DS-520 Digital Indicator Operation Manual 73366

Similar documents
DC-688. When Accuracy Counts

RL4050LS. Electronic Load Shackle. Installation Guide

DMC When Accuracy Counts

RL8000HE/RL8500HE Load Cell Mounting Kit. Installation Guide

Operation Instructions

WS 10 Weighing indicator USER MANUAL

Sby SR Instruments, Inc.

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

BC Series Compact Counting Scale INSTRUCTION MANUAL

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

Owner s Manual & Safety Instructions

Model HH Signal-Conditioner / Indicator

WeighSouth. WBT Toploader Balance

CN Series P.N , Software rev. T 8, Revision A1- July 2014

DIGITAL PORTION SCALE PS-5 OWNER S Manual

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

LOW PROFILE FLOOR SCALE

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

DIGITAL PLATFORM SCALE

PD662 LOOP-POWERED METER

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

HDI 2200 Choke Position Indicator

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Drag Chain Conveyor Installation and Operation Manual

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

MODEL ASCS-15 CRANE SCALE

Engineering Specifications

Thermoelectric Cooler

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

8 DIAL CALIPER. Model Diagrams within this manual may not be drawn proportionally.

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

LC-VS 60 Operation Manual

SERVICE MANUAL. Model: DS-425. Edition Month Year 1 st September nd December rd April th January 2002

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

E3X-DRT21/SRT21/CIF11

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

BA110 Electronic Balance 5000g x 1g. Impact Test Equipment Ltd & User Guide. User Guide

Model M130 Mini Anemometer

Inscale Measurement Technology Ltd Tel: Fax:

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

User Guide M Rev A 09/15

OPERATION MANUAL. Model : DC-190 TERAOKA SEIKO CO., LTD. Edition Month Year October 1998

Shower Column SHCM Installation Guide

PORTION CONTROL SCALE

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

92831 TEL: (714) FAX:

Festoon Manual Heavy Duty C-Track

Model E100 Gauss Meter

Effective This guide supersedes all previous versions

General-Purpose Scale Bases

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

VN Series Floor Scale Instruction Manual

LOAD RAMP 1000 LB. CAPACITY

Stretch Wire. P/N Rev. 2. IOM Stretched wire festoon manual

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

EGT-AF08 USER GUIDE WHEEL WEIGHING SYSTEMS WITH VARIOUS PLATFORMS

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Model M120 Mini Temperature/Humidity Meter

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

SAVE THESE INSTRUCTIONS

Dynatronics Parallel Bars

PD662 LOOP-POWERED METER Instruction Manual

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

INSTALLATION PROCEDURE

92831 TEL: (714) FAX:

WARNING. Introduction ! ATTENTION

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

Pallet Jack 4,400 Lbs Capacity Model #31001

4 rotary milling table

EC Type-Approval Certificate

INSTALLATION PROCEDURE

LIGHT CONTROLLER LC 500

ASTM D 991 TEST FIXTURE

Owner s Manual & Safety Instructions

TL-600 MOBILE PHASE HEATER

Installation Manual. Omnicell. Model: 9102 FB by Fairbanks Scales, Inc. Revision 4 08/16 All rights reserved

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

VISE MOUNTED. Model 97359

MANUAL JCE-SERIES CHAPTER

Wash Down Duty Non-Contact Sensor

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

MS 3801 USER MANUAL. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.

OPERATION AND MAINTENANCE MANUAL. (For Owner s Use Only)

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

SPECIFICATIONS. Model CSW-10AT-LT Electronic Lift Truck Scale: Operating Temperature: 14 to 140 deg. F (-10 to 60 deg. C)

DRYWALL DOLLY 900 LB. CAPACITY

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SWM-1 Loudspeaker Wall Mount Device. P/N: Rev 1

DUST FREE ACTIVE Total Home Air Purification

Transcription:

