

Figure: Grid or Waffle slab

Framed, Two-Way, Conventionally Reinforced, Concrete Flat Slab and Flat Plate Construction and Design

Lecture Retaining Wall Week 12

From Park and Gamble Book.

eight plates and grids Plates, Slabs & Grids Plates, Slabs & Grids Term Project plates horizontal plane, rigid slabs thin, flat, rigid

Slabs and Flat Slabs

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Seismic Detailing of RC Structures (IS: )

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

eight plates and grids APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

twenty two concrete construction: flat spanning systems, columns & frames ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN

Code No: R Set No. 1

REINFORCED CONCRETE STRUCTURE COURSE STR 302A CL0SED BOOK EXAM THIRD YEAR CIVIL FIRST TERM YEAR TYPES OF SLABS

twenty two concrete construction: flat spanning systems, columns & frames Reinforced Concrete Design Reinforced Concrete Design

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

Masonry and Cold-Formed Steel Requirements

SEISMIC PERFORMANCE OF FLAT SLAB WITH DROP AND CONVENTIONAL SLAB STRUCTURE

Steel Design Guide Series. Steel and Composite Beams with. Web Openings

twenty two concrete construction: flat spanning systems, columns & frames Reinforced Concrete Design Reinforced Concrete Design

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Section A A: Slab & Beam Elevation

Strength Design of Reinforced Concrete Structures

This final draft of the fib MC2010 has not been published; it is intended only for the purpose of voting by the General Assembly.

1 Prepared By:Mr.A.Sathiyamoorthy, M.E., AP/Civil

Multideck 146. Contents

IS 1893 and IS Codal Changes

`Limit State of Collapse in Compression Design of an Axially Loaded Short Column

6. Design of Water Tanks (For class held on 23 rd, 24 th, 30 th April 7 th and 8 th May 07)

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

Cork Institute of Technology. Summer 2006 Structural Design & Detailing I (Time: 4 Hours)

Design Criteria For Reinforced Concrete Columns Under Seismic Loading

DESIGN AND DETAILING OF RETAINING WALLS

Analysis, Design and Estimation of Multi Storied Residential Building using ETABS Software

Alternate Design Method- Design Procedure of Two-way Slabs using ACI Moment Coefficients and Approved by BNBC 2013

UNIT IVCOMPOSITE CONSTRUCTION PART A

ANALYSIS AND DESIGN OF FLAT SLABS USING VARIOUS CODES

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

Software Verification

ST7008 PRESTRESSED CONCRETE

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Design for Shear for Prestressed Concrete Beam

1. INTRODUCTION 1.1 FLAT SLAB. 275 P a g e

Recommendations for additional fire protection of structural elements

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

Questions with solution

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 2, 2012

CHAPTER 2. Design Formulae for Bending

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

Example of a modelling review Roof truss

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

Hours / 100 Marks Seat No.

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

Design of Reinforced Concrete Slabs

Section G1. Design of Cast-In-Place Box Conduits

DHANALAKSHMI COLLEGE OF ENGINEERING, CHENNAI DEPARTMENT OF CIVIL ENGINEERING CE6601 DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY STRUCTURES

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

Preliminary design of concrete structures 124SDP1

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

Schöck Isokorb type K-HV, K-BH, K-WO, K-WU

Transcription:

1 CHAPTER Flat Slabs 1.1 INTRDUCTIN Common practice of design and construction is to support the slabs by beams and support the beams by columns. This may be called as beam-slab construction. The beams reduce the available net clear ceiling height. Hence in warehouses, offices and public halls some times beams are avoided and slabs are directly supported by columns. This types of construction is aesthetically appealing also. These slabs which are directly supported by columns are called Flat Slabs. Fig. 1.1 shows a typical flat slab. d Critical section for shear Fig. 1.1 A typical flat slab (without drop and column head) The column head is some times widened so as to reduce the punching shear in the slab. The widened portions are called column heads. The column heads may be provided with any angle from the consideration of architecture but for the design, concrete in the portion at 45º on either side of vertical only is considered as effective for the design [Ref. Fig. 1.]. Critical section for shear d 90 Concrete in this area is neglected for calculation Fig. 1. Slab without drop and column with column head

Advanced R.C.C. Design Moments in the slabs are more near the column. Hence the slab is thickened near the columns by providing the drops as shown in Fig. 1.3. Sometimes the drops are called as capital of the column. Thus we have the following types of flat slabs: d d Critical section for shear Critical section for shear Fig. 1.3 Slab with drop and column without column head (i) Slabs without drop and column head (Fig. 1.1). (ii) Slabs without drop and column with column head (Fig. 1.). (iii) Slabs with drop and column without column head (Fig. 1.3). (iv) Slabs with drop and column head as shown in Fig. 1.4. d Critical section for shear 45 45 Fig. 1.4 Slab with drop and column with column head The portion of flat slab that is bound on each of its four sides by centre lines of adjacent columns is called a panel. The panel shown in Fig. 1.5 has size 1. A panel may be divided into column strips and middle strips. Column Strip means a design strip having a width of 0.5 1 or 0.5, whichever is less. The remaining middle portion which is bound by the column strips is called middle strip. Fig. 1.5 shows the division of flat slab panel into column and middle strips in the direction y.

Flat Slabs 3 a C of panel A b C of panel B 1 y o Column strip x Fig. 1.5 Middle strip Column strip a b 4 4 but 1 but 4 1 4 Middle strip Column strip Panels, column strips and middle strips is y-direction 1. PRPRTINING F FAT SABS IS 456-000 [Clause 31.] gives the following guidelines for proportioning. 1..1 Drops The drops when provided shall be rectangular in plan, and have a length in each direction not less than one third of the panel in that direction. For exterior panels, the width of drops at right angles to the non continuous edge and measured from the centre-line of the columns shall be equal to one half of the width of drop for interior panels. 1.. Column Heads Where column heads are provided, that portion of the column head which lies within the largest right circular cone or pyramid entirely within the outlines of the column and the column head, shall be considered for design purpose as shown in Figs. 1. and 1.4. 1..3 Thickness of Flat Slab From the consideration of deflection control IS 456-000 specifies minimum thickness in terms of span to effective depth ratio. For this purpose larger span is to be considered. If drop as specified in 1..1 is provided, then the maximum value of ratio of larger span to thickness shall be = 40, if mild steel is used = 3, if Fe 415 or Fe 500 steel is used If drops are not provided or size of drops do not satisfy the specification 1..1, then the ratio shall not exceed 0.9 times the value specified above i.e., = 40 0.9 = 36, if mild steel is used. = 3 0.9 =., if HYSD bars are used It is also specified that in no case, the thickness of flat slab shall be less than 15 mm.

4 Advanced R.C.C. Design 1.3 DETERMINATIN F BENDING MMENT AND SHEAR FRCE For this IS 456-000 permits use of any one of the following two methods: (a) The Direct Design Method (b) The Equivalent Frame Method 1.4 THE DIRECT DESIGN METHD This method has the limitation that it can be used only if the following conditions are fulfilled: (a) There shall be minimum of three continuous spans in each directions. (b) The panels shall be rectangular and the ratio of the longer span to the shorter span within a panel shall not be greater than. (c) The successive span length in each direction shall not differ by more than one-third of longer span. (d) The design live load shall not exceed three times the design dead load. (e) The end span must be shorter but not greater than the interior span. (f) It shall be permissible to offset columns a maximum of 10 percent of the span in the direction of the offset not withstanding the provision in (b). Total Design Moment The absolute sum of the positive and negative moment in each direction is given by M 0 = W n Where, M 0 = Total moment W = Design load on the area n n = Clear span extending from face to face of columns, capitals, brackets or walls but not less than 0.65 1 1 = ength of span in the direction of M 0 ; and = ength of span transverse to 1 In taking the values of n, 1 and, the following clauses are to be carefully noted: (a) Circular supports shall be treated as square supports having the same area i.e., squares of size 0.6D. (b) When the transverse span of the panel on either side of the centre line of support varies, shall b be taken as the average of the transverse spans. In Fig. 1.5 it is given by a + bg. (c) When the span adjacent and parallel to an edge is being considered, the distance from the edge to the centre-line of the panel shall be substituted for. Distribution of Bending Moment in to ve and +ve Moments The total design moment M 0 in a panel is to be distributed into ve moment and +ve moment as specified below:

Flat Slabs 5 In an interior span Negative Design Moment 0.65 M 0 Positive Design Moment 0.35 M 0 In an end span Interior negative design moment 010. = M075. - 1 1 + Positive design moment N M N M Exterior negative design moment a c 0. = 063. - 1 1 + = N M 065. 1 + Q P 1 0 a c M a c Q P Q P M 0 M where a c is the ratio of flexural stiffness at the exterior columns to the flexural stiffness of the slab at a joint taken in the direction moments are being determined and is given by a c Kc = Ks Where, K c = Sum of the flexural stiffness of the columns meeting at the joint; and K s = Flexural stiffness of the slab, expressed as moment per unit rotation. Distribution of Bending Moments Across the Panel Width The +ve and ve moments found are to be distributed across the column strip in a panel as shown in Table 1.1. The moment in the middle strip shall be the difference between panel and the column strip moments. 0 Table 1.1 Distribution of Moments Across the Panel Width in a Column Strip S. No. Distributed Moment Per cent of Total Moment a Negative BM at the exterior support 100 b Negative BM at the interior support 75 c Positive bending moment 60

6 Advanced R.C.C. Design Moments in Columns In this type of constructions column moments are to be modified as suggested in IS 456 000 [Clause No. 31.4.5]. Shear Force The critical section for shear shall be at a distance d from the periphery of the column/capital drop panel. Hence if drops are provided there are two critical sections near columns. These critical sections are shown in Figs. 1.1 to 1.4. The shape of the critical section in plan is similar to the support immediately below the slab as shown in Fig. 1.6. Critical section Support section column / column head d/ d/ Support section d/ ( a) Fig. 1.6 Critical section ( b) For columns sections with re-entrant angles, the critical section shall be taken as indicated in Fig. 1.7. Critical section Support section d/ Support section d/ Critical section d/ ( a) d/ ( b) d/ Fig. 1.7 In case of columns near the free edge of a slab, the critical section shall be taken as shown in Fig. 1.. Free edge Critical section Free corner d/ d/ ( a) Fig. 1. Corner column ( b) Critical section

Flat Slabs 7 The nominal shear stress may be calculated as t v = V bd 0 where V is shear force due to design b 0 is the periphery of the critical section d is the effective depth The permissible shear stress in concrete may be calculated as k s t c, where k s = 0.5 + b c but not greater than 1, where b c is the ratio of short side to long side of the column/capital; and t c = 05. f ck If shear stress t v < t c no shear reinforcement are required. If t c < t v < 1.5 t c, shear reinforcement shall be provided. If shear stress exceeds 1.5 t c flat slab shall be redesigned. 1.5 EQUIVAENT FRAME METHD IS 456 000 recommends the analysis of flat slab and column structure as a rigid frame to get design moment and shear forces with the following assumptions: (a) Beam portion of frame is taken as equivalent to the moment of inertia of flat slab bounded laterally by centre line of the panel on each side of the centre line of the column. In frames adjacent and parallel to an edge beam portion shall be equal to flat slab bounded by the edge and the centre line of the adjacent panel. (b) Moment of inertia of the members of the frame may be taken as that of the gross section of the concrete alone. (c) Variation of moment of inertia along the axis of the slab on account of provision of drops shall be taken into account. In the case of recessed or coffered slab which is made solid in the region of the columns, the stiffening effect may be ignored provided the solid part of the slab does not extend more than 0.15 l ef into the span measured from the centre line of the columns. The stiffening effect of flared columns heads may be ignored. (d) Analysis of frame may be carried out with substitute frame method or any other accepted method like moment distribution or matrix method. oading Pattern When the live load does not exceed ¾th of dead load, the maximum moments may be assumed to occur at all sections when full design live load is on the entire slab. If live load exceeds ¾th dead load analysis is to be carried out for the following pattern of loading also: (i) To get maximum moment near mid span ¾th of live load on the panel and full live load on alternate panel (ii) To get maximum moment in the slab near the support ¾th of live load is on the adjacent panel only It is to be carefully noted that in no case design moment shall be taken to be less than those occurring with full design live load on all panels. The moments determined in the beam of frame (flat slab) may be reduced in such proportion that the numerical sum of positive and average negative moments is not less than the value of total design

Advanced R.C.C. Design moment M 0 = W n. The distribution of slab moments into column strips and middle strips is to be made in the same manner as specified in direct design method. 1.6 SAB REINFRCEMENT Spacing The spacing of bars in a flat slab, shall not exceed times the slab thickness. Area of Reinforcement When the drop panels are used, the thickness of drop panel for determining area of reinforcement shall be the lesser of the following: (a) Thickness of drop, and (b) Thickness of slab plus one quarter the distance between edge of drop and edge of capital. The minimum percentage of the reinforcement is same as that in solid slab i.e., 0.1 percent if HYSD bars used and 0.15 percent, if mild steel is used. Minimum ength of Reinforcement At least 50 percent of bottom bars should be from support to support. The rest may be bent up. The minimum length of different reinforcement in flat slabs should be as shown in Fig. 1.9 (Fig. 16 in IS 456 000). If adjacent spans are not equal, the extension of the ve reinforcement beyond each face shall be based on the longer span. All slab reinforcement should be anchored property at discontinuous edges. Example 1.1: Design an interior panel of a flat slab of size 5 m 5 m without providing drop and column head. Size of columns is 500 500 mm and live load on the panel is 4 kn/m. Take floor finishing load as 1 kn/m. Use M0 concrete and Fe 415 steel. Solution: Thickness Since drop is not provided and HYSD bars are used span to thickness ratio shall not exceed 1 1 = 09. 3. \ Minimum thickness required = Span 5000. =. = 173.6 mm et d = 175 mm and D = 00 mm oads Self weight of slab = 0.0 5 = 5 kn/m Finishing load = 1 kn/m ive load = 4 kn/m \ Total working load = 10 kn/m Factored load = 1.5 10 = 15 kn/m

Flat Slabs 9 Middle Strip Column strip Strip Type of bars Straight bars Bent bars* Straight bars Bent bars* Minimum percentage of steel at section 50 Remainder 50 Remainder 50 Remainder 50 Remainder 100 50 Remainder 50 Remainder 50 Remainder WITHUT DRP PANE d b 75 mm max 150 mm 0.15lmax d b c WITH DRP PANE d e e b b b d b g o.15 l max 75 mm max. 150 mm 150 mm c (A BARS) 150 mm f c 75 mm max. c a 4 BAR DIA R 300 mm min. A BARS 150 mm min. b e c g EDGE F DRP e b 150 mm 4BAR DIA R 300 mm min. EDGE F DRP c 75 mm max. 0.15 l max 150 mm a c C (A BARS) f 150 mm 75 mm max. Exterior support D C Clear span - l n Face of support interior support D C Clear span - l n Face of support interior support [N SAB CNTINUITY] [CNTINUITY PRVED] [N SAB CNTINUITY] Minimum ength Bar ength From Face of Support D C Maximum ength Mark a b c d e f g ength 0.14 l n 0.0 l n 0. l n 0.30 l n 0.33 l n 0.0 l n 0.4 l n * Bent bars at exterior supports may be used if a general analysis is made. Note. D is the diameter of the column and the dimension of the rectangular column in the direction under consideration. Fig. 1.9 Minimum bend joint locations and extensions for reinforcement in flat slabs

10 Advanced R.C.C. Design n = 5 0.5 = 4.5 m \ Total design load in a panel W = 15 n = 15 5 4.5 = 337.5 kn Moments Panel Moment M 0 = W n 45. = 337. 5 =19. 4 knm Panel ve moment = 0.65 19.4 = 13.40 knm Panel +ve moment = 0.35 19.4 = 0.35 19.4 = 66.44 knm Distribution of moment into column strips and middle strip: Column Strip in knm Middle Strip in knm ve moment 0.75 13.40 = 9.55 30.5 +ve moment 0.60 66.44 = 39.6 6.5 Checking the thickness selected: Since Fe 415 steel is used, M u lim = 0.13 f ck b d Width of column strip = 0.5 5000 = 500 mm \ M u lim = 0.13 0 500 175 = 11.315 10 6 Nmm = 11.315 knm Hence singly reinforced section can be designed i.e., thickness provided is satisfactory from the consideration of bending moment. Check for Shear The critical section for shear is at a distance d from the column face. Hence periphery of critical section around a column is square of a size = 500 + d = 500 + 175 = 675 mm Shear to be resisted by the critical section V = 15 5 5 15 0.675 0.675 = 36.166 kn 36166. 1000 \ t v = = 0.779 N/mm 4 675 175 k s =1 + b c subject to maximum of 1. b c = 1 5 = = 1 5 \ k s =1 safe in shear since t v < t c t c = 0. 5 f ck = 0. 5 0 = 1.11 N/mm 675 500 500 675

