Bill of Quantities PANDOMO TerrazzoBasic PANDOMO BG/BW TerrazzoBasic two layers on separating sheet or insulation

Similar documents
Bill of Quantities PANDOMO TerrazzoBasic PANDOMO BG/BW TerrazzoBasic single layer on separating sheet or insulation

2. Subfloor Preparation - Removal of Existing Floor Coverings

Tender TENDER DOCUMENTS. Customer. To company. , date. Building project

Ministry for Gozo Administration Centre, St Francis Square, Victoria, Gozo VCT1335, tel ; Fax

TECHNICAL BULLETIN TB102

Data Sheet 3115 Englisch

.2 Section Waste Management and Disposal. 1.2 REFERENCES.1 Codes and Standards referenced in this section refers to the latest edition thereof.

hüma PARKETTSYSTEM GmbH INSTALLATION GUIDE

Specification for Solid Timber Flooring Installation, Sanding and Coating

Technical Data Sheet Version 04/2019 MS PowerFlex 25

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

for the master tradesman Setcrete Product Guide

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

SECTION RESILIENT SHEET FLOORING

Sopro FDP 558 tile insulation board

CERAMIC FLOORING TRADE SPECIFICATION

FERFA GUIDE TO FLOWABLE POLYMER SCREEDS AS UNDERLAYMENTS FOR RESIN FLOOR FINISHES

Roth Compact system. German quality since Installation 1/6

m2 Anti-Slip Tape Daylight Fluorescent R13

APPLICATIONS AND FUNCTION:

EPOXY TERRAZZO 1 REV. 8/02

alternative» The real alternative to natural stone and tiles! «

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

Data Sheet 832 Englisch

RESIN FLOORING. To be read with Preliminaries/ General Conditions TYPE(S) OF FLOORING

CARPET FLOOR COVERING TRADE SPECIFICATION

.2 Section Waste Management and Disposal.

Fax: BY Fax: +44 (0) Tel: N/A Tel: +44 (0) Date: 27 May 2015 Mobile: +44 (0)

PRIMERS & MOISTURE CONTROL SYSTEMS

SECTION RESILIENT TILE FLOORING

TECHNICAL BULLETIN TB147 THE INSTALLATION OF ARDEX DS40 SOUND REDUCTION MATTING IN INTERNAL INSTALLATIONS

Kronotex Click Installation & Care Guide

Appearance /Colours Resin - part A: transparent, liquid Hardener - part B: transparent, liquid Packaging. Pre-proportioned 5.

Guardrail system BARRIER THE RIGHT CHOICE OF A FALL PROTECTION SYSTEM MATTERS. max. 2.2 m

Guardrail system BARRIER THE RIGHT CHOICE OF A FALL PROTECTION SYSTEM MATTERS. max. 2.2 m

SECTION HYDRAULIC CEMENT UNDERLAYMENT

KANPUR SMART CITY LIMITED

THERMAL INSULATION SYSTEM

Surface Protective Systems

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

fermacell Powerpanel H 2 O Linear Shower Outlet 2.0

» The real alternative to natural stone and tiles! «

Construction. 1-part floor joint sealant. Product Description. Product Data. Tests. Form. Storage

Decorative Epoxy Surfacing System

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

Caparol System PRO Data sheet

General Technical Specification

TECHNICAL BULLETIN TB029

INSTALLATION INSTRUCTIONS

CARPET FLOOR COVERING TRADE SPECIFICATION

OMNITEK Deco is suitable for all leveling and thin layer concrete repair applications, such as:

MasterSeal M 616. THEORETICAL CONSUMPTION kg/m 2. PACKAGES 25 kg and 5 kg cans

INSTALLATION METHOD STATEMENT

Speical, substrate-tolerant primer

FLOOR SCREEDS & ADDITIVES SOLUTIONS FOR INDUSTRIAL, RETAIL, RESIDENTIAL & PUBLIC BUILDINGS UZIN. THE FLOOR BELONGS TO YOU.

TECHNICAL BULLETIN TB029

TECHNICAL BULLETIN TB015

BITUMEN-SET PRECAST CONCRETE PAVING SLABS

FLOORING Sikafloor Level UNDERLAYMENT

Installation manual Number TV 02/2016 HE floor coverings Date Pages 5. Tarkett Vinisin Branch of Kalush

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS

BARRIER BARRIER. quick installation. high quality collective side protection. ideal for escape routes. pleasing, unobtrusively design

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

Technical data sheet with laying instructions

3M Building & Commercial Services. Nomad Optima+ Entrance Matting. Engineered. to last. Introducing the new 3M TM Nomad TM Optima+ Entrance Matting

MOISTURE CONTROLLED.

