Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Similar documents
Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

Light-Metal Roof Edge, Raised

DATE R2.2 ROOF DETAILS - BUILT UP ROOF DETAILS CURBS. An Company PHONE:

WICOMICO COUNTY BOARD OF EDUCATION

UNIVERSITY OF SOUTH CAROLINA SUMTER SCIENCE BUILDING ROOF REPLACEMENT WMBE PROJECT NUMBER:

2 + 3 A-2.0 A A-2.1 A-2.0 A A '-8" A-2.0 A-2.0 A-2.0 SIM. A-2.0 A-2.0 A-2.0 SIM. A-2.0 SIM.

Schedule A Development Permit No Issued this 18 day of April, 2018

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

2017 FRENGER FOOD COURT ROOFING PROJECT

ROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

SECTION FLASHING AND SHEET METAL

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

July Minimum Fastening Requirements (Fully Adhered)... 5

ASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS

2018 FRENGER FOOD COURT ROOFING PROJECT

Fascia Systems. oofing 7.1

Tuscaloosa Police Station

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

Coal Tar Application and Design Considerations

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

The better way to build TM. Installation Manual NAILBASE PANELS

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

SECTION 07530CP EPDM MEMBRANE ROOFING

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION

Tremline. Fascia System. Installation Procedures

DISVISON 8: DOORS, WINDOWS AND GLASS SECTION 07600: SHEET METAL FLASHING AND TRIM

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL


1. Rough Carpentry for wood nailers, cants, curbs, and blocking and for wood-based, structural-use roof deck and walls: Division 6.

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

SECTION ROOF SPECIALTIES

SECTION ELASTOMERIC MEMBRANE ROOFING

TYPICAL ROOF CONDITION LAYOUT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

Pre-Fabricated Roof Curbs

C. Jointing of Exterior Vertical Surfaces. Section D. The Secretary of the US Department of the Interior s Standards for Rehabilitation.

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

GENFLEX TPO DETAILS. PIPE FLASHING T-7.01A Pipe Boot Installation - Hot Air Welded 19 T-7.01B Pipe Boot Installation - Peel & Stick 20

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

APPLICATION SAFETY TOOLS REQUIRED

Architectural Roof and Wall Products Guide Specifications

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

National Master Specification (NMS) Section SECTION INCLUDES.1 Materials and installation for modified bituminous roofing.

SECTION ADHERED SINGLE PLY MEMBRANE ROOFING

Buncombe County Schools. Project Address: 21 Trinity Chapel Road, Asheville, North Carolina Abbreviations

ROOF ASSEMBLIES CHAPTER 9

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

MEMBRANE ROOFING Christ on the Mountain

SECTION BUILT-UP BITUMINOUS WATERPROOFING

Architectural Roof and Wall Products Guide Specifications

ROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only

CONSTRUCTION DETAILS TABLE OF CONTENTS

ADDENDUM NO. 1. Applied Science South Roof Replacement MURRAY STATE UNIVERSITY, MURRAY, KY PROJECT #

Engineering Services Program

SSL-175. Specifications

REROOFING ANALYSIS OF K-12 BUILDING. Unified School District 306 Gypsum, Kansas

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

FORTIFIED Home High Wind. Bronze New Roof Requirements

METACRYLICS ACRYLIC ROOF TOP PENETRATION ROOF DETAILS

GAF EnergyGuard Polyiso Wall Sheathing

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

Sheet Metal Flashing and Trim

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

SCOPE OF WORK PROJECT IDENTIFICATION

COMMERCIAL ROOFING SYSTEMS

Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

AIA MODIFIED BITUMEN AUGUST 2016

Shepard & Associates, LLC

SPECIFICATION: GUIDE SPECIFICATIONS FLEXIBLE SHEET ROOFING C3 MECHANICALLY FASTENED. Republic Powdered Metals, Inc. Revised 01/2002 PART 1 -- GENERAL

Asphaltic Accessories Brochure

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

EverGuard Plaza Deck Roofing For Above-Grade Plaza Deck Applications

SECTION TOPSHIELD GUIDE SPECIFICATION SMOOTH AND GRANULE SURFACE ROOF RESTORATION TS-AC yr

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #2, January 26, 2017

ROOF ASSEMBLIES CHAPTER 9

Scope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building.