Reinforcement For ve moment in column strip: M u = 9.55 knm N M 9.55 10 6 Ast = 07. fy A st d 1 bd A i.e., 1464.7 = A st 1 st 104. 3 y ck Q P = 0.7 415 A st 175 1 500 175 f f A st 415 0 Flat Slabs 11 i.e., A st 104.3A st + 1464.7 104.3 = 0 A st = 153.74 mm This is to be provided in a column strip of width 500 mm. Hence using 1 mm bars, spacing required is given by s = p 4 1 500 = 17 mm 153. 74 Provide 1 mm bars at 175 mm c/c. For +ve moment in column strip: M u = 39.6 knm \ 39.6 10 6 = 0.7 415 A st 175 1 500 175 A 630.6 = A st 1 st 104. 3 or A st 104.3 A st + 630.6 104.3 = 0 \ A st = 651 mm Using 10 mm bars, spacing required is s = p 4 10 500 = 301.6 mm < thickness of slab 651 Hence provide 10 mm bars at 300 mm c/c. Provide 10 mm diameter bars at 300 mm c/c in the middle strip to take up ve and +ve moments. Since span is same in both directions, provide similar reinforcement in other direction also. A st 415 0

1 Advanced R.C.C. Design Reinforcement Details It is as shown in Fig. 1.10 Column Strip Middle Strip Column strip Column Strip Middle Strip Column strip 1-175 c/c 1-175 c/c 10-300 c/c 10-300 c/c 5000 5000 5000 Sign convention Top reinforcement Bottom reinforcement 5000 5000 5000 1-175 c/c 00 10-300 c\c Cover -5 500 3000 Section through column strip 10-300 c/c 500 3000 500 500 section through middle strip Fig. 1.10 Reinforcement details [all dimension in mm units] Example 1.: Design an interior panel of a flat slab with panel size 6 6 m supported by columns of size 500 500 mm. Provide suitable drop. Take live load as 4 kn/m. Use M0 concrete and Fe 415 steel. Solution : Thickness : Since Fe 415 steel is used and drop is provided, maximum span to thickness ratio permitted is 3 \ Thickness of flat slab = 6000 = 17.5 mm 3 Provide 190 mm thickness. et the cover be 30 mm \ verall thickness D = 0 mm et the drop be 50 mm. Hence at column head, d = 40 mm and D = 70 mm

Flat Slabs 13 Size of Drop It should not be less than 1 6 m = m 3 et us provide 3 m 3 m drop so that the width of drop is equal to that of column head. \ Width of column strip = width of middle strip = 3000 mm. oads For the purpose of design let us take self-weight as that due to thickness at column strip \ Self-weight = 0.7 1 1 5 = 6.75 kn/m Finishing load = 1.00 kn/m ive load = 4.00 kn/m Total load = 11.75 kn/m \ Design (factored) load = 1.5 11.75 = 17.65 kn/m Clear span n = 6 0.5 = 5.5 m \ Design load W 0 =W u n = 17.65 6 5.5 = 51.65 kn Design Total Moment Total moment M 0 = W 0 n 5165. 55. = = 400 knm \ Total negative moment = 0.65 400 = 60 knm Total positive moment = 0.35 400 = 140 knm The above moments are to be distributed into column strip and middle strip Column Strip Middle Strip ve moment 0.75 60 = 195 knm 0.5 60 = 65 knm +ve moment 0.6 140 = 4 knm 0.4 140 = 56 knm Width of column strip = width of middle strip = 3000 mm M u lim = 0.13 f ck b d = 0.13 0 3000 40 = 476.9 10 6 Nmm = 476.9 knm Thus M u lim > M u. Hence thickness selected is sufficient. Check for Shear The critical section is at a distance

