Visionary Façade Concepts with Solar-Control Glazing. x ipasol x Stopray x Sunergy x Stopsol

Similar documents
Solar-Control Glazing. Visionary Façade Concepts

IPLUS. Energy saving begins with the right glazing FOCUS ON THERMAL INSULATION FOR RESIDENTIAL BUILDINGS AND HOMES

Iv. Absolute Towers, Ontario, Canada Architect: Yansong Ma

OKAWOOD - Insulating Glass with Wooden Grid

CONTENTS. Abbreviations: LT: Daylight Transmittance LR ext: Reflectance Outdoor SF: Solar Factor

OKAWOOD - Insulating Glass with Wooden Grid

INFOTEXT. OKALUX Light Diffusing Insulating Glass. Physical properties

OKAWOOD - Insulating Glass with Wooden Grid

OKALUX GmbH Marktheidenfeld Germany Tel.: +49 (0) Fax: +49 (0)

STOPSOL c r e a t e l a s t i n g r e f l e c t i o n s GLASS UNLIMITED

Solar Control. Pilkington Solar Control range

Highly Transparent & Energy Saving Glass for Green Buildings

ENERGY EFFICIENT GLASS LESS ENERGY, MORE SAVINGS, BETTER FUTURE

OKATECH Insulating Glass with Metal Interlayer

Glazing with Integral Sun Control Louvres

Coated Glass. Stopsol Sunergy Planibel G

Glazing with Integral Sun Control Louvres

Glazing with Integral Sun Control Louvres

Infosheet. Planibel Coloured. the range of AGC tinted float glasses. You have printed. Green, PrivaBlue, Dark Blue, Grey, Bronze, Azur, Dark Grey

HNG Float Glass. Corporate Head Office Mumbai Plant Location Halol (45 Kms from Vadodara) Regd Office Kolkata

SGG PLANITHERM TOTAL New generation advanced performance low-e glass

Pursuing active policy of Innovation, AGC Glass Europe is renowned for its extensive product range.

Solar control glass. 2/7 SGG ANTELIO United Kingdom SAINT-GOBAIN GLASS COMFORT

INTELLIGENT GLASS SYSTEMS

Assessing the energy performance of modern glass facade systems

LUXAR. Anti-reflective glass

Pilkington Sunplus BIPV Powered by NEXBuilding. Provides power generating solutions for vertical and horizontal applications

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world

Performance Standards of Glass Products Manufactured by Pilkington IGP

ECONTROL SOLAR CONTROL WITH DIMMABLE GLASS

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls. 1 R2 R3. High tech? Low tech?

Folly or innovation suggestions for a sensible approach to the U-value Olympics

NEED FOR A CORRECT GLASS DESCRIPTIVE CODE: ENERGY-CODING

hansen glass processors HansenGlass ThermoCool insulating glass - For Environmental Management

Sound insulation Capillary slabs decouple the panes of the insulating glazing and provide improved sound insulation.

ClimaGuard Neutral 70

LightBridge High performance residential double glazing for superb comfort and natural light in your home

Pilkington Solar Control Range

Products for Energy Applications

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

European Timber Windows & Doors

Insulated Glass Units

JE Berkowitz, L.P. Architectural Glazing Guide Specification for Enviroscreen Silk-Screened Glass

LoE LoE LoE-i89 Clear & Grey. Glassworks performance range

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

Unbeatable energy efficient glass curtain wall system

GLASS SELECTION GUIDE

SILVERSTAR-Solar control glass

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

The colours of the sun

Glass. for insulation IPLUS FOCUS ON THERMAL INSULATION FOR RESIDENTIAL BUILDINGS AND HOMES

Product information Top-operated centre-pivot polyurethane roof window GGU

SP Glass is the leading Russian company producing coated glass and insulated glass products. Integrated network of efficient and modern production

Poor distribution & glare

for automatic doors Range of LEAVES

Products for Energy Applications

AMIRAN ANTI-REFLECTIVE GLASS

Product information Vertical window element VIU

WARM-EDGE-SYSTEMS KÖDISPACE & KÖDISPACE 4SG

Optimum Design Parameters of Box Window DSF Office at Different Glazing Types under Sub Interval of Intermediate Sky Conditions (20-40 klux)

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

Clear float glass. Pilkington OptiView. Anti-reflective Glass

INSULATED GLASS UNITS TWO PANELS OF GLASS ARE BETTER THAN ONE

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

GlassWin System. Structural glazing with PVC-U profiles

Product information Vertical window element VFE

Multi-Cavity Insulating Glass Units

Product information Additional window element GIL

Technical specification for arcon coatings. for arcon coatings. Issue:

HONG KONG GREEN BUILDING COUNCIL

Smart. Easy. Profitable.

