Building Code 8 th Edition

Similar documents
Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

CODE ANALYSIS REPORT SECOND FLOOR

PRESCRIPTIVE COMPLIANCE METHOD

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

SUMMARY OF FIRE SPRINKLER REQUIREMENTS FOR ALTERATIONS TO EXISTING BUILDINGS 2015 I-Codes

INTERNATIONAL EXISTING BUILDING CODE

Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts

9/19/2018. Session: 2018 IEBC Essentials - History

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code)

IEBC: How to Address Challenging Code Issues; and, Let s Find Answers

LIFE SAFETY 101. Architecture Interior Design Planning Sustainable Design

780 CMR CHAPTER 34 EXISTING BUILDINGS STRUCTURES

The Building Codes A.R.E. Building Design and Construction Exam Prep

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

A minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include:

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

What is a Won-Door FireGuard Door?

5/15/2013. Approved Course Title 2010 Existing Building Code Chapters Florida Building Code, Existing Building. Chapters

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

Application for a Building Permit Commercial Work Building Commissioner 37 Main Street Charlton, MA

Code Compliance Alternatives for Historic Buildings

LEAD DESIGN PROFESSIONAL:

5/9/ Florida Building Code, Existing Building. Chapters Approved Course Title 2010 Existing Building Code Chapters

PRESCRIPTIVE COMPLIANCE METHOD

2012 IEBC Fundamentals 12/11/2017. Copyright 2012 International Code Council 1

2015 IBC Exit Systems

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

COMMERCIAL PLAN SUBMITTAL GUIDELINES JAN 2018

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

City of Roanoke. Commercial Permit Submittal Guidelines

Accessible Means Of Egress

2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC )

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

Appendix M : Life Safety and Fire Protection Assessment

The International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

NOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.

Civil District Court Parish of New Orleans. Image Courtesy of EDR MA. Renovation & Utilization Feasibility

Architect and Engineer: Friar Associates inc.

2006/2007 INTERNATIONAL EXISTING BUILDING CODE DEVELOPMENT COMMITTEE

2012 IBC Exit Systems

City of Montevallo Commercial Construction Permitting. August 2016 Revised 8/12/16

How to Prepare Your LSE Report

IBC MEANS OF EGRESS. Code Change No: E5-07/08. Original Proposal

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

PLAN SUBMITTAL REQUIREMENTS - ARCHITECTURAL

South Windsor Public Schools. Elementary School Facilities Existing Condition Survey & Master Plan. Executive Summary 10/22/13

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

MVRTA Newburyport Intermodal Parking Facility Newburyport, Massachusetts

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

Path of Travel Upgrade Requirements

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

Plan Check No. A. ELEVATORS

IR 11B-10 SCOPING AND PATH OF TRAVEL UPGRADE REQUIREMENTS FOR FACILITY ALTERATION, ADDITION A ND STRUCTURAL REPAIR PROJECTS

101.1 Title. These regulations shall be known as the Existing Building Code of Massachusetts, hereinafter referred to as this code.

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Alterations, disproportionality, and the 20% rule

City of Tacoma Planning and Development Services

Application for Certificate of Occupancy Procedure for Existing Commercial & Residential 4 (+) Family Buildings

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS

Applying the Building Code During Design

E?? , , , , , , , , , , , , Table ,

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

STATE UNIVERSITY CONSTRUCTION FUND

Q. Do residential and historical buildings that are going to be protected with sprinklers need to conduct an LSE?

635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE

5. Project Construction Cost (Provide cost for new construction, the addition or the alteration): $ Estimated Project Budget is $125,000.

Huntington Building Inspection

Module 8: Ontario Building Code Fire and Spatial Separations

ACCESSIBILITY CHECKLIST

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Thule Prototype BIM Manual for Dormitories. February 5, 2010

AN ORDINANCE AMENDING TITLE 10 (BUILDING REGULATIONS)

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

Practice Points NUMBER

2) These Standards are available on the University s website at:

2015 IBC Special Building Types and Features IBC Special Building Types and Features. Copyright 2016 International Code Council 1

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

Access Upgrade Compliance Package (For Existing Commercial Buildings only)

INTERNATIONAL EXISTING BUILDING CODE

HOUSING CONVERSION Guidelines for the conversion of a house to commercial use.

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks

CTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1

Applying Energy Code to Existing Buildings

Fill out all sections or mark with N/A (not applicable)

2007 Title 24 Accessibility Code Updates and ADA Issues

Save the Places that Matter. Build Community. Live Better. Building Code Officials Are Part of Your Revitalization Team

CTC Meeting #28 September 16-17, 2013 IBC Coordination with ADAAG

Design and Construction AN ISO 9001:2008 CERTIFIED ORGANIZATION

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

Transcription:

Massachusetts State Building Code 8 th Edition Kevin S. Hastings, P.E., LEED AP R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com

RW R.W. Sullivan Engineering (RWS) was established in 1945 and currently has 90 employees. RWS is a full service engineering firm offering integrated services in the following disciplines: HVAC Electrical Plumbing Fire Protection Code

Agenda Existing Buildings Introduction to IEBC MA Sprinkler Law Accessibility Codes

Applicable Codes in New England State New Existing NFPA 101 Connecticut 2003 IBC 2006 IEBC Hospitals & Existing Only Maine 2009 IBC 2009 IEBC Yes Massachusetts 2009 IBC 2009 IEBC HospitalsOnly New Hampshire 2009 IBC 2009 IBC Chapter 34 Yes Rhode Island 2009 IBC 2009 IBC Chapter 34 or RI Rehab Code Yes Vermont 2006 IBC 2006 IBC Chapter 34 Yes * Also see state amendments.

Existing Building Definition of an Existing Building: A building erected prior to the date of adoption of the appropriate code, or one for which a legal building permit has been issued. (IEBC 202) No 5 year rule.

Three Compliance Methods Chapters Subjects 1-2 Administrative Requirement and Definitions 3 Prescriptive e Compliance Method 4-12 Work Area Compliance Method 4 Classification of Work 5 Repairs Work Area Method 6 Alterations: Level 1 may have some The method 7 Alterations: Level 2 dependency between is the choice of the owner. 8 Alterations: Level 3 chapters. The three methods are independent. 9 Change of Occupancy 10 Additions 11 Historic Buildings 12 Moved or Relocated Buildings 13 Performance Compliance Method 6

3 Compliance Methods Three ways to comply with the code: Prescriptive Compliance Method: Additions, alterations or repairs, unless otherwise noted, follow that of new construction. Work Area Compliance Method: Requirements are based on level of work and generally applies to work area only. Performance Compliance Method: Utilizes a point system to ensure the level of public safety, health & welfare is maintained or exceeded after a renovation. Regardless of which option is chosen, IEBC Chapter 1 always applies and contains many unique MA amendments (i.e. structural systems, egress, fire protection, etc).

MA Egress Amendment g IEBC MA Amendment Section 102.2.2 Means of egress in existing buildings, whether or not undergoing repairs, alterations, or changes of occupancy must comply with the code provisions for new construction in regards to: 1) The minimum number of exits 2) Required egress capacity

Sprinklers in Existing Buildings IEBC MA Amendment Section 102.2.1.2 Reference to the amended MGL148 Section 26G All buildings over 7,500 gsf undergoing addition or major renovation Renovations totaling 33% or more of the total gross square footage Renovation costs equal to or greater than 33% of the assessed building value Applies throughout the state

Prescriptive Compliance Method Chapters 3

Prescriptive Compliance Method Alterations (303): Chapter 3 Alterations shall comply with the requirements of the code for new construction. Alterations shall be such that the existing building or structure is no less conforming with the provisions of this code than the existing building or structure was prior to the alteration.

Prescriptive Compliance Method Alterations (303): BBRS FAQ Chapter 3 IEBC Section 303.1 states that alterations to any building or structure shall comply with the requirements of the code for new construction. Under 780 CMR this provision is intended to require that the entire work area (as defined by the IEBC) be brought into full compliance with the provisions of 780 CMR for new construction, unless otherwise specifically exempted by IEBC Chapter 3 (i.e. existing materials (IEBC Section 301.2), IEBC Chapter 3 structural provisions, etc.).

