Understanding Wind Uplift Ratings

Similar documents
There have been many instances of aircraft hangars roof systems

ASCE 7 10 Wind Code Understanding

Wood Decks Testing Reveals Best Wood Roof Deck Systems to Resist Wind-Uplift by Fulton Desler, senior engineer, APA The Engineered Wood Association

Standard Field Test Procedure for Determining the Uplift Resistance of Insulation and Insulation Adhesive Combinations over Various Substrates

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

Metal Roof Certification & Listing Program

UPLIFT RESISTANCE OF EXISTING ROOF DECKS: RECOMMENDATIONS FOR ENHANCED ATTACHMENT DURING REROOFING WORK

SECTION LIGHTWEIGHT INSULATING CONCRETE

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

ANSI/SPRI IA Standard Field Test Procedure for Determining the Mechanical Uplift Resistance of Insulation Adhesives over Various Substrates

the re-cover option, there are several elements to keep in mind to achieve proper longevity of the new roof system. Replacement vs.

Metal to the metal. by W. Lee Shoemaker, Ph.D., P.E. and Vincent E. Sagan, P.E. and Dale Nelson

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL

THE SITUATION WITH STEEL DECKS

Lightweight Insulating Concrete Roof Decks

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

Compliance Statement: The product as described in this report has demonstrated compliance with

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies

2010 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

SL175 Panel Technical Data Guide

Cost Impact of 2017 FBC EB Roof Diaphragm Reroofing Requirements RINKER CR Interim Report 15 March 2018

ANSI/FM Approvals March FM Approvals LLC. All rights reserved.

SPRI Updates and Improves Roof Edge Standards

ML200 Panel Technical Data Guide

CBUCK Engineering. Florida Product Approval # FL R1

SECTION CEMENTITIOUS WOOD FIBER DECKS

American National Standard Standard Field Test Procedure for Determining the Withdrawal Resistance of Roofing Fasteners

STRUCTURAL DESIGN CRITERIA

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

Scope. resistance expressed as a moment

While there are. April 2003 Interface 23

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

FLORIDA BUILDING CODE

CBUCK Engineering. Florida Product Approval # FL R1

MILLENNIUM METALS, INC TEST REPORT

Engineering Services Program

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

Adhesive Pull Test Standard Testing Procedures

DESIGNING SAFE ROOMS AND SAFE HOMES WITH LOGIX.

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

RECOMMENDED DESIGN SPECIFICATION

INSTALLING A NEW ROOF? Materials, Tips and Considerations

Closed-Cell Spray Foam Insulation. Performance in Residential and Commercial Buildings During Adverse Weather

FM APPROVALS Boston Providence Turnpike, Norwood, MA Phone: (781) Fax: (781) E mail:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

C. Applicable building codes should always be checked prior to proposing the application to Mule-Hide or the building owner.

Prepared for: Thompson Architectural Metals Company, Inc E. Hillsborough Avenue Tampa, FL 33605

2001Co. Compression Board Air Seal Terminations Are a Patented Roof Application Technique

Section Property Standard Year Wind FM Physical Properties ASTM D

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Laboratory Report T R1

DynoRaxx EVOLUTION PR Guide to Code Compliant Installation

C. All roofs shall be installed according to manufacturers guidelines. Corrections due to workmanship shall be at contractors expense.

2001 COMPANY. WIND BLOWN DEBRIS RESISTANT ROOF ASSEMBLIES Hurricane 140 Mph And Tornado 250 Mph Wind Blown Debris

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

2001 COMPANY Co., ASCE 7 98 Wind Uplift Evaluation Form (Ask for Form - ASCE7dpi.doc)

PRODUCT CONTROL SECTION

CBUCK Engineering. Evaluation Report Zee-Lock Panel With Continous Zee-Rib Clip Metal Roof Assembly

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

Builders, Realtors, Roofers and Yourself

ANSI/SPRI FX Standard Field Test Procedure for Determining the Withdrawal Resistance of Roofing Fasteners. Table of Contents. 1.0 Purpose...

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

Fortified For Safer Living

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

A PROGRAM OF IBHS COMMERCIAL

FOAMULAR Commercial Roofing

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

C. Jointing of Exterior Vertical Surfaces. Section D. The Secretary of the US Department of the Interior s Standards for Rehabilitation.

Why FORTIFIED? Tier 1: FORTIFIED Bronze. FORTIFIED Silver. Tier 2: FORTIFIED Gold

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

Specifications. When specifying metal panel roof systems, roof. system designers and specifiers need to be aware

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Certification Report.

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

Firestone Polyiso Boards

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Christopher North Builders, INC.

ACFoam -III Specifications Atlas Roofing

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ACFoam-II HCFC Free "Green" Polyiso Specification

Thermoplastic Single Ply & Multi-Ply Roofing Systems

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

Christopher North Builders INC

CBUCK Engineering. Evaluation Report M-Seam Metal Roof Assembly

Coal Tar Application and Design Considerations

CBUCK Engineering. Evaluation Report Zee-Lock Panel or Curved Zee-Lock Panel Metal Roof Assembly

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Metal Roof Certification & Listing Program

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

CBUCK Engineering. Florida Product Approval # FL R2

CBUCK Engineering. Evaluation Report Englert Series 1100 Metal Roof Assembly. Manufacturer:

Metal Roof Certification & Listing Program. 4. Evaluated Roof System Description: 1. Program Licensee: 2. Certified Roof Covering: 5.

