Behaviour of FRP wrapped circular reinforced concrete columns

Similar documents
CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

Behaviour of FRP wrapped circular concrete columns under eccentric loading

Influence of Longitudinal FRP Straps on the Behaviour of Circularised and FRP Wrapped Square Hollow RC Concrete Specimens

Behaviour of FRP strengthened concrete columns under eccentric compression loading

Behaviour of Modified RC Columns Retrofitted with CFRP

Behaviour of GFRP tube reinforced concrete columns under eccentric loading

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Maximum usable strain of FRP-confined concrete cylinders

FRP-confined concrete-encased cross-shaped steel columns: stub column tests

A STUDY ON STRENGTHENING OF HOLLOW STEEL SECTION BY USING CFRP AND AFRP

Effect of ply configuration on hollow square reinforced concrete columns confined with Carbon fibre-reinforced polymer (CFRP)

Moment curvature analysis of concrete flexural members confined with CFRP grids

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

CONCRETE-FILLED SQUARE FRP TUBES UNDER AXIAL COMPRESSION

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Confining concrete cover of GFRP tube reinforced concrete columns with polymer grids

Behaviour of carbon fibre-reinforced polymerconfined hollow circular concrete columns with inner polyvinyl chloride tube

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Regression Model for Predicting Study Parameters of GFRP Strengthened Corrosion Damaged RC Columns P.R.Dhevasenaa, K.Suguna and P.N.

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

FRP-Confinement of Hollow Concrete Cylinders and Prisms

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Behavior of FRP confined ultrahigh-strength concrete columns under axial compression: An experimental study

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

University of Wollongong. Research Online

Modeling aspects concerning the axial behavior of RC columns

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

FIBRE COMPOSITES PILE REHABILITATION AND CONCRETE FORMWORK JACKET CONCEPT DEVELOPMENT AND FINITE ELEMENT ANALYSIS

Experimental Study of Concrete-filled Carbon Fiber Reinforced Polymer Tube with Internal Reinforcement under Axially Loading

Hybrid double-skin tubular columns with a large rupture strain FRP outer tube: stub column tests

Seismic Behavior of Low Strength RC Columns with Corroded Plain Reinforcing Bars

Structural behaviour of recycled concrete filled steel tube columns strengthened with CFRP sheets under axial loading

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

AFRP retrofitting of RC structures in Japan

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

Axial load-bending moment diagrams of GFRP reinforced columns and GFRP encased square columns

Behaviour of hollow core square reinforced concrete columns wrapped with CFRP with different fibre orientations

USE OF FRP COMPOSITES FOR STRENGTHENING OF RCC COLUMNS

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

406 A.R. Khaloo and A. Esmaili This method does not enhance column moment capacity and stiness signicantly. Therefore, additional earthquake forces in

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete

Use of CFRP in Confining High Strength Concrete Columns Subject to Axial Loading

EFFECT OF CONFINEMENT ON THE INTERACTION DIAGRAMS FOR RC SECTIONS WITH CFRP GRIDS AND WRAPS

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Investigation of fibre reinforcing the cover of concrete columns

Hybrid FRP-concrete-steel double-skin tubular columns: Cyclic axial compression tests

BEHAVIOUR OF SPIRAL REINFORCED LIGHTWEIGHT AGGREGATE CONCRETE COLUMNS

BEHAVIOR OF REINFORCED CONCRETE ONE-WAY SLABS STRENGTHENED BY CFRP SHEETS IN FLEXURAL ZONE

Experimental tests on RC hollow columns strengthened with FRPs

Confined High Strength Concrete Columns: An Experimental Study

FRP-strengthened RC Structures

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

Flexural retrofitting of reinforced concrete bridge pier type cross-sections with carbon fiber reinforcing plastics

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

Numerical Study on Behaviour of Concrete Filled Tubes (CFT) under Static Load

Flexural ductility of helically confined HSC beams

BEHAVIOUR OF HIGH STRENGTH CONCRETE COLUMNS REINFORCED WITH STEEL FIBRES UNDER DIFFERENT ECCENTRIC LOADS

A Comparative Study On CFRP Confined RC Capsule Column With Varying Reinforcement Ratio

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

EXPERIMENTAL EVALUATION OF FULL-SCALE FRP-CONFINED REINFORCED CONCRETE COLUMNS

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

Enhancing the Compressive Strength of Square Cross Sectional Column Using FRP Material

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

Jagannathan Saravanan et al IJCSET January 2012 Vol 2, Issue 1,

Analysis of Concrete Filled Double Skin Steel Tube (CFDST) column with CFRP wrapping