DS-520 Di gi tal Indi cator Operation Manual 73366

SECTION DS-520 SERIES OPERATING MANUAL INDEX PAGE NUMBER 1.0 GENERAL 2-3 1.1. Features 2 1.2. Keyboard & Display Layout 2 1.3. Key Switch Information 3 1.4. Indicator Lamp Information 3 2.0 SPECIFICATIONS 4 2.1 Technical Specifications 4 3.0 INSTALLATION 5-6 3.1 Un-packing 5 3.2 Inspection 5 3.3 Re-packing 5 3.4 Un-locking Procedure 5-6 4.0 DS-520 OPERATIONAL PROCEDURES 7-8 4.1. Power On/Off 7 4.2. Automatic Shut Off 7 4.3. Re-zero 8 4.4. Tare Reduction 8 5.0 MAINTENANCE MODE 9-12 5.1. Spec Entry 9 5.2. Spec Entry and Span Adjustment 9-10 5.3. Internal Count and A/D Count Display 10 5.4. Spec List 11 5.5. Error Messages 11 5.6. Maintenance, Calibration, Test Procedures & Service 12 1

1.0. GENERAL 1.1. Features Wash down (IP-65) digital weighing scale Quick response to weight changes Capacity: 60 lb, 150 lb, 300 lb Resolution: A. Display resolution1/1000 (multi range) internal res.1/6000 B. Display resolution1/3000 (single range) internal res. 1/24000 Low power consumption : 6 x C cell batteries for more than 200 hours of continuous use Fast self test procedure when power on Selectable automatic shut off time which prolongs battery life Two point low battery detect: A. When battery is weak, the battery indicator will light B. When the power from the battery becomes too low to weigh accurately, all displays will shut off except the battery indicator. The power is shut off after 1 minute. Calibration by software High contrast LCD display 3 keys REZERO key, TARE key, ON/OFF key Stainless steel platform and indicator housing 1.2. Keyboard & Display Panel Layout 2

1.3. Key Functions REZERO Key TARE Key ON/OFF Key Reset weight display to zero Set or clear a tare Turn the power ON or OFF 1.4. Indicators Lamps Zero On when zero point is adjusted and when weight is stable Net On when tare reduction is performed Battery On when battery is weak 3

2.0. SPECIFICATIONS 2.1.1. Technical Specifications This section includes a detailed listing of all pertinent specifications and parameters for the DS-520 weighing scales. The system weighing accuracy is 0.03 %. All models meet or exceed the requirements of OIML, Class III, and NIST Handbook, Number 44. 2.1.2. Operating conditions Power source Operating temperature Operating humidity Power consumption 12VDC w/dc adapter or 9VDC w/6 C cell battery -10 C +40 C (OIML) 15 85% RH 0.07w when 6V, 0.1w when 9V 2.1.3. Analog specification Input sensitivity 0.67mV/V- 10kg & 20kg, all other capacities 1mV/V Zero adjust range 40% Full Scale Zero balance range 10% Full Scale L/C applied voltage DC 5V Speed of A/D conversion 4 times /sec. Internal resolution 16000 or 24000 2.1.4.Display Specification Weight display Spec Display Decimal Point 6 digits with ZERO, TARE, LOW BATTERY indication 6 digits Spec Selectable 2.1.5. Dimensions Platter size Overall size Tall column 16"L x 16"W x 4 _"H 22 _"L x 16"W x 4 _"H 18 _"L x 16"W x 36" Overall height 2.1.6. External connectors DC receptacle 4

