Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process

Similar documents
Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Energy Production Systems Engineering

SCR for NO x Control in Coal-fired Power Plants

Process Analytics Using Quantum Cascade Laser

Monitoring cement plant stack emissions using FTIR

New Requirements for the Measurement of Ammonia Emissions

Controlling Ammonia-in-Ash through Direct Measurement of Ammonium Bisulfate

Sensors and Environmental Compliance

WHITEPAPER: AMMONIA MEASUREMENT FOR COMBUSTION SOURCES

FIRST APPLICATION OF BABCOCK-HITACHI K.K. LOW SO 2 TO SO 3 OXIDATION CATALYST AT THE IPL PETERSBURG GENERATION STATION

NOx in Cement Clinker Production - Experiences Reducing NOx-Emissions

Power-Cost Alternative De-NOx Solutions for Coal-Fired Power Plants

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

Reinhold Environmental Ltd.

Simultaneous process and emission monitoring through two automatically

SCR Control Strategy and CEMS for an Ultra-Low NO x Emitter

ACF5000 The new benchmark in FTIR CEMS Key features pocket guide

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

SCR-Catalyst Management. Dr. Dirk Porbatzki UTG / Catalyst & Oil Management

Gas Cleaning by SCR and ESP

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

NOx CONTROL FOR HIGH ASH COAL-FIRED PLANT 12 TH E C C R I A, 5-7 S E P T E M B E R , C A R D I F F, UK

ABB Measurement & Analytics Flowmeter technologies

Post-Combustion NOx Control - Program 73

Advanced Instrumentation for Improved Plant Operation

Ammonia Injection and Mixing Systems 101

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Optimal Design and Operation of SNCR System for a 150t/h CFB Boiler and Discussion on the Measurement of Flue Gas Components

Cross-effects and total gas clean-up system lay-out

CANADA UNISEARCH founded in 1980

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

LICONOX Linde s new technology for removal of NOx and SOx integrated in the CO 2 processing unit

A COMPARISON OF GAS ANALYSIS TECHNOLOGIES AVAILABLE FOR EFFICIENT AND SAFE COMBUSTION IN CONTROL FIRED HEATERS

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

Catalytic Activated Ceramic Dust Filter a new technology for combined removal of dust, NOx, dioxin, VOCs and acids from off gases.

ABB Measurement Products Monitoring emissions from incineration plants

Information Centre Nitric Acid Plants. Kittiwake Procal Ltd Page 1 of 6

Optimisation of ammonia injection for an efficient nitric oxide reduction

Andover Technology Partners

Co-Combustion of Wood and Straw in a Circulating Fluidized Bed Boiler reduction of NO x emission

State of the Art (SOTA) Manual for Stationary Gas Turbines

NOx in Cement Clinker Production - Formation and Measures to minimize NOx-Emission

Up gradation of Boilers to Implement New Pollution Norms

De-NOx Concept to commissioning

nat Presentation Title ( Arial, Font size 28 ) Control of Sulphur Dioxide, Oxides of Nitrogen and Mercury Date, Venue, etc..( Arial, Font size 18 )

ABB measurement products Monitoring emissions from incineration plants

Fully Extractive Vs. Dilution Extractive CEMS

NOx Compliance Using the NOxOUT SNCR Process in the 1200 TPD Montgomery County. Resource Recovery Facility

Improving Steel Reheat Furnace Performance with the ZoloSCAN-RHT Combustion Monitoring System

Improving H 2 O Measurement in Catalytic Reformer Hydrogen Recycle Streams

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

GAA330-M Emission monitoring system for marine applications

STEAG Energy Services LLC. Engineering and Consulting Services with a focus on the environment.

Biomass Combustion Technology

Managing the Catalysts of a Combustion Turbine Fleet

Low-Temperature SCR. Intelligent and Cost-Effective Regeneration without Excess Emissions. 1. Pollutant capture principle...408

Online Infrared Flue Gas Analyzer Gasboard 3000

FCCU NO x Reduction - SCR Retrofit. October Vice President of Engineering KTI Corporation

6515 Series Measurement of CO2 in Flue Gases. A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

GUIDANCE FOR SAMPLING OF NO X CONCENTRATIONS FOR SCR SYSTEM CONTROL IN COAL-FIRED APPLICATIONS

Description of different technologies and their development potentials for reducing nitrogen oxides in the exhaust gas from waste incineration plants

Oslo, February 17th, 2010

Improvements of the EGTEI Cost Calculation Tool for Emission Reduction Measures in LCPs

Continuous Mercury Monitoring at Cement Plant

CEMENT GAS CLEANING AND COOLING SOLUTIONS

Process Optimization & Plant Safety

Measurement & Analytics Measurement made easy. HP30 on-line process hydrogen analyzer Refinery hydrogen optimization

