Tube Insulation. Fiber Free

Similar documents
PRODUCT SELECTION GUIDE

We solved the science of safely insulating air ducts.

Armacell Product Selection Guide

We solved the science of safely insulating air ducts.

The Right Insulation for Cold Systems

The Right Insulation for Indoor Air Quality

GUIDE SPECIFICATION: DUCT LINER

TOTALINE COPPER TUBING

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1

Standard and Mini Split Line Sets

Aluminum Lagging Roll Jacketing Fittings

Chilled Water. Product performance for insulation of chilled water piping

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT

K-FLEX DUCT LINER GRAY

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

Ammonia. Product performance for insulation of ammonia piping

Master Insulation Guide Specification for Mechanical Systems

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips.

ARIFLEX. Rubber Insulation Foam Tube & Foam Sheet

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

SECTION PIPING INSULATION

FIRE STATION 55 June 14, 2010

SECTION HVAC INSULATION

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE

15402 Vantage Parkway East, Suite 322 Houston, Texas

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

Insulation engineered to prevent condensation and energy loss

RELIABLE, FLEXIBLE INSULATION TRUSTED TO PREVENT CONDENSATION

Design & Construction Standards, Revised January

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

Redi-Klad 1000 Pipe Insulation

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

ARCHITECT S GUIDE: Filled Cavity Systems for Metal Buildings

SECTION PRE-ENGINEERED BUILDING INSULATION

EFRIGERATION INSTALLATION GUIDE

Product Guide Specification

B. Refer to Section : Air Distribution for lined ductwork requirements.

CertainTeed DRYRIGHT. Moisture Control Fiber Glass Insulation

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION

SECTION DUCT INSULATION

Guide Specification SECTION DUCT INSULATION

Thermasheath-XP. Insulation for Exposed Use

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

ENGINEERED INSULATION TO PREVENT CONDENSATION AND ENERGY LOSSES

ENGINEERED INSULATION TO PREVENT CONDENSATION AND ENERGY LOSSES

Expanded Polystyrene DataSheet

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

Pipe & Equipment Insulations Product Selection Guide

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

Thermal Insulation. Physically Crosslinked closed cell polyolefin foam insulation for ducts PHYSICALLY SEKISUI TECHNOLOGY

Earthwool Redi-Klad 1000 Pipe Insulation

SUPAFLEX SUPAFLEX DESCRIPTION TUBING:

6747 Campobello Road Mississauga, Ontario, Canada

HALO EXTERRA MATERIAL PROPERTY DATA SHEET rev

University of Delaware

SECTION SPRAY FOAM INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

Praval Adhaulia K-FLEX INDIA PVT LTD

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology

SECTION HVAC PIPING INSULATION

LEED POINT ELIGIBLE, AIRTIGHT GREEN POINT CONTRIBUTORS SHURTAPE.COM TAPE

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

Closed cell expanded polystyrene (EPS) insulation with graphite.

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS

Tel: Fax:

OptiLiner Banded Liner System, Thermal, Metal Building

BuildingName The Description of the Project P DOCUMENTS

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

1 of 17. PO Box Bellevue Rd, Newark, DE V F

APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents

SECTION MECHANICAL INSULATION

Proof positive. The Science Behind the System.

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT

THERMAL BATT INSULATION COMFORTBATT. Thermal Batt Insulation for Residential & Commercial Construction.

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

PRODUCT SELECTION GUIDE. HVAC Insulation

PERMATHERM PIPE INSULATION PRODUCTS

ArmAcell solutions for systems refrigeration, Air- conditioning & VeNtilAtioN

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

O82018 Hunter Panels XCI Foil

Phenolic Foam (PF) Insulation

Transcription:

Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications Closed-cell structure provides excellent condensation and energy loss control Effectively retards degradation due to ultraviolet radiation Flexible material with dusted, relaxed ID s for easy installation. Superior toughness to withstand on-site handling Built-in vapor retardant barrier eliminates need for additional vapor retarder

Technical Data: AC Accoflex Pipe Insulation Description: Black flexible elastomeric thermal pipe insulation Specifications Compliance: ASTM C 534, Type I - Tubular Grade 1 Approvals, Certifications, Compliances: Manufactured without CFCs, HFCs, HCFCs, PBDEs, or Formaldehyde. All Armacell facilities in North America are ISO 9001:2008 certified. Typical Properties Specifications: Values Test Method: Thermal Conductivity: Btu in./h ft 2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) Water Vapor Permeability: Perm-in. [Kg/(s m Pa)] Flame Spread and Smoke Developed Index: Water Absorption, % by Volume: Mold Growth: Fungi Resistance : Bacterial Resistance: 0.27 (0.039) ASTM C 177 or C 518 0.276 (0.040) 0.08 (1.16 x 10-13 ) ASTM E 96, Procedure A 25/50 rated ASTM E 84 0.2% ASTM C 209 Passed UL181 ASTM G21/C1338 ASTM G22 Upper Use Limit: 1 220 F (105 C) ASTM C534 Lower Use Limit: 2-297 F (-183 C) 3 ASTM C534 Ozone Resistance: GOOD Sizes: Wall Thickness (nominal) 3/8" 1/2", 3/4" and 1" (10, 13, 19 and 25 mm) Inside Diameter, Tubular 3/8", ID to 4-1/8" ID (10 mm ID to 105 mm ID) Length of Sections, Tubular 6' (1.83 m) Outdoor Use No painting is necessary for performance of the product. However, all elastomeric-based cellular insulation will show surface defects after prolonged exposure to UV radiation. Painting will minimize these defects if installed outdoors. 1 AC Accoflex can withstand temperatures as high as 250 F for 96 hour time periods when tested according to ASTM C411 - Standard Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation. 2 At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Accoflex insulation. 3 For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell. ARMACELL LLC TEL: 800.866.5638 FAX: 919.304.3847 info.us@armacell.com www.armacell.us 7600 Oakwood Street Extension, Mebane, NC 27302 Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. AC Accoflex Submittal 006 Eng/USA 9/2015 2015 Armacell LLC. Printed in United States of America

Fiber Free Tube Insulation with Reinforced Lap Seal The original flexible elastomeric pipe insulation with a new and improved lap seal for greater seam security and increased protection against condensation, mold and energy loss. Angled cut with more surface area for a better bond A single interior adhesive liner for quicker application New durable, low-profile lap seal with wider release tab, stays closed and looks neat Easy to install an excellent choice for retrofit applications 25/50 rated for use in air plenums Fiber-free, formaldehyde-free, low VOC and nonparticulating formulation protects indoor air quality Microban antimicrobial product protection inhibits the growth of mold and mildew in the insulation GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. Microban antimicrobial product protection is limited to the product itself and is not designed to protect the users of these products from disease causing microorganisms, or as a substitute for normal cleaning and hygiene practices.*

