Precious Metals in High Temperature Geothermal Systems

Similar documents
Best Practices for Filtration of Dissolved Metals

GEOTHERMAL SINTER TOWARDS A DIAGNOSTICSIGNATURE AND A SINTER GEOTHERMOMETER

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

ATMOSPHERIC CHEMISTRY NITROGEN DIOXIDE Version 1.1 (previously AC Protocol, updated Jan 2001)

A Cycle of Copper Reactions

Application Note AN1501

DEVELOPMENT OF A HIGH TEMPERATURE BOREHOLE FLUID SAMPLER. Nigel HALLADA Y. CSM Associates Ltd. England. ABSTRACT

SEMI C SPECIFICATIONS AND GUIDELINES FOR AMMONIUM HYDROXIDE

Binary Power Plants in New Zealand

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid

Experiment 3: Determination of an Empirical Formula

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

CHM Gravimetric Chloride Experiment (r7) 1/5

What is: (a) aqua fortis, (b) aqua regia (c) Fixation of Nitrogen?

Improved Antimony Recoveries in Soil Matrices by 3050B/6010B. DataChem Laboratories, Inc. Robert P. Di Rienzo Jeffery S. Ward John T.

Collaborative Efforts for Creating a Robust Trace Metals Analytical Procedure for Flue Gas Desulfurization Wastewaters by ICP-MS

ARSENIC IN GEOTHERMAL SINTERS: DETERMINATIONAND IMPLICATIONS FOR MINERAL EXPLORATION

TESTING THE WATERS HOW GOOD IS THAT BOTTLED WATER AND HOW EFFECTIVE IS YOUR WATER FILTER

Partner: Cathy 22 March Separation and Qualitative Determination of Cations and Anions

The following are the completed but unbalanced equations. Each equation is numbered to match each step of the cycle:

Analysis of Metals in Water, Stream Sediments and Floodplain Soils Collected March 21-23, 2005 from the Bayou Creek System. David J.

A Guide to Trace and Ultra-Trace Mercury Testing in Water

The First Two-Phase Tracer Tests at the Matsukawa Vapor-Dominated Geothermal Field, Northeast Japan

Amplifying ICPMS Productivity Using Discrete Sampling Technology

Application Note. Mercury Determination at Ultra-Trace Concentration Using the 906 Elite AAS and MC3000 Mercury Concentrator.

ACETALDEHYDE. The procedure is applicable to corn syrups including those containing fructose, and to most other starch hydrolyzates (Note 1).

NH3 Sampling Protocol Using The Ogawa Sampler*

Procedures for the Collection of Water-Quality Samples From Water-Supply Wells

Evaluation of the Mercury Concentration Accessory for US EPA Methodology

Virtual Curtain Limited

AUSTRALASIA: GEOTHERMAL REPORT 2015

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

Technical Process Bulletin

CARBOWAX SENTRY Polyethylene Glycol (PEG) and Methoxypolyethylene Glycol (MPEG) Products

Alchemy: A Cross-Curricular Activity Copper, Silver, and Gold Redox Reactions

DRAFT EAST AFRICAN STANDARD

Orono Spectral Solutions, Inc.

Technical Process Bulletin

Geothermal Materials Selection Old Lessons, New Directions

METHOD 1311 TOXICITY CHARACTERISTIC LEACHING PROCEDURE

PINAACLE 500/900 AA AND SUPPLIES CONSUMABLES. Consumables and Supplies Reference Guide

Cobalt, atomic absorption spectrophotometry, graphite furnace

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s)

CEH ALPHA Sampler. User Instructions. Issue Number 1. Penicuik, Midlothian EH26 0QB, UK. Bailrigg, Lancaster LA1 4AP

Test Report No. CE/2018/40401 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Safety Precautions. Hydrochloric acid, nitric acid and gold salts are corrosive.

Test Report No. CE/2018/40400 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Test Report No. CE/2018/40399 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Test Report No. CE/2018/40398 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Background Statement for SEMI Draft Document 4546A REVISION OF SEMI C , with title change to SPECIFICATIONS FOR HYDROGEN PEROXIDE

DOWNLOAD PDF CYCLE OF COPPER REACTIONS

Test Report No. CE/2018/40396 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

3. Fill a 50-mL. 2. Press: 1 ENTER The display will show mg/l, Al and the ZERO icon.

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

Test Report No. CE/2018/40402 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Test Report No. CE/2018/40403 Date 2018/04/13 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Fluorine and Chlorine in Cu concentrates and ores by Metrohm Combustion IC

DETERMINATION OF HARDNESS IN A WATER SAMPLE

Copper Odyssey. Chemical Reactions of Copper

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T223.

