D. B. G R A Y E N G I N E E R I N G I N C.

Similar documents
D. B. G R A Y E N G I N E E R I N G I N C.

D. B. G R A Y E N G I N E E R I N G I N C.

Silver Seven Corporate Centre Phase 1

D. B. G R A Y E N G I N E E R I N G I N C.

ADEQUACY OF SERVICING REPORT St. Joseph Boulevard Orleans (Ottawa), Ontario. Report No June 8, 2016

DESIGN BRIEF MIX-USE DEVELOPMENT ICON 505 PRESTON STREET OTTAWA, ONTARIO

D. B. G R A Y E N G I N E E R I N G I N C. Stormwater Management - Grading & Drainage - Storm & Sanitary Sewers - Watermains

SITE SERVICING REPORT CHOICE PROPERTIES 1251 STITTSVILLE MAIN STREET

FUNCTIONAL SERVICING AND STORMWATER MANAGEMENT STUDY 405 TWEEDSMUIR AVENUE

Site Servicing & Stormwater Management Report for Site Plan Control Application. Proposed New Multi-Unit Development 284 Presland Road Ottawa, Ontario

SCHAEFFERS FUNCTIONAL SERVICING REPORT PROPOSED RESIDENTIAL DEVELOPMENT LAKESHORE ROAD WEST TOWN OF OAKVILLE

New Retirement Home 6758 & 6766 Rocque Street Orleans, Ontario

215 Sanders Street, Unit 1 (613) Prescott Street, Unit 1 P.O. Box 189 Kemptville, Ontario K0G 1J0 FAX: (613)

Functional Servicing Report. Winston Park West Proposed Business Park Development Project. Infrastructure Ontario (IO) September MU1

DERRY GREEN BUSINESS PARK WATER AND WASTEWATER SERVICING AREA SERVICING PLAN

Julia Bahen, Urban Strategies Inc.

P: (905) F: (905) PROPOSED BANK. Prepared For: ENT INC. JUNE Rev 0.docx

Dunpar Developments Inc.

SITE SERVICING PRELIMINARY DESIGN BRIEF

CITY OF SASKATOON DESIGN AND DEVELOPMENT STANDARDS MANUAL SECTION FOUR WATER DISTRIBUTION SYSTEM

Avalon Encore Stage 6 Block 236 Infrastructure Servicing Brief

255 NORTHFIELD DRIVE EAST

PROPOSED SHOPPERS DRUG MART RIVER ROAD AND EARL ARMSTRONG ROAD OTTAWA, ONTARIO ENGINEERING REPORT SHOPPERS DRUG MART. January 2016

PRELIMINARY MUNICIPAL SERVICING REPORT NORTHWOODS SUBDIVISION. Prepared for: North Grassie Properties Inc.

St. Boniface Industrial Park Phase 2 Municipal Servicing Report

OHM Groups. FUNCTIONAL SERVICING REPORT 33 Arkell Road City of Guelph August 5, Prepared By:

PROPOSED THREE-STOREY RESIDENTIAL APARTMENT BUILDING SITE LOT 19 R-PLAN ROCKINGHAM AVENUE CITY OF OTTAWA STORM DRAINAGE REPORT

DEVELOPMENT ENGINEERING REVIEW MANUAL (Regional Services)

WESTMINISTER WOODS EAST PHASE 10 (CLAIR/VICTORIA), GUELPH FUNCTIONAL SERVICING REPORT

Drainage Servicing Report - Terms of Reference

PROPOSED THREE STOREY RESIDENTIAL APARTMENT BUILDING SITE LOTS 187 AND 188 R PLAN DONALD STREET CITY OF OTTAWA SERVICEABILITY REPORT

D. B. G R A Y E N G I N E E R I N G I N C.

PROPOSED THREE STOREY RESIDENTIAL APARTMENT BUILDING SITE LOTS 187 AND 188 R PLAN DONALD STREET CITY OF OTTAWA SERVICEABILITY REPORT

STORM WATER REPORT. Proposed Row House Complex Clare and Hilson 566 Hilson Ave. & 148 Clare St. Ottawa, Ontario PREPARED FOR:

Longfields Subdivision, Block 7, City of Ottawa

New Retirement Home 6758 & 6766 Rocque Street Orleans, Ontario

Marianneville Developments Ltd.