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Experimental study on the effectiveness of CFRP strengthening of shear-deficient reinforced concrete beams under impact loading

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

TENSION AND COMPRESSION TESTING OF FIBRE REINFORCED POLYMER (FRP) BARS

FRP STRENGTHENING OF 60 YEAR OLD PRE-STRESSED CONCRETE BRIDGE DECK UNITS

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Code No: R Set No. 1

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

Tension and compression testing of fibre reinforced polymer (FRP) bars

Numerical Modelling of Concrete Filled Frp Tubes Subjected Under Impact Loading

Analytical study of a 2-span reinforced concrete beam strengthened with fibre reinforced polymer

Experimental Study of Rectangular RC Columns Strengthened with CFRP Composites under Eccentric Loading

Axial and flexural behavior of unreinforced and FRP bar reinforced circular concrete filled FRP tube columns

Response of columns and joints with spiral shear reinforcement

Comparisons to Tests on Reinforced Concrete Members

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

GFRP retrofitted RC frames with columns subjected to high axial stresses

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

COLUMNS. Classification of columns:

Experimental Study on RC Columns Wrapped With Hybrid FRP Sheets

AN ANALYSIS OF MEMBRANE ACTION IN ONE-WAY CONCRETE MEMBERS EXTERNALLY BONDED WITH FRP

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

RESILIENT INFRASTRUCTURE June 1 4, 2016

FRP Tubes Filled With Concrete and Subjected to Axial Loads, Bending and Combined Loads

SHAKING TABLE TEST OF LARGE SCALE NONDUCTILE RC FRAMES RETROFITTED WITH FRP COMPOSITES

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

Mechanical Behaviour of Concrete Beams Reinforced with CFRP U- Channels

Analysis of Concrete Filled Double Skin Steel Tube (CFDST) column with FRP wrapping

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

EXPERIMENTAL STUDY ON FRP-PVC CONFINED CIRCULAR COLUMNS

10.5 ECCENTRICALLY LOADED COLUMNS: AXIAL LOAD AND BENDING.

Transcription:

Challenges, Opportunities and Solutions in Structural Engineering and Construction Ghafoori (ed.) 2010 Taylor & Francis Group, London, ISBN 978-0-415-56809-8 Behaviour of FRP wrapped circular reinforced concrete columns M.N.S. Hadi & V. Yazici School of Civil, Mining and Environmental Engineering, University of Wollongong, Australia ABSTRACT: Columns are generally under bending moment and axial load at the same time. Studies done on solid concrete columns under concentric loading have shown that FRP wrapping improves the strength and ductility of columns. This paper presents results of testing 16 reinforced concrete columns, 8 solid and 8 hollow, under different eccentricities. The height and the diameter of the columns were 925 mm and 205 mm respectively. Each group of sample columns was divided into two sub-groups. The first sub-groups served as a reference and did not have any external FRP wrapping. The second sub-groups were wrapped with three layers of Carbon FRP in the hoop direction. Sample columns were tested under concentric, eccentric (25 m and 50 mm) and pure bending loading. Axial load bending moment interaction diagrams were constructed for each of the sub-groups. The effectiveness of CFRP wrapping on solid and hollow sample was compared and discussed. 1 INTRODUCTION Increasing costs of building materials has created a new trend of retrofitting the existing structural members which would otherwise be insufficient due to increased demand from the structure, adopting more stringent design codes, or deterioration of structural members in hostile environmental conditions. Fiber reinforced polymer (FRP) sheet wrapping has been a common method of strengthening reinforced concrete columns for the last two decades. This new material s resistance to corrosion, excellent durability to harsh conditions, high tensile strength to weight ratio and ease of installation to existing structural members have made it a popular strengthening material. There have been various studies investigating the behaviour of FRP wrapped solid columns such as capacity or ductility increase. However, behaviuor of FRP wrapped hollow columns has been less investigated though their frequent use as structural members such as bridge piers. This paper investigates the effect of Carbon-FRP (CFRP) wrapping on both reinforced solid and hollow core concrete columns under different loading conditions. 2 LITERATURE REVIEW Steel jacketing is assumed to provide a constant confinement to the columns after the yield strain. There are a number of steel confined concrete stress-strain models and most of them are based on Richart et al. s study (1928). Since the FRP materials exhibit a linear stress-strain behaviour under tensile loads up to the failure, the confinement stress, f l, they provide to the columns is highly dependant on the strain level of FRP wrapping. Models proposed by Samaan et al. (1998), Spoelstra & Monti (1999), Toutanji (1999) and Teng et al. (2002) have shown that previously defined stress-strain models for steel confined concrete such as Mander et al. (1988) cannot be used for FRP confined concrete. Although none of FRP confined concrete stress-strain models has been accepted as a standard model worldwide, various studies such as), Hadi (2007a, b) have shown that both strength and ductility of solid concrete columns are substantially improved after FRP wrapping. Hollow core columns are generally preferred to solid columns to reduce the self weight and cost of the structures. In spite of their widespread use, even modern design codes do not specify a special design procedure for hollow core columns. 3 THEORETICAL CONSIDERATIONS Although the only apparent difference from an FRP wrapped solid column seems to be the hollow portion in the center, confinement mechanism of an FRP wrapped hollow core column under an axial load is quite different. For an axially loaded column, when FRP wrapping reaches its maximum tensile strength, f frp, the confinement stress reaches its maximum value, f l (Figure 1). The maximum confinement stress provided by FRP wrapping, f l, can be calculated using the Equations 1 and 2 for the solid and hollow core columns, respectively, derived from the equilibrium of forces acting on the half-cut cross-sections shown in Figure 1. f l,solid = 2f frpt frp D (1) 215