14 Advanced R.C.C. Design d = 40 = 10 mm from the face of column \ It is a square of size = 500 + 40 = 740 mm V = Total load load on 0.740 0.740 area = 17.65 6 6 17.65 0.740 0.740 = 64.49 kn 64. 49 1000 \ Nominal shear = t v = = 0.0 N/mm 4 740 40 Shear strength = k s t c where k s = 1 + b c subject to maximum of 1 740 500 where b c = 1 = 1 \ k s =1 t c = 05. 0 = 1.11 N/mm Design shear stress permitted = 1.11 N/mm > t v Hence the slab is safe in shear without shear reinforcement also. 500 740 10 500 10 Shear strength may be checked at distance d from drop. It is quite safe since drop size is large. Reinforcement (a) For ve moment in column strip M u = 195 knm Thickness d = 40 mm \ M u = 0.7 f y A st d 1 b d N M A st 195 10 6 = 0.7 415 A st 40 1 3000 40 A 50.3 = A st 1 st 3469. A st 3469. A st + 50.3 3469. = 0 A st = 419 mm in 3000 mm width f f y ck Q P A st 415 0

Flat Slabs 15 Using 1 mm bars, spacing required is s = p 4 1 3000 = 140.6 mm 419 Provide 1 mm bars at 140 mm c/c (b) For +ve moment in column strip M u = 4 knm = 4 10 6 Nmm. Thickness d = 190 mm 4 10 6 = 0.7 415 A st 190 1 3000 40 A 14.5 = A st 1 st 7469. 9 \ A st = 15 mm Using 10 mm bars s = p 4 10 15 Provide 10 mm bars at 10 mm c/c (c) For ve moment in middle strip: M u = 65 knm; Using 10 mm bars 3000 = 13 mm A st Thickness = 190 mm 65 10 6 = 0.7 415 A st 190 1 3000 190 A 947.5 = A st 1 st 7469. 9 7469.9 A st + 947.5 7469.9 = 0 A st = 93 mm in 3000 mm width A st s = p 4 10 3000 = 39.7 mm 93 Provide 10 mm bars at 30 mm c/c (d) For +ve moment in middle strip M u = 56 knm; Thickness = 190 mm Provide 10 mm bars at 30 mm c/c in this portion also. Since span is same in both direction, provide similar reinforcement in both directions. The details of reinforcement are shown in Fig. 1.11. A st 415 0 415 0

Middle strip 16 Advanced R.C.C. Design Column strip =Dorp width Middle strip 1 140 c/c Column strip =Dorp width Column strip =Dorp width 10 10c/c 6000 10 30 c/c 1 30c/c 6000 Column strip =Dorp width 10 10c/c 6000 6000 6000 6000 1 @ 140 10 @ 10 c/c 190 40 10 @ 30 Cover - 30 500 500 Section through column strip 10 @ 30 c/c 500 500 Fig. 1.11 Reinforcement details 40 190 Example 1.3: Design the interior panel of the flat slab in example 1., providing a suitable column head, if columns are of 500 mm diameter. Solution: et the diameter of column head be = 0.5 = 0.5 6 = 1.5 m It s equivalent square has side a where π 4 15. = a a = 1.33 m \ n = 6 1.33 = 4.67 m W 0 = 17.65 6 4.67 = 493.5 kn M 0 = W o n 493. 5 4. 67 = =.3 knm

Flat Slabs 17 \ Total ve moment = 0.65.3 = 17.4 knm Total +ve moment = 0.35.3 = 100.9 knm The distribution of above moment into column strip and middle strips are as given below: Column Strip Middle Strip ve moment 0.75 17.4 = 140.55 knm 0.5 17.4 = 46.5 knm +ve moment 0.60 100.9 = 60.54 knm 0.4 100.9 = 40.36 knm Width of column strip = width of middle strip = 3000 mm \ M u lim = 0.13 f ck bd = 0.13 0 3000 40 = 476.9 10 6 Nmm > M u Hence thickness selected is sufficient. Check for Shear The critical section is at a distance d = 40 = 10 mm from the face of column head Diameter of critical section = 1500 + 40 =1740 mm = 1.740 m Perimeter of critical section = p D = 1.740 p Shear on this section p V = 17. 65 6 6-174. = 59.59 kn 4 59. 59 1000 \ t v = = 0.45 N/mm π 1740 40 Maximum shear permitted = k s 05. 0 = 1.11 N/mm Since k s works out to be 1 Since maximum shear permitted in concrete is more than nominal shear t v, there is no need to provide shear reinforcement Design of Reinforcement (a) For ve moment in column strip M u = 140.55 knm; d = 40 mm \ 140.55 10 6 = 0.7 415 A st 40 1 3000 40 A 16 = A st 1 st 3469. A st 415 0 1500 10

