ASTM D % 8.02% NA 1223 NA for App. Usage NA for App. Usage. NA for App. Usage. NA for App. Usage. NA for App.

Similar documents
ASTM D % 9.21% NA 1302 NA for App. Usage NA for App. Usage. NA for App. Usage. NA for App. Usage. NA for App.

Geogrid Soil Reinforcement

DETERMINATION OF THE LONG TERM PROPERTIES FOR MIRAFI PET-SERIES REINFORCEMENT GEOTEXTILES BY GRI-GT7 AND NCMA GUIDELINES

GRI Standard Practice GG4(a) * "Determination of the Long-Term Design Strength of Stiff Geogrids"

GRI Standard Practice GG4(b) * "Determination of the Long-Term Design Strength of Flexible Geogrids"

CITY OF FARGO SPECIFICATIONS GEOTEXTILES AND GEOGRIDS

2010 NTPEP Report Series

Section Specification for Geogrid Base Reinforcement of Flexible Pavement Structures

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012

AT SYNTEEN OUR PEOPLE KNEW THAT IN ORDER TO OFFER A BETTER GEOGRID WE NEEDED TO MAKE IT OURSELVES.

DETERMINATION OF THE LONG-TERM PROPERTIES FOR MIRAGRID XT GEOGRIDS

SECTION MECHANICALLY STABILIZED EARTH 1.01 SUMMARY

* Please use and submit the revised product specifications and revised price proposal with your bid submission.

Basal Reinforcement Constructing embankments over weak ground

STANDARDIZATION IN GEOTECH SECTOR V.K.PATIL

Quality Control, Quality Assurance and Performance Testing of ECPs. Erosion. Erosion Control

Reinforcement of Base Courses with Geogrids - Related Issues

2014 NTPEP Report Series

StrataGrid Construction and Overview of Manufacturing

Geosynthetics Product & Application Quick Reference Guide

Wmega Retaining Wall Specification

TriNet Coconut EROSION CONTROL BLANKET SPECIFICATION

TriNet Coconut EROSION CONTROL BLANKET SPECIFICATION

Sea to Sky Geotechnique 2006

SECTION MECHANICALLY STABILIZED EARTHEN SLOPES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Geosynthetics and Reinforced Soil Structures

Use of Polymer Geogrid Composite to support rail track over weak saturated clay subgrade a case study

SECTION SPECIFICATION FOR MECHANICALLY STABILIZED EARTH TWO STAGE WALL SYSTEM

GRI - GM13 Standard Specification*

BIAXIAL GEOGRID REINFORCEMENT

2016 NTPEP Report Series

SECTION ASPHALT INTERLAYER REINFORCEMENT SYSTEM. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

GEOSYNTHETICS FOR CIVIL ENGINEERING APPLICATIONS

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

FINAL REPORT: CONNECTION STRENGTH TESTING TENSAR GEOGRIDS WITHIN MESA STANDARD BLOCKS AND MESA STANDARD CONNECTORS

SPECIFICATION FOR GALVANIZED STEEL WIRE FORMED, STONE FILLED MECHANICALLY STABILIZED EARTH RETANING WALL

GRI Standard GS-15* Test Methods, Test Properties and Testing Frequency for Geocells Made From High Density Polyethylene (HDPE) Strips

2009 NTPEP Report Series

Flexamat Erosion Control Mat

Test Charges (Rs.) per Sample GEOTEXTILES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

These products are designed for reinforcement and characterized by integrally connected elements separated by in-plane apertures.

Flexamat Tied Concrete Block Mats

TENSILE CREEP BEHAVIOR OF A PVC COATED POLYESTER GEOGRID AT DIFFERENT TEMPERATURES

MATERIAL SPECIFICATION Manufactured Ditch Checks

Curlex Enforcer EROSION CONTROL BLANKET SPECIFICATION

SECTION ( ) MODULAR CONCRETE RETAINING WALL SYSTEM WEATHERED MULTI SHAPE 8 (203mm) HIGH UNITS

Drop-In Specification Standard Flexamat Erosion Control System (English Units)

Geosynthetic Materials for Separation and Stabilization

WOVEN POLYESTER HIGH PERFORMANCE GEOGRID ACEGrid the proven choice for:

WOVEN POLYESTER HIGH PERFORMANCE GEOGRID ACEGrid the proven choice for:

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Test Method GM21

TerraStop High Strength Woven Woven Range

QUALITY ASSESSMENT OF GEOGRIDS USED FOR SUBGRADE TREATMENT

GRI-GM22 GM22 Specification Reinforced Polyethylene Geomembranes for Exposed Temporary Applications

TECHNICAL DATA SHEET. Solmax HDPE Reflective Smooth - Imperial Values SPECIFICATIONS PROPERTY TEST FREQUENCY (1) UNIT. Solmax 460W-1000.

Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION

GEOSYNTHETICS. Geosynthetics Product & Application Specification Guide. (317)

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

LONG-TERM PERFORMANCE BY REDUCTION FACTORS OF GEOSYNTHETICS FOR WASTE LANDFILLS BEFORE/AFTER INSTALLATION

CONCRETE SEGMENTAL RETAINING WALLS

Changing the way you think about concrete Milliken

GRI - GM17 Standard Specification*

TABLE OF WOVEN GEOTEXTILE VALUES APPROVED GEOSYNTHETIC PRODUCTS (WOVEN GEOTEXTILE) APPLICATION AND PROPERTIES

ACE GEOGRIDS ACEGRID GEOGRIDS FOR REINFORCED SOIL EMBANKMENTS

CASE HISTORY REINFORCED SOIL WALL FOR MONSOON PALACE, AAMBY VALLEY. Reinforced Soil Wall for Monsoon Palace, Aamby Valley.

IMPROVEMENT OF SOIL BEARING CAPACITY USING GEOSYNTHETICS

Geosynthetics Product & Application Quick Reference Guide

INSTALLATION AND ENGINEERING MANUAL

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI GRI - GM22

EB601 MANUFACTURING QUALITY CONTROL (MQC) PROGRAM FOR GEOSYNTHETIC PRODUCTS

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI GRI-GCL3*

Address: 2500 Northwinds Parkway, Suite 500 Alpharetta, GA 30009

Geosynthetic Research Institute. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GRI Test Method GM13*

Fortrac. Immensely Versatile Solutions for Reinforced Soil

HIGH STRENGTH GEOGRIDS FOR BASAL REINFORCEMENT. 49th Annual Southeastern Transportation Geotechnical Engineering Conference - (STGEC)

Connection Strength Criteria for Mechanically Stabilized Earth Walls

Geosynthetics. Nanjundaswamy P. Dept. of Civil Engineering S J C E, Mysore

APPENDIX D. MATERIAL TEST RESULTS

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

AEC Premier Straw Double Net Quick Mow EROSION CONTROL BLANKET SPECIFICATION

Curlex High Velocity EROSION CONTROL BLANKET SPECIFICATION

SPECIFICATION FOR SEGMENTAL RETAINING WALLS Mesa Retaining Wall System

Bearing Capacity of Footing on Reinforced Flyash Slope

Geosynthetics. continued. Prof K. Rajagopal. IIT Madras, Chennai

Curlex II EROSION CONTROL BLANKET SPECIFICATION

HUESKER. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKERHUES

Large-Scale Channel Erosion Testing (ASTM D 6460) (Modified procedure used for vegetated channel tests)

Roads and Bridges Agrément Certificate No 99/R113 PRODUCT SHEET 1 TENSAR RE GEOGRIDS FOR REINFORCED SOIL EMBANKMENTS

Large-Scale Channel Erosion Testing (ASTM D 6460) (Modified procedure used for vegetated channel tests)

ACE GEOGRIDS ACEGRID GEOGRIDS FOR BASAL REINFORCEMENT

TENDER SPECIFICATIONS SPECIFICATION FOR SUPPLY OF TECHGLASS AIC GEO-COMPOSITE (ASPHALT INTERLAYER GEO-COMPOSITE)

Regulations Detail Sheet 1

Tenax Geogrids. Soil Reinforcement Solutions. Geosynthetics Limited

NTPEP REGEO Summary of Survey Results Use of the NTPEP REGEO Program and Installation damage Protocol Issues June 2014

ARMORMAX ENGINEERED EARTH ARMORING SOLUTIONS

596TW kcmil Type 13, 3M Brand Composite Conductor Compression Connector Qualification - Tensile, Sustained Load, and High-temperature Sustained Load