Figure 1. Forces acting on half cut cross sections of a) solid column, b) hollow core column under axial loading. f l,hollow = 2f frpt frp (D d) (2) where t frp is the total thickness of FRP wrapping, D is the outer diameter of solid and hollow core column, and d is the hollow core diameter. Equations 1 and 2 imply that, for the same D, f frp, and t frp ; f l, is larger on the hollow core columns because of the hollow part. However, for solid columns f l results in a triaxial stress state on any concrete element within the column whereas this confinement creates only a biaxial state of stress on a concrete element within a hollow column resulting in less capacity increase (Zahn et al. 1990; Yazici & Hadi 2008). 4 EXPERIMENTAL STUDY The experimental part of this study was conducted at the laboratories of the School of Civil, Mining and Environmental Engineering at the University of Wollongong and involved testing of 16 circular reinforced concrete columns, half solid and half hollow core. The geometry of sample columns and testing conditions are given in Figure 2 and Table 1, respectively. The concrete used to cast the sample columns had a 28 day compressive strength of 60 MPa. All specimens were internally reinforced with the same amount of steel reinforcement. Longitudinal steel reinforcement consisted of evenly distributed six N12 (12 mm diameter deformed bar) bars and tied inside a helical steel reinforcement. The helical reinforcement was made of R10 bars (10 mm diameter plain bar) with a 50 mm pitch. The steel reinforcement was placed into the column moulds with 20 mm clearance to the outer moulds (Fig. 2). A summary of material testing is given in Table 2. The f l values were calculated using Equations 1 and 2 for groups of SF and HF sample columns respectively. Confinement due to helical steel was ignored. A PVC pipe having an inner diameter of 205 mm was used as the outer mould for both solid and hollow core columns. A 56 mm outer diameter PVC pipe was used to form the hollow part of Groups H and HF. After Figure 2. a) General geometry of column samples, b) Crosssection of solid column samples, c) Cross section of hollow core column samples. Table 1. Geometry of sample columns and testing conditions. Inner Internal Wrap- Test Speci- Dia- dia- rein- ping eccenmen meter Height meter force- configu- tricity code (mm) (mm) (mm) ment ration (mm) S0 205 925 Yes None 0 S25 25 S50 50 SB Bending SF0 205 925 Yes Three layers 0 SF25 of carbon 25 SF50 FRP in hoop 50 SFB direction Bending H0 205 925 56 Yes None 0 H25 25 H50 50 HB Bending HF0 205 925 56 Yes Three layers 0 HF25 of carbon 25 HF50 FRP in hoop 50 HFB direction Bending setting of the concrete, the outer moulds were removed using the previously cut joints on the PVC pipe, and the inner PVC pipes for hollow core sample columns were pulled out by means of a hydraulic jack. Epoxy was used to adhere three layers of Carbon FRP sheet on to the surface of sample column Groups SF and HF with fibres in the hoop direction with 100 mm overlap and one CFRP layer onto another (Figure 3). The combined tensile strengh of three layers of CFRP was tested to have 920 MPa using the standard ASTM 3039-2006. 216

