GASCOGNE Implementation Guide

Similar documents
ECAILLE Implementation Guide

MASCARET Implementation Guide

ST PRODUCTS Implementation Guide

OXYGEN Implementation Guide

CASSETTE SP Implementation guide

CASSETTE BS Specification book

Kingspan Day-Lite Klick

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

Exterior System installation instructions

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

Production Technology

RUUKKI FORMA DESIGN INSTRUCTION

Arcwall. Rain Screen Wall System

SECTION EXTERIOR GRILLS AND SCREENS

Arcwall. Rain Screen Wall System

Architectural Wall Products Guide Specifications

Opus Interior wall facing system in zinc.

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

Corium Brick Rainscreen System Specifications

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

For more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding

SECTION COLD-FORMED METAL TRUSSES

Aquaroc Fibre Cement Board

RUUKKI FAÇADE SYSTEMS

GA APPLICATION OF GYPSUM SHEATHING

SECTION STAINLESS STEEL WALL PANELS

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Promistyl 3005T - roofing

BEARING METAL STUD FRAMING

RAINSCREEN CLADDING. Bespoke secret fix Rainscreen cladding system available in range of materials and finishes. Delivering your design

Resysta Wall Cladding Installation Guidelines

Guideline Specifications

ThermaSteel Corporation ASSEMBLY MANUAL

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

Samrat External Wall Cladding.

Fundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Bioclimatic Pergola with ajustable blades

Vertigo Cladding Board

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

Sculpted 3D Minimal. Rain Screen Wall System

danpalon glazing system - housing Product BRANZ APPRAISAL No. 526 (2006) Scope Everlight NZ Ltd P O Box Whenuapai Waitakere 0662 Auckland

SYSTEM W-H 1100 Wall cladding. Metal product

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

Planning and installation instructions

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

SRP-AirOutshield UV Issued:

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

EQUITONE is a material supplier. Installation Contractors shall be trained and approved by EQUITONE.

Architectural Roof Products Guide Specifications

SECTION FIBER CEMENT SIDING. A. Furnish and install CERACLAD fiber cement rain screen siding system.

Sandwich panel SPA Product description

A. Meet at Project site <insert number> days before starting installation.

SECTION SECTIONAL OVERHEAD DOORS

Product Guide Specification

Ameriplate. Rain Screen Wall System

Siding Installation Manual for: Color Natura Rustica Rivets

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene

SSL-175. Specifications

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

Gold Bond BRAND Gypsum Sheathing

A. Product Data: For each type of cold-formed steel framing product and accessory.

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

H92 RAINSCREEN CLADDING

ZINC. Product Data Sheet

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

70S - 132S SUN LOUVRE. Sun Control Systems

CERTIFICATE No VTT-C Date of issue

Table of Contents. Certificates and approvals Colour palette...52

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

Specifications for FL-100 Soffit Panel

Flotation Docking Systems, Inc.

Omniplate Barrier Wall System

Installation guidelines System: Cofraplus 220

Architectural Roof Products Guide Specifications

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION COLD-FORMED METAL FRAMING

HEAVY STEEL CONSTRUCTION

OS-ALD ACOUSTIC LOUVERS

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Klick KS500 DLKK

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

Series 3000 Pocket Doors

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM

SECTION METAL ROOF PANELS

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Transcription:

GASCOGNE Implementation Guide Edition of August 21st, 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr

SYSTEM DESCRIPTION The Gascogne panel is a piece of siding made of stainless or pre-coated galvanized steel with a nominal thickness of at least 1 mm. These panels fit together by their longitudinal edges, and the attachments are no longer visible after installation.(technical drawings nb.1&2+5) This panel is notably used for add-on siding, designed with a vertical or horizontal arrangement of joist between the panels. The macimum recommended span is 1.50 m between supports. This product can be used on new or renovated public or private buildings used for commercial or lodging purposes.(technical drawings nb.3&4) Gascogne siding does not participate in the general stability of the building (no wind bracing or anti-buckling functions). The support wall must provide the strength functions and stability of the façade and meet requirements in the matter of air permeability. TECHNICAL CHARACTERISTICS Manufacture: by bending (technical drawings nb.1 to 4) Useful width : 300 mm ± 1 mm. Nominal height : 75 mm +0 mm/-1 mm Length 1000 mm 5000 mm maximum +0mm/-3 mm MATERIALS Thickness (mm) Steel Stainless Steel 1 1 Grade Standard S320 GD + Z 225 or Z 275 + primary NF EN 10326 P 34310 X5 Cr Ni 18-10 or X2 Cr Ni 17-12-2 NF EN 10088-2 Protection Quality pre-coating colorissime ARVAL Post-coating by polyester dusting (mini 60µm depending on color) Possibility pre-coated Colorinox PVDF 36 µm Standard XP P34301 P 24351 P 34 301 PMA should be consulted of the feasibility of various colors and surface appearances: Pre-coated and pearly steel: Colorissime color chart by Arval, Steel post-coated by dusting: RAL color chart.

FINISHING ELEMENTS They are manufactured from th same plates (same thickness, same quality of material) as the panels in a maximum lengths of 6 m. Various connections (technical drawings nb. 28 to 31) Outside and Re-entrant corners (technical drawings nb.16 to 24) Acroterion crown (technical drawings nb. 6 to 11 ) Flaps (technical drawings nb. 12 to 15 ) Window frames (technical drawings nb.25 to 27 ) ASSEMBLY PRINCIPLE GASCOGNE panels are designed to be installed on a ruled secondary frame allowing a ventilated fiom of air to flow between the panels and the support wall or possible thermal insulation. This frame is to satisfy the requirements of C.S.T.B. Book no. 3194 JanuaryFebruary 2000 - «General conditions for design and implementation of the metal framing and thermal insulation of add-on siding». This secondary frame is a construction element by itself and is not an integral part of the Gascogne process. Nevertheless, proper execution is a condition for the final result, notably as concerns the appearance of the facing. The presence of a secondary framing is systematically required, including in the case of double-skin sinding with metallic plates in internal skin. It serves as bearing and attachment support for the siding. PARTICULAR ARRANGEMENTS FOR THE FRAME No frame alignment of flatness erros can be compensated by the GASCOGNE panels themsleves. The allowable loads and spans of the GASCOGNE panels under normal climatic conditions have been determined by tests considering the following criteria :. Deflections of at most 1/200th of the span for the longitudinal edges. Safety coefficient with respect to ruin greater than 2 For aesthetic considerations, it is also advised to limit the spans to 1.5 m. GASCOGNE panels are installed and attached on metal rails with the following characteristics:. Bearing width of at least 40 mm. The thickness of the secondary frame sections must notably allow construction of assemblies with a minimum characteristic strenght of 300 dan. Normal wind loads allowable on GASCOGNE panels in 10/10ths steel, in dan/m², Pressure & Vaccuum Simple span 2 supports Vacuum Pressure 218 Span in (m) Continuity 3 supports or more Pressure Vacuum 1.50 250 205 1.60 240 193 1.70 230 182 1.80 215 172 1.90 202 115 164 2.00 190 115

Tests carries out on pre-coated steel panels (S320 GD + Z 225) Weight : 16,5 kg/m² For panels in stainless steel, a 20 mm pincer can achieve allowable loads comparable to those of panels in pre-coated steel. CONDITIONING AND TRANSPORT A delivery note is glued to each package stating: Customer order reference, Batch reference Customer name Type of product Facing thickness Bundle content (number and length) Color reference of pre-coated plates. GASCOGNE panels are packed on the production line. The weight of the bundles may in no case exceed 2.5 tons. GASCOGNE panels and their accessories are to be transported under conditions that preserve the integrity of the characteristics (shimmed up packages, carefully stacked and strapped, tarpaulin-covered trucks). ORGANISATION The PMA company is the product manufacturer and does not install the product. GASCOGNE panels are to be installed by constractors having the required professional qualifications. Design and studies prior to executing the facade are not incumbent on the maker PMA nor on the distributor companies. On request, PMA can provide technical assistance. The purpose of the present specification is not to give details on all points of implementation but to state the main technical definitions of the panels and their particular characteristics. To help in the study of the facades, it is complemented in the appendix with particular design suggestions and finishing elements. HANDLING, STORAGE AND MAINTENANCE Handling operations are carried out in consideration of the particular features of the products. They are to be handled vertically on edge. The panels are stored in bundles, slightly inclined in the longitudinal direction on a flat surface, without stacking more than two packags. Storage time on the work site is to be reduced to the minimum. The essential precaution consists in avoiding water from entering by runoff or condensation between the panels. Store sheltered from sunlight. The peel-off protective film covering GASCOGNE panels is to be removed as work advances, at the latest 15 days after shipment.