Work Area Method Chapters 4 12

Work Area Compliance Repairs (402): Chapters 4-12 Patching, restoration, or replacement of damaged elements to good or sound condition for maintenance purposes. Level 1 Alteration (403): Alterations to elements to serve the same purpose. reconfiguration of spaces. Level 2 Alteration (404): Reconfiguration of spaces Addition or elimination of windows or doors Installation of any additional equipment Renovation area 50% of the aggregate building area. Level 3 Alteration (405): Renovation area > 50% of the aggregate building area. No

Level 2 Alteration Chapter 7 Enclosure of existing vertical openings (703.2) Interior finishes (703.4) Guards replace if not structurally sound (703.5). Sprinkler, Standpipes & Fire Alarm (704.0). Means of Egress provisions only apply to multi-tenant buildings (705.0). Mechanical (709).

Level 3 Alteration Chapter 8 Compliance with Level 1 and 2 work required (801.2) Enclosure of floor openings expanded beyond work area (803.1). Sprinkler no additional requirements for non-high h rise buildings except in trash & linen chutes (804.1). Fire Alarm & Detection ec required ed per new construction throughout building (804.2). Means of egress provisions from Level 2 & Level 3 apply to all buildings (not limited it to multi-tenant). t t)

Change of Occupancy Chapter 9 Fire Protection Systems, Interior Finish Code for New Construction Hazard Categories Means of Egress (912.4) Height and Area (912.5) Exterior Wall Fire-Resistance (912.6) Enclosure of Vertical Shafts (912.7) Other Meet Level 3 Requirements

Hazard Categories Means of Egress (912.4)

Additions Chapter 10 All additions to existing structures, including areas impacted by an addition, must meet the new construction requirements unless otherwise noted (1001.1) Additions must meet height and area limitations of the code for new construction (1002.1) Existing fire areas increased by the addition must be provided with fire protection systems per the code for new construction (1002.3)

Performance Compliance Methods Chapter 13

Performance Compliance Methods Chapter 13 The design evaluation is comprised of three main categories: Fire Safety Structural Fire Resistance Automatic Fire Detection Fire Alarm Fire-Suppression System Means of Egress Configuration Characteristics Support Features General Safety Fire Safety Parameters Means of Egress Parameters

Evaluation Building Score Section 1301.7 Insert points from evaluation of building elements

Example Compartmentation Section 1301.6.3 Points are awarded based on the size of the compartment enclosed by fire barrier walls and floor/ceiling assemblies.

Evaluation Safety Scores Section 1301.8

Accessibility 521 CMR

521 CMR: Massachusetts Architectural Access Board Existing Buildings: Renovations (3.3) The level of compliance for existing buildings is based on the following thresholds: h Work costs less than $100,000: only the work being performed is required to comply. Work costs $100,000 or more but less than 30% of assessed value of existing building: in addition to work being performed, an accessible public entrance and an accessible toilet room, telephone and drinking fountain must comply with 521 CMR (if public toilets, telephones and drinking fountains are provided). Exempt Work: Curb cuts, MEP without architectural alterations, roof repair or replacement, window repair or replacement, repointing and masonry repair, septic systems, site utilities, and landscaping.

521 CMR: Massachusetts Architectural Access Board Existing Buildings: Renovations (3.3), con t Cost of work is equal to 30% or more of the assessed value of the existing building: entire building is required to comply with 521 CMR. Exempt Work: None In determining applicability of 521 CMR, the cost of all work performed within a 3 year period must be added together.

ADA: 28 CFR Part 36 Existing Buildings: Alterations (36.402, 36.403) Altered portions of a facility are required to comply with the accessibility regulations to the maximum extent feasible. The accessibility of the path of travel and facilities (toilet rooms, drinking fountains, etc.) serving an altered area must also be improved, unless the cost and scope of the overall alteration is disproportionate to the cost of the overall alteration. Disproportionate = cost exceeds 20% of the cost of primary alteration If the cost of alterations to the path of travel or facilities is disproportionate, p these areas must still be improved up to 20% of the cost of the primary alteration. Alterations by a tenant in areas that only the tenant occupies do not trigger an obligation for the landlord to improve the accessibility of the path of travel or facilities used by tenant, if those areas are not otherwise being altered.

Thank You Questions/Comments? -PDF of Presentation http://www.rwsullivan.com/news/ - Contact Info ksh@rwsullivan.com