Table 2. Summary of material tests and confinement stresses due to Carbon FRP wrapping. Concrete Longitudinal Helical Combined Maximum confinement Sample strength, steel strength steel strength tensile strength Combined thickness stress due to CFRP Group f co (MPa) (MPa) of CFRP, ff rp, (MPa) of CFRP, tf rp, (mm) wrapping, f l, (MPa) S 60 558.6 366.9 SF 60 558.6 366.9 920 1.60 14.4 H 60 558.6 366.9 HF 60 558.6 366.9 920 1.60 19.8 Figure 3. CFRP wrapping configurations for Sample Groups SF and HF. Figure 5. Four-point loading apparatus. Figure 4. a) Loading Head, b) Knife edge. One specimen from each sub-group (Specimens S0, SF0, H0, HF0) was tested to failure under concentric loading, the next two specimens were tested under 25 mm (S25, SF25, H25, and HF25) and 50 mm (S50, SF50, H50, and HF50) eccentric loading. The final specimen of each sub-group (SB, SFB, HB, and HFB) was tested under pure bending. 25 mm and 50 mm eccentric loadings were applied to the columns by means of especially designed and manufactured loading heads and knife edges as shown in Figure 4. Pure bending load was applied to specimens (in fact beams) SB, SFB, HB, and HFB by means of a four point loading apparatus as shown in Figure 5. For concentric and eccentric loading the load, P, that was applied to the columns was measured by the internal load cell of the loading machine. For the axially loaded specimens, the axial deformations ( ) ofthe Figure 6. samples. Figure 7. Measurements taken for axially loaded column Measurements for bending. columns were monitored by an LVDT attached to the moving (lower) plate of the loading device. Lateral deformations of the specimens (δ) were monitored at the mid height of columns using a laser displacement sensor (Figure 6). 217

For pure bending loading, the flexural load, P, and corresponding mid-span bending deformation was measured (Figure 7). Bending deformation was measured by an LVDT attached to the lower plate of loading device. A hole was formed in the middle of lower part of four point loading device to let the laser through. 5 RESULTS All specimens were tested to failure. For 25 mm and 50 mm eccentrically loaded columns, bending moment capacities are calculated by multiplying the maximum load capacity (P max ) and the eccentricity (e). Bending moment capacities including the secondary moments (M II ) were also calculated as follows; M II = P max (e + δ) (3) Where P max = max axial load, e = eccentricity, and δ = lateral deflection at maximum load. Table 3 shows a summary of testing results for the column specimens tested under concentric and eccentric loading. Table 4 shows the test results for sample columns tested under four point loading (pure bending). Bending moment for sample columns tested under four point loading regime was calculated using Equation 4 derived from the moment equation for simply supported beams. Figure 8 9 shows the axial load-deformation graphs of solid sample columns, namely sub-groups S and SF, respectively. Figure 10 shows flexural load-midspan deformation of sample columns SB and SFB. Figure 11 12 shows the axial load-deformation graphs of hollow core sample columns, namely subgroups H and HF, respectively. Table 4. Summary of results for pure bending. Midspan Max. Load, Deformation at M (Bending Specimen P max (kn) P max, δ, (mm) Moment) (knm) SB 288.0 9.59 40.32 SFB 370.1 26.47 51.82 HB 207.2 23.04 29.01 HFB 327.7 35.65 45.88 M max = 0.280P max 2 (4) where 0.280 is the distance between one lower support to the nearest upper loading point, and P max is the maximum flexural load applied to the column sample. Figure 8. Load-deformation graph for solid columns without CFRP wrapping. Table 3. Summary of test results for concentric and eccentric loading. Axial Midheight Axial Bending Eccen- deformation horizontal defor- deformation Horizontal Moment M II = Max. Load, tricity at P max, mation at max. at failure deformation at M I = P max e P max (e + δ) P max (kn) e, (mm), (mm) load, δ, (mm) (mm) failure (mm) (knm) (knm) S0 2802.3 0 5.63 11.80 S25 1440.4 25 6.02 5.80 17.02 53.04 36.01 44.36 S50 1134.4 50 4.69 4.31 4.71 4.94 56.72 61.61 SF0 4504.5 0 9.70 12.95 SF25 3069.2 25 16.10 14.32 24.79 72.26 76.73 120.68 SF50 1527.0 50 8.62 12.14 17.11 63.02 76.35 84.50 H0 2145.4 0 4.50 29.04 H25 1699.5 25 7.03 4.17 21.61 36.51 42.49 49.52 H50 915.7 50 4.38 5.34 13.30 27.20 45.78 50.67 HF0 3237.7 0 12.54 29.90 HF25 1785.0 25 7.18 7.64 15.40 53.06 44.63 58.26 HF50 1119.3 50 8.98 12.48 19.18 53.36 55.97 69.93 218

