PRODUCT SELECTION GUIDE

Similar documents
Tube Insulation. Fiber Free

Armacell Product Selection Guide

We solved the science of safely insulating air ducts.

We solved the science of safely insulating air ducts.

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1

Chilled Water. Product performance for insulation of chilled water piping

Master Insulation Guide Specification for Mechanical Systems

TOTALINE COPPER TUBING

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips.

GUIDE SPECIFICATION: DUCT LINER

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT

Ammonia. Product performance for insulation of ammonia piping

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

The Right Insulation for Indoor Air Quality

Design & Construction Standards, Revised January

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

The Right Insulation for Cold Systems

SECTION PIPING INSULATION

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

RELIABLE, FLEXIBLE INSULATION TRUSTED TO PREVENT CONDENSATION

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

Insulation engineered to prevent condensation and energy loss

FIRE STATION 55 June 14, 2010

K-FLEX DUCT LINER GRAY

SECTION DUCT INSULATION

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment

HVAC INSULATION. A. General Requirements for Flexible Elastomeric Insulation: 3. Use pre-molded roll on pipe sizes 3.5" and below.

Aluminum Lagging Roll Jacketing Fittings

SECTION HVAC INSULATION

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

EFRIGERATION INSTALLATION GUIDE

ArmAcell solutions for systems refrigeration, Air- conditioning & VeNtilAtioN

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

Standard and Mini Split Line Sets

B. Refer to Section : Air Distribution for lined ductwork requirements.

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

University of Delaware

ARIFLEX. Rubber Insulation Foam Tube & Foam Sheet

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

SECTION HVAC PIPING INSULATION

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

ARMAFLEX SHEET AL / KY / AL-KY

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

ENGINEERED INSULATION TO PREVENT CONDENSATION AND ENERGY LOSSES

ENGINEERED INSULATION TO PREVENT CONDENSATION AND ENERGY LOSSES

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

THE FIRST CHOICE FOR PROFESSIONAL INSTALLATIONS

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

BuildingName The Description of the Project P DOCUMENTS

ARCHITECT S GUIDE: Filled Cavity Systems for Metal Buildings

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations

Pressure Sensitive Tapes for Industrial Insulation and General Purpose

Pipe & Equipment Insulations Product Selection Guide

THE PROFESSIONAL HIGH PERFORMANCE INSULATION FOR LONG TERM ENERGY SAVING TRUSTED SINCE 40 YEARS

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

PRODUCT SELECTION GUIDE. HVAC Insulation

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS

SECTION MECHANICAL INSULATION

THE FLEXIBLE & SUSTAINABLE INSULATION SYSTEM FOR ENERGY EFFICIENCY & CONDENSATION CONTROL - TRUSTED FOR OVER 40 YEARS

CUSH-A-THERM VAPOR BARRIER PROTECTION

SUPAFLEX SUPAFLEX DESCRIPTION TUBING:

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor

Redi-Klad 1000 Pipe Insulation

Thermasheath-XP. Insulation for Exposed Use

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT

This Design guideline contained herein includes the requirements for mechanical insulation at The University of Texas at Austin

Guide Specification SECTION DUCT INSULATION

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION

APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents

Quality NBR Insulation

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Thermal Insulation. Physically Crosslinked closed cell polyolefin foam insulation for ducts PHYSICALLY SEKISUI TECHNOLOGY

FOR DOMESTIC HEATING & PLUMBING PIPEWORK. The economic insulation for effective energy saving

SUPERIOR CAL-SHIELDS Features & Benefits FAST

SECTION PRE-ENGINEERED BUILDING INSULATION

FLEXIBLE MECHANICAL PROTECTION

Praval Adhaulia K-FLEX INDIA PVT LTD

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

HVAC Piping Insulation- FIBERGLAS Insulation

FIBRE-FREE DUCT INSULATION WITH A DURABLE AND AESTHETIC SILVER FINISH

K-FLEX Clad Jacketing. Jacketing Systems for Mechanical Insulation

THE FLEXIBLE INSULATION SYSTEM TO PREVENT CONDENSATION AND ENERGY LOSSES

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology

EXPLORE GEOMETRY AND SPACE

SECTION SPRAY FOAM INSULATION

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING

2013 COMMERCIAL PRODUCTS

THE COMPLETE POLYETHYLENE INSULATION PACKAGE FOR EFFECTIVE ENERGY SAVING AND ACOUSTIC PROTECTION

Transcription:

Fiber Free PRODUCT SELECTION GUIDE Quick guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. Microban antimicrobial product protection is limited to the product itself and is not designed to protect the users of these products from disease causing microorganisms, or as a substitute for normal cleaning and hygiene practices.*

All of Armacell s products are produced from flexible, fiber-free, elastomeric foam material which is low VOC and formaldehyde free. Each insulation option saves energy, is thermally efficient and moisture resistant by its nature. Our AP branded products Tube Products (Pipe Insulation) Select the original fiber-free tubular foam insulation for preventing energy waste and water vapor transmission. Available in regular unslit tubes and lap seal formats. AP Armaflex White and Black Tubes Original flexible, closed cell elastomeric tubes in black and white NH Armaflex Tubes Non-halogen tubes especially formulated for shipboard use are made with Microban antimicrobial protection, are GREENGUARD Gold certified and suitable for use in the air plenum. Because of its inherent durability and long life cycle, all of our products (when installed properly) should outlive fibrous installations which are susceptible to moisture, damage and fibrous degradation over time. Most Armacell product installations will prove to be long lasting, boosting investment pay-back and sustainability over the life of the system. 1 www.armacell.us AP Armaflex Black LapSeal Self-sealing tube insulation with reinforced lap seal AP Armaflex White LapSeal Self-sealing tube insulation with reinforced lap seal Armaflex Coil Continuous coil pipe insulation designed for labor savings and to minimize waste UT Solaflex 300 upper temperature insulation ideal for solar applications, hot gas piping and low pressure steam lines Tubolit & Tubolit SS Economical polyethylene insulation for plumbing lines AC Accoflex Flexible pipe insulation with UV radiation protection for commercial and residential applications

Sheet and Roll Products Choose sheet and roll insulation for mechanical systems, chillers, larger surfaces, tanks and fittings. Available in regular and self-adhering for both interior and exterior applications.* Adhesives & Coatings AP Armaflex & AP Armaflex FS Original fiber-free insulation for thermal applications 520 Adhesive & 520 Black Recommended adhesive specially formulated for Armaflex insulation AP Armaflex SA & AP Armaflex FS SA Fiber-free insulation for thermal applications in self-adhering format 520 BLV & Low VOC Spray Adhesive Low VOC adhesive alternatives NH Armaflex Nonhalogen sheet and roll insulation material especially formulated for shipboard use WB Finish Latex-based, indoor/outdoor, UV-resistant coating for Armaflex insulation * OUTDOOR USE: ArmaTuff & ArmaTuff SA Insulation with durable, white metal, factory-applied cladding made for exterior applications Painting with WB Finish or other protective jacketing is required to prevent damage to the insulation in exterior applications and to comply with the insulation protection sections of the International Energy Conservation Code (IECC) and ASHRAE 90.1. www.armacell.us 2

Duct Liner and Wrap Ducts should be lined or wrapped with fiber-free elastomeric foam insulation to improve thermal efficiency, control condensation, absorb noise and protect indoor air quality. Accessories AP Armaflex & AP Armaflex FS The original fiber-free insulation for thermal and acoustical duct liner or wrap applications Armafix Pipe Hanger Single piece insulated pipe hanger with self-adhesive closure AP Armaflex SA & AP Armaflex FS SA Fiber-free insulation for thermal and acoustical duct liner or wrap applications in self-adhering format Armaflex Pre-fabricated Fittings Made to order fittings for T s, Elbows, P Traps and more AP Coilflex Duct Liner Conformable, fiber-free insulation for thermal and acoustical duct liner for automatic coil lines AP Armaflex Insulation Tape Pressure sensitive foam tape for insulating pipes and fittings AP Spiralflex Lightweight foam on a flexible backer especially engineered for use as a spiral duct liner Armaflex Black LapSeal Tape Low profile tape for AP Armaflex Black LapSeal end seams 3 www.armacell.us

Iron / Copper Pipe Size Chart Choose sheet and roll insulation for pipes larger than 8", mechanical systems, chillers, larger surfaces, tanks and fittings. Available in regular and self-adhering for both interior and exterior applications. Nominal Insulation ID Fits Pipe Size Actual Insulation ID 1,2 Copper ID Iron / PVC IPS DN Min ID (in) Max ID (in) Min ID (mm) Max ID (mm) 3/8" 1/4" 1/8" 6 0.420 0.500 10.7 12.7 1/2" 3/8" 1/4" 8 0.560 0.640 14.2 16.3 5/8" 1/2" 3/8" 10 0.710 0.790 18.0 20.1 3/4" 5/8" - - 0.810 0.910 20.6 23.1 7/8" 3/4" 1/2" 15 0.940 1.050 23.9 26.7 1-1/8" 1" 3/4" 20 1.200 1.310 30.5 33.3 1-3/8" 1-1/4" 1" 25 1.450 1.570 36.8 39.9 1-5/8" 1-1/2" 1-1/4" 32 1.710 1.830 43.4 46.5 1-1/2" - 1-1/2" 40 1.970 2.090 50.0 53.1 2-1/8" 2" - - 2.220 2.340 56.4 59.4 2" - 2" 50 2.580 2.780 65.5 70.6 2-5/8" 2-1/2" - - 2.720 2.880 69.1 73.2 2-1/2" - 2-1/2" 65 3.080 3.280 78.2 83.3 3-1/8" 3" - - 3.230 3.390 82.0 86.1 3" - 3" 80 3.700 3.900 94.0 99.1 3-5/8" 3-1/2" - - 3.740 3.880 95.0 98.6 4-1/8" 4" 3-1/2" 90 4.250 4.420 108.0 112.3 4" - 4" 100 4.750 4.950 120.7 125.7 5" - 5" 125 5.810 6.010 147.6 152.7 6" - 6" 150 6.880 7.080 174.8 179.8 8" - 8" 200 8.880 9.080 225.6 230.6 1. ID tolerances are typical values and may differ depending on the product and wall thickness. 2. Insulation ID is sized larger than the pipe OD to fit over copper pipe couplings. When properly installed, a gap between the insulation and pipe will not adversely effect the insulation performance. NOTE: See installation guide for proper installation instructions. WEB: www.armacell.us > Knowledge Center > Document Downloads > Mechanical Insulation > Installation Manuals www.armacell.us 4

Product Applications Common Applications REFRIGERATION, HOT & COLD LINES, CHILLED WATER HVAC INTERIOR DUCT SYSTEMS EXTERIOR DUCT SYSTEMS Product Requirements Microban antimicrobial protection Condensation control 25/50 rating Tough, durable AP Products: Microban antimicrobial protection Condensation control Moisture resistant 25/50 rating Noise blocking Condensation control Microban antimicrobial protection Condensation control Outdoors Maintenance-free UV-resistant Recommended Product W White LapSeal Black LapSeal Armaflex Coil (no added antimicrobial) AC Accoflex Black LapSeal AP Spiralflex Armaflex Coil (no added antimicrobial) and FS Duct Liner/Wrap SA Self-Adhering and FSSA Duct Liner/Wrap AP Coilflex AP Spiralflex ArmaTuff and ArmaTuff SA (with WB Finish) Armacell Product Specifications Specifications Test Method Thermal Conductivity, Btu in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) ASTM C 177 or C 518 AP Armaflex Tubes, AP Armaflex White LapSeal, AP Armaflex Black LapSeal 0.245 (0.0353) 0.254 (0.0366) Water Vapor Permeability, Perm-inch. [Kg/(s m Pa)] ASTM E 96, Procedure A 0.05 [0.725 x 10-13 ] AP Armaflex Sheet, Rolls, Duct Liner/Wrap, AP Coilflex, AP Spiralflex 0.245 (0.0353) 0.254 (0.0366) AC Accoflex Tubes 0.27 (0.039) 0.226 (0.040) 0.05 [0.725 x 10-13 ] (AP Armaflex) 0.08 [1.16 x 10-13 ] Flame Spread and Smoke Developed Index ASTM E 84 UL94 25/50 V-0, 5VA 25/50 25/50 Microban Antimicrobial Protection Yes Yes No Water Absorption, % by Volume ASTM C 209 0.2 0.2 0.2 Upper Use Limit 220 F (105 C) 180 F (82 C) 220 F (105 C) Lower Use Limit j -297 F (-183 C) -297 F (-183 C) -297 F (-183 C) Ozone Resistance ASTM C 1534 Good Good Good Ultraviolet (UV) Resistance QUV Chamber Test Good Third Party Certification Factory Mutual Approvals Yes Yes GREENGUARD Gold Yes Yes Specification Compliance ASTM C534 ASTM C534 ASTM C534 j At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. For applications of -40 F to -297 F (-40 C to -183 C) contact Armacell. 5 www.armacell.us

MECHANICAL SYSTEMS, CHILLERS SOLAR OR HIGH TEMPERATURE (300 F) RESIDENTIAL PLUMBING MARINE & OFFSHORE Thermally efficient 25/50 rating Sheet & roll forms Easy to cut and fabricate Microban antimicrobial protection Thermally efficient High temperature range for solar collectors or hot water piping Mold resistant Economical 25/50 rating Noise blocking Non-halogen Sheet and Rolls Black LapSeal UT Solaflex Tubolit NH Armaflex NH Armaflex UT Solaflex ArmaTuff Tubolit 0.27 (0.039) 0.276 (0.040) 0.28 (0.046) 0.286 (0.041) 0.05 [0.725 x 10-13 ] 0.08 [1.16 x 10-13 ] Meets EB 4013, SOLAS,USN test. Toxicity-free V-O 0.25 (0.036) 0.256 (0.037) 0.25 (0.036) 0.05 [7.25 x 10-13 ] 0.00 Laminate 25/50 V-0 (for exterior application) No No Yes No 0.2 0.2 0.00 [0.0 x 10-13 ] 25/50 HBF 0.2 0.0 Laminate 0.2 250 F (120 C) 300 F (150 C) 180 F (82 C) 200 F (93 C) -297 F (-183 C) -297 F (-183 C) -297 F (-183 C) -200 F (-129 C) Good Excellent Excellent Good Excellent Excellent Yes Yes Yes Yes Yes ASTM C534 ASTM C534 ASTM C534 ASTM C1427 www.armacell.us 6

The Armacell Advantage Building Relationships That Endure Armacell is an easy access organization that values customers as business partners. Support is available for help with installation, technical questions and specification assistance. Customer Service: The Armacell Customer Service Team is the best in our industry. Teams from manufacturing, logistics and customer service work to anticipate surges in demand, monitor service levels and promptly resolve any customer issues. Application and Technical Assistance: Guidance and training for installers, from the experts who trained an industry. Specification Assistance: Specifiers can receive guidance for writing mechanical specifications and selecting the right solution for their project. Call 800.866.5638 8:00 a.m. 4:30 p.m. EST for assistance. info.us@armacell.com World Leader in Mechanical Insulation Armacell is the global leader in mechanical insulation and foam technologies. Armacell produces Armaflex, the world s first elastomeric thermal insulation and provides product solutions to meet the challenges of thermal efficiency, condensation control, indoor air quality, sound attenuation and long-lasting performance. Armacell has unrivaled global capabilities bolstered by 23 manufacturing facilities around the world including five operations in the US and one in Canada. Globally integrated research and development allows our scientists and technicians to benchmark global practices and adapt them to either global or regional requirements, codes or specifications. Brampton, Ontario, Canada South Holland, IL Spencer, WV Conover, NC Dallas, GA Mebane, NC ARMACELL LLC 7600 Oakwood Street Extension Mebane, NC 27302 TEL.: 800.866.5638 FAX: 919.304.3847 info.us@armacell.com www.armacell.us * Microban antimicrobial product protection is limited to the product itself and is not designed to protect the users of these products from disease causing microorganisms, or as a substitute for normal cleaning and hygiene practices. Microban International, Ltd. makes neither direct nor implied health claims for the products containing Microban antimicrobial product protection. Data, photomicrographs and information presented are based on standard laboratory tests and are provided for comparative purposes to substantiate antimicrobial activity for non-public health uses. Product Selection Guide 999 Eng/USA 5/2016 2016 Armacell LLC Printed in United States of America