1 Advanced R.C.C. Design A st 3469. A st + 16 3469. = 0 A st = 1705 mm Using 1 mm bars, s = π 4 1 3000 = 199 mm 1705 Provide 1 mm bars at 190 mm c/c. (b) For the +ve moment in column strip M u = 60.54 knm; d = 190 mm Using 10 mm bars 60.54 10 6 = 0.7 415 A st 190 1 3000 190 A.51 = A st 1 st 7469. 9 A st 7469.9 A st +.51 7469.9 = 0 A st = 913 mm s = π 4 10 3000 = 5 mm 913 Provide 10 mm bars at 50 mm c/c. (c) For ve moment in middle strip: M u = 46.5 knm; d = 190 mm Using 10 mm bars, A st 46.5 10 6 = 0.7 415 A st 190 1 3000 190 A 63 = A st 1 st 7469. 9 A st 7469.9A st + 63 7469.9 = 0 A st = 701 mm s = π 4 10 3000 = 336 mm 701 Provide 10 mm bars at 300 mm c/c. (d) Provide 10 mm bars at 300 mm c/c for +ve moment in middle strip also. As span is same in both directions, provide similar reinforcement in both directions. Reinforcement detail may be shown as was done in previous problem. Example 1.4: A flat slab system consists of 5 m 6 m panels and is without drop and column head. It has to carry a live load of 4 kn/m and a finishing load of 1 kn/m. It is to be designed using M0 grade concrete and Fe 415 steel. The size of the columns supporting the system is 500 500 mm and floor to floor height is 4.5 m. Calculate design moments in interior and exterior panels at column and middle strips in both directions. A st 415 0 415 0

Flat Slabs 19 Solution: Thickness: Since Fe 415 steel is used and no drops are provided, longer span to depth ratio is not more than 3 0.9 =. d = 6000 = 0. et us select d = 10 mm and D = 40 mm oads Self weight 0.4 1 1 5 = 6 kn/m Finishing weight = 1 kn/m ive load = 4 kn/m Total = 11 kn/m W u = 1.5 11 = 16.5 kn/m Panel Dimensions Along length 1 = 6 m and = 5 m Width of column strip = 0.5 1 or whichever is less. = 0.5 5 = 1.5 m on either side of column centre line \Total width of column strip = 1.5 =.5 m Width of middle strip = 5.5 =.5 m Along Width 1 =5 m = 6 m Width of column strip = 0.5 5 = 1.5 m on either side \Total width of column strip =.5 m Hence, width of middle strip = 6.5 = 3.5 m INTERIR PANES Moments Along onger Size 1 =6 m = 5 m n = 6 0.5 = 5.5 m subject to minimum of 0.65 1 = 3.9 m \ n = 5.5 m oad on panel W 0 = 16.5 n = 16.5 5 5.5 = 453.75 kn

0 Advanced R.C.C. Design M 0 = W 0 n = 45375. 55. = 311.95 knm Appropriation of Moment Total ve moment = 0.65 311.95 = 0.77 knm \ Total +ve moment = 311.95 0.77 = 109.1 knm Hence moment in column strip and middle strip along longer direction in interior panels are as given below: Column Strip Middle Strip ve moment 0.75 0.75 = 15.06 knm 0.75 15.06 = 50.69 knm +ve moment 0.60 109.1 = 65.51 knm 109.1 65.51 = 43.67 knm Along Width 1 =5 m = 6 m and n = 5 0.5 = 4.5 m. Panel load = W 0 = 16.5 6 4.5 = 445.5 kn Panel moment M 0 = W 0 n = 4455. 4. 5 = 50.59 kn-m Appropriation of Moment: Total ve moment = 0.65 50.59 = 16. kn-m Total +ve moment = 50.59 16. = 7.71 kn-m \ Moments in column strip and middle strip are as shown below: Column Strip Middle Strip ve moment 0.75 16. = 1.16 knm 0.5 16. = 40.7 knm +ve moment 0.60 7.71 = 5.63 knm 0.40 7.71 = 35.0 knm EXTERIR PANES ength of column = 4.5 0.4 = 4.6 m The building is not restrained from lateral sway. Hence as per Table in IS 456-000, effective length of column = 1. length = 1. 4.6 = 5.11 m Size of column = 500 500 mm Moment of inertia of column = 1 500 4 mm 4 1