UBC Technical Guidelines Section Edition Membrane Roofing Page 1 of 7..1 Section Building Envelope General Requirements

SECTION FLASHING AND SHEET METAL

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

G October 2018

Roofing Products International Re-Flex TPO Fully Adhered Installation Specification

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

DL-200. Specifications

J41 Reinforced bitumen membrane roof coverings

Product Technical Bulletin SPM-4H-250

G October 2018

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Procurement and Contracting Services

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

TECHNICAL INFORMATION

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

ROOFING APPLICATION STANDARD (RAS) No. 120 MORTAR AND ADHESIVE SET TILE APPLICATION

DIVISION 7 THERMAL AND MOISTURE PROTECTION

Roof Replacement Specifications Section METHOD SPECIFICATONS, ROOF REPLACEMENT AT THE LOG COLLEGE MIDDLE SCHOOL. CENTENNIAL SCHOOL DISTRICT:

Options In Flashing for Asphaltic and Single-Ply Systems Brochure

Shepard & Associates, LLC

Product Technical Bulletin APS-5T

Transcription:

Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan Student Union 1400 Greene Street Columbia, 29208 1 05/15 No. Revision/Issue T-1 (Title ) 1 of 8

Notes: HVAC Unit sits on roof surface (to be replaced with new curb) Roof Key: Roof Drain Vent on Plumbing Vent Wood Sleeper Equipment Rail Wood sleepers (to be replaced with curb) Pitch Pan Coping Equipment Outline Water Lines Downspouts From Upper Roof Elevations Leader From Upper Roof Elevation Items to be removed 1 05/15 No. Revision/Issue Box on Roof (To be placed on new curb) R-1 Existing Roof Plan w/ Demolition 2 of 8

Roof Access +1.6" +5.2" D-9 Notes: Indicated insulation thickness must be confirmed by shop drawings. Thicknesses indicated are for tapered insulation only and do not include insulation base layer or coverboard New +3.8" New Water line support locations are shown on Mechanical Drawing (M-1) Keys to specific details are provided for clarity Roof Key: +2.9" +3.1" Roof Drain w/ 4' x 4' sump where insulation thickness allows +1" New +2.4"" Cricket Vent on Plumbing Vent Equipment Rail Coping +5" +3.6" Pitch Pan Conduit Support Equipment Outline +3.9" +3.8" +2.25" Water Lines Downspouts From Upper Roof Elevations Leader From Upper Roof Elevation Slope Direction Indicator D-8 +2.4" 1 05/15 No. Revision/Issue New D-1 D-11 +5.5" Cricket R-2 New Roof Plan +2.7" 3 of 8