SMART SOLUTIONS DOUBLE GLAZING SOLAR COMFORT TINTING GLASS ASK OUR SALES REPRESENTATIVES ABOUT. Reduce your 23% energy costs * by as much as

Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

In office buildings, often large windows have been. Total economy of windows and facades in low energy office buildings. Articles

Innovative Thermal Management & Daylight Design Opportunities For the Sustainable Building Glass Envelope

Clear float glass. Anti-reflective Glass Pilkington OptiView and Pilkington OptiView OW

PRACTICAL GUIDE MULTIVER RESIDENTIAL GLASS. Quebec. Version 2.0

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

MorrisonWindows. Features and BenefIts. Insulated Glass Units. Options. ProfIle Colour Options. 500/508 Series Window

System Solutions for Structural Glazing

Characterization and performance evaluation of solar shading devices

Spandrel Glass Types and Recommendations

SYSTEM SOLUTIONS FOR STRUCTURAL GLAZING

COOLING LOADS AND OCCUPANT COMFORT IN HIGHLY GLAZED BUILDINGS AND THE EFFECTIVE EVALUATION OF WINDOW RETROFITS

Warm Edge Glazing Systems. High-Performance Insulated Glass Packages

World s best-performing glass curtain wall

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

Product information Centre-pivot white-painted roof window GGL

Product information Top-hung roof window GPL

PRACTICAL ADVICE ON WRITING ARCHITECTURAL SPECIFICATIONS

OPTIWIN MOTURA. Technical Description. Synopsis:

EGL Technical Bulletin 011. Visual Effects in Insulating Glass Units (IGUs)

Product information Top-hung white polyurethane roof window GPU

LITEWALL Point Fixed Glass Facades

Product information Additional window element GIU

SECTION SPECIAL FUNCTION GLAZING

SEALANT COMPATIBILITY STRUCTURAL GLAZING STOPRAY SMART. Technical information

Q-Air detailed physical properties

Special Applications. Low-iron clear float glass. Pilkington Optiwhite

Transcription:

Visionary Façade Concepts with Solar-Control Glazing x ipasol x Stopray x Sunergy x Stopsol

x ipasol x Stopray x Sunergy x Stopsol The Age of Glass Glass architecture is the architecture of the 21st century. Glass façades dominate the cities of the world. Glass fires the imagination of designers. Glass has taken centre stage. But visionary architecture needs high-tech glass. The visual and energy-relevant demands on building envelopes are constantly being raised.this applies particularly for transparent solar control: astronomical costs for air-conditioning loom in summer and for heating in winter. Innovative approaches to control the indoor climate have become imperative! The general trend is toward colour-neutral glazing with a low level of exterior reflection. However, glazing with colour accents or higher reflectance is experiencing a renaissance in some regions. The potential lies in the coating technology: in a complex process, multi-layer coatings are applied to the surface of float glass. Only glass that has been processed in this way has proven to be a multi-purpose, high-quality product that reduces overheating and saves heating energy.

A family of products with an extra touch of class The strategic alliance which brings Interpane and AGC together allows for those sun protection glass formats to be selected from the product ranges of both partners which provide the greatest possible performance. And that means planners and glass processors have a product portfolio to choose from with truly unique capabilities. These include what has to be the most comprehensive range anywhere of triple silver-coated product variants. These types provide the ideal solution for highest possible light transmission with lowest possible solar factor. Whether it s ipasol, Stopray or Sunergy - all of them have proved their structural physical and optical advantages in major projects all over the world.