Technical Data: AP Armaflex Black LapSeal Tube Insulation Description: Black flexible closed-cell elastomeric thermal insulation in tubular form with a self-seal system reinforced with lap seal tape Applications: Insulation for piping associated with HVAC, VRV and VRF systems, chillers, hot and cold water, refrigeration Specifications Compliance: ASTM C 534, Type I Grade 1 ASTM E 84 NFPA 255 UL 723 NFPA 90A, 90B UL 181 ASTM G-21/C1338 ASTM G-22 ASTM D 1056, 2B1 Approvals, Certifications, Compliances: Key physical properties are approved by Factory Mutual. GREENGUARD Gold Certified. Manufactured without CFCs, HFCs, HCFCs, PBDEs, or Formaldehyde. Made with EPA registered Microban antimicrobial product protection.. All Armacell facilities in North America are ISO 9001:2008 certified. Typical Properties Specifications: Values: Test Method: 3/8" through 1" Walls 1-1/2" and 2" Walls Thermal Conductivity: Btu in./h ft 2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) Water Vapor Permeability: Perm-in. [Kg/(s m Pa)] Flame Spread and Smoke Developed Index: 0.245 (0.0353) 0.254 (0.0366) 0.28 (0.040) 0.286 (0.041) ASTM C 177 or C 518 0.05 (0.725 x 10 13 ) 0.08 (1.16 x 10 13 ) ASTM E 96, Procedure A 25/50 rated 25/50 rated ASTM E 84 Water Absorption, % by Volume: 0.2% 0.2% ASTM C 209 Mold Growth: Fungi Resistance: Bacterial Resistance: Passed Passed UL181 ASTM G21/C1338 ASTM G22 Upper Use Limit: 220 F (105 C) 220 F (105 C) ASTM C534 Lower Use Limit: 1-297 F (-183 C) 2-297 F (-183 C) 2 ASTM C534 Ozone Resistance: GOOD GOOD Ozone Chamber Test Sizes: Wall Thickness (nominal) Form Inside Diameter, Tubular Form Length of Sections, Tubular Form Outdoor Use 3/8", 1/2", 3/4", 1", 1-1/2", 2" (10 mm, 13 mm, 19 mm, 25 mm, 38 mm, 50 mm) 3/8"ID to 6" (10 mm to 153 mm) 6' (1.8m) Painting with WB Finish or other protective jacketing is required to prevent damage to the insulation in exterior applications and to comply with the insulation protection sections of the International Energy Conservation Code (IECC) and ASHRAE 90.1. 1 At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation. 2 For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell. ARMACELL LLC TEL: 800.866.5638 FAX: 919.304.3847 info.us@armacell.com www.armacell.us 7600 Oakwood Street Extension, Mebane, NC 27302 Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. * Microban antimicrobial product protection is limited to the product itself and is not designed to protect the users of these products from disease causing microorganisms, or as a substitute for normal cleaning and hygiene practices. Microban International, Ltd. makes neither direct nor implied health claims for the products containing Microban antimicrobial product protection. Data, photomicrographs and information presented are based on standard laboratory tests and are provided for comparative purposes to substantiate antimicrobial activity for non-public health uses. Microban is a registered trademark of Microban International, Ltd. AP Armaflex Black LapSeal Submittal 020 Eng/USA 5/2016 2016 Armacell LLC. Printed in United States of America

Tubular Foam Insulation Imcoa and Imcoa SS premium quality closed-cell polyethylene foam insulations are used in residential, commercial and industrial projects to prevent heat loss and protect pipes from freezing. Imcoa SS has an integrated self-sealing system that makes it quick and easy to install. APPLICATIONS Imcoa is used to retard heat loss on hot water pipes and prevent freezing of all water pipes. It is available in wall thicknesses of 3/8", 1/2", 3/4" and 1", in sizes ranging from 3/8" CTS to 4" IPS. Imcoa has a low thermal conductivity and very low water vapor transmission rate. This low density product demonstrates excellent thermal, physical and chemical resistant properties and has a broad service temperature range between -297 F and 200 F (-183 C and 93 C). It can be installed in commercial, industrial and residential insulation projects. It is acceptable for use with heat tracing/heat tape. BENEFITS Imcoa and Imcoa SS are fiber-free and 100% non-particulating polyethylene foam pipe insulation. Its closed-cell structure won t wick moisture and helps prevent the absorption of condensation that could cause mold to develop over time. Imcoa SS has an easy-to-install self-seal closure system. INSTALLATION Imcoa pipe insulation is semi-slit, and can be completely slit by hand. Imcoa SS is pre-slit with a factory applied pressure sensitive adhesive (PSA) to both seam surfaces and has a release liner for easy installation. All butt joints should be properly sealed. Imcoa and Imcoa SS are easy to cut with a knife and can be fabricated to go around P-traps and fittings. Features CFC/HCFC Free Non-porous Low VOCs Halogen Free Fiber Free Resistant to Mold Growth Made in USA Specification Compliance ASTM C-1427, Type 1, Grade 1 ASTM E 84 1 25/50 Specification Compliance ASTM C 1427, NFPA 90 A/B / Acceptable for use in duct/plenum applications Dade Co., Fl., Product Control Approved, Acceptance 95-1215.08 New York City OTCR #13-09 USDA Requirements Sound transmission co-efficient = 11 at 1" per ASTM E90 City of Los Angeles, Gen. Approval, Research Report RR 8316 Greenguard Gold Certified (formerly children & schools)

Technical Data: Imcoa and Imcoa SS Approvals, Certifications, Compliances: GREENGUARD Gold Certified. Manufactured without CFCs, HFCs, HCFCs, PBDEs, or Formaldehyde Plenum Rated Physical Properties Physical Properties Testing Parameters Imcoa Insulation Test Methods Thermal Conductivity (K) Btu in/hr ft 2 F (W/mK) Operating Temperature Range Flexible to -100 F (-73 C) 90 F (32 C) Mean Temperature 75 F (24 C) Mean Temperature 50 F (10 C) Mean Temperature Upper range Lower Range 0.280 (0.040) 0.275 (0.040) 0.270 (0.039) 200 F (93 C) -297 F (-183 C) ASTM C 177/C 518 Water Vapor Permeability Dry Cup. Perm-In 0.0 ASTM E 96 Procedure A Ozone Resistance Pass ASTM D 1171 Chemical / Solvent Resistance Good Mildew Resistance / Air Erosion Pass UL 181 Typical Properties Flame Spread and Smoke Developed Index through 1" (25 mm) thickness * 25/50 rated ASTM E 84 * Cellular plastics and thermoplastics, such as polyethylene/polyolefin insulation, that may drip, melt, delaminate or draw away from the fire, present unique problems and require careful interpretation of the test results. R-Values Pipe O.D. or Nominal R Value R Value R Value R Value Insulation I.D. 3/8" (10 mm) Wall 1/2" (13 mm) Wall 3/4" (19 mm) Wall 1" (25 mm) Wall 3/8" 10 mm 2.8 3.8 5.9 8.4 1/2" 13 mm 2.5 3.3 5.4 7.7 5/8" 16 mm 2.5 3.2 5.0 7.1 3/4" 19 mm 2.3 3.1 4.9 6.8 7/8" 22 mm 2.3 3.0 4.6 6.5 1-1/8" 29 mm 2.2 3.0 4.3 6.1 1-3/8" 35 mm 2.1 2.9 4.4 6.1 1-5/8" 41 mm 2.1 2.6 4.1 5.6 2" 50 mm 1.8 2.3 3.7 5.1 2-1/8" 54 mm 2.1 2.6 3.9 5.4 2-3/8" 62 mm 1.8 2.3 3.6 5.0 2-5/8" 67 mm 2.1 2.5 3.8 5.1 2-7/8" 72 mm 1.8 2.3 3.4 4.8 3-1/8" 79 mm 2.1 2.5 3.7 5.0 3-1/2" 89 mm 1.8 2.3 3.3 4.6 3-5/8" 92 mm 2.5 2.5 3.6 5.0 4-1/8" 105 mm 2.5 2.5 3.6 4.9 4-1/2" 115 mm 1.7 2.2 3.2 4.4 Note: R values were calculated using a K factor of 0.275 (75 F, 24 C mean temp.) and nominal all thickness in each case. Lower operating temperatures will result in improved R values. Contact Technical Services for specific recommendations. Sizes Wall Thickness (nominal) 3/8" 1/2", 3/4" and 1" (10, 13, 19 and 25 mm) Inside Diameter, Tubular 3/8" to 4" IPS ID (10 mm to 114 mm ID) Length of Sections, Tubular 6' (1.83 m) ARMACELL LLC TEL: 800.866.5638 FAX: 919.304.3847 info.us@armacell.com www.armacell.us 7600 Oakwood Street Extension, Mebane, NC 27302 Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. Imcoa and Imcoa SS Data Sheet 092 Eng/USA 3/2017 2017 Armacell LLC. Printed in United States of America