Riverside South Block 3/4, Richcraft Group of Companies Inc., City of Ottawa SERVICING REPORT

Stormwater Erosion Control & Post-Construction Plans (Stormwater Quality Plans)

TOWN OF MANCHESTER PLANNING AND ZONING COMMISSION Subdivision Application Minimum Submission Requirements

Design Specifications & Requirements Manual

Planning Considerations for Stormwater Management in Alberta. R. D. (Rick) Carnduff, M. Eng., P. Eng. February 20, 2013.

Sanitary Sewer Design. Sanitary Sewers, Page 1

APPENDIX F: DRAINAGE AND STORMWATER MANAGEMENT

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

TOWN OF BETHLEHEM SWPPP APPLICATION REVIEW CHECKLIST

Section H - Site Plan Guidelines

STORMWATER DRAINAGE ASSESSMENT. 479 Line 1 Road, Niagara-on-the-Lake, Ontario

Table of Contents. 1.0 Introduction Existing Site Conditions Proposed Site Statistics Sanitary Servicing Review...

S.O.P. No. HMD

SERVICING AND STORM WATER MANAGEMENT REPORT

Design Specifications & Requirements Manual

MINTO COMMUNITIES INC.

Orleans Family Health Hub

ASSESSMENT OF ADEQUACY OF PUBLIC SERVICES BRIGIL 460 ST. LAURENT BOULEVARD

UBC Technical Guidelines Section Edition Sanitary Sewerage Utilities Page 1 of 6

STORMWATER MANAGEMENT REPORT. Dundas Square Gardens Inc. High Rise Residential/Commercial Development

PROPOSED THREE STOREY RESIDENTIAL APARTMENT BUILDING SITE LOT 47 R PLAN CROYDEN AVENUE CITY OF OTTAWA STORM DRAINAGE REPORT REPORT R

Water supply components

215 Sanders Street, Unit 1 (613) Prescott Street, Unit 1 P.O. Box 189 Kemptville, Ontario K0G 1J0 FAX: (613)

PROPOSED FIVE STOREY MIXED USE BUILDING DEVELOPMENT SITE LOT 2 R PLAN M BANK STREET CITY OF OTTAWA STORM DRAINAGE REPORT

West Clayton NCP Stage 1

STANLEY FARM SUBDIVISION

Blackstone Community Phase 4-8 Functional Servicing Report

Site Servicing and Stormwater Management Report for Site Plan Control Application C&C Transportation 8015 Russell Road Ottawa, Ontario

Water Resources Management Plan

Public Information Centre No. 1

ENGINEERING REVIEW CHECKLIST City of Mount Clemens

SITE SERVICING & STORMWATER MANAGEMENT STUDY

PROPOSED FIVE STOREY MIXED USE BUILDING DEVELOPMENT SITE LOT 2 R PLAN M BANK STREET CITY OF OTTAWA SERVICEABILITY REPORT

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

LOW IMPACT DEVELOPMENT INTERIM GUIDANCE DOCUMENT

Stormwater Management & Servicing Report KMA Mosque and Community Centre 351 Sandhill Road, Ottawa, Ontario

10 LOUISA STREET - THORNBURY

Appendix B Stormwater Site Plan Submittal Requirements Checklist

CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413

HOTEL KANATA 140 HEARST WAY KANATA, ONTARIO STORMWATER MANAGEMENT REPORT. Prepared for: David Johnston Architect. Prepared By:

To: Kevin Murphy From: Gregory Chochlinski David Schaeffer Engineering Ltd. 120 Iber Road, Unit 103 Stittsville, ON K2S 1E9

A Stormwater Management Plan and Sediment Control Plan are required for all proposed developments within the City of Richmond.

Section 3 General Development Policies

Section D Sanitary Drainage

3.9 times the average 3.8 times the average 3.6 times the average

Design Specifications & Requirements Manual

EXECUTIVE SUMMARY DAVID SCHAEFFER ENGINEERING LTD. DSEL

Stormwater Management Report Bachman Terrace Residential Development

2. DEFINITIONS. American Association of State Highway and Transportation Officials.

The Islamic University of Gaza- Civil Engineering Department Sanitary Engineering- ECIV 4325 L5. Storm water Management

Yorkton Rona Commercial and Industrial development. Concept Plan and Serviceability Report