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

METHOD 3040A DISSOLUTION PROCEDURE FOR OILS, GREASES, OR WAXES

CONSERVATION OF MATTER AND CHEMICAL PROPERTIES

Introduction The Van London Co. Cadmium Ion Electrode is used to measure Cadmium ions in aqueous solutions.

GB Translated English of Chinese Standard: GB

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

Backfilled Pits Laboratory-scale Tests for Assessing Impacts on Groundwater Quality

Interpretation of geochemical data from wells in the western geothermal field of Romania

Ultra-Trace Analysis of Beryllium in Water and Industrial Hygiene Samples by ICP-MS Application

The absorptions vessel was filled with 6ml HCL, Suprapur, VWR art.: and 2ml HNO3, Suprapur, VWR art.:

Background Statement for SEMI Draft Document 4795 (Yellow Ballot) NEW STANDARD: SPECIFICATIONS FOR NITRIC ACID, USED IN PHOTOVOLTAIC APPLICATIONS

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

Core Analysis with the Tracer

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

GENERAL PROCEDURE FOR THE SAMPLING OF SURFACE WATER AND GROUNDWATER

PERCENT Y IELD: COPPER T Ra NSFORMATIONS

PinAAcle 900 AA Flame AA

GNS 2006, 95% C

Technical Process Bulletin

GB (GB/T )

Determination of the Mass Percentage of Copper in a Penny

METALS AND THEIR COMPOUNDS

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

Functionality. Normal Operation

Electron Microscopy (EM) Grid

Polarograph TEA 4000 Ultra Trace Element Analysis

Wheel Test Method Used for Evaluation of Film-Persistent Corrosion Inhibitors for Oilfield Applications

Preparation of Reagent Water

Low Pressure Bottom Hole Sample Collection For Complex Water Characterization

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

Chemical quality of household water in Bangladesh

TITLE: Surface Decontamination of Cadmium Compounds (Cadmium Chloride (CdCl 2 ) and Cadmium Oxide (CdO)) by DeconGel TM

Standard Operating Procedure for the Sampling and Analysis of Total Suspended Solids in Great Lakes Waters

NGAWHA GEOTHERMAL FIELD EXPANSION PROJECT. GEOTHERMAL FLUID CONVEYANCE SYSTEM

Silver bioaccumulation dynamics and modeling in an estuarine invertebrate following aqueous exposure

WATER SAMPLING INSTRUCTIONS READ CAREFULLY AND COMPLETELY BEFORE SAMPLE COLLECTION Call the laboratory if you have questions.

Transcription:

Precious Metals in High Temperature Geothermal Systems K.L. Brown and S.F. Simmons Geothermal Institute, University of Auckland, Private Bag 92-019, Auckland, New Zealand. kl.brown@auckland.ac.nz Abstract High temperature geothermal systems are the modern analogue of epithermal precious metal ore deposits. In these systems, gold and silver are transported primarily as bisulfide complexes, with the precious metals being deposited in response to boiling and mixing of the deep geothermal fluid. In order for the geothermal system to produce an economic precious metal deposit within the typical lifetime of a geothermal system, the deposition process must be efficient, and the gold and silver concentrations in the geothermal fluid must be sufficient. Thermodynamic data has been measured for gold and silver bisulfide complexes, but the question remains as to whether the deep geothermal fluid is saturated with respect to these complexes. Measurement of gold and silver concentrations in geothermal fluid sampled at the surface shows very low concentrations, as these metals precipitate down the well. Indirect measurements of the deep reservoir gold and silver concentrations have been calculated by estimating precipitate concentrations on scale deposits recovered from high pressure apparatus at the surface. These estimates produce precious metal concentrations that are below saturation. We therefore designed and built a downhole sampling device specifically to measure precious and other trace metal concentrations in the deep reservoir fluids. The device is manufactured from titanium to be chemically inert, and therefore capable of scavenging the trace metals through acid rinsing. Analyses for precious and related metals on deep waters obtained from Kawerau and Ngawha geothermal systems have been measured. Solutions were analysed by ICP-MS. Lab testing using blank solutions shows minimal sources of contamination from materials used in the construction and sampling procedure (i.e. titanium, MilliQ water and aqua regia). At Kawerau, samples were obtained from deep wells at 1000 m depth at temperatures of 260 to 295 C, while at Ngawha samples were taken from > 800 m depth at temperatures of 225 to >235 C. Gold, silver and thallium are at ppb levels, while arsenic, antimony and copper range from hundreds to thousands of ppb. Comparing these results with calculated solubilities of gold, silver and acanthite, suggests deep waters are undersaturated in gold but close to saturation in silver. Keywords: Gold, silver, epithermal ore deposits