Vegetated Large-Scale Channel Erosion Testing (ASTM D 6460) (Modified procedure used for vegetated channel tests)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Transcription:

REINFORCEMENT GEOGRID - APL Company: Contech Engineered Solutions, LLC Date: 1/8/216 Product: E'GRID RX12 by Contech Contact Person: Robert Morris Phone/email: 44-391-7615, rmorris@conteches.com Material Description: Biaxial Geogrid ATTACH CERTIFIED INDEPENDENT TEST RESULTS TO JUSTIFY SUBMITTED VALUES PROPERTY REQUIRED TEST METHOD UV Stability (Min. Retained Strength at 5 hrs.) Tensile Strength (lbs/ft) ASTM D 4355 94% Machine Direction Ultimate (T ult ) 2% Strain 5% Strain ASTM D 6637 1315 411 88 Cross Direction Ultimate 2% Strain 5% Strain 1973 616 1343 Strain at Ultimate Tensile Strength Secant Modulus (lbs/ft) 2% Strain 5% Strain 1% Strain Junction Strength (lbs/ft) GRI : GG2 Soil - Geosynthetic Friction ASTM D 676 Creep Resistance T creep (lb/ft) ASTM D 5262 Creep Reduction Factor (T ult /T creep ) ASTM D 6637 8.2% 255 1616 NA 1223 Installation Damage (RF C ) Sand Limerock Fill GRI : GG4 & GT7 Durability (RF D ) Joint Strength (RF J ) Chemical ASTM D 5322 Biological ASTM D 1987 & G21 Mechanical ASTM D 6637, GRI : GG4 & GT7 Overlap (3 feet Min) ASTM D 676 Requested Application Usage R5 R-1 R-2 R-3 R-4 R-5 Geosynthetic Reinforced Embankment GRS-IBS Reinforcement of Foundations over Soft Soils PPM (See Ch.31) Steepened Slopes PPM (See Ch.31) Reinforced Embankment SFH (App. E) Construction Expedient

May 28, 214 June 5, 214 June 9, 214 Mail To: Updated with Junction Retest result and Pitch size direction revised. Updated with UV Resistance results Bill To: Attn: John Price Hanes Geo Components 815 Buxton Street Winston-Salem, North Carolina 2711 <= Same email: john.price@hanescompanies.com Dear Mr. Price: Thank you for consulting TRI/Environmental, Inc. (TRI) for your geosynthetics testing needs. TRI is pleased to submit this final report of the laboratory testing for the sample(s) listed below. TRI Job Reference Number: Material(s) Tested: E239-5-2 Seven Geogrid(s) Test(s) Requested: Single Rib Tensile Properties (ASTM D 6637, Method A) Mass/Unit Area (ASTM D 5261) Junction/Node Strength (ASTM D7737, mod.) Aperature Size (Calipers) Rib Pitch (Calipers) Carbon Black Content (ASTM D 163, Two Burn) Thickness (Micrometer) - Rib & Junction/Node Flexural Rigidity (ASTM D 7748) Percent Open Area (COE Method) Updated====> UV Resistance (ASTM 4355 ) If you have any questions or require any additional information, please call us at 1-8-88-8378 Sincerely, Mansukh Patel Laboratory Manager Geosynthetic Services Division www.geosynthetictesting.com Page 1 of 18