Figure 9. columns. Load-deformation graph for CFRP wrapped solid Figure 12. Load-deformation graph for CFRP wrapped hollow core columns Figure 10. Flexural load-midspan deformation of sample columns SB and SFB. Figure 13. Flexural load-midspan deformation of sample columns HB and HFB. Figure 11. Load-deformation graph for hollow core columns without CFRP wrapping. Figure 13 shows flexural load-midspan deformation of sample columns HB and HFB. Axial load-bending moment diagrams (P-M) of all sub-groups are shown in a single chart in Figure 14. Figure 14. columns. P-M diagrams of all sub-groups of sample 6 DISCUSSION OF RESULTS Increase in the axial load carrying capacity due to CFRP wrapping for concentric loading was larger for solid column sample as expected (60.7% and 50.9% for sample columns SF0 and HF0, respectively). 219

For 25 mm eccentric loading, solid column sample SF25 exhibited an axial load capacity increase of 113.1% compared to S25 which implied a possible error in testing as a less capacity increase was expected as the eccentricity of loading increases. For the same eccentricity (25 mm), the hollow core column sample HF25 exhibited only a 5% axial load capacity increase compared to H25. For 50 mm eccentricity, SF50 exhibited an axial load carrying capacity increase of 34.6% compared to S50. The increase was only 22.2% for HF50 compared to H50. For pure bending loading, the increase in flexural load carrying capacity was more in hollow core column samples. The flexural load carrying capacity was increased by 58.2% for HFB compared to HB, whereas 28.5% for SFB compared to SB. Axial deformation capacities corrsponding to P max of hollow sample columns without CFRP reinforcement tend to be larger than that of solid columns without reinforcement. Likewise, the increase in the axial deformation capacities corresponding to P max of CFRP wrapped hollow core columns are generally higher than that of CFRP wrapped solid columns for the same level of eccentricity. However, horizontal deformation capacities of solid columns (wrapped or not), are generally higher than hollow core columns for the same level of eccentricity and CFRP wrapping configuration. 7 CONCLUSIONS Testing results revealed that CFRP wrapping increased axial load carrying capacity, axial and horizontal deformation capacities of both solid and hollow core reinforced columns at the same time. However, the increase was more substantial for solid columns. The column specimens were designed as short columns, but after CFRP wrapping horizontal de-formation capacity increased in such amounts that the secondary moments became considerable. In other words, the column specimens began to behave like slender columns under eccentric loads. This problem should be considered when the columns are being strengthened with FRP wrapping especially for the columns which will also be subjected to eccentric loads unavoidably. REFERENCES ASTM 3039-2006, Standard test method for tensile properties of polymer matrix composite Materials. Hadi, M.N.S. 2007a. Behaviour of FRP strengthened concrete columns under eccentric compression loading. Composite Structures 77(1), 92 96. Hadi, M.N.S. 2007b. The behaviour of FRP wrapped HSC columns under different eccentric loads. Composite Structures 78(1): 560 566. Mander, B.J., Priestley, M.J.N. & Park, R. 1988, Theoretical stress-strain model for confined concrete, Journal of Structural Engineering, ASCE 114(8),1804 1825. Samaan, M., Mirmiran, A. & Shahawy, M. 1998. Model of concrete confined by fiber composites. Journal of Structural Engineering, ASCE 124(9): 1025 1031. Spoelstra, M.R. & Monti, G. 1999. FRP-confined concrete model. Journal of Composites for Construction, ASCE 3(3): 143 150. Richart, F.E., Brandtzaeg, A. & Brown, R.L., A Study of the Failure of Concrete under Combined Compressive Stresses. Bulletin 185. University of Illinois Engineering Experimental Station, Champaign, Ill, 1928. Teng, J.G., Chen, J.F., Smith, S.T. & Lam, L. 2002. FRP- Strengthened RC structures. John Wiley & Sons Ltd., West Sussex, England. Toutanji, H.A. 1999. Stress-strain characteristics of concrete columns externally confined with advanced fiber composite sheets. ACI Materials Journal 96(3): 397 404. Yazici, V. & Hadi, M.N.S., 2008, Interaction diagrams for FRP wrapped circular hollow columns, Proc.The 20th Australasian Conference on the mechanics of structures and materials, Toowoomba, Australia, 2 5-December 2008, London: Balkema. 220