Metallic facades have to be normally maintainted in accordance with the prescriptions of the Professional Rules for Metallic Siding (article 4-2-91 exterior maintenance). Although naturally cleanable by runoff of rainwater, if needed, they can be cleaned periodically with household detergent, without chlorine added, with no use of abrasive or solvent, followed by rinsing with fresh water. Mainteance notably consists of: Eliminating various vegetation (such as moss) and any incompatible matter that might be deposited on the facing surface. Repair of any localized degradation as soon as detected, such as incipient corrosion caused, for example, by exterior deterioration actions. Cutting and drilling Custom manufacture makes it possible to limit the cutting on the work site. As required, cutting operations on site are performed using the appropriate equipment (jigsaw, nibbler, fine-tooth saw). It is strictly prohibited to use a grinder wheel. Watch out to avoid hot particles from being incrusted on the coating. All dirt (filings, drilling chips, etc...) are to be eliminated immediately. DRAWINGS OF DETAILS OF PRINCIPLE The following drawings are examples of how singular point of GASCOGNE panels are treated. Any other solutions can be considered and studied by the installing contractor in consideration of the specific characteristics of the products.

For any further information, please consult us: IMPORTANT The content of this document is based on data relative to construction and to material properties. It is designed to assit PMA customers in implementing its products. Based on the construction processes and methods known at the time of its publication, this Implementation Guide cannot be considered final and may be revised and/or modified at any time. In case of doubt or difficulty, the user is asked to consult PMA before continuing his project.

TECHNICAL DRAWINGS Useful width 300 mm GASCOGNE panel steel 10/10 nb.1 GASCOGNE panel vertical section nb.2

GASCOGNE double-skin panel nb.3 GASCOGNE add-on siding nb.4

Sense of installation Attachment detail vertical section nb.5 Acroterion Crown nb.6

Acroterion crown Detail nb.7 en ml u m xi Ma gth 6 m 0 00 m Acroterion X, Y and Z as per request nb.8 Fish plate Thickness 1mm nb.9

Acroterion for double skin cladding nb.10 Acroterion for add-on siding nb.11

Flap vertical section ne Gascog Ruled secondary frame panel As requested Perforated flap Thickness 1mm Begining pin Thcikness 1mm nb.12 Perforated flap x ma h t ng Le m 0m 0 0.6 th ng Le x ma mm 0 00.6 Perforing following hight of the facade to be ventilated nb.13

Flap for double-skin cladding nb.14 Flap for add-on siding nb.15

Outside right corner nb.16 nb.17 nb.18 nb.19

Right outside corner nb.20 Right entrant corner nb.21

Right entrant corner Horizontal section Right entrant corner Gascogne panel nb.22 Splice piece nb.23 nb.24

Window frames nb.25 Window frames horizontal section Window frames vertical section Secondary ruled frame Gascogne panel Perforated lintel (ventilation+evacuation of moisture) Sealant Jamb against riser Jamb against riser Window rest flap Ventilation Gascogne panel nb.26 nb.27

Vertical divisor nb.28 Vertical divisor Thickness 1mm nb.29 Acroterion crown vertical section Lenght 6000 mm Vertical Divisor Acroterion Divisor X as the acroterion covers the divisor nb.30 Attention: For a use of the divisor the width of the acroterion (X) must be sufficient to cover the high part of the divisor. nb.31