6 STOREY CONDOMINIUM 7480 DERRY ROAD WEST, MILTON

Orleans Family Health Hub

Functional Servicing Report

Flood-Resilient Community Design: Disaster Mitigation, Best Practices for Building New Residential Subdivisions

Storm Sewers, Page 2

Functional Servicing and Stormwater Management Report Appleby Mall Residential Burlington ON

JOHNSTON ROAD LAND USE STUDY

Functional Servicing Report. Sorensen Court Townhouses. 25 Sorensen Court, Niagara-on-the-Lake, Ontario

Half Moon Bay South Draft Plan #3

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Site Servicing and Stormwater Management Report Sélection Retraite - Orléans

LOT GRADING GUIDELINES FOR LOW DENSITY RESIDENTIAL PROPERTIES

Transcription:

SERVICING BRIEF Mutchmor Public School Addition 185 Fifth Avenue Ottawa, Ontario Report No. 12073-SB February 15, 2013 D. B. G R A Y E N G I N E E R I N G I N C. Stormwater Management - Grading & Drainage - Storm & Sanitary Sewers - Watermains 1052 Karsh Drive, Tel: (613) 249-8044 Ottawa, Ontario. Fax: (613) 249-9815 K1G 4N1 email: dbgray@rogers.com 1

SERVICING BRIEF Mutchmor Public School Addition 185 Fifth Avenue Ottawa, Ontario The following Servicing Brief is a description of the existing services of a public school located on 0.52 ha of land at 185 Fifth Avenue (also having frontage on Fourth Avenue and Lyon Street). A two storey addition is proposed. Refer to drawing SG-1 & SG-2 (Revision 2: Feb 15-13), and Stormwater Management Report No. 12073- SWM (February 15, 2013) prepared by D. B. Gray Engineering Inc. Water Supply for Fire Fighting: There are four existing fire hydrants in the municipal right-of-way near the school. Two are on the north side of Fourth Avenue. One is near the Lyon Street intersection approximately 26m from the Fourth Street main entrance. The other is approximately 82m to the west of the Fourth Street main entrance. Another two are on the south side of Fifth Avenue. One is near the Ralph Street intersection approximately 26m from the Fourth Street main entrance. The other is approximately 63m to the east of the Fourth Street main entrance. The original building built in 1894 and the 1911 and 1920 additions and have a standpipe system with 38mm hose connections but are not sprinklered. The 1980 gymnasium addition is sprinklered in the basement portion of the gymnasium addition only and has a standpipe system. The new addition will be sprinklered with no standpipe. A preliminary calculation by the mechanical engineer (Goodkey, Weedmark & Associates Limited), as calculated as per NFPA13, indicates that the maximum required flowrate (including the inside outside hose allowance) is 500 USgpm (31.5 l/s). The boundary conditions, based on the City of Ottawa computer simulation of the water distribution system in this area, are required to determine if an adequate water supply for firefighting is available. Water Service: There are two existing water service connections serving the school. An existing 100mm water service connecting to a 400mm municipal watermain in Fourth Avenue feeds the fire protection system. An existing 38mm water service connecting to a 400mm municipal watermain in Fifth Avenue feeds the domestic water system. However the existing 38mm service is not sized to accommodate the new addition. The existing domestic water plumbing system will be modified so that all water requirements (fire protection and domestic use) for the existing building and new addition will be served by the 100mm service connection. The 38mm water service will be abandoned. Based on the AWWA water flow demand curve and an estimated water pressure at the meter of 414 kpa (60 psi), the peak demand is expected to be 10.2 l/s (162 USgpm). The AWWA method calculates the instantaneous demand and is used to size the water service. This peak demand will produce an acceptable velocity of 1.3 m/s in the existing 100mm water service connection. Based on the City of Ottawa Design Guidelines the daily average consumption rate for a school is 70 litres per student per day. However the subject school is elementary school without a cafeteria and without showers, as such 30 litres per student per day is appropriate. At a capacity enrollment of 580 students the daily average demand is calculate to be 0.5 l/s. Based on this figure and the MOE Design Guidelines, a maximum daily demand of 4.4 l/s and maximum hourly demand 6.7 l/s can be expected. To determine water pressure under these demands the boundary conditions (based on the City of Ottawa computer simulation of the water distribution system in this area) are required. In summary, we request the boundary conditions for the Somerset Street West / Booth Street based on the following: Average daily demand: 0.5 l/s. Maximum daily demand: 4.4 l/s. Maximum hourly daily demand: 6.7 l/s Fire Flow demand: 31.5 l/s Max. Day + Fire Flow demand: 35.9 l/s 2