Introduction Present day high temperature geothermal systems are the modern analogue of precious metal epithermal ore deposits. [1]. Investigations of geothermal systems therefore provide insight into the formation mechanism and evolution of these types of ore deposits. One of the key parameters in modeling the deposition of precious metals in these deposits is the concentration of precious and trace metals in the deep circulating geothermal fluids. These have been difficult to determine because waters ascending wells undergo gas loss which causes metal deposition [2]. Downhole sampling remains the only means by which a deep fluid sample can be obtained and analysed for trace metals. Unfortunately, sampling devices made of steel contribute significant sources of contamination. In an earlier attempt to overcome contamination a ceramic lining was applied to the interior of the steel vessel with promising results [3]. In this paper, we report analytical results for precious and related metals on deep waters collected from geothermal systems with a purpose built titanium sampler. This work is part of a larger investigation assessing the transport and deposition of metals in modern epithermal environments in New Zealand. Experimental The sampler used in this project was purpose built for sampling waters subject to trace metal analysis. It is a modified version of the Klyen sampler. All but the release mechanism, which is constructed of 316 stainless steel, is constructed of titanium with a one litre sampling volume. A titanium non-return valve was incorporated into the design, so the only other materials to make contact with the incoming fluid are the stainless steel shim, which prevents fluid entry to the sampler until pierced by an inertial spring mechanism at the sampling depth, and the VITON o-rings that seal the top and bottom of the sampler and the non-return valve. To assess any trace metal contamination from the titanium, oil free titanium turnings from waste during fabrication were subject to three solution tests: 1. add 200 ml MilliQ water (laboratory water reagent grade III; >18 MΩ) to plastic sample bottle forming the deionised water blank; 2. add 40 ml of aqua regia (30 ml of BDH Aristar HCL and 10 ml of BDH Aristar HNO 3 ) to 120 ml of MilliQ water forming the aqua regia blank; 3. place acid washed titanium turnings into a plastic bottle and add 40 ml of aqua regia, shake for 1 minute and then dilute with 120 ml of MilliQ water forming the titanium blank. All plastic sample bottles were soaked for at least 5 hours in 10% nitric acid then washed six times with MilliQ water. The blank solutions and the sample solutions described below were analysed quantitatively for Au, Ag, Cu, Sb, Tl and As by ICP MS at CSIRO, Centre for Advanced Analytical Chemistry, Lucas Heights, NSW, Australia. The blank results are given in Table 1.