TENDER DOCUMENT PART-II

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

Mapei systems for radiating floor heating with high thermal efficiency

Engine Bay Floors Floor Resurfacing 4000

Flooring Installation Manual DEKTON MANUAL

Relax you bonded the floor with Bona. Bona Adhesives. Unique silane formulations for wood floors.

ARDEX GUIDE SPECIFICATION ARDEX K 60 ARDITEX A Rapid Setting Latex Smoothing and Leveling Compound

TECHNICAL DATA SHEET SIKADUR 31 RAPID 1.2KG

Technical Manual - Section 7 Lytag LWA Roof and Floor Screeds

CONSTRUCTION SPECIFICATION FOR CRACK REPAIR - CONCRETE

a new liquid screed solution

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

VINYL TILE, SHEET & LAMINATED FLOORING TRADE SPECIFICATION

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

The professionals choice. Installation instructions Torridon. shower tray

LIQUID APPLIED WATERPROOF ROOF COATINGS

Detailing guide for senior living facilities

INSTALLATION INSTRUCTIONS LAMINATE

SECTION HYDRAULIC CEMENT UNDERLAYMENT

RESINOUS FLOORING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

Sealing and decoupling. Things to know and technology

SECTION RESILIENT SHEET FLOORING

RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) AT SKALA SYKAMNIAS CHILDRENS PLAYGROUND BILL OF QUANTITIES

AND SUPPORT SMOOTHING & LEVELLING LATEX BASED SPECIFICATION GUIDE // FLOORING RANGE LARTEX FLO LARTEX NA PRODUCT

SECTION RESINOUS FLOORING

SECTION RESILIENT FLOORING

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

1. Division 09 Section "Rough Carpentry."

Levelling compounds.... plane, smooth surfaces with Alfix

Compiled by: Civil Works Department, SSA Punjab.

Transcription:

Bill of Quantities PANDOMO TerrazzoBasic PANDOMO BG/BW TerrazzoBasic two layers on separating sheet or insulation General remarks Products used: The tenderer shall include with the offer technical data sheets and product data sheets for all the products used to produce the floor surface, including screeds, smoothing compounds, primers etc. If the quotation is submitted without technical data sheets, the bid will automatically be excluded from the tendering procedure and will not be considered. System products: All the products used must be procured from a manufacturer who guarantees compliance with the system. This includes impregnating agents, sealants and surface protectants. All materials used and installed must be standardised and approved, or else be shown to have a quality certification that is recognised in Germany, and they must be unused. Emissions from building materials used This project must meet high standards in terms of the environmental and sustainability aspects of the products used. All products used must comply with Emicode Class EC1Plus, having very low emissions, and must not contain any solvents. Approved certificates must be available to ensure the suitability of the products used. In addition, the products must be demonstrated to be sustainable according to the DGND standard. Fundamental principles: The offer, the services described in it and the execution of those services by the company carrying out the work shall comply with the generally accepted rules of best practice that apply in the country of execution, and with the latest version of all rules, regulations, European and national standards, requirements, guidelines, bulletins etc. The instructions for working with modern terrazzo systems, as defined by the generally accepted rules of best practice and the following DIN standards, which entered into force in 2007, shall apply: DIN 18299 in full DIN 18202 in full DIN 18333 only those parts dealing with colour and structure as well as factory-made workpieces. Additional quality criteria are described in the Bill of Quantities. No other Terms of Delivery or Quality Requirements shall apply. Similarly, any references to additional guidelines and descriptions shall not apply. Evaluation: The offer shall be made using the bill of quantities provided. Only complete bills of quantities will be considered when evaluating the offer. Alternative proposals in the form of subsidiary offers will not be permitted. The product must not be installed using a concrete mixer.

References: References shall be provided for comparable services carried out in the past, including pictures and descriptions. Arrangements should be made for on-site inspections. Requirements concerning the appearance and quality of the execution Cracks in the terrazzo will only be tolerated if the width of such cracks is less than 0.4 mm and there is no more than one crack per 100 m². Only cracks that are caused by the underlying structure of the building shall be exempt from this rule. In the case of composite structures, cracks due to shrinkage and craquelure cannot be ruled out. Additional quality criteria are described in the Bill of Quantities. The optical quality must meet the stated requirements. Cleaning and maintenance: The tenderer shall include with the offer cleaning and maintenance instructions as provided by the manufacturer of the flooring. These procedures must be adapted to the particular way in which the project is to be used. Bill of Quantities Unit price Sum Item 01 Building site facilities Lump sum Item 02... m² Lay down impact noise insulation Item 03... m² Lay down separating layer comprising 2 sheets onto suitable substrate. Make... Comply with the manufacturer s recommendations for installation. Item 04... m² Apply screed on a barrier layer according to DIN 18353 / DIN 18560 to a thickness of at least 50 mm, on the floor specified in Item 03, including all necessary edge strips on a suitable substrate, prepared according to the state of the art. Use PANDOMO BG system screed as binding agent, mixed with sand, grain size 0-8 mm, in the ratio 1:4 / 1:5 parts by weight. Requirements to be met by the screed: - Walkable after 8 hours - Ready for installation after 24 hours - System product for terrazzo floors