Sanitary Service: Based on the City of Ottawa Sewer Design Guidelines for a school without a cafeteria and without showers (30 litre / student / day; 1.5 peaking factor; and a 0.28 litre / sec / ha infiltration flow) and with an existing enrollment of 300 students, the peak flow is calculated to be 0.30 l/s. With an existing capacity of 390 students the peak flow is 0.35 l/s. With the proposed addition and a capacity student enrollment of 580 students the flow is calculated to be 0.45 l/s. The existing sanitary sewer service is 200mm in diameter, is assumed to have at least a 1% slope and connects to a 450mm municipal combined sewer in Fourth Avenue. The maximum peak post development flow of 0.45 l/s will be adequately handled by the existing sanitary sewer service (34.2 l/s capacity at 1%). The proposed sanitary service will connect to an existing 450mm municipal combined sewer. The increase between the existing condition (300 student enrollment) and the proposed 580 student capacity is 0.15 l/s. This increase in sanitary flows contributing to the existing combined sewer is expected to have a negligible impact given its capacity of 165.6 l/s. Stormwater: Infrastructure Approvals staff advised that the stormwater quantity control measures are to be based on the criteria that the release rate, for post-development storm events, from the roof of the proposed addition is equal to or less than the flow produced by a five year storm using a runoff coefficient of 0.40 and a 20 minute time of concentration. (See Stormwater Management Report No. 12073-SWM, dated February 15, 2013, prepared by D. B. Gray Engineering Inc.) The existing storm sewer service is 150mm in diameter, is assumed to have at least a 1% slope and connects to a 450mm municipal combined sewer in Fourth Avenue. Currently only the gymnasium roof drains to this existing connection. During the 5-year event the peak flow from the gymnasium roof is 9.4 l/s. The proposed addition will also drain to this connection. Each of two roof drains on the addition roof will be flow control type. During the 5-year event the peak restricted flow from the addition roof is 2.6 l/s. Therefore the peak flow drain to the existing 150mm storm sewer connection is 12.0 l/s (9.4 + 2.6 l/s). This post development flow will be adequately handled by the existing storm sewer service (15.9 l/s capacity at 1%). The 2.6 l/s increase in stormwater flows contributing to the existing combined sewer is expected to have a negligible impact given its capacity of 165.6 l/s. There is also an existing storm sewer system that drains a 1430 sq.m. area consisting mainly an asphalted playground and part of an asphalted parking area. This system connects to a 600mm municipal combined sewer in Fifth Avenue. During the 5-year event the peak flow from this area is currently 36.8 l/s. This existing storm sewer system will be abandoned. A proposed storm sewer system connect to the Fifth Avenue combined sewer will drain 440 sq.m. During the 5-year event the peak flow from the proposed storm sewer system is 6.9 l/s. The 81% decrease in flow is expected to have a positive impact on the combined sewer system. Since the stormwater management facility and storm sewer system discharges to combined sewers it is expected that Ministry of Environment Environmental Compliance Approval (ECA) will be required. Conclusions: 1. Boundary conditions are required to determine if there is an adequate water supply for fire fighting. 2. We require the boundary conditions to determine if the existing water pressure is adequate for the proposed development. 3. Boundary conditions are required to determine if the water pressure can be above 80 psi and if a pressure reducing valve is required. 4. The proposed water service connection is adequately sized to serve the development. 5. The expected sanitary sewage flow will be adequately handled by the proposed sanitary sewer service connection. 6. The increase in sanitary flows contributing to the existing municipal combined sewer is expected to have a negligible impact. 7. The stormwater quantity control is based on the criteria that the release rate for post-development storm events is equal to or less than the flow produced by the existing conditions. 8. The restricted flowrate produced by a one in five year storm event will be adequately handled by a proposed storm sewer. 9. The stormwater flows contributing to the existing municipal combined sewers are expected to have a negligible or positive impact. 10. It is expected that a Ministry of Environment Certificate of Approval will be required because of the storm connection to a combined sewer. 3