3.0. INSTALLATION This section provides the information required for installing this weighing system for operation. The following steps accomplish installation. 1. Unpacking 2. Set-up Procedure 3.1. Unpacking Each component of the DS-520 system is packed in a specially designed carton. Remove each component from its carton, separate the component from its polystyrene shell assembly and set aside. Inspect the carton interior to be sure that all accessories have been removed from the carton. Inspect the carton inner panels for accessories. NOTE: Be sure to repack all materials within the carton set. Store the cartons in a secure area so they can be available whenever future shipment of the scale is required. 3.2. Inspection Immediately after unpacking, a visual inspection of the scale should be performed. If any damage has been incurred during transportation notify the shipper and Rice Lake Weighing systems immediately. Instructions for assessment of damage and further procedures will then be determined. 3.3. Repackaging If, at anytime, the DS-520 weighing scale must be returned for modification, calibration, or repair, be sure that it is properly packed with sufficient cushioning materials. Whenever possible, the original carton assembly should be retained for this purpose. Any damage caused by improper packaging will not be covered by warranty. 3.4. Unlocking Procedure The unlocking procedure is included on the next page. The DS-520 should be properly locked whenever it is being transported. See next page for un-locking procedure. NOTES: Remove 4 M6 screws and lock bracket as shown on page 6. Also check the overload stop. Ensure that nut is screwed tightly. Locking procedure should include tightening nut until it fully stops. 5

Unlocking Procedure (Continued) 6

4.0. DS-520 OPERATIONAL PROCEDURES 4.1. Power On/Off 1. Press [ON/OFF] key to turn on the scale. The display will briefly show all segments, then blank for a second, then go into weighing mode. 2. Press [ON/OFF] key to turn off the scale. 4.2. Automatic Shut Off Timer Setting 1. Begin with the scale turned off. 2. Press and hold the [ON/OFF] key for 3 seconds. This sets the Timer for 3 minutes. 3. Release the [ON/OFF] key when the display shows the number 3. The display will then briefly show all segments, then blank for a second, then go into weighing mode. 1. Begin with the scale turned off. 2. Press and hold the [ON/OFF] key for 6 seconds. This sets the Timer for 10 minutes. 3. Release the [ON/OFF] key when the display shows the number 6. The display will then briefly show all segments, then blank for a second, then go into weighing mode. 1. Begin with the scale turned off. 2. Press and hold the [ON/OFF] key for 9 seconds. This sets the Timer for no auto shut off. 3. Release the [ON/OFF] key when the display shows the number 999. The display will then briefly show all segments, then blank for a second, then go into weighing mode. 7

4.3. Rezero Example 1 Begin in the weighing mode with the scale showing 0.00 Example based on 60 lb scale. 1. Place 20 lb on the scale. 2. Press the [REZERO] key. The display will show all segments briefly, then go to 0.00 Example 2 Begin in the weighing mode with the scale showing 0.00 Example based on 60 lb scale. 1. Place 25 lb on the scale. 2. Press the [REZERO] key. The display will show all segments briefly, then go to 25.00. 25lb exceeds the 40% limit of the rezero range. 4.4. Tare Example : Begin in the weighing mode with the scale showing 0.00 Example based on 60 lb. scale. 1. Place 20 lb on the scale. 2. Press the [TARE] key. The display will go to 0.00 3. Remove weight from scale. The display will go to -20.00 4. Press the [TARE] key. To clear the tare 8

5.0. MAINTENNCE MODE 5.1. Specification Entry Example : Begin in the weighing mode with the scale showing 0.00 1. Press and hold [REZERO] key, while holding the [REZERO] key, press [TARE] [TARE] [ON/OFF] then release the [REZERO] key. The display will show all 8 s while holding the [REZERO] key, when the [REZERO] key is released the scale will be in the Maintenance Mode. 2. Press the [TARE] key. The display will show the software version. 3. Press the [TARE] key. The display will show S0 0 0 0 (spec 0 = 0 0 0) 4. Press the [ON/OFF] key. To change spec data (0 0 0 1 1 1) Ex: Press [ON/OFF] S0 0 0 1, Press [ON/OFF] S0 0 1 0, Press [ON/OFF] S0 0 1 1, 5. Press the [TARE] key. To store spec data and advance to the next spec. S1 0 0 0 6. Press the [REZERO] key. To save specs to memory and return to the weighing mode. 5.2. Specification Entry and Span Adjustment Example : Begin in the weighing mode with the scale showing 0.00 1. Press and hold [REZERO] key, while holding the [REZERO] key, press [TARE] [TARE] [ON/OFF] then release the [REZERO] key. The display will show all 8 s while holding the [REZERO] key, when the [REZERO] key is released the scale will be in the Maintenance Mode. The display will show d5-671. 2. Press the [TARE] key. The display will show the software version. 3. Press the [TARE] key. The display will show S0 0 0 0 (spec 0 = 0 0 0) 4. Press the [ON/OFF] key. To change spec data (0 0 0 1 1 1) Ex: Press [ON/OFF] S0 0 0 1, Press [ON/OFF] S0 0 1 0, Press [ON/OFF] S0 0 1 1, 9