LEAD WEDGE AT APPROX. 24'' O.C. APPROPRIATE SEALANT FRICTION FIT SHEET-METAL REGLET--INSERT IN RAGGLE JOINT APPROPRIATE FASTENERS APPROX. 24'' O.C. 3'' LAP WITH BEAD OF SEALANT REMOVABLE SHEET-METAL COUNTERFLASHING OPTIONAL: SEALANT OR ELASTOMERIC TAPE APPROPRIATE SEALANT TOOLED TO FACILITATE RUNOFF APPROPRIATE FASTENERS APPROX. 12'' O.C. ONE-PIECE SHEET-METAL COUNTERFLASHING APPROX. 3'' LAP AT JOINT OPTIONAL: 2'' WIDE CLIP APPROX. 30'' O.C. APPROX. 1/2'' GAP 6" MIN. SHEET-METAL JOINT COVER SET IN SEALANT ON EACH SIDE COPING COPING WITH COVER PLATE OPTIONAL: METAL FLANGE EXTENSION GASKETED FASTENERS AT APPROX. 18'' O.C. DEPENDING ON WIND ZONE AND LOCAL CONDITIONS APPROPRIATE FASTENERS FASTENED APPROX. 6'' O.C. CONTINUOUS CLEAT CONTINUOUS CLEAT AND GASKETED FASTENERS Contractor Notes: APPROX. 3'' LAP AT JOINTS OPTIONAL: 2'' WIDE CLIP APPROX. 30'' O.C. COVER PLATE SEAM CLEAT AND CLIP INFORMATION 3 CLEAT/CLIP THICKNESS TO BE ONE GAUGE HEAVIER THAN COPING METAL 2'' MIN. INSERT REGLET AND COUNTERFLASHING WITH OVERLAP JOINT TWO-PIECE COUNTERFLASHING SURFACE MOUNTED COUNTERFLASHING APPROX. 3/4'' APPROX. 3/4'' 3/4" MIN. METAL CAP HEMMED EDGE TYPICAL CLEAT ENGAGEMENT TYPICAL CLIP ENGAGEMENT METAL COPING FASTEN APPROX. 3'' TO 6'' O.C. STAGGERED (USE 3" SPACING FOR ANSI/SPRI ES-1 COMPLIANCE), WITH CORROSION-RESISTANT, BARBED, ANNULAR RING OR SCREW SHANK NAIL. LENGTH TO ACHIEVE APPROX. 1 1/4'' PENETRATION INTO NAILER BEND FLANGE AT ROOF SIDE CAP SHEET UP TO 1 1/2'' APPROX. 1/2'' GAP 6" MIN. OPTION APPROPRIATE FASTENERS APPROX. 3" TO 6" O.C. STAGGER PATTERN VARIES PER ROOF SYSTEM SHEET-METAL COVER PLATE SET IN SEALANT MEMBRANE STRIPPING SHEET SHEET-METAL GRAVEL STOP-- SEE NOTES 4 AND 5 APPROX. 4" 1 05/15 No. Revision/Issue 3 to 6 inches max. 3'' MIN. FLANGE APPROX. 1/2'' GAP ROOF SIDE APPROPRIATE FASTENERS APPROX. 3" TO 6" O.C. STAGGER PATTERN VARIES PER ROOF SYSTEM SHEET-METAL COVER PLATE SET IN SEALANT PERIMETER EDGE METAL OPTIONAL: COMPATIBLE SEALANT AT JUNCTION OF MEMBRANE AND EDGE METAL SET FLANGE IN COMPATIBLE ROOF CEMENT AND PRIME FLANGE BEFORE STRIPPING EMBEDDED EDGE (A-TYPE) 6" MIN. FACE SIDE ONE PLY OR SEPARATE MEMBRANE SHEET EXTENDED BELOW BLOCKING 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE-- OVERALL THICKNESS TO MATCH INSULATION POLYMER-MODIFIED BITUMEN PLY SHEET D-1 (Roof Details) PERIMETER EDGE-METAL SECUREMENT PERIMETER EDGE METAL WITH COVER PLATE D-1 EMBEDDED EDGE METAL FLASHING GENERAL SHEET METAL REQUIREMENTS 4 of 8

SEALING MATERIAL CONCRETE CURB ROOFTOP EQUIPMENT FRAME GASKETED FASTENERS-- MIN. TWO FASTENERS PER SIDE EXTENDED FIELD PLIES ABOVE TOP OF WOOD NAILER ROOFTOP EQUIPMENT FRAME GASKETED FASTENER--MIN. TWO FASTENERS PER SIDE REMOVABLE SHEET-METAL COUNTERFLASHING-- SEE NOTES 8 AND 9 ADHERED TO (FOR TORCH- APPLIED SYSTEMS--SEE NOTE 5) FASTENERS APPROX. 8'' O.C.--MIN. TWO FASTENERS PER SIDE TOP OF FLASHING CAPPED OR ROLLED INTO PIPE APPROXIMATELY 1'' SOFT METAL PIPE FLASHING-- SEE NOTE 1 PLUMBING VENT STACK OPTIONAL: COMPATIBLE ROOF CEMENT OR COMPATIBLE SEALANT AT PENETRATION- TO-MEMBRANE JUNCTURE CAP SHEET Notes: OPTIONAL: EXTENDED FIELD PLIES ABOVE TOP OF 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE--OVERALL THICKNESS TO MATCH INSULATION D-2 BASE FLASHING AT CONCRETE CURB LOCATIONS MOP- OR COLD-APPLIED ADHERED TO OPTIONAL CURB-BEARING LOCATION FOR HEAVYWEIGHT-LOADING CONDITIONS PREFABRICATED METAL CURB 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE-- OVERALL THICKNESS TO MATCH INSULATION D-3 BASE FLASHING AT STEEL CURB LOCATIONS (FOR TORCH- APPLIED SYSTEMS: SELF-ADHERING SHEET, MOPPED POLYMER-MODIFIED BITUMEN BASE SHEET OR TWO TYPE IV PLIES MOPPED) WITH SEALED LAPS D-4 PLUMBING VENT MEMBRANE STRIPPING SHEET PLY SHEET SET FLANGE IN COMPATIBLE ROOF CEMENT--PRIME FLANGE BEFORE STRIPPING. SHEET-METAL RAIN COLLAR OVERLAPPING PENETRATION POCKET WITH APPROPRIATE SEALANT (E.G., POLYURETHANE) AND DRAWBAND 2" APPROX. POURABLE SEALANT CAP SHEET 1'' MIN. POLYMER-MODIFIED BITUMEN CAP SHEET POLYMER-MODIFIED BITUMEN MEMBRANE STRIPPING SHEET POLYMER-MODIFIED BITUMEN PLY SHEET WEATHERPROOF SHEET- METAL RAIN COLLAR OVERLAPPING PENETRATION POCKET WITH APPROPRIATE SEALANT (E.G., POLYURETHANE) 2" APPROX. POURABLE SEALANT APPROVED FOR USE WHERE PITCH PANS CANNOT BE INSTALLED MEMBRANE STRIPPING SHEET PLY SHEET COMPATIBLE ROOF CEMENT OR COMPATIBLE SEALANT AT PENETRATION-TO- MEMBRANE JUNCTION 1 No. Revision/Issue NONSHRINK GROUT WEATHERPROOF SHEET-METAL PENETRATION POCKET OPTIONAL: COMPATIBLE ROOF CEMENT OR COMPATIBLE SEALANT AT PENETRATION-TO- MEMBRANE JUNCTURE FLANGE SET IN COMPATIBLE ROOF CEMENT OVER FIELD PLIES--PRIME FLANGE BEFORE STRIPPING NONSHRINK GROUT WEATHERPROOF SHEET-METAL PENETRATION POCKET FLANGE SET IN COMPATIBLE ROOF CEMENT-- PRIME FLANGE BEFORE STRIPPING LIQUID-APPLIED REINFORCED FLASHING SEAL AROUND PENETRATION WITH COMPATIBLE SEALANT APPROX. 6" D-2 (Roof Details) D-5 PENETRATION POCKET--SINGLE PENETRATION D-6 PENETRATION POCKET--MULTIPLE PENETRATIONS D-7 PIPE PENETRATION (LIQUID-APPLIED FLASHING SYSTEM) 5 of 8