Flat Slabs 1 \ k c = I 1 = 500 1 511 4 = 10144 mm 4 NGER SPAN DIRECTIN Moment of inertia of beam I s = Moment of inertia of slab = 1 6000 40 3 1 Its length = = 5000 mm \ k c = I 3 s 1 6000 40 = = 13400 mm 4 5000 1 5000 ive load Dead load = 4 7 < 0.75 \ Relative stiffness ratio is a c = k c1 + k c 10144 = = 1.474 k 13400 1 1 \ a = 1 + = 1+ = 1.67 a c 1474. Hence various moment coefficients are: Interior ve moment coefficient = 0.75 01. α = 0.690 Exterior ve moment coefficient = 0.65 α = 0.37 Positive moment coefficient = 0.63 0. α = 0.463 Total moment M 0 = 311.95 knm \ Appropriation of moments in knm is as given below: s Total Column Strip Middle Strip Interior ve 0.69 311.95 = 15.5 0.75 15.5 = 161.43 15.5 161.43 = 53. Exterior ve 0.37 311.95 = 10.7 1.00 10.7 = 10.7 10.7 10.7 = 0 + Moment 0.463 31.95 = 144.43 0.60 144.43 = 6.66 144.43 6.66 = 57.77 Shorter Span Direction \ k s = 1 5000 40 = 96000 1 6000 \ a c = k c1 + k c 10144 = =.13 k 960000 s 3

Advanced R.C.C. Design 1 \ a 1 = 1 + = 1.471 αc Interior ve moment coefficient = 0.75 01. 01. 075. a = - 1. 471 = 0.6 0.65 0.65 Exterior ve moment coefficient = α = = 0.44 1. 471 0. 0. Positive moment coefficient = 0.63 α = 063. 1. 471 = 0.440 Total moment M 0 = 50.59 knm \ Appropriation of moments in shorter span exterior panel in knm is as given below: Total Column Strip Middle Strip Interior ve 0.6 50.59 = 170.90 0.75 170.76 = 1.1 170.90 1.1 = 4.7 Exterior -ve 0.44 50.59 = 110.76 1.00 110.76 = 110.76 110.76 110.76 = 0 + Moment 0.44 50.59 = 110.5 0.60 110.5 = 66.16 110.5 66.16 = 44.09 In the exterior panel in each column strips half the above values will act. These moments are shown in Fig. 1.1 Col Strip Middle Strip Col Strip Middle Strip Col Strip.5 m 10.7 1.16 53. 5.63 161.43 15.06 1.16 50.69 5.63 15.06 1.16 3.5 m 6.66 40.7 57.77 35.0 6 66.. 65 51 40.7 43.67 35.0 65.51 40.7.5 m 10.7 1.16 1.1 53. 5.63 66.16 161.43 15.06 1.16 1.1 50.69 5. 63 66.16 15.06 1.16 1.1 3.5 m 6.66 4.7 57.77 44.09 6 66.. 65 51 4.7 43.67 44.09 65.51 4.7 1.5 m 10.7 4 110.76 53. 66.16 161.43 15.06 110.76 50.69 66.16 15.06 110.76 1.5.5.5.5.5 Fig. 1.1

Flat Slabs 3 REVIEW QUESTINS 1. Design the typical interior panel of a flat slab floor of size 5 m 5 m with suitable drop to support a live load of 4 kn/m. The floor is supported by columns of size 450 mm 450 mm. Use M0 concrete and Fe 415 steel. Sketch the reinforcement details by showing cross sections (i) at column strip (ii) at middle strip.. Design the exterior panel of a flat slab of size 6 m 6 m with suitable drop to support a live load of 5 kn/m. The floor system is supported by columns of size 500 mm 500 mm. Floor to floor distance is 3.6 m. Use M0 concrete and Fe 415 steel. 3. For the flat slab system of size 6 m 6 m provide suitable drop and fix up overall dimensions. The floor system is supported by columns of size 500 mm 500 mm, the floor height being 3.6 m. Calculate the design moments at various strips in the interior and exterior panels. Give the plan of the floor system showing these design moments.