Table 1. Analytical results for Blanks I, II and III reported in µg/l. Ag As Au Cu Sb Tl 1 <.01 <.05 <.01 <.05 <.01 <.01 2.19 <3.0.09.09 0.09 <.01 3.04 <3.0.02.89 0.05 <.01 The small amounts of Ag, Au and Sb contamination in Blanks 2 and 3 are likely sourced from the Aristar HCl used to make the aqua regia. In blank 3, the titanium turnings account for the Cu concentration analysed. Given that earlier estimates of metal contents of deep fluids exceed 1 µg/l [2], these results show minimal contamination from the solutions and materials used in sampling the deep geothermal waters. Kawerau and Ngawha high temperature geothermal fields [4], [5], [6] were chosen for trial testing of the sampler. At both fields, downhole sampling was undertaken on deep vertical wells used for monitoring; i.e. these wells are not used for production. At Kawerau, samples were taken from 1000 m depth at temperatures of 260 to 295 C in wells located in the middle of the production reservoir. At Ngawha, samples were taken from 1300 m and >235 C in NG 13 in the middle of the reservoir and from 800 m and >225 C in NG 4 on the periphery of the reservoir. The sampling methods employed were as follows: Before sampling, all trace metal sampling bottles (1 litre HDPE) were soaked overnight in ~5% HNO 3 (lab grade) and then rinsed with MilliQ water. While sampling, surgical gloves were worn to prevent contamination of the sample as well as to provide skin protection from aqua regia. The titanium sampling equipment was initially cleaned with 40 ml of BDH aqua regia, followed by 40 ml of MilliQ water, followed by a 40 ml of aqua regia, followed by a further 40 ml of MilliQ water. This cleaning routine replicates the post sampling procedure that is used to dissolve any precipitates that may have deposited in the sampler upon cooling and gas loss when the sampler is brought to the surface and opened. These post-sampling rinses were added to the sample in order to preserve the deep metal concentrations as best as possible. For each sample collected, the sampler was fitted with new VITON o-rings and evacuated with a hand pump. The release mechanism was attached, and the sampler was run down the well to the required depth. By a sudden jerk on the wire line, the sampler was triggered, piercing the stainless steel shim, so that well bore fluid could enter the sampler. At the surface, the sampler was opened. The volume of the liquid sample was measured with a volumetric cylinder and transferred to the sample bottle. The sampler was subsequently washed with aqua regia and MilliQ water as described above adding 160 ml of solution to the sample. Black precipitates formed in both samples from Ngawha and so these waters were filtered (0.45µm) before analysis. Measured concentrations were corrected for the dilution of the samples by the aqua regia and DDI water washing, but no corrections were made for the blank analyses.

Results The results of the analyses are reported in Table 2 and are corrected for addition of aqua regia and MilliQ water. For reference the dilution factors reflecting the amount of aqua regia and MilliQ water for rinsing are also reported. Note that at Kawerau, 80 ml of aqua regia plus 80 ml of MilliQ water were added to samples 1, 2 and 4 in the first two rinses of the sampler so that dilution factors reported in Table 2 are somewhat higher than for Ngawha. Having depleted the supply of acid in the field, 50 ml of aqua regia plus 50 ml of MilliQ water total were added to Kawerau sample 5 and the dilution factor reflects this. Unfortunately, no blank samples in which MilliQ water is placed into the sampler then run down to depth, returned to the surface, and acid washed were run due to time and expense. Accordingly, the results need to be considered as preliminary indications of deep trace metal concentrations. We also obtained waters for major element analysis and only the chloride concentrations for these are reported in Table 2. These chloride concentrations are similar to those calculated for the respective reservoirs and demonstrate that representative waters of the deep geothermal system were indeed sampled. Table 2. Results of trace metal analyses on downhole samples of geothermal waters from Kawerau (KA) and Ngawha (NG) wells. All data given in µg/l except for chloride which is given in mg/l. DF=Dilution factor. "M" indicates sample analysed for major cations and anions. sample vol mls Ag As Au Cu Sb Tl DF Cl ppm KA 1 (4) 650 10.20 1220 0.64 1210 380 4.30 1.369 KA 1 (5) 680 1.40 540 0.03 490 125 3.00 1.147 KA 1 M 700 717 KA 2 (1) 600 31.50 4860 2.10 2360 540 4.60 1.400 KA 2 (2) 800 14.30 3120 0.70 770 480 7.50 1.300 KA 2 M 750 1204 NG 4A 780 0.40 170 1.00 750 470 1.8 1.205 NG 4B 780 7.00 430 0.50 4700 1690 3.8 1.205 NG 4 M 780 1249 NG 13A 730 10.10 380 0.70 1050 470 1.4 1.219 NG 13B 650 19.10 770 0.50 1770 2080 4.7 1.246 NG 13M 730 1242 Discussion The results in Table 2 show gross trends that are consistent with earlier determinations of deep trace metal contents at Broadlands Ohaaki [2], [3]. Accordingly, gold and silver concentrations of deep geothermal waters are at ppb concentrations with most Ag/Au ratios ranging from 10 to 20. Thallium also occurs at ppb level. By contrast, copper, arsenic and antimony range from hundreds to thousands of ppb. Arsenic is five to ten times more concentrated than antimony at Kawerau, while antimony is about two to four