3/4" EXTERIOR GRADE PLYWOOD W/ ICE & WATERSHIELD ON BACK SIDE INSTALL APPROPRIATE SEALANT (E.G., SILICONE) AND TOOL TO FACILITATE WATER RUNOFF CONCRETE FASTENERS SHEET-METAL COUNTERFLASHING-- SEE NOTES 5 AND 6 COMPRESSIBLE ELASTOMETRIC SEALANT OR TAPE TO SPAN IRREGULARITIES SEAL TOP OF FLASHING WITH A COMPATIBLE VERTICAL-GRADE ROOF CEMENT AND REINFORCEMENT PRIME CONCRETE TO TOP OF BASE FLASHING OPTIONAL: EXTENDED FIELD PLIES ABOVE TOP OF ADHERED TO EXISTING WINDOW 18 GAUGE STEEL FASTENED TO WINDOW FRAME. SEALANT GASKET AT PERIMETER INSTALL APPROPRIATE SEALANT (E.G., POLYURETHANE) AND TOOL TO FACILITATE WATER RUNOFF FASTENERS SHEET-METAL COUNTERFLASHING COMPRESSIBLE ELASTOMETRIC SEALANT OR TAPE TO SPAN IRREGULARITIES SEAL TOP OF FLASHING WITH A COMPATIBLE VERTICAL-GRADE ROOF CEMENT AND REINFORCEMENT PRIME CONCRETE TO TOP OF BASE FLASHING EXTENDED FIELD PLIES ABOVE TOP OF ADHERED TO SHEET-METAL RECEIVER WITH REMOVABLE COUNTERFLASHING SEAL TOP OF FLASHING WITH A COMPATIBLE VERTICAL-GRADE ROOF CEMENT AND REINFORCEMENT NONCOMBUSTIBLE SUBSTRATE, PRIME SURFACE AS REQUIRED OPTIONAL: EXTENDED FIELD PLIES ABOVE TOP OF ADHERED TO (FOR TORCH-APPLIED SYSTEMS : SELF-ADHERING SHEET, MOPPED POLYMER- MODIFIED-BITUMEN BASE SHEET Notes: D-8 BASE FLASHING WITH SURFACE MOUNTED COUNTERFLASHING D-9 BASE FLASHING WITH SURFACE MOUNTED COUNTERFLASHING (FOR USE AT DECORATIVE CONCRETE BLOCK LOCATIONS ONLY) (FOR USE AT WINDOW LOCATION ONLY) D-10 BASE FLASHING WITH TWO-PIECE SHEET-METAL COUNTERFLASHING CONTINUOUS WEATHERPROOF MEMBRANE ON TOP OF DIVIDER TURNED DOWN BOTH SIDES ALUMINUM STRAINER DOME SHEET-METAL COPING SLOPED TO DRAIN TO ROOF SHEET-METAL COVER-- SEE NOTES 4 AND 5 SLOPE CONTINUOUS WEATHERPROOF MEMBRANE ON TOP OF WALL TURNED DOWN BOTH SIDES METAL STUD WITH SELF LOCKING NUT ALUMINUM CLAMPING RING FLANGE FASTENER D-11 BASE FLASHING WITH METAL COPING WOOD NAILER ATTACHED TO SUBSTRATE PRIME SURFACE AS REQUIRED EXTENDED FIELD PLIES ABOVE TOP OF MOP- OR COLD-APPLIED ADHERED TO 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE--OVERALL THICKNESS TO MATCH INSULATION D-12 CONCRETE EXTENDED FIELD PLIES ABOVE TOP OF MOP- OR COLD-APPLIED ADHERED TO BASE FLASHING AT EQUIPMENT SUPPORT RAIL & ROOF ACCESS (FLASHING TO THE ROOFSIDE ONLY FOR ACCESS) D-13 CAP SHEET BASE SHEET INSULATION SLOPED TO DRAIN WOOD NAILER WOOD NAILER FASTENER RETROFIT ROOF DRAIN COLD ADHESIVE SEALANT REINFORCING PLY EXISTING DRAIN BOWL CONCRETE DECK DRAIN BODY EXISTING RAIN WATER LEADER MECHANICAL WATERTIGHT CONNECTION SEAL 1 No. D-3 (Roof Details) Revision/Issue 6 of 8

Swygert & Associates