Mutchmor Public School Ottawa, Ontario Water Demand WATER FIXTURE VALUE (AWWA Manual M22 - Sizing Water Service Lines and Meters) 15-Oct-13 No. F.V. Total Bathtub 0 8 0 Tiolet - tank 0 4 0 Tiolet - flush valve 43 35 1505 Lavs. 67 1.5 100.5 Urinal - pedestal flush valve 20 35 700 Urinal - wall flush valve 0 16 0 Shower 1 2.5 2.5 K. Sink 0 2.2 0 Dishwasher 0 2 0 Clothes Washer 1 6 6 Commercial Sink 0 4 0 J. Sink 4 4 16 Commercial Dishwasher 0 4 0 Commercial Washer 0 4 0 Hose 1/2 in 0 5 0 2330 Peak Demand (fig 4-2 or 4-3 AWWA M22) 150 USgpm Pressure @ Meter 414 kpa 60 psi (assumed) Pressure Factor (table 4-1 AWWA M22) 1.00 Peak Demand 150 Usgpm Irrigation - hose 1/2 in 2 12 USgpm (includes pressure factor) (assume no hose bibs operating) TOTAL PEAK DEMAND 613 l/min 162 Usgpm 10.22 l / sec Nominal Size 3.9 in 100 mm 4.3 ft/s 1.3 m/s DAILY AVERAGE 30 litres / student / day (no cafeteria / no showers) 580 students 30.4 l / min 0.51 l / sec 8.0 Usgpm 17,400 l /day 50 equivalent persons (350 l / day) MAXIMUM DAILY DEMAND 8.7 (Peaking Factor for a equivalent population of 80: Table 3-3 MOE Design Guidelines for Drinking-Water Systems) 265.9 l / min 4.43 l / sec 70.2 Usgpm MAXIMUM HOURLY DEMAND 13.2 (Peaking Factor for a equivalent population of 80: Table 3-3 MOE Design Guidelines for Drinking-Water Systems) 400.3 l / min 6.67 l / sec 105.8 Usgpm 4

D. B. G R A Y E N G I N E E R I N G I N C. SANITARY SEWER DESIGN FORM Average Daily Flows: Peaking Factor: PROJECT: Mutchmor PS, Ottawa Residential: 350 l / capita / day Residential (Harmon Equation): P.F. = 1 + 14 COMMENTS Stormwater Management - Grading & Drainage - Storm & Sanitary Sewers - Watermains 300 students x 30 l/student/day (no cafeteria / no showers) 1052 Karsh Drive Tel: (613) 249-8044 Commercial: 50,000 l / ha / day P = Population / 1000 4 + P 0.5 Designed By: DBG Ottawa, Ontario. Fax: (613) 249-9815 Instituational: 50,000 l / ha / day K1G 4N1 email: dbgray@rogers.com Light Industrial: 35,000 l / ha / day Infiltration Allowance: 0.28 l / s / ha 16-Feb-13 Heavy Industrial: 55,000 l / ha / day Page: 1 of 1 Section Cumulative Section Cumulative SEWER DATA LOCATION Single Semi / Duplex / Apartments Apartments Apartments Apartments Residential Non-Residential Infiltration n = 0.013 Family Townhouse Triplex (average) (1 Bed.) (2 Bed.) (3 Bed.) Residential Sewage Total Area Area Peaking Area Flow Peaking Flow Flow STREET FROM TO ppu = 3.4 ppu = 2.7 ppu = 2.3 ppu = 1.8 ppu = 1.4 ppu = 2.1 ppu = 3.1 Pop. Flow Type of Dia. Actual Dia. Nom. Slope Length Capacity Velocity Ratio Factor Factor No. of Units No. of Units No. of Units No. of Units No. of Units No. of Units No. of Units ha ha l/ha/day ha l/s l/s l/s Pipe (mm) (mm) (%) (m) (l/s) (m/s) Q/Qfull EXISTING ENROLLMENT 390 students x 30 l/student/day (no cafeteria / no showers) 580 students x 30 l/student/day (no cafeteria / no showers) BUILDING STREET 0.000 0 4.0 0.5118 17585 1.5000 0.512 0.16 0.14 0.30 203.2 200 1.000 92.4 34.2 1.06 0.01 estimated EXISTING SCHOOL CAPACITY BUILDING STREET 0.000 0 4.0 0.5118 22860 1.5000 0.512 0.20 0.14 0.35 203.2 200 1.000 92.4 34.2 1.06 0.01 estimated EXISTING SCHOOL WITH PROPOSED ADDITION CAPACITY BUILDING STREET 0.000 0 4.0 0.5118 33998 1.5000 0.512 0.30 0.14 0.45 203.2 200 1.000 92.4 34.2 1.06 0.01 estimated 5 EXISTING 450mm COMBINED SEWER IN FOURTH AVENUE 457.2 450 0.310 165.6 1.01