times more concentrated than arsenic at Ngawha. Given the stibnite deposition in the heat exchangers at Ngawha [7], this difference is not so surprising. At a finer scale of examination, the results in Table 2 show considerable variation that likely reflects the vagaries of sampling and analysis for trace metals. For example, all replicate samples show greater than a two times difference in gold concentration except for the two samples from Ng 13. In these same two samples, however, silver concentrations are different by almost two times. Dark precipitates only formed in the Ng 13 samples so while they might account for metal variations here, they cannot account for the metal variations in the other samples. In the absence of a downhole sample blanks, we reserve detailed discussion of trace metal variations to subsequent reports. Gold and Silver Solubilities: Taking the known reservoir fluid compositions and temperatures (based on water and gas samples from production wells) it is possible to assess the maximum concentrations of gold and silver in solution assuming that the following equilibria are attained: Au + H 2 S + HS - = Au(HS) 2 - +0.5 H 2 Ag + H 2 S + HS - = Ag(HS) 2 - +0.5 H 2 Ag 2 S + H 2 S + 2 HS - = 2 Ag(HS) 2 - Data for gold solubility are from Shenberger and Barnes [8], and the data for silver solubility are from Gammons and Barnes [9]. Solubilities reported in Table 3 are calculated with program software SOLVEQ and CHILLER [10], [11]. Table 3. Calculated aqueous concentrations (ppb) of gold and silver in deep reservoir waters assuming equilibria with gold, silver or acanthite (Ag 2 S). Kawerau Ngawha Au 36.3 6.0 Ag 30.7 7.9 Ag 2 S 23.7 5.9 Comparing the calculated solubilities with the results in Table 2 suggests that the deep waters at both Kawerau and Ngawha are undersaturated in gold, consistent with earlier findings [2]. By contrast, the silver contents of deep waters are much closer to saturation. Future Work: We have also obtained downhole samples from Mokai and Rotokawa at temperatures greater than 300 C beyond the working limits of the VITON seals. The results from these efforts were mixed and difficult to assess, though we learned that sample blanks need to be incorporated into the survey procedure. These two fields will be revisited in future sampling.

Acknowledgements We thank the Ministry of Commerce and Top Energy for access to geothermal wells for sampling. We also thank Century Resources for their assistance in obtaining downhole samples. Peter Dorrington (Top Energy) and Tricia Scott (NZ Environmental Ltd) deserve special mention for their assistance and cooperation with the sampling at Ngawha. This work was funded by a PGSF-FRST contract. References [1] White, D.E. 1981, Active geothermal systems and hydrothermal ore deposits. Econ Geol, 75th anniversary volume, pp392-423 [2] Brown, K. L., 1986, Gold deposition from geothermal discharges in New Zealand: Economic Geology, v. 81: 979-983. [3] Brown, K. L., Webster, J. G. and Christenson, B. W., 1996, Precious metal sampling at the Ohaaki geothermal field: Proceedings of the 19th New Zealand Geothermal Workshop, Auckland, p. 169-174. [4] Christenson, B. W., 1987, Fluid-mineral equilibria in the Kawerau hydrothermal system, Taupo Volcanic Zone, New Zealand: unpub. Ph. D. thesis, University of Auckland, 452 pp. [5] Skinner, D.N.B., 1981. Geological setting and sub-surface geology of Ngawha, chapter 2, The Ngawha geothermal area, geothermal report no. 7. DSIR, New Zealand, pp. 14-35. [6] Sheppard, D. S. and Giggenbach, W. F., 1985, Ngawha well fluid compositions. DSIR Geothermal Report 8, p. p. 103-119. [7] Dorrington, P. and Brown, K. L., 2000, Management of stibnite deposition at Ngawha. Proceedings of the 22nd New Zealand Geothermal Workshop, Auckland, p. 163-168. [8] Schenberger, D. M. and Barnes, H. L., 1989, The solubility of gold in aqueous sulfide solutions from 150 to 300 C. Geochimica Cosmochimica Acta, v. 53, p. 269-278. [9] Gammons, C. H. and Barnes, H. L., 1989, The solubility of Ag2S in near-neutral aqueous sulfide solutions at 25 to 300 C. Geochimica Cosmochimica Acta, v. 53, p. 279-290. [10] Reed, M. H., 1982, Calculation of multicomponent chemical equilibria and reaction processes in systems involving minerals, gases, and an aqueous phase: Geochimica Cosmochimica Acta, v. 46, p. 513-528.

[11] Spycher, N. F. and Reed, M. H., 1989, Evolution of a Broadlands-type epithermal ore fluid along alternative P-T paths: Implications for the transport and deposition of base, precious and volatile metals: Economic Geology, v.84, p. 328-359.