x ipasol x Stopray x Sunergy x Stopsol Harnessing the Sun The right combination of values The performance of solar-control glazing depends on various parameters such as total solar energy transmittance, light transmittance, thermal insulation, transparency and colour neutrality. Since innovative coating processes have established as the state of the art, it is important to find the right combination of technical specifications. What is the point of having the most effective solar control, if expensive or unpleasant artificial lighting must be used inside the building, or the view to the outside is hindered? A further criterion is the widespread desire for colour-neutral façade designs. Creative solutions from glass processors are in strong demand. Highly selective coatings With its combinations of performance specifications, the AGC Interpane product range often approaches the limits of what is physically feasible. Members of the latest generation have highly complex coating systems, which are composed of up to ten individual layers. They are all variations of a single principle: The highly selective coatings reflect most of the long-wave solar radiation (lower g value) while transmitting as much short-wave radiation (daylight) as possible (higher v value). Most of the heat remains outside, but not the light. In this way, this family of products can optimally meet the seemingly irreconcilable requirements on modern architectural glazing. Solar-control coating Outside Inside Inert gas Spacer bar Desiccant Butyl primary sealant Secondary sealant, e.g. polysulphide / PU An example of the structure of a sun protection insulating glass unit

Total solar energy transmittance g value 42 % (in accordance with EN 410) Light transmittance L value 73 % (in accordance with EN 410) Thermal transmittance U g value 1.1 W/m 2 K (in accordance with EN 673) Light and radiation technical values: Optimum composition Minimal costs, maximum aesthetics High performance solar control glass, with its excellent performance, helps saving money, pure and simple. It perceptibly delays and reduces the heating up of a room in summer, and so substantially reduces the costs of cooling, which are often a few times higher than heating costs in winter. As well as this, it also improves the psychological atmosphere of a room, because areas flooded with natural light, boost the motivation and productivity of the people working in the building. And in winter, our solar control types provide excellent thermal insulation, too. They enhance the quality of life, help to protect the environment, and to reduce operating costs. This gives visionary architecture a financially powerful foundation, as well. Harmonious façade perfection - in detail Façades often only achieve perfect harmony thanks to a fully enclosed glass frontage. For completely glazed façades, AGC Interpane can offer a wide selection of options, with top quality of spandrel panels perfectly matched to the solar control range. This means that the whole building envelope can be designed homogeneous and functional. Spandrel panels are available with single or double glazing, with or without additional thermal insulation. The functional benefits are obvious. Spandrel panels are: resistant to weathering resistant to environmental influences durable mechanically stable

x ipasol x Stopray x Sunergy x Stopsol Making visions a reality Giga Lites : Glass in super dimensions In Europe, the maximum dimensions to which standard insulating glass products can be manufactured are limited, as a rule, by the dimensions of the uncoated float glass, and those values are 3,210 mm x 6,000 mm. But really exciting architectural concepts often come to life simply because these limits are overcome. We have grasped this trend perfectly, and taken the lead in the development of super-dimensioned glazing products. This makes it possible for float glass panes to be coated up to a length of 18,000 mm with top quality solar control layers or also with Low-E. Tempered safety glass or heat-strengthened glass, as well as laminated safety glass, can be manufactured up to 9,000 mm in length, and insulation glass units up to 12,000 mm. The dimensions for screen-printed or digitally-printed glazing products have also been extended well beyond the limits of the tape measure. Of course, if Giga-Lite glazing is going to be used all the details need to be agreed with the production plant beforehand. But the rewards for careful planning are architecturally unique concepts, of a size and scope which have been inconceivable up to now. Just ask us: Together, we can make the wildest dream come true! Structural glazing with gas-impermeable silicone edge sealant Based on the well-proven principle of the metal spacer bar with a dual sealing system, a new type of gas-impermeable edge sealant with silicone as the secondary sealing material was developed. This allows, for example, structural glazing systems to create that are based on the principle of mounting glazing elements with an exposed edge seal. This high-grade silicone edge sealant system is not only UV-resistant but also allows to fill the cavity between the panes with argon or krypton, due to its high gas impermeability. Visionary architecture needs future-orientated products.