5. Press the [TARE] key. To store spec data and advance to the next spec. S1 0 0 0 6. Press the [TARE] key. To store spec data and advance to the next spec. S2 0 0 0 7. Press the [TARE] key. To store spec data and advance to the next spec. S3 0 0 0 8. Press the [TARE] key. The display will show CAL 00 9. No Weight Should Be On Platter. Press the [TARE] key. The display will show - - - - - - - while the scale calibrates the zero point. When zero is calibrated the display will show CAL SP 10. Place Capacity Weight On Platter. Press the [TARE] key. The display will show - - - - - - while the scale calibrates the span. When span is calibrated the scale will return to the weighing mode. 60.00 NOTE: To exit maintenance mode, Press the [REZERO] key at any step except when - - - - - - are displayed. 5.3. Internal Count Display : Example : Begin in the weighing mode with the scale showing 0.00 1. Press and hold [REZERO] key, while holding the [REZERO] key, press [TARE] [TARE] [ON/OFF] then release the [REZERO] key. The display will show all 8 s while holding the [REZERO] key, when the [REZERO] key is released the scale will be in the Maintenance Mode. The display will show d5-671. 2. Press the [ON/OFF] key. To display the Internal (Span) Count 3. Press the [ON/OFF] key. To display the Internal (Zero) Count 4. Press the [ON/OFF] key. To display the Internal(Span) Count 5. Press the [TARE] key. To store spec data and advance to the next spec. S1 0 0 0 10

5.4. Specification List Spec no. Bit 2 Bit 1 Bit 0 S0 Decimal Point Position 0 0 0 = no decimal point 1 0 0 = 5 th digit (00.0000) 0 0 1 = 2 nd digit (00000.0) 1 0 1 = 6 th digit (0.00000) 0 1 0 = 3 rd digit (0000.00) 1 1 0 1 1 1 = not used 0 1 1 = 4 th digit (000.000) S1 Decimal Point Type 0 = period 1 = comma ZERO Lamp ON 0 = gross 0 1 = net 0 Zero Tracking when Tare 0 = no, 1 = yes S2 Minimum Display 0 0 0 = 1 0 1 0 = 5 1 0 0 = 20 0 0 1 = 2 0 1 1 = 10 101-111 not used S3 S4 S5 Display Resolution 0 0 = 1/1000 (multi-interval) 0 1 = 1/2000 (single-interval) 1 0 = 1/3000 (single-interval) 1 1 = not used Not Used Not Used Multi-Interval Setting 0 = net multi- interval 1 = gross multi-interval S6 Auto Tare Clear V 1.21 0=yes, 1=no 5.5. Error Message List The following message will appear when an invalid operation is performed Message Remark Appropriate Operation OF When displayed weight on scale exceeds capacity by +9d, Remove weight from scale or weight is on platter when power up UF When displayed minus weight >= 9d Rezero scale, turn off and on 888888 A/D checking error or scale not stable on power up. Place scale on firm flat surface and level it. Calibration is not correct, or A/D checking error on power up Repeat calibration procedure ERROR 0.00 Low battery indication when input voltage is low. Weight Display blanks when voltage is below min. level. Low battery indication goes off as the battery is drained. Change batteries or check power supply Change batteries or check power supply 11