D. B. G R A Y E N G I N E E R I N G I N C. Stormwater Management - Grading & Drainage - Storm & Sanitary Sewers - Watermains STORM SEWER COMPUTATION FORM PROJECT: Mutchmor PS Addition, Ottawa 1052 Karsh Drive Tel: (613) 249-8044 RATIONAL METHOD Q = 2.78 A I R FIVE YEAR EVENT Designed By: DBG Ottawa, Ontario. Fax: (613) 249-9815 K1G 4N1 email: dbgray@rogers.com n = 0.013 Date: 15-Feb-13 COMMENTS Page: 1 of 1 Time of Rainfall SEWER DATA LOCATION AREA (ha) Individual Accum. Peak Flow Conc. Intensity Type of Dia. Actual Dia. Nom. Slope Length Capacity Velocity Time of Ratio 2.78 A R 2.78 A R Q (l/s) STREET FROM TO R = 0.9 R = 0.70 R = 0.2 R = 0.9 (min) I (mm/hr) Pipe (mm) (mm) (%) (m) (l/s) (m/s) Flow (min) Q/Qfull EXISITNG CONDITIONS - ASPHALT PARKING AREA AND PLAYGROUND 5TH AVE 0.140 0.003 0.353 0.353 10.0 104 36.8 EXISITNG CBs PROPOSED STORM SEWER SYSTEM CB-1 CB/MH-2 0.010 0.025 0.025 10.0 104 2.6 PVC SDR 35 254.0 250 0.430 14.0 40.7 0.80 0.3 0.06 CB/MH-2 CB/MH-3 0.003 0.007 0.002 0.014 0.039 10.3 103 4.0 PVC SDR 35 254.0 250 0.430 16.4 40.7 0.80 0.3 0.10 CB/MH-3 MH-4 0.005 0.014 0.003 0.029 0.068 10.6 101 6.9 PVC SDR 35 254.0 250 0.430 2.2 40.7 0.80 0.0 0.17 MH-4 5TH AVE 0.000 0.068 10.7 101 6.9 PVC SDR 35 254.0 250 0.430 9.9 40.7 0.80 0.2 0.17 EXISITNG 600mm COMBINED SEWER IN FIFTHE AVENUE 6 609.6 600 0.300 350.8 1.20 EXISITNG CONDITIONS - GYMNASIUM ROOF 4TH AVE 0.036 0.090 0.090 10.0 104 9.4 152.4 150 1.000 15.9 0.87 0.59 EXISITNG ROOF PROPOSED CONDITIONS - GYMNASIUM ROOF + RESTRICTED FLOW FROM PROPOSED ADDITION ROOF 4TH AVE 0.117 0.293 0.293 10.0 104 30.6 152.4 150 1.000 15.9 0.87 1.92 UNRESTICTED FLOW EXISITNG + ADDITION ROOF RESTICTED FLOW FROM ADDITION ROOF (2.7 l/s) 12.0 152.4 150 1.000 15.9 0.87 0.75 EXISITNG 450mm COMBINED SEWER IN FOURTH AVENUE 457.2 450 0.310 165.6 1.01