FIRESTONE RUBBERGARD EPDM

Transcription:

Page 1 of 5 Home Understanding Wind Uplift Ratings By Stan Choiniere September 1, 2006 What is an FM Approvals wind test, and what do the various wind uplift ratings mean? This question is frequently asked, but often answered incorrectly. What is an FM Approvals wind test, and what do the various wind uplift ratings mean? This question is frequently asked, but often answered incorrectly. Before we can answer the question, however, we must first define wind uplift. Roof damage caused by wind occurs when the air pressure below the roofing assembly is greater than the air pressure above the building's roof. As wind flows over the building, the pressure directly above the surface of the roof decreases. At the same time, internal air pressure increases due to air infiltration through openings, cracks, etc. The result is a net upward force on the roofing system. This force is referred to as wind uplift. Let's start by clarifying who FM Approvals is and their role in low-slope roofing. FM Approvals is a nationally recognized testing laboratory that tests and certifies building materials, fire protection and electrical equipment that can help prevent or reduce property damage. Those products and services that meet FM Approvals' rigid testing criteria become FM approved and bear the "FM" diamond certification mark. The company is a business unit of commercial and industrial property insurer FM Global, which insures more than one-third of Fortune 1000 companies and similar-size organizations worldwide. Based on decades of experience, FM Approvals has developed many test standards and industry protocols on various property conservation topics. While this article is focused on wind testing, FM Approvals also tests roofing systems for resistance to interior and exterior fire exposure, hail

Page 2 of 5 resistance and long-term weather resistance, as well as other physical properties. This wind uplift test in progress shows a system under pressure. The membrane is beginning to lift in response to increased air pressure from below. (Photo courtesy of OMG Roofing Products.) Common Misconceptions FM Approvals' work has driven the evolution of many types of roofing systems and certainly has played a big role in the development of the high-performance fastening systems we use today. Neither FM Approvals nor FM Global are building code-making bodies, but FM-approved roofing systems are often specified, so it's important that specifiers and designers understand FM Approval's role and the wind ratings. One common misconception is the belief that FM Approvals' windstorm classification ratings such as 1-60, 1-90 or 1-120 correlate to wind speeds of 60, 90 or 120 miles per hour (mph). Building owners and some specifiers and designers don't realize that the ratings apply to uplift pressures in pounds per square foot (psf), not wind speeds. Furthermore, the roofing designer or specifier sometimes assumes if there is a design wind speed requirement of 90 mph, then the roof system must have a 1-90 rating, which is not always true - at least not for the reason they think (maybe for tall buildings, or if other factors exist). The second most common mistake a designer or specifier may make is concluding that wind speed is the only factor used in the equation to determine which FM Approval rating is needed. For FM Approvals (as with the American Society of Civil Engineers, or ASCE), geographic location plays a significant role in system level selection. Consider the example below of how FM Approvals' windstorm classification ratings are used correctly in roofing design. The first step is to verify that the building in question is indeed insured by FM Global. Once that has been confirmed, a variety of data must be gathered about the building and the geography, such as: The building's overall height. The terrain surrounding the structure. The type of roof deck on the building. Whether or not the existing deck meets Factory Mutual minimum standards. Whether or not the building is a "special use" facility such as an airplane hangar, a hospital or a facility with many large dock doors, etc. Whether or not the building has parapet walls, and if it does, their height.

Page 3 of 5 Pictured here are the pressure regulator and manometer at the OMG test facility. It should be noted that this information is needed if using ASCE 7 to determine the uplift resistance needed as well. FM Global has developed property loss prevention engineering guidelines for determining uplift pressure based on ASCE 7. These and other factors are used in conjunction with FM Global Property Loss Prevention Data Sheet 1-28, titled "Design Wind Loads," to establish the uplift forces on the specific building. The wind loads will vary in the corners, perimeter and field of the roof. While data sheet 1-28 will determine the specific "size" of the corner and perimeter zones, data sheet1-29, titled "Roof Deck Securement and Above-Deck Roof Components," will explain how to properly fasten the roof system in these high load areas. Recent revisions to Data Sheet 1-29 significantly change the recommendations of compliance for some types of roof systems. Let's assume that the calculations for our building require a roof that can withstand 23 pounds per square foot of uplift force in the field of the roof. Because FM Approvals requires a 2:1 safety factor, roofs with field of roof uplift forces of 30 pounds per square foot are the maximum for 1-60 ratings, and 37.5 pounds per square foot are the maximum for 1-75 ratings, etc. In this scenario, our building, which is designed with 23 pounds per square foot of uplift, would require an FM Approved Class 1-60 system design, and follow the requirements of data sheet 1-29 for corner and perimeter enhancements. As stated earlier, FM Approvals' requirements are specified carte blanche by many designers on buildings that are not FM Global insured. The assumption is that such systems are safe and can reduce the designer's or specifier's liability. However, in many instances these non-fm Global insured buildings do not meet FM Approvals' minimum requirement for roof decks, etc., yet the designer still calls for an FM-approved system. A perfect example of this occurs frequently on the West Coast, where half-inch plywood is commonly used for roof deck construction. Half-inch plywood does not meet FM Approvals' requirements regardless of the roof cover type. If a building is FM Global insured and has a nonconforming deck type (such as half-inch plywood), FM Global will work with the building owner/designer to find an acceptable roof cover for that project. In general, FM-Approved decks include: Steel - 22 gauge and heavier. Structural concrete - minimum 2,500 psi. Wood - 3/4-inch minimum fire retardant treated plywood, or minimum nominal 2-inch thick fire retardant treated dimensional lumber. Cementitious wood-fiber, such as Tectum. Lightweight insulating concrete. Fiberglass-reinforced plastic.