5.6. Maintenance, Calibration, Test Procedure & Service This section contains information and instructions concerning maintenance of the DS-520 Weighing Scale. Preventive maintenance consists of periodically cleaning the external surfaces of the instrument and should be performed as often as operating conditions warrant. The calibration procedure is designed to be an aid in maintaining the scale accuracy within specifications. The calibration procedure may also serve as a performance test procedure. CAUTION: DO NOT ATTEMPT ANY SERVICE WHILE THE INSTRUMENT IS CONNECTED TO THE POWER SOURCE. 5.6.1. Maintenance Procedures 5.6.1.1. EXTERIOR MAINTENANCE The exterior surfaces of the counting scale can be easily cleaned using soap and water. For grease or other difficult spots, a chlorothane or naptha based cleaner may be used. 5.6.1.2. Internal Maintenance Internal maintenance is not normally required and if it is, should not be attempted except by a qualified, authorized service technician. 5.6.2. Calibration The following procedure should be followed periodically (every six to twelve months is suggested) to determine that the scale is functioning in all modes. A. Electrical Follow section 4.0 through all its steps B. Accuracy Weighing: The scale weighing accuracy can be determined by applying various known weights to the platform. Because of the scale's very high accuracy, only weights that are certifiably more accurate than the scale's specifications should be used in testing for accuracy. (NIST class "F" or higher) Since the scale owner does not normally have such certifiable weights available, it is suggested that the customer call their authorized DIGI dealer. 5.6.3. Service & Repair No service or repair should be attempted except by qualified personnel, and not until it has been positively determined that the weighing scale requires such service. All service should be done in a clean, dry, dust-proof area. 12

DS-520 Limited Warranty Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the Distributor/OEM and accepted by RLWS. All systems and components are warranted against defects in materials and workmanship for two (2) years. RLWS warrants that the equipment sold hereunder will conform to the current written specifications authorized by RLWS. RLWS warrants the equipment against faulty workmanship and defective materials. If any equipment fails to conform to these warranties, RLWS will, at its option, repair or replace such goods returned within the warranty period subject to the following conditions: Upon discovery by Buyer of such non-conformity, RLWS will be given prompt written notice with a detailed explanation of the alleged deficiencies. Individual electronic components returned to RLWS for warranty purposes must be packaged to prevent electrostatic discharge (ESD) damage in shipment. Packaging requirements are listed in a publication, Protecting Your Components From Static Damage in Shipment, available from RLWS Equipment Return Department. Examination of such equipment by RLWS confirms that the non-conformity actually exists, and was not caused by accident, misuse, neglect, alteration, improper installation, improper repair or improper testing; RLWS shall be the sole judge of all alleged non-conformities. Such equipment has not been modified, altered, or changed by any person other than RLWS or its duly authorized repair agents. RLWS will have a reasonable time to repair or replace the defective equipment. Buyer is responsible for shipping charges both ways. In no event will RLWS be responsible for travel time or on-location repairs, including assembly or disassembly of equipment, nor will RLWS be liable for the cost of any repairs made by others. THESE WARRANTIES EXCLUDE ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NEITHER RLWS NOR DISTRIBUTOR WILL, IN ANY EVENT, BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. RLWS AND BUYER AGREE THAT RLWS S SOLE AND EXCLUSIVE LIABILITY HEREUNDER IS LIMITED TO REPAIR OR REPLACEMENT OF SUCH GOODS. IN ACCEPTING THIS WARRANTY, THE BUYER WAIVES ANY AND ALL OTHER CLAIMS TO WARRANTY. SHOULD THE SELLER BE OTHER THAN RLWS, THE BUYER AGREES TO LOOK ONLY TO THE SELLER FOR WARRANTY CLAIMS. No terms, conditions, understanding, or agreements purporting to modify the terms of this warranty shall have any legal effect unless made in writing and signed by a corporate officer of RLWS and the Buyer. 2003, Rice Lake Weighing Systems, Rice Lake, WI USA. All rights reserved RICE LAKE WEIGHING SYSTEMS 230 WEST COLEMAN STREET RICE LAKE, WISCONSIN 54868 USA 13