GEOGRID TEST RESULTS TRI Client: Hanes Geo Components Material: Terragrid 12 Geogrid Sample Identification: RX 12, Roll 455, Batch 131181 TRI Log #: E239-5-2 STD. PARAMETER TEST REPLICATE NUMBER MEAN DEV. 1 2 3 4 5 6 7 8 9 1 Single Rib Tensile Properties (ASTM D 6637, Method A) MD - Number of Ribs per foot: 7.7 MD Maximum Strength (lbs) 183 192 28 182 23 193 12 MD Maximum Strength (lbs/ft) 147 1476 1599 14 1562 1489 9 MD Maximum Strength (kn/m) 2.5 21.6 23.3 2.4 22.8 21.7 1.3 MD Strength @ 1% Strain (lbs) 59.6 59.8 66.5 6.9 63.9 62.1 3. MD Strength @ 1% Strain (lbs/ft) 459 461 512 469 492 479 23 MD Strength @ 1% Strain (kn/m) 6.7 6.72 7.48 6.85 7.18 6.99.34 MD Strength @ 2% Strain (lbs) 94.7 95.1 99.4 95.3 97.9 96.5 2.1 MD Strength @ 2% Strain (lbs/ft) 73 732 766 734 754 743 16 MD Strength @ 2% Strain (kn/m) 1.7 1.7 11.2 1.7 11. 1.9.2 MD Strength @ 5% Strain (lbs) 144 148 146 148 146 146 2 MD Strength @ 5% Strain (lbs/ft) 118 1141 1124 1139 1128 1128 13 MD Strength @ 5% Strain (kn/m) 16.2 16.7 16.4 16.6 16.5 16.5.2 MD Strength @ 1% Strain (lbs) 154 16 158 159 156 157 2 MD Strength @ 1% Strain (lbs/ft) 1184 1229 1215 1224 124 1211 18 MD Strength @ 1% Strain (kn/m) 17.3 17.9 17.7 17.9 17.6 17.7.3 MD Break Elongation (%) 27. 28.9 33.2 24.2 33.1 29.3 3.9 TD - Number of Ribs per foot: 1.2 TD Maximum Strength (lbs) 29 22 29 22 222 216 7 TD Maximum Strength (lbs/ft) 2137 2252 2138 2251 2272 221 67 TD Maximum Strength (kn/m) 31.2 32.9 31.2 32.9 33.2 32.3 1. TD Strength @ 1% Strain (lbs) 53.8 56.6 61. 66.4 68.9 61.3 6.3 TD Strength @ 1% Strain (lbs/ft) 55 579 624 678 74 627 65 TD Strength @ 1% Strain (kn/m) 8.3 8.45 9.11 9.9 1.3 9.15.95 TD Strength @ 2% Strain (lbs) 93.2 97.2 1 16 19 11 6 TD Strength @ 2% Strain (lbs/ft) 953 993 119 181 1117 133 66 TD Strength @ 2% Strain (kn/m) 13.9 14.5 14.9 15.8 16.3 15.1 1. TD Strength @ 5% Strain (lbs) 169 175 175 183 187 178 7 TD Strength @ 5% Strain (lbs/ft) 1729 1793 1784 1869 1916 1818 74 TD Strength @ 5% Strain (kn/m) 25.2 26.2 26. 27.3 28. 26.5 1.1 TD Strength @ 1% Strain (lbs) 22 22 TD Strength @ 1% Strain (lbs/ft) 1691 1691 TD Strength @ 1% Strain (kn/m) 24.7 24.7 TD Break Elongation (%) 8.2 1.3 8.57 8.32 8.33 8.71.92 Mass/Unit Area (ASTM D 5261) Mass/unit area (oz/sq.yd) 7.96 7.96 8.1 7.99 7.92 8.1 7.99 7.99 7.92 8.6 7.98.4 MD Machine Direction TD Transverse Direction Page 4 of 18

GEOGRID TEST RESULTS TRI Client: Hanes Geo Components Material: Terragrid 12 Geogrid Sample Identification: RX 12, Roll 455, Batch 131181 TRI Log #: E239-5-2 STD. PARAMETER TEST REPLICATE NUMBER MEAN DEV. 1 2 3 4 5 6 7 8 9 1 Junction/Node Strength (ASTM D7737, mod.via 1% Strain Rate as requested by client) MD - Number of Ribs per foot: 7.7 MD Maximum Junction Strength (lbsf) 172 177 175 178 183 188 185 21 194 178 183 9 MD Maximum Junction Strength (lbs/ft) 1325 1366 135 1372 146 1447 1426 1549 1497 1371 1411 7 MD Maximum Junction Strength (kn/m) 19.4 19.9 19.7 2. 2.5 21.1 2.8 22.6 21.9 2. 2.6 1. TD - Number of Ribs per foot: 1.2 TD Maximum Junction Strength (lbsf) 25 22 24 23 25 27 21 197 195 25 22 4 TD Maximum Junction Strength (lbs/ft) 292 26 281 278 299 2116 253 213 1989 295 267 4 TD Maximum Junction Strength (kn/m) 3.5 3.1 3.4 3.3 3.6 3.9 3. 29.4 29. 3.6 3.2.6 MD Junction Efficiency (%) 95 TD Junction Efficiency (%) 94 Center of Junction node to center of clamped node is considered as gage length, MD : 2.3 inch and TD :3. inch Aperature Size (Calipers) MD - Aperature Size (in) 1.55 1.79 1.75 1.81 1.81 1.35 1.76 1.46 1.81 1.42 1.65.18 TD - Aperature Size (in) 1.443 1.463 1.459 1.466 1.448 1.453 1.443 1.455 1.462 1.458 1.455.8 Rib Pitch (Calipers) MD - Pitch (in) 1.567 1.59 1.61 1.61 1.571 1.597 1.573 1.59 1.576 1.578 1.584.13 TD - Pitch (in) 1.224 1.228 1.191 1.184 1.195 1.177 1.212 1.242 1.259 1.241 1.215.28 Carbon Black Content (ASTM D 163, Two Burn) Percent Carbon Black Content with Ash(%):.94.92.93.1 Percent Ash Content (%):.3.3.3. Percent Carbon Black Content without Ash(%):.9.89.89.1 MD Machine Direction TD Transverse Direction Page 5 of 18

Hanes Geo Components, RX 12, MD,Roll# 455, Batch # 131181 Single RibTensile, ASTM D 6637,Method A, TRI Log # E 239-5-2 Tensile Strength (lb/ft) 16 14 12 1 8 6 4 2 2 4 6 8 1 12 14 16 18 2 22 24 26 28 Tensile Strain (%) RX12 -MD-1 RX12-MD-2 RX12-MD-3 RX12-MD-4 RX12-MD-5 25 Hanes Geo Components, RX 12, TD,Roll# 455, Batch # 131181 Single RibTensile, ASTM D 6637,Method A, TRI Log # E 239-5-2 Tensile Strength (lb/ft) 2 15 1 5 2 4 6 8 1 12 Tensile Strain (%) RX12 -TD-1 RX12-TD-2 RX12-TD-3 RX12-TD-4 RX12-TD-5 Page 13 of 18

Hanes Geo Components, RX12, MD,Roll# 455, Batch # 131181 Junction Strength, ASTM D 7737,Mod.1% Strain Rate, TRI Log # E 239-5-2 Junction Strength (lbs) 24 22 2 18 16 14 12 1 8 6 4 2 2 4 6 8 1 12 14 16 18 2 22 24 26 RX12 -MD-1 RX12-MD-2 RX12-MD-3 RX12-MD-4 RX12-MD-5 RX12-MD-6 RX12-MD-7 RX12-MD-8 RX12-MD-9 RX12-MD-1 Junction Strain (%) Hanes Geo Components, RX12, TD,Roll# 455, Batch # 131181 Junction Strength, ASTM D 7737,Mod.1% Strain Rate, TRI Log # E 239-5-2 Junction Strength (lbs) 225 2 175 15 125 1 75 5 25 1 2 3 4 5 6 7 8 9 1 11 12 Junction Strain (%) RX12 -TD-1 RX12-TD-2 RX12-TD-3 RX12-TD-4 RX12-TD-5 RX12-TD-6 RX12-TD-7 RX12-TD-8 RX12-TD-9 RX12-TD-1 Page 14 of 18

BOSTD Geosynthetics Qingdao Ltd. Suite D-7A, Majestic Garden No 6 Middle of Beisihuan Road Beijing 129, China November 4, 215 Attention: To whom it may concern Subject: Certification that the resin formulation for E GRID RX12 is identical to the resin formulation for Terragrid (E GRID) RX11 To whom it may concern: By this letter, BOSTD Geosynthetics Qingdao Ltd. certifies that the resin formulation and amount carbon black added to produce E GRID RX11 and RX12 geogrids is identical to the resin formulation and amount of carbon black added to produce Terragrid (E GRID) RX11 (Product also produced by BOSTD and tested for UV durability per ASTM D4355 - See Results included with E GRID RX11 Submittal) and has not changed since the date of the ASTM D4355 test provided. Therefore, it is reasonable to conclude that E GRID RX11 and RX12 will exhibit equivalent UV resistance when tested in accordance ASTM D4355. Sincerely, BOSTD Geosynthetics Qingdao Ltd.