PROCESS ANALYZER FOR CLEAN COAL APPLICATIONS

Potentials and Limitations with respect to NO x -Reduction of Coke Plants

Steinmüller Engineering Conference Modernization and Optimization of Flue Gas Cleaning Plants

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Clean Coal Technologies - Bingjiang Liu

2155 Cation exchange column

Enhancing Capacity Empowering Nation. Technological Parameters in selecting systems to control emissions in Thermal Power Plants

Calculating NH 3 Slip for SCR Equipped Cogeneration Units

Calculating NH 3 Slip for SCR Equipped Cogeneration Units

Development of NOx Removal SCR Catalyst for Low SO2 Oxidation

FTIR Analyser BROCHURE

Duke Energy Seminar September 3 5, 2008 Concord, NC

Worldwide Pollution Control Association

Robust flue gas probes for industrial emissions measurements.

Steam balancing with the flowmeters VortexMaster and SwirlMaster

Study Results in Demonstration Operation of Oxyfuel Combustion Boiler for CO 2 Capture

Controlling Mercury Emissions from Coal-Fired Power Plants

PAPER PRESENTED AT 2012 POWER PLANT AIR POLLUTANT CONTROL MEGA SYMPOSIUM AUGUST 20-23, 2012 BALTIMORE, MD

Development of Air Pollutants Treatment System for Industrial Processes using Petroleum Coke

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

COAL POWER COAL BURNING POWER PLANTS

Measurement of H 2 O in Catalytic Reformer Hydrogen Recycle Streams Using Tunable Diode Laser Absorption Spectroscopy (TDLAS)

Euan Evenson Praxair, Research and Development

NOx processing experiences for removal in the CO 2 plant for the Oxyfuel combustion process

Tailor-made SNCR to Meet Future Emission Standards for Power Boilers

Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, NO formation

Recovery Boiler SCR - A Challenge and an Opportunity in Retrofit Cases

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

Control Device Technology

Transcription:

ABB MEASUREMENT & ANALYTICS APPLICATION NOTE Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process Optimize efficiency of denitrification process in DeNOx unit. Reduce downstream problems, related costs and maintenance work. Measurement made easy Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process Introduction During combustion one of the most wide-spread industrial process across all industry sectors the chemical energy present in fuels, such as coal, natural gas or oil, is converted into heat by oxidization. The heat is needed for a wide range of production processes such as generation of electricity in coal fired power plants. The flue gas contains various air pollutants, which are harmful to the environment and people. With a growing sensibility for environment protection, the reduction of air pollutants has globally attracted the attention of governments. Besides others, nitrogen oxides (NOx), which comprise nitrogen oxide (NO) and nitrogen dioxide (NO2 ), is considered to be a major cause for environmental damage. Hence, its emissions are strictly restricted by national and supranational regulations. In order to comply with the emission limits, various measures are applied, which can generally be categorized into primary and secondary measures. x Primary measures aim to avoid the formation of NOx during the combustion process itself. x In contrast, secondary measures remove the pollutant before the flue gas is released to the environment. Since primary measures tend to have insufficient efficiency levels, often secondary measures such as flue gas treatment systems play a major role for achieving the emission limits. The part of the flue gas treatment system, in which the abatement of nitrogen oxides takes place is the denitrification unit, in short DeNOx unit (refer fig. 01 on page 3).

2 Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process AN/ANALYTICAL/LS4000/101-EN Rev. B

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process AN/ANALYTICAL/LS4000/101-EN Rev. B 3 Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process 01 DeNOx unit as part of flue gas treatment on the example of a coalfired plant Measuring task Ammonia slip measurement As shown in Fig. 01, the exhaust gas from the boiler enters the DeNOx unit where nitrogen oxides are removed by a chemical reaction. For this chemical removal of NO and NO 2, a reducing agent, for example ammonia (NH 3 ), is injected into the flue gas in the headspace or upstream of the unit. The concentration of the injected ammonia is constantly regulated depending on the NO/NO 2 concentration in the exhaust gas. Even if the basic principle is identical, secondary measures can be divided into two types. An often used technology is the selective catalytic reduction (SCR), which applies catalysts to accelerate the reduction of nitrogen oxides. In contrast, the alternative selective non catalytic reduction (SNCR) does not uses catalysts, but requires higher process gas temperatures. Due to the lower required process temperatures and higher reduction rates of more than 95 %, SCR is often the preferred technology. In case of SCR, the mixture of ammonia and flue gas passes the catalysts where the nitrogen oxides are reduced on the SCR catalyst to produce elementary nitrogen and water vapor. Downstream to the SCR unit, only very few NOx and NH 3 molecules are present. The residual NH 3 concentration at the outlet is called ammonia slip, which is continuously monitored (refer fig. 01). 01 Coal bin Desulphurisation (DeSOx) Electrostatic precipitator Denitrification (DeNOx) Boiler Coal mill