Page 4 of 5 OMG Roofing Products conducts a wind uplift test on a 12-foot by 24-foot section of a system at its dedicated testing facility in Agawam, Mass. In 1989, Hurricane Hugo ripped through the Carolinas, leaving miles of devastation in its wake. Then, in 1992, Hurricane Andrew pounded South Florida like few storms ever before. The ripple effect of these hurricanes forever changed the face of the commercial roofing industry. As a legacy to these storms, roofing manufacturers continue working to develop roofing systems that will economically meet new, more stringent, FM Approvals and FM Global wind uplift standards, enhanced windstorm classifications, and Dade County, Florida test protocols. A spokesman for FM Global reports that they are unaware of any roof systems that were approved on the 12-foot by 24-foot test frame that failed during Katrina. The failures that did occur to approved roof assemblies were due to damage from windborne debris or inadequately secured corners and perimeters. For a roofing system to qualify for FM Approval, the system must be tested by the laboratory to its product testing standards. The specific test that pertains to wind uplift utilizes a test apparatus designed by FM Approvals. For mechanically attached single-ply roofing systems, the test involves building a roof assembly on a test frame that measures 12 feet by 24 feet. The test frame has the appropriate roof deck attached to supports. Insulation (any type) is then fastened to the deck and the single-ply membrane is secured over the insulation to the deck. The test frame is clamped to a pressure vessel that is pressurized to 30 psf and held at that level for one minute. Assuming that the roofing system remains undamaged at the end of the first minute, the pressure is increased to 45 psf and held for another one-minute period. This process is repeated in 15 psf increments until any component of the system fails. The approval for that assembly is established at the level preceding failure. The minimum wind approval rating is 60 psf. For example, if the pressure level was at 105 psf when the failure occurred, the Approval level would be set at the preceding level or 90 psf, giving the assembly a 1-90 rating. Failure can involve any number of events, such as delamination of the roof seam, membrane tear, screw pullout, etc. While the test is conducted on a product made by a particular deck manufacturer, extension of these approvals to other approved decks (of comparable or greater thickness, depth, rib configuration and yield stress, used within the limits of the approved spans) made by other manufacturers is common based upon favorable comparative testing of the appropriate fasteners for the respective deck types. For other steel decks, pullout tests would not be required. For other deck materials (say, wood) they would be needed to confirm performance. For fully adhered single-ply systems as well as for multi-ply systems, the testing is conducted the same way, with the only difference being the size of the test frame. For fully adhered single-ply systems the test frame is 5 feet by 9 feet if a rating of Class 1-90 or below is desired. If the client desires a higher rating, the test is conducted on the 12-foot by 24-foot test frame.

Page 5 of 5 It is important for building owners and designers alike to understand that FM Approvals ratings do not correlate directly to miles per hour of wind speed, and that understanding FM Approvals testing procedures and windstorm classification ratings will help avoid the many potential problems associated with wind uplift, one of the most common enemies to consider when designing any commercial roofing system. Make Sure Building Owners and Contractors Know What to Expect Below are some of the topics that roofing contractors, building owners and specifiers should discuss. Having these discussions early in the process could save you considerable time when your project comes to fruition: Is the building FM Global insured? If the building is FM Global insured, make sure the system that is recommended meets the proper windstorm classification and contact the local FM Global office prior ordering material or starting any roofing work. Does the recommended system meet all local building code requirements in addition to the FM Approvals requirements and FM Global data sheet recommendations? Understand that roofing manufacturers' warranties do not acknowledge or imply compliance with FM Approvals ratings nor building codes. Make sure you know what type of deck (gauge, depth, rib configuration and yield stress), deck span and deck securement the facility has and that the building meets FM Approvals requirements. If an FM-approved rated system is required, discuss the options with the membrane manufacturer. In many instances, manufacturers have approval ratings that the contractor may not be aware of, which could save you lots of money in terms of labor costs. Stan Choiniere is National Technical Manager, OMG Roofing Products, Agawam, Mass. For more information, visit www.olyfast.com.