Product Range and Technical Data: Solar-Control glazing Product name Assembling outer pane/ (space argon/ centre/) space argon/ inner pane U g -value according to EN 673 Solar Factor Rated light and solar-radiation properties according to EN 410 Light Transmission Light Reflection outdoors Energy Absorption outer pane Energy Absorption middle pane Energy Absorption inner pane Selectivity Shading Coefficient (Solar Factor EN 410/0,80) Shading Coefficient (Solar Factor EN 410/0,87) Thickness Weight mm W/(m 2 K) % % % % % % % % mm kg/m 2 Double Glazing ipasol ipasol neutral 70/39 6:/16/4 1,0 39 70 12 33 2 1,79 49 45 26 25 ipasol neutral 69/37 6:/16/4 1,0 37 69 12 31 2 1,84 46 43 26 25 ipasol ultraselect 62/29 6:/16/4 1,0 29 62 10 32 1 2,14 36 33 26 25 ipasol neutral 60/33 6:/16/4 1,0 33 60 11 39 1 1,82 41 38 26 25 ipasol neutral 50/27 6:/16/4 1,1 27 50 9 48 1 1,85 34 31 26 25 ipasol platin 47/29 6:/16/4 1,0 29 47 40 29 2 1,62 36 33 26 25 ipasol shine 40/22 6:/16/4 1,1 22 40 16 53 1 1,82 28 25 26 25 ipasol sky 30/17* 6:/16/4 1,1 17 30 18 63 1 1,76 21 20 26 25 ipasol platin 25/17 6:/16/4 1,0 17 25 64 19 1 1,47 21 20 26 25 ipasol bright neutral 6:/16/:4 1,1 47 57 35 17 6 1,21 59 54 26 25 ipasol bright white 6:/16/:4 1,1 51 58 36 4 7 1,14 64 59 26 25 Stopray Stopray Ultra 60 6:/16/4 1,0 28 60 13 37 1 2,14 35 32 26 25 Stopray Vision-60 6:/16/4 1,0 35 61 15 36 1 1,74 44 40 26 25 Stopray Vision-60T 6:/16/4 1,0 37 60 14 36 2 1,62 46 43 26 25 Stopray Vision-50 6:/16/4 1,0 28 50 19 41 1 1,79 35 32 26 25 Stopray Vision-50T 6:/16/4 1,0 30 50 17 39 1 1,67 38 34 26 25 Stopray Ultra-50 on Clearvision 6:/16/4 1,0 23 49 18 32 1 2,13 29 26 26 25 Stopray Silver 6:/16/4 1,0 26 43 47 26 1 1,65 33 30 26 25 Stopray Vision-36T 6:/16/4 1,0 21 36 3 1 40 0 1,71 26 23 26 25 Stopray Vision 60 (Planibel GfasT Pos. 4) 6:/16/4: 0,9 34 56 16 36 4 1,65 43 39 26 25 Stopray Vision 60T (Planibel GfasT Pos. 4) 6:/16/4: 0,9 36 55 15 37 4 1,53 45 41 26 25 Stopray Vision 50 (Planibel GfasT Pos. 4) 6:/16/4: 0,9 27 46 19 41 3 1,70 34 31 26 25 Stopray Vision 50T (Planibel GfasT Pos. 4) 6:/16/4: 0,9 29 46 18 39 3 1,59 36 33 26 25 Stopray Silver (Planibel GfasT Pos. 4) 6:/16/4: 0,9 26 40 48 26 3 1,54 33 30 26 25 Stopray Vision 36T (Planibel GfasT Pos. 4) 6:/16/4: 0,9 20 33 31 40 2 1,65 25 23 26 25 Sunergy Sunergy Clear 6:/16/:4 1,1 45 61 11 42 5 1,36 56 52 26 25 Sunergy Green* 6:/16/:4 1,1 30 50 9 66 2 1,67 38 34 26 25 Sunergy Azur* 6:/16/:4 1,1 32 50 9 63 2 1,56 40 37 26 25 Sunergy Dark blue* 6:/16/:4 1,1 26 36 7 71 2 1,38 33 30 26 25 Sunergy Grey* 6:/16/:4 1,1 27 30 6 68 3 1,11 34 31 26 25 Triple Glazing ipasol ipasol neutral 70/39 6:/14/4/14/:4 0,6 35 62 14 33 2 3 1,77 44 40 42 35 ipasol neutral 69/37 6:/14/4/14/:4 0,6 33 62 14 32 2 3 1,88 41 38 42 35 ipasol ultraselect 62/29 6:/14/4/14/:4 0,6 27 55 11 33 1 2 2,04 34 31 42 35 ipasol neutral 60/33 6:/14/4/14/:4 0,6 30 54 13 40 2 3 1,80 38 34 42 35 ipasol neutral 50/27 6:/14/4/14/:4 0,6 24 45 10 49 1 2 1,88 30 28 42 35 ipasol platin 47/29 6:/14/4/14/:4 0,6 26 42 41 29 2 3 1,62 33 30 42 35 ipasol shine 40/22 6:/14/4/14/:4 0,6 20 36 17 53 1 2 1,80 25 23 42 35 ipasol sky 30/17* 6:/14/4/14/:4 0,6 15 27 19 63 1 1 1,80 19 17 42 35 ipasol platin 25/17 6:/14/4/14/:4 0,6 15 22 64 20 1 2 1,47 19 17 42 35 ipasol bright neutral 6:/14/4/14/:4 0,9 43 53 38 16 7 5 1.,23 54 49 42 35 ipasol bright white 6:/14/4/14/:4 0,9 47 54 39 5 8 6 1,15 59 54 42 35 Stopray Stopray Ultra 60 6:/14/4/14/:4 0,6 26 53 14 38 1 2 2,04 33 30 42 35 Stopray Vision 60 6:/14/4/14/:4 0,6 31 55 17 37 2 3 1,77 39 36 42 35 Stopray Vision 60T 6:/14/4/14/:4 0,6 33 54 16 37 2 3 1,64 41 38 42 35 Stopray Vision 50 6:/14/4/14/:4 0,6 25 45 20 42 1 2 1,80 31 29 42 35 Stopray Vision 50T 6:/14/4/14/:4 0,6 27 45 19 39 2 2 1,67 34 31 42 35 Stopray Ultra 50 on Clearvision 6:/14/4/14/:4 0,6 21 44 20 33 1 2 2,10 26 24 42 35 Stopray Silver 6:/14/4/14/:4 0,6 24 39 48 26 2 2 1,62 30 28 42 35 * The outer pane is made of thermally toughened glass ( ESG), thermally toughened glass with heat soak test ( ESG-H) or heat-strengthened glass. x The customer ordering our products is responsible for ensuring that the glass thickness is dimensioned correctly according to the applicable technical regulations. x The specified rated values refer to the testing conditions and the application scope of the r eferenced standard. Non vertical position leads to different values. x : indicates the position of the coatings. x If the energy absorption of the outer pane exceeds 55 % (ver tical glazing) or 50 % (inclined glazing), we recommend the use of thermally treated safety glass. changes possible Status as of October 2014

Your partner for glazing: Germany: 37697 Lauenförde Sohnreystraße 21 Tel.+49 (0) 52 73 8 09-0 Fax +49 (0) 52 73 85 47 e-mail: lauenfoerde@interpane.com 04874 Belgern Liebersee 54 Tel.+49 (0) 3 42 24 4 33-0 Fax +49 (0) 3 42 24 4 33-11 e-mail: belgern@interpane.com 16775 Löwenberger Land/OT Häsen Timpbergstraße 15 Tel.+49 (0) 3 30 84 7 98-0 Fax +49 (0) 3 30 84 7 98-23 e-mail: haesen@interpane.com 21614 Buxtehude Weidegrund 3 Tel.+49 (0) 41 61 70 72-0 Fax +49 (0) 41 61 70 72-60 e-mail: buxtehude@interpane.com 39171 Sülzetal/OT Osterweddingen Appendorfer Weg 5 Tel.+49 (0) 39205 450-440 Fax +49 (0) 39205 450-449 e-mail: igd@interpane.com 31135 Hildesheim Maybachstraße 5 Tel.+49 (0) 51 21 76 23-0 Fax +49 (0) 51 21 5 57 64 e-mail: hildesheim@interpane.com 51688 Wipperfürth Böswipper 22 Tel.+49 (0) 22 69 5 51-0 Fax +49 (0) 22 69 5 51-1 55 e-mail: wipperfuerth@interpane.com 94447 Plattling Robert-Bosch-Straße 2 Tel.+49 (0) 99 31 9 50-0 Fax +49 (0) 99 31 69 04 e-mail: plattling@interpane.com IBC Consulting Center for Architects 94447 Plattling Robert-Bosch-Straße 2 Tel.+49 (0) 99 31 9 50-229 Fax +49 (0) 99 31 69-236 e-mail: ibc@interpane.com Austria: 7111 Parndorf Heidegasse 45 Tel.+43 (0) 21 66 23 25-0 Fax +43 (0) 21 66 23 25-30 e-mail: parndorf@interpane.com France: 67720 Hoerdt 2, rue de l Industrie Tel.+33 (0) 3 88 64 59 59 Fax +33 (0) 3 88 51 39 90 e-mail: hoerdt@interpane.com