4 Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process AN/ANALYTICAL/LS4000/101-EN Rev. B 01 Ammonia slip measurement in DeNOx units 02 Schematic diagram of SCR process Why is this measurement important to plant operators? In general, the motivation for the ammonia slip measurement after SCR and SNCR DeNOx units is manifold. First of all, the measurement helps plant operators with the trade-off between having sufficient ammonia present for the target conversion of NOx and the minimization of the ammonia consumption and ammonia slip at the same time. This allows to minimize the related operation costs for the reducing agent, but still to be compliant with emission limits. Secondly, the ammonia slip helps to determine the best point in time for catalyst regeneration in SCR units. If there is a trend of increasing ammonia slip at unchanged conditions, this is an indicator that the catalyst activity is decreasing. Concentration spots Thirdly, it is important to monitor the ammonia slip since it can have severe impacts on the downstream equipment. After the DeNOx outlet, unused ammonia reacts with acidic gas components present in the flue gas. This results in formation of ammonia salts, of which especially ammonium bisulphate causes problems. Due to the lower temperature downstream to the DeNOx unit, ammonium bisulphate accumulates on surfaces of downstream equipment (e.g. air preheater) leading to an increased pressure drop or in worstcase plugging of the equipment. Additionally, ammonia bisulphate in combination with water from the flue gas can also causes corrosion of downstream equipment. Finally, excess ammonia can contaminate fly ash, which is often sold as by-product to the cement industry. If the quality limits are exceeded, the ash can no longer be sold. This equals a financial loss impacting the overall profitability of operation. To sum up, this measurement helps the operator to optimize efficiency of denitrification process and reduce downstream problems, related costs and maintenance work caused by an excess of ammonia. 01 02 NOx Flue gas from boiler Other Catalyst Layers NH 3

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process AN/ANALYTICAL/LS4000/101-EN Rev. B 5 01 Clean coal power plant Applied denitrification technology The typical process conditions as well as the measuring range depend on the applied denitrification technology (i.e. SCR or SNCR). In case of SCR, the measurement range is typically in the low parts per million (ppm) range and the typical conditions for SCR are shown in Table 01 on Page 6. For SNCR, the ammonia slip and also the related measuring range are usually higher. In addition to NH 3, an optional H 2 O measurement is often conducted additionally. Traditionally used Technology Historically, extractive analyzers often with indirect, differential methods have been applied for this measuring task. However, ammonia is difficult to measure extractive due to its sticky and reactive behavior. It might be lost in the sample handling system or leads to plugging of the tubes due to the formation of ammonia salts. Since the typical measuring range is a few [ppm], a measurement technology with higher sensitivity is needed. ABB s solution ABB s LS4000 is an in-situ cross-stack analyzer applying the highly selective, optical measuring principle of tunable diode laser absorption spectroscopy (TDLAS). The device consists of a transmitter unit with a laser light source and a receiver unit with a photo detector, connected via a junction box which includes all interfaces such as power supply and analog outputs. 01 Highly selective measurement is virtually cross interference free The optical measuring principle of tunable diode laser absorption spectroscopy (TDLAS) allows a direct, virtually crossinterference free measurement. Due to the narrow spectral line width of the laser beam and the narrow scan window, only the absorption line of the target measuring component is scanned. Consequently, a high selectivity and accuracy of the measurement is achieved, which fulfills the requirements of the low ppm-level NH 3 measurement. Fast and direct A sample transport and conditioning, like used in extractive systems, is not required since the LS4000 is directly installed at the process (in-situ). This precludes the loss of ammonia in the sample system and reduces the maintenance efforts for sample handling components. Moreover, the LS4000 ensures more representative measurement since local concentration spots (e.g. due to inhomogeneity's of catalyst efficiency) can be detected by measuring across the duct. Safe, compact and easy Additionally, LS4000 s compact and lightweight housing makes LS4000 insensitive to vibrations and makes LS4000 is easier to handle. Due to its long term stability maintenance efforts for calibration are minimized.

6 Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process AN/ANALYTICAL/LS4000/101-EN Rev. B 01 Diode laser analyser LS4000 01 Diode laser analyzer LS4000 Measuring ranges Process temperature Process pressure NH3: 0... 10 to 0... 50 ppm H2O: 0... 30 to 0... 40 Vol% 250... 400 C (482... 752 F) 980... 1040 mbar abs. Dust load < 5 g/m 3 Typical open path length 2... 5 m (6.6... 16.5 ft) Table 01: Typical process conditions for NH3 slip (SCR)

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process AN/ANALYTICAL/LS4000/101-EN Rev. B 7 Notes

ABB Automation GmbH Measurement & Analytics Stierstädter Straße 5 60488 Frankfurt am Main Germany Fax: +49 69 7930-4566 Mail: cga@de.abb.com abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2017 ABB. All rights reserved. AN/ANALYTICAL/LS4000/101-EN Rev. B 08.2017