City of Ottawa Servicing Study Checklist General Content Executive Summary (for large reports only): not applicable Date and revision number of the report: see page 1 of Servicing Brief Location map and plan showing municipal address, boundary, and layout of proposed development: see drawings SG-1 and SG-2 Plan showing the site and location of all existing services: see drawings SG-1 and SG-2 Development statistics, land use, density, adherence to zoning and official plan, and reference to applicable subwatershed and watershed plans that provide context to which individual developments must adhere: not applicable Summary of Pre-consultation Meetings with City and other approval agencies: not applicable Reference and confirm conformance to higher level studies and reports ( Master Servicing Studies, Environmental Assessments, Community Design Plans), or in the case where it is not in conformance, the proponent must provide justification and develop a defendable design criteria: not applicable Statement of objectives and servicing criteria: see page 1 of Servicing Brief Identification of existing and proposed infrastructure available in the immediate area: see drawings SG-1 and SG-2 Identification of Environmentally Significant Areas, watercourses and Municipal Drains potentially impacted by the proposed development ( Reference can be made to the Natural Heritage Studies, if available). not applicable Concept level master grading plan to confirm existing and proposed grades in the development and drainage, soil removal and fill constraints, and potential impacts to neighbouring properties. This is also required to confirm that the proposed grading will not impede existing major system flow paths: not applicable Identification of potential impacts of proposed piped services on private services (such as wells and septic fields on adjacent lands) and mitigation required to address potential impacts: not applicable Proposed phasing of the development, if applicable: not applicable Reference to geotechnical studies and recommendations concerning servicing: see note 1.5 on drawing SG-2 All preliminary and formal site plan submissions should have the following information: Metric scale: included North arrow: included (including construction North): not included Key Plan: included Name and contact information of applicant and property owner: not included Property limits: included including bearings and dimensions: not included Existing and proposed structures and parking areas: included Easements, road widening and rights-of-way: included Adjacent street names: included Development Servicing Report: Water Confirm consistency with Master Servicing Study, if available: not applicable Availability of public infrastructure to service proposed development: see page 2 of Servicing Brief Identification of system constraints: see page 2 of Servicing Brief Confirmation of adequate domestic supply and pressure: see page 2 of Servicing Brief 7

Confirmation of adequate fire flow protection and confirmation that fire flow is calculated as per the Fire Underwriter s Survey. Output should show available fire flow locations throughout the development: see page 2 of Servicing Brief Provide a check of high pressures. If pressure is found to be high, an assessment is required to confirm the application of pressure reducing valves: see page 2 of Servicing Brief Definition of phasing constraints. Hydraulic modeling is required to confirm servicing for all defined phases of the project including the ultimate design: not applicable Address reliability requirements such as appropriate location of shut-off valves: not applicable Check on the necessity of a pressure zone boundary modification:. not applicable Reference to water supply analysis to show that major infrastructure is capable of delivering sufficient water for the proposed land use. This includes data that shows that the expected demands under average day, peak hour and fire flow conditions provide water within the required pressure range: not applicable Description of the proposed water distribution network, including locations of proposed connections to the existing systems, provisions for necessary looping, and appurtenances (valves, pressure reducing valves, valve chambers, and fire hydrants) including special metering provisions: not applicable Description of off-site required feedermains, booster pumping stations, and other water infrastructure that will be ultimately required to service proposed development, including financing, interim facilities, and timing of implementation: not applicable Confirmation that water demands are calculated based on the City of Ottawa Design Guidelines: see page 2 of Servicing Brief Provision of a model schematic showing the boundary conditions locations, streets, parcels, and building locations for reference: not applicable Development Servicing Report: Wastewater Summary of proposed design criteria: see page 3 of Servicing Brief (Note: Wet-weather flow criteria should not deviate from the City of Ottawa Sewer Design Guidelines. Monitored flow data from relatively new infrastructure cannot be used to justify capacity requirements for proposed infrastructure): not applicable Confirm consistency with Master Servicing Study and /or justification for deviations: not applicable Consideration of local conditions that may contribute to extraneous flows that are higher than the recommended flows in the guidelines. This includes groundwater and soil conditions, and age and conditions of sewers: not applicable Descriptions of existing sanitary sewer available for discharge of wastewater from proposed development: see page 3 of Servicing Brief Verify available capacity in downstream sanitary sewer and / or identification of upgrades necessary to service the proposed development. (Reference can be made to previously completed Master Servicing Study if applicable): not applicable Calculations related to dry-weather and wet-weather flow rates from the development in standard MOE sanitary sewer design table (Appendix C) format. see page 5 of Servicing Brief Description of proposed sewer network including sewers, pumping stations, and forcemains: see page 3 of Servicing Brief Discussion of previously identified environmental constraints and impact on servicing (environmental constraints are related to limitations imposed on the development in order to preserve the physical condition of watercourses, vegetation, soil cover, as well as protecting against water quantity and quality): not applicable Pumping stations: impacts of proposed development on existing pumping stations or requirements for new pumping station to service development: not applicable 8

Forcemain capacity in terms of operational redundancy, surge pressure and maximum flow velocity: not applicable Identification and implementation of the emergency overflow from sanitary pumping stations in relation to the hydraulic grade line to protect against basement flooding: not applicable Special considerations such as contamination, corrosive environment etc: not applicable Development Servicing Report: Stormwater Checklist Description of drainage outlets and downstream constraints including legality of outlets (i.e. municipal drain, right-of-way, watercourse, or private property): see page 3 of Servicing Brief Analysis of available capacity in existing public infrastructure. not applicable A drawing showing the subject lands, its surroundings, the receiving watercourse, existing drainage patterns, and proposed drainage pattern: see drawing SG-1 Water quality control objective (e/g/ controlling post-development peak flows to pre-development level for storm events ranging from the 2 or 5 year event (dependent on the receiving sewer design) to 100 year return period); if other objectives are being applied, a rationale must be included with reference to hydrologic analyses of the potentially affected subwatersheds, taking into account long-term cumulative effects: see Stormwater Management Report Water Quality control objective (basic, normal or enhanced level of protection based on the sensitivities of the receiving watercourse) and storage requirements: see Stormwater Management Report Descriptions of the references and supporting information. Set-back from private sewage disposal systems. not applicable Watercourse and hazard lands setbacks: not applicable Record of pre-consultation with the Ontario Ministry of Environment and the Conservation Authority that has jurisdiction on the affected watershed: an email has been sent to MOE but the pre-application consultation record is not yet been issued Confirm consistency with sub-waterched and Master Servicing Study, if applicable study exists: not applicable Storage requirements (complete with calculations) and conveyance capacity for minor events (1:5 year return period) and major events (1:100 year return period). see drawing SG-1 & SG-2 and Stormwater Management Report Identification of watercourses within the proposed development and how watercourses will be protected, or, if necessary, altered by the proposed development with applicable approvals. see drawing SG-1 & SG-2 and Stormwater Management Report Calculate pre and post development peak flow rates including a description of existing site conditions and proposed impervious areas and drainage catchments in comparison to existing conditions: see Stormwater Management Report Any proposed diversion of drainage catchment areas from one outlet to another. : not applicable Proposed minor and major systems including locations and sizes of stormwater trunk sewers, and stormwater management facilities. : not applicable If quantity control is not proposed, demonstration that downstream system has adequate capacity for the post-development flows up to and including the 100-year return period storm event: not applicable Identification of potential impacts to receiving watercourses: see Stormwater Management Report Identification of municipal drains and related approval requirements. : not applicable Descriptions of how the conveyance and storage capacity will be achieved for the development: see page 3 of Servicing Brief 100 year flood levels and major flow routing to protect proposed development from flooding for establishing minimum building elevations (MBE) and overall grading: Inclusion of hydraulic analysis including hydraulic grade line elevations. : not applicable 9

Description of approach to erosion and sediment control during construction for the protection of receiving watercourses of drainage corridors: see notes 2.1 to 2.4 on drawing SG-2 Identification of floodplains proponent to obtain relevant floodplain information from the appropriate Conservation Authority. The proponent may be required to delineate floodplains elevations to the satisfaction of the Conservation Authority if such information is not available or if information does not match current: not applicable Identification of fill constraints related to floodplain and geotechnical investigation. : not applicable Approval and Permit Requirements: Checklist The Servicing Study shall provide a list of applicable permits and regulatory approvals necessary for the proposed development as well as the relevant issues affecting each approval. The approval and permitting shall include but not be limited to the following: Conservation Authority as the designated approval agency for modification of floodplain, potential impact on fish habitat, proposed works in or adjacent to a watercourse, cut/fill permits and Approval under Lakes and Rivers Improvement Act. The Conservation Authority is not approval authority for the Lakes and Rivers Improvement Act. Where there are Conservation Authority regulations in place, approval under the Lakes and Rivers Improvement Act is not required, except in cases of dams as defined in the Act: the Rideau Conservation Authority has not been contacted Application for Certificate of Approval (CofA) under the Ontario Water Resources Act: Changes to Municipal Drains. : not applicable Other permits (National Capital commission, Parks Canada, public Works and Government Services Canada, Ministry of transportation etc.) : not applicable Conclusion Checklist Clearly stated conclusions and recommendations: see page 3 of Servicing Brief Comments received from review agencies including the City of Ottawa and information on how the comments were addressed. Final sign-off from the responsible reviewing agency. All draft and final reports shall be signed and stamped by a professional Engineer registered in Ontario: included 10