Comply with the manufacturer s recommendations for installation. Item 05 Test the subfloor for residual moisture using a CM measuring device at least 3 measurements each, up to 50 m². measurements Item 06 Supply and install shrinkage joints for PANDOMO TerrazzoBasic, height X, in accordance with the manufacturer s instructions. a) Stainless steel b) Aluminium c) Brass d) PVC e) Alternative Type Manufacturer m Item 07 Supply and install field limitation rails for ground PANDOMO TerrazzoBasic, height X, in accordance with the manufacturer s instructions. a) Stainless steel b) Aluminium c) Brass d) PVC Type Manufacturer m Item 08 Substrate preparation Remove coarse dirt and building rubble from site and dispose of in containers. Item 09 Mix adhesive primer for PANDOMO TerrazzoBasic with PANDOMO BG binding agent and water to form a slurry, and apply to cement substrate (25 kg PANDOMO BG / PANDOMO BW: 6 l water).

Item 10 Apply PANDOMO TerrazzoBasic to a thickness of at least 25 mm, including all necessary edge strips on a suitable substrate, prepared according to the state of the art. Use PANDOMO BG/BW as a binding agent. Add natural stone aggregate from the region. Increased requirements apply with regard to the evenness of the surface, in accordance with DIN 18202, Tab. 3 Line 4. The finished surface must achieve a floor slip rating of R9 according to DIN EN 51131, and fulfil the fire class A2-S1 according to DIN EN 13501-1 and the emissions class EC1Plus according to Emicode. Requirements to be met by the terrazzo floor - Maximum pore size: 1 mm (diameter) - No traces of grinding are permitted - No cracks in terrazzo floor (see General Remarks) - Product components from the system - Walkable after 8 hours - Grindable after 24 hours - Low shrinkage - Load-bearing after a short time Item 11 Additional thickness of PANDOMO TerrazzoBasic per 5 mm Item 12 Install PANDOMO TerrazzoBasic, but on a ramp with a 4% gradient Item 13 Cost of PANDOMO TerrazzoBasic with 10% PANDOMO TG natural stone aggregate, colour as specified by client Item 14 Cost of PANDOMO TerrazzoBasic with 20% PANDOMO TG natural stone aggregate, colour as specified by client

Item 15 Cost of PANDOMO TerrazzoBasic with suitable colour pigments, colour as specified by client Item 16 Create bays of different colours Item 17 Create friezes with a width of cm Item 18 Creating ornaments and special configurations in accordance with the drawings of the planning engineer Item 19 Install and add door passages, recesses, pillars, pipings and internals Item 20 Grind the PANDOMO TerrazzoBasic from coarse grinding to fine grinding, grain size 400, in 4 to 5 operations without smoothening work. Item 21 Smooth the ground PANDOMO TerrazzoBasic using PANDOMO TFW filler compound before the last grinding operation. Item 22 Grind door passages, recesses, pillars, pipings and internals in addition to Item 18.

Item 23 Carry out basic cleaning of PANDOMO TerrazzoBasic after grinding using a suitable acid-free basic cleaner. Item 24 Impregnate PANDOMO TerrazzoBasic with a suitable impregnation e.g. HTC: StoneProtection, MKS: Thilos, Obtego AG: Obtego R 400 Item 25 Treat PANDOMO TerrazzoBasic using a suitable system product matching Item 23 Item 26 Dispose of slurries and dust produced during grinding according to local regulations. m³ Item 27 Mask off and protect components and internals to a height of at least 80 cm, including subsequent disposal. Item 28 Install PANDOMO TerrazzoBasic locally grooved wooden skirting, height of up to 7 cm/10 cm Item 29 In addition to Item 28, create inside and outside corners. Item 30 Install PANDOMO TerrazzoBasic skirting with height of up to 7 cm/10 cm, thickness 1.5 cm, length up to 40 cm.

Item 31 Install and mount steps, length 1 m, step 4 cm, adjustment step 2 cm, according to the drawings of the planning engineer. Item 32 Install elastic joints with ARDEX ST Natural Stone Silicone in accordance with the normal practice, with a width of up to 10 mm. Item 33 Create sample surface. Colour and structure as specified by client. Overall cost per m² Item 34 Additional charge for extra labour and long transport distances. Overall cost Sum of all items + 19 % VAT Total