On Site Detention System.

Similar documents
Is this the best OSD system ever?

Technical items. It is the simple, clever things that make the difference. Consider:

Maelstrom. Installation and Specification Guide

ultimate high performance

EnviroModule TM 2. modular underground tank systems. rainwater harvesting infiltration on-site detention bio-remediation filtration

ENVIROMODULE 2 DESIGN AND INSTALLATION GUIDE. Assembly Excavation Installation Backfilling Pipe Connections Design Examples Structural Design

Versatile Rectangular Underground Concrete Tank. Recommended Install Guidelines

UNDERGROUND Rainwater Harvesting

Ecosol Rain Tank Maintenance Guide. environmentally engineered for a better future. Ecosol WASTEWATER FILTRATION SYSTEMS

EnviroModule TM 2 installation guide

PROPOSED THREE-STOREY RESIDENTIAL APARTMENT BUILDING SITE LOT 19 R-PLAN ROCKINGHAM AVENUE CITY OF OTTAWA STORM DRAINAGE REPORT

Complete Modern Drainage System

Introduction. Installation

first flush water diverters water quality first downspout, post/wall mounted and in-ground diverters

Easy As 1, 3. Surface Water Drainage Solution

> Pre-installation reference guide Toroid underground tanks >

> Pre-installation reference guide

PROPOSED THREE STOREY RESIDENTIAL APARTMENT BUILDING SITE LOT 47 R PLAN CROYDEN AVENUE CITY OF OTTAWA STORM DRAINAGE REPORT REPORT R

Concrete Water Tanks - 16,400 to 160,000 lt

product guide USA EDITION 2013 Your own sustainable water supply

The Everhard EasyDRAIN system provides everything you need to create an effective, fully integrated surface water drainage system.

First Flush Water Diverters Quality First

Chapter 5 Hydraulic Structures

Section 12 Hydraulics.

Standard products Tasmania 2010

component developments Stainless Steel Industrial Floor Drainage

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

HDPE WATER CONTROL DEVICES

Sump Pumps Office procedures for the Drainage & Grading section

Ecosol Rain Tank Technical Specification. environmentally engineered for a better future URBAN ASSET SOLUTIONS

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Stormwater Disposal to Soakpits

How To Construct a Ferro Cement Tank

Complete Drainage System

P rota n k. Superior Stormwater Management INFILTRATION DETENTION HARVESTING WASTE

MEA GaLa Garden & Landscaping / DIY

Biotec 1-4 Package Sewage Treatment Plants

SEPTIC TANK CONSTRUCTION GUIDELINES

Bushfire Design Guide

IRRIGREY GUIDE GREYWATER REUSE

Floor drain armatures

Industries. Rain Water Tanks

Beacon Hill Water & Sewer District Standard Specifications

Metal Detention/Retention Products

Polymer Concrete Drainage Channels and Grates

Fencing, locks on access manholes, and other necessary precautions shall be provided to prevent trespassing, vandalism, and sabotage.

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

ROOF DRAINS TABLE OF CONTENTS

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

PRODUCT FLYERS PENSTOCKS I STOPBOARDS I BULKHEADS I FLOODGATES

Container Irrigation Systems

Siphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs

ENGINEERED SOLUTIONS. Terre Arch Concrete Detention/Infiltration. Solutions Guide

Tank Modifications & Accessories

ENGINEERED SOLUTIONS. low impact development application guide

Stormwater collection products for all NZ stormwater specifications

ACO Building Drainage

A SunCam online continuing education course. Design of Drywells. David E. Fantina, PE

How to carry out a percolation test

Trade Waste Arresters

/ /

Multiline. ACO SYSTEMS and SOLUTIONS Pvt. Ltd. Polymer Concrete Drain System. Your Partner in Water Management Solutions

Waterplex. Creative Rainwater Solutions 0800 RAINSAC ( )

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

CONSTRUCTION OF ELEVATED WATER TANK & WATER WELL VAULT INTERNATIONAL CAMPUS AUGUST 2018

Light Duty Ramps. Loadingdocksupply.com PHONE:

ACO Self. Residential Drainage & Landscape Products. Product Line Overview Introduction to the Self line

A101 S001 1 SUB-BASEMENT 3/16" = 1'-0" SHEET (906) PH (906) FX 2 S101 NEW CONCRETE WALLS TO FORM WAVE TANK 3' - 0" 5' - 5"

BRUTALLY STRONG AS A RHINO SHOULD BE

Retaining Wall System

This consumes a high amount of space, and exacerbates the susceptibility of fully ventilated stacks to rapid pressure changes.

STORMWATER MANAGEMENT

A Forterra Company UrbanPond

SECURE & STYLISH FENCING, WE'LL BRING THE GOOD NEIGHBOUR DESIGN GUIDE: GOOD NEIGHBOUR FENCING

product guide USA EDITION NOVEMBER 2015

ACO Building Drainage Products

MACHINERY GUARDING SECTION

INFORMATION KIT 2018 COPYRIGHT 2018 PENTABLOCK WORLWIDE PTY LTD

16. Design of Pipeline Structures.

PHASE 1 Foundation & Drainage New Construction Phased Inspection Report John & Mary Doe 5237 Clinton Street, Denver, CO 80238

Environmental. Entec Biotec. Minitec, P6, P12, P18 & P25 Sewage Treatment Plants. Sustainable, Reliable, Affordable

WHY NOT Install a Rainwater Tