THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR PERMEABILITY OF HIGH PERFORMANCE CONCRETE

Similar documents
NON DESTRUCTIVE TESTING OF THE CONCRETE COVER EVALUATION OF PERMEABILITY TEST DATA

LONG-TERM BEHAVIOUR COMPOSITE GIRDERS AND BEHAVIOUR UNDER SERVICE LOAD OF

Lecture Notes. Elasticity, Shrinkage and Creep. Concrete Technology

International Symposium Non-Destructive Testing in Civil Engineering (NDT-CE) September 15-17, 2015, Berlin, Germany

Utilization of concrete as a construction material in the concept of Radioactive Waste Storage in Slovak Republic

ASSESSMENT AND INTERPRETATION OF IN-SITU STRENGTH OF CONCRETE In-situ strength of concrete

CHAPTER 6 POLYPROPYLENE FIBRE REINFORCED GEOPOLYMER CONCRETE COMPOSITES

INSTITUTE OF CONCRETE TECHNOLOGY CONCRETE TECHNOLOGY & CONSTRUCTION Stage 2: GENERAL PRINCIPLES Learning objectives

Questions with Solution

THRESHOLD VALUES OF AIR PERMEABILITY OF CONCRETE COVER - A CASE STUDY IN JAPAN

Performance of High Strength High Performance Steel Fiber Reinforced Concrete for use in Seismic Resistant Structures

Total 30. Chapter 7 HARDENED CONCRETE

Effect of fiber fatigue rupture on bridging stress degradation in fiber reinforced cementitious composites

Research on Weight Reduction of PC Composite Members Using Ultra High Strength Fiber Reinforced Cementitious Composites (UFC)

A STUDY ON THE ENHANCEMENT OF DURABILITY PERFORMANCE OF FACED SLAB CONCRETE IN CFRD

Effect of Curing Conditions on the Freeze-Thaw Durability of Self-Consolidating Concrete Including Fly Ash

PENETRATION RESISTANCE OF HYBRID FIBRE REINFORCED CONCRETE UNDER LOW VELOCITY IMPACT LOADING

Cambers of prestressed precast bridge girders, prediction vs. reality

COUPLED FEM MODEL FOR CONCRETE EXPOSED TO FIRE LOADING

Application of ultrasonic testing to steel-concrete composite structures

Evaluation and Observation of Autogenous Healing Ability of Bond Crack along Rebar

IN-SITU TESTING OF THE PEREMEABILITY OF CONCRETE

Efficiency of using Polymer Impregnated Porous Concrete in Structural Engineering Applications

Investigation of Natural Hybrid Fibre Reinforced Beams with Nano Concrete under Cyclic Loading

Theoretical and experimental analysis of load-carrying capacity of steel-concrete composite beams with glass-fibre-concrete slab

Study On Properties Of High Strength Silica Fume Concrete Withpolypropylene Fibre

Study on chloride binding of self-compacting concrete with different crack lengths: non-steady state migration test

Shear Strength of Self Compacting Concrete

DURABLE PAVEMENT WITH ECC

Creep of Concrete in Contemporary Code-Type Models

Summary report: Highly insulating, monolithic concrete panels made of architectural lightweight concrete

USE OF PERVIOUS CONCRETE FOR STORM WATER MANAGEMENT

AIR PERMEABILITY ASSESSMENT IN A REINFORCED CONCRETE VIADUCT

METHOD FOR OBTAINING AND TESTING DRILLED CORES FROM PCCP AND PRECAST GIRDERS (Kansas Test Method KT-49)

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

STRENGTH AND RHEOLOGICAL PROPERTIES OF FIBER REINFORCED SELF COMPACTING CONCRETE WITH ALCCOFINE

Non Destructive Test on Fiber Reinforced Self Compacting concrete

EXPERMENTAL STUDY OF MODULUS OF ELASTICITY DUE TO CHANGE IN STEEL FIBER REINFORCED CONCRETE AND SIZE OF AGGREGATES

EXPERIMENTAL INVESTIGATION OF HOLLOW CORE SLAB USING DIFFERENT FIBRE

Study on Estimated In-situ Cube Strength from Cores and Cube Strength

Fundamentals of Concrete

PULLOUT CAPACITY BEHAVIOUR OF FRP-HEADED REBARS

Advance Concrete-Aggregate replaced by Coconut Shell

Title. Author(s)SARBINI, N. N.; IBRAHIM, I. S.; SAIM, A. A. Issue Date Doc URL. Type. Note. File Information

Topic 1 - Properties of Concrete. 1. Quick Revision

THE STUDY ON PRuDuLIluN AN L) S1KtNU1H OF ARCH PAN AS PERMANENT FORMWORK FOR FLOOR SLABS ZAID FIKRI BIN ZAINAL RASHID

Non/Minor Destructive Methods for Investigating Concrete Durability of National Museum of Western Art, Japan

Self Consolidating Concrete

Frost Resistance and Permeability of Cement Stabilized Gravel used as Filling Material for Pearl-Chain Bridges

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 3, 2010

EFFECT ON MECHANICAL PROPERTIES OF CONCRETE USING NYLON FIBERS

Early age behaviour of fibre reinforced shotcrete

CN7001-ADVANCED CONCRETE TECHNOLOGY QUESTION BANK

SUPER ABSORBENT POLYMERS TO STIMULATE SELF HEALING IN ECC

INFLUENCE OF PRE-WETTED LIGHTWEIGHT AGGREGATE ON SCALING RESISTANCE OF HIGH PERFORMANCE CONCRETES

ATENA Program Documentation Part 4-8

3D fatigue analysis of RC bridge slabs and slab repairs by fiber cementitious materials

EVALUATION ON SHEAR CAPACITY OF RC BEAMS USING U-SHAPED UFC PERMANENT FORMWORK

Experimental Study on Mechanical Properties of Basalt Fibre Reinforced Concrete

DURABILITY PERFORMANCE OF EPOXY INJECTED REINFORCED CONCRETE BEAMS WITH AND WITHOUT FRP FABRICS

Resistance of cracked concrete to chloride attack

NUMERICAL MODEL FOR PREDICTION OF CRACKS IN CONCRETE STRUCTURES

Application and properties of Fiber Reinforced Concrete

Serviceability limit state of two-way reinforced concrete slab strengthened with different techniques

HIGH STRENGTH SELF-COMPACTING CONCRETE AT ELEVATED TEMPERATURE

AN EXPERIMENTAL STUDY ON GLASS FIBRE REINFORCED CONCRETE

STRENGTH CONSEQUENCE MINIMIZATION OF DIGGING OFF BURIED GAS PIPELINE AT ISOLATION COAT RENOVATION REALIZED DURING OPERATION

In-Place Strength by Pullout

Experimental Research of Bridges with Encased Beams

The Creep of Cement Paste with Various Content of the Fly Ash in the Age 1 Year

Performance of Glass Fibre Reinforced Self Compacting Concrete

Research Article The Effect of Accelerators and Mix Constituents on the High Early Strength Concrete Properties

2.6 TESTING WET AND HARDENED CONCRETE

Experimental Determination of Concrete Compressive Strength by Non-Destructive Ultrasonic Pulse Velocity Method

EVALUATION OF TIME-DEPENDENT BEHAVIOUR OF COMPOSITE CONCRETE SLABS WITH STEEL DECKING (AN EXPERIMENTAL STUDY)

APPLICATION OF SELF-CONSOLIDATING CONCRETE FOR BRIDGE REPAIR

Durability of Glass, Polypropylene and Steel Fiber Reinforced Concrete

Application of Formtex Controlled Permeability Formwork in the Arabian Gulf

TI-B 102 (15) Test Method Strains from Creep and Early-Age shrinkage

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Keywords: super absorbent polymers, self-healing, green construction technology

Loading Tests of Thin-Walled Ferro-Cement Panels for Horizontal Slab Structures

Effect of Steel Fibers on Plastic Shrinkage Cracking of Normal and High Strength Concretes

BUILDING STRUCTURES WITH GRC. FERNANDO A. BRANCO, JOÃO FERREIRA, JORGE DE BRITO and JOSÉ R. SANTOS

100kN Beam; 200kN Beam/Curb; 1600kN Hand operated; 1800kN Econo; 2000kN; 3000kN; 5000kN PREC3FT COMPRESSION AND FLEXURAL TESTING MACHINES

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Tensile Bond Between Substrate Concrete and Normal Repairing Mortar under Freeze Thaw Cycles

FLEXURAL BEHAVIOUR OF FERROCEMENT WITH PVA FIBRE REINFORCED HIGH-STRENGTH MORTAR

Monitoring of Long-Term Effects on Concrete Bridge Realised by Balanced Cantilever Method

Extending the Lifespan of Structural Concrete

Experimental Study on Slurry Infiltrated Fibre Reinforced Concrete with Partial Replacement of Fly Ash

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

Softening Coefficients for Prestressed Steel Fiber Reinforced Concrete. Prestressed Steel Fiber Reinforced Concrete in Tension.

ULTRA-HIGH STRENGTH SHEAR KEY GROUT

Center for By-Products Utilization

Behaviour of GFRP tube reinforced concrete columns under eccentric loading

Structural Behavior of Self-Compacting Concrete Elements

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

APPLICATION POSSIBILITIES OF FIBER COMPOSITES WITH POLYMER-MATRIX IN BUILDING INDUSTRY

for Precast Elements November 3, 2010

Transcription:

2009/2 PAGES 1 7 RECEIVED 10. 1. 2009 ACCEPTED 9. 4. 2009 P. PAULÍK, I. HUDOBA THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR PERMEABILITY OF HIGH PERFORMANCE CONCRETE ABSTRACT Peter Paulík PhD Student at the Department of Concrete Structures and Bridges Research field: High performance concrete, fibre concrete, experimental investigation of surface layer properties of concrete elements Igor Hudoba Associate professor at the Department of Concrete Structures and Bridges Research field: High performance concrete and fibre concrete, mechanical and physical properties of high performance fibre concrete, durability and life-span of concrete structures Slovak University of Technology Faculty of Civil Engineering Radlinského 11, 813 68 Bratislava Slovak Republic KEY WORDS The permeation of gases through hardened concrete is a physical property which is important to know, especially in terms of the defining properties of its surface layer. The gas permeability of the surface layer can fundamentally affect the serviceability limit state and the overall service life of certain types of concrete structures or elements such as containers for the storage of environmentally hazardous waste, concrete tunnel linings, concrete pavements, etc. To obtain reliable parameters characterizing the gas permeability of hardened concrete requires reliable test equipment and testing methods. At present, the most commonly used test equipment is a TORRENT PERMEABILITY TESTER (hereinafter referred as TPT), which was developed several years ago by the Swiss firm PROCEQ. This paper presents some air permeability test results carried out on high performance fibre-reinforced concrete specimens. The level of air permeability and some other physical properties of concrete were measured on concrete cube specimens with and without compressive stresses applied at a certain level during the test. High performance concrete fibre reinforced concrete air permeability of hardened concrete specimens dynamic modulus of elasticity permeability of stressed concrete 1. INTRODUCTION The gas permeability of concrete is a property which is recognized as a basic indicator of its durability. The measuring of air permeability used to mostly be carried out on samples, which were not exposed (before or during the tests) to certain external loads, which could cause microcracks in a hardened cement matrix. In the case of real structures there is always some stress level, and in this case the permeability of concrete is always affected by microcracks. To know both the permeability of plain concrete and the permeability of concrete containing a certain amount of microcracks is the basic assumption for a correct evaluation of its durability. There are different methods for measuring the parameters which characterize the permeability of concrete in relation to gas permeability [2], [3]. The distinctions are in the testing procedures as well as in the nature of the permeability parameters observed. In order to obtain a realistic view of the durability of a concrete structure, it is important to know the physical properties of its surface layers up to a depth of approx. 50 mm. The durability and the service life span of the structure depend on these properties. The execution procedures of concrete structures are accompanied by commonly known phenomena such as the bleeding of fresh concrete, the accumulation of cement milk in contact with the formwork (the wall effect), the method of the compaction of fresh concrete, the surface modifications of freshly poured concrete or possible aggregate segregation. As a consequence of these factors, the characteristics of fresh and hardened concrete are different near the formwork and in the mass of the concrete elements. This 2009 SLOVAK UNIVERSITY OF TECHNOLOGY 1

is the main reason why it is necessary to assess the surface layers of hardened concrete structures by using non-destructive test equipment which guarantees fast and reliable test results. Such requirements can fulfil the TPT test method. This set-up ensures the direct flow of air into the inner chamber and the calculation of the correct values of the permeability coefficient kt. The calculations are based on a theoretical model expressed by the formula: 2. TPT MEASUREMENT DEVICE AND TESTING METHOD The TPT measuring device consists of a vacuum pump, a twochamber vacuum cell with sealing rings, a control unit and an automatic evaluation unit (Fig. 1). The principle of the device is based on measuring the time-dependent increasing of pressure in the inner chamber after a vacuum is generated by the pump. The outer chamber serves for the purpose of draining fake air flowing from the circumference of the head. By this means the direction of the air flowing into the inner chamber in a perpendicular direction to the vacuum cell plane is achieved (Fig.2). The advantage of TPT equipment is its portability, which easily allows measuring the permeability parameter of concrete surface layers directly at construction sites. Fig. 1 Set of the TORRENT PERMEABILITY TESTER device Fig. 2 The function of the two-chamber vacuum cell Where: kt the coefficient of the permeability of the concrete [m 2 ] V c the volume of the internal chamber [2,2.10-6 m 3 ] A area of the inner chamber [19,6.10-4 m 2 ] μ viscosity of the air at 20 C [1,84.10-5 Ns/m 2 ] Ε theoretical porosity of the concrete [0.15] Pa atmospheric pressure [1000 Pa] ΔP change of the pressure in the inner chamber [measured value... 20 N/m 2 ] t 0 the beginning of the measurement [60s] t the total time of the measurement [max. 720s] To obtain the values which characterize the permeability of a concrete surface layer by the TPT device, a measuring procedure is required, which consists of the following steps: The surface of the concrete should be cleaned of dust at the place of measurement The control unit of the touchscreen is switched on, and the two chamber vacuum cell is attached to the place of measurement. By opening the valve, the air is sucked off the outside chamber so that an under-pressure of 1 bar is created, and the cell leaches to the concrete surface with its sealing ring. The procedure is followed by opening the valve on the inlet hosepipe which is connected to the inner chamber; consequently a vacuum is created in this chamber by the pump. The measurement is terminated automatically, indicating the value of the coefficient of permeability kt [m 2 ] and the depth of vacuum penetration L [mm] on the screen. The parameters are recorded immediately when an effective increase in the underpressure reaches the calibrated pressure difference, which is more than 20 mbar, respectively after 720 seconds. The kt and L parameter measurements, in situ, are obtained in less than 15 minutes. The measured permeability values, kt and the depth of vacuum penetration L, depend on the moisture of the surface layer of the concrete. By increasing the moisture of the concrete the measured value of the permeability factor kt decreases. As part of the TPT measuring device there is also a sensor for measuring the moisture (1) 2 THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR...

location in order to enable the leeching effect of the vacuum head - The surface of the concrete should not be cracked - The distance between the outer edge of the structural element and the external diameter of the cell must be a min. of 20 mm - The inner chamber of the cell should not be located above the reinforcement bar The manufacturer of the TPT equipment recommends regular calibrations, especially in cases of higher pressures and temperatures While measuring electrical resistance on wet concrete, it is optimally recommended to provide 6, but at least 3, measurements. To determine the kt value it is essential to use the average value of the measured electrical resistance ρ and the measured kt value deducted from the graph, which was developed by the TPT equipment manufacturer The thickness of the concrete element in the location of the measurement must be greater than the depth of vacuum penetration L. Fig. 3: Scheme of TPT device content of the concrete s surface layer by using electrical resistance ρ. The permeability coefficient kt, for wet or young concrete, is determined by the correction of the kt. For this purpose a nomogram for determination of the electrical resistance ρ value can be used. The nomogram was developed by the TPT equipment manufacturer [5]. The overall evaluation of the permeability measurements of the surface layers of the concrete by using the permeability factor kt and the depth of vacuum penetration L is accomplished by classification of the surface layer into a quality class according to Tab. 1. During practical permeability parameters measurements performed on the construction, the manufacturer of the TPT measuring equipment requires compliance with the following principles: The measurement point: - not to carry out measurements on wet concrete. - The concrete surface must be sufficiently flat at the measurement Tab. 1 Quality classes of the concrete s surface layer Quality of the surface layer of the concrete Index kt.10-16 (m 2 ) very bad 5 >10 bad 4 1.0 až 10 normal 3 0.1 až 1,0 good 2 0.01 až 0,1 very good 1 <0.01 3. AIR PERMEABILITY OF PLAIN CONCRETE SPECIMENS EXPOSED TO COMPRESSIVE STRESS The TPT equipment is most commonly used for testing the air permeability of surface layers on reinforced or prestressed concrete structures. During the service life of these structures there is a certain state of stress in its surface layers at different places, which is dependent on the position and magnitude of the loads at that moment. There is relatively little experience with the measurements of gas permeability through high-strength fibre-reinforced concrete. For example, PICADENT, V., et al. [2] measured gas permeability on normal, high performance and fibre-reinforced concrete samples, which were cut from cylinders (110 mm and 220 mm in diameter) and then exposed to cyclical pressures with a magnitude reaching 60% and 90% of the ultimate compressive strength. The impact of the stress level on gas permeability was monitored on unloaded samples perpendicular to the cross section. ADÁMEK, J., et al. [1] monitored the changes of the permeability coefficient kt over time (by the TPT method) on normal strength concrete, using several types of drainage foils attached to the shuttering. The tests presented were focused on monitoring the air permeability (by using the TPT method) on high-performance concrete specimens, with and without different amounts of fiber reinforcement exposed to different stress levels. Measurements were provided on concrete THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR... 3

cubes in a direction perpendicular to the direction of the casting and inducing pressure forces (Fig. 4b). Cubes with an edge of 200 mm were used for the tests in accordance with the requirements for the TPT method [5]. All the cubes were made of high-performance Tab. 2 Compressive strength of concrete (mean values) Type of concrete Amount of fibre reinforcement [%] age: 28 days Compressive strength f cm,cube200 [MPa] age: 180 days age: 10 years A 1.37 60.63 68.71 69.40 B 0 50.98 56.78 76.80 C 2.74 51.85 63.75 74.90 Fig. 4 Air permeability measurements on concrete cube specimens a) Air permeability test on unloaded cube specimens, b) Air permeability test on cube specimens exposed to a compressive load Tab. 3 Dynamic modulus of elasticity (mean values) Type of concrete Amount of fibre reinforcement [%] Dynamic modulus of elasticity E c,dyn. [GPa ] age: 28 days age: 10 years A 1.37 41.49 47.11 B 0 41.78 45.70 C 2.74 43.63 48.90 concrete (type B) and high-performance fibre-reinforced concretes (types A and C). The specimens were stored over a time span of 10 years in free air in a laboratory environment. FIBRAFLEX metal fibres (French origin) were used as fibre reinforcements. The basic parameters of the compressive strength and dynamic modulus of elasticity of the concrete cubes tested are in Tabs. 2 and 3. The amount of fibre reinforcement means its weight fraction in the whole mix. The mean values of the air permeability coefficient kt and the depth of vacuum penetration L on the concrete samples measured on different types of concrete A, B and C under different compressive stress levels are presented in Tab. 4. Particular measurements were carried out at compressive stress levels equal to 0%, 30% and 60% of the mean compressive strength of the concrete at the actual time, expressed by the f ci / f cm ratio. Permeability was also measured after unloading on each sample (from the 30% and 60% of f cm stress level), but these values are not presented in this paper. After the measurement of air permeability kt and the depth of vacuum penetration L were done, measuring the dynamic modulus of elasticity E c,dyn was carried out using an ultrasound device. The values of the dynamic modulus of elasticity given are in Table 5 for each type of concrete (A, B and C) at different compression stress levels. On each sample 3 measurements were carried out along its diagonal, and then the average value was computed. The effect of the amount of fibre reinforcement on the change in permeability coefficient kt depending on the external compressive stress level is expressed by the values presented in Tabs. 6, 7 and 8. The measured changes in the permeability values are possible to express by the relative values presented in Tabs. 9 and 10. A graphic presentation of the air permeability coefficient kt increasing (vs. decreasing) depending on the amount of fibre-reinforcement and compressive stress level is shown in Figs. 5, 6 and 7. Tab.11 presents the values of the dynamic modulus of elasticity E c,dyn at 30% and 60% of f cm. A graphic presentation of the relation Tab. 4 Values of air permeability coefficient kt and the depth of vacuum penetration L (mean values) these values are not included in the mean value because of the occurrence of a crack, which significantly affected the test result. 4 THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR...

Tab. 5 Dynamic modulus of elasticity E c,dyn. (mean values) Tab. 9 Relative increase of permeability Tab. 6 The effect of the amount of fibre reinforcement on permeability coefficient kt at different levels of compressive stress (from level of 30% to 60% of f cm ) Tab. 10 Relative increase of permeability after at 30 and 60% of f cm unloading from 30 and 60% of f cm Tab. 7 The effect of the amount of fibre reinforcement on the permeability coefficient kt after unloading from 60% of f cm stress level (in comparison to the permeability measured after unloading from 30% of f cm stress level) Rel. permeability increase Fig. 5 Relation between an increase in relative permeability (compressive stress level increasing from 30% to 60% of f cm ) and the amount of fibre reinforcement. Tab. 8 Permeability coefficient kt at 60% of f cm stress level and after unloading in comparison with the amount of fibre reinforcement Fig. 6 Relative increase in permeability at 30% and 60% of f cm stress level THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR... 5

Tab. 11 Effect of the amount of fibre reinforcement on the dynamic modulus of elasticity E c,dyn at 30 and 60% of f cm stress level Fig. 7 Relative increase in permeability after unloading from 30% and 60% of f cm stress level Fig. 8 Relation between the dynamic modulus of elasticity and the amount of fibre-reinforcement (values are at a compressive stress level equal to 30% of f cm ). between the dynamic modulus of elasticity and the amount of fibrereinforcement is shown in Fig. 8 (the values are at a stress level equal to 30% of f cm ). 4. CONCLUSIONS In relation to the increasing amount of fibres in concrete, there is a significant reduction of its permeability under a compressive load. As more fibres are used in concrete, the permeability affected by the increased load is lower. Concrete without fibers presents a more than 23-times greater degree of permeability after the stress level was increased from 30 to 60% of f cm. The same concrete with a fiber amount of 2.74% showed only a 4-times greater degree of permeability after increasing the same load. The quality of the compaction of a concrete mix has a much greater impact on permeability than the amount of fibre reinforcement. While increasing the compressive load level, a crack occurred in some specimens. This fact strongly influenced the test results. If a visible crack developed (at a stress level of 30% or 60% of f cm ), this result was not used for calculating the test results. After discharging the compressive load, the crack was closed and was not visible to the eye. From the measurement results, we concluded that the permeability measured at a surface disturbed with a visible crack cannot be used in evaluating the results. After discharging the compressive load, the regeneration of the permeability was more effective on concrete specimens without fiber reinforcement, where the permeability decreased more than 8 times. On the other hand, concrete with a fibre content of 2.74% regenerated only 2.4 times. In concrete specimens without fiber reinforcement, a reduction in relative permeability (0.66 times) was observed at the 30% of f cm stress level. In the case of fibre reinforced concrete this phenomenon does not occur and the permeability of the concrete specimens at stress level of 30% of f cm was approximately the same as the permeability of the unloaded concrete specimens. The impact of the amount of fiber reinforcement was also observed on the permeability of the concrete specimens after unloading. The specimens without fibers, which were loaded to a stress level of 60% of f cm and consequently unloaded, showed a 4.3 times increase in permeability in comparison with the state after unloading from a stress level of 30% of f cm. On the other hand, the same concrete containing 2.74 % fibers, showed in the same case only a 2.4 times increase in permeability. The dynamic modulus of elasticity is influenced by the compressive stress level as well as by the amount of fiber reinforcement. When the stress level was increased to 60% of f cm, the dynamic modulus of elasticity was also increased (1.1 times in the specimens with 2.74% of fiber reinforcement and 1.06 times in the specimens without fiber reinforcement). The dynamic modulus of elasticity at the stress level of 30% of f cm was higher in specimens with fibre reinforcement (the higher amount of fiber reinforcement induced higher values 6 THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR...

of the dynamic modulus of elasticity). After unloading from a certain compressive stress level, the dynamic modulus of elasticity remained at the same level as before the unloading. On a stress level of 60% of f cm, the measured values of the dynamic modulus of elasticity were higher at the middle part of the specimen (cube) than at the edges (the difference between the measured values was approx. 15%). This paper was realized with the support of the VEGA research project No. 01/0180/08 - Factors influencing the properties of the surface layers of concrete structural elements from the points of view of execution and environmental action. REFERENCES [1] Adámek, J., Juránková, V., Stehlík (2006), M.: Influence of the arrangement of a drainage cover on the properties of a concrete surface layer, In: Proceedings of the CONCRETE DAYS 2006 Conference, Bratislava, pp.173-178 (in czech) [2] Picadent, V., Khelidj, A., Bastian (2001), G.: Gas permeability of mechanically damaged concrete, In: Proceedings of Third International Conference on Concrete Under Severe Conditions, Edited by N.Banthia, K.Sakai and O.E.Gjorv, Vancouver, Canada 2001 [3] Bágeľ, Ľ., Živica, V. (1998): Relationship between Pore Structures and Permeability of Hardened Cement Mortars: On the Choice of Effective Pore Structure Parameters, Cement and Cement Research, No.27, 1997/98, pp.1225-1235 [4] Hudoba, I., Mušková, L. (1999): Final report on control test results of mechanical and physical properties of fibre concrete for container production, Faculty of Civil Engineering STU, April 1999 (in Slovak) [5] PROCEQ (2008): Torrent Permeability Tester - Operating Instructions, www.proceq.com [6] Banthia N., Bhargava A. (2007): Permeability of Stressed Concrete and Role of Fiber Reinforcement, ACI Materials Journal, V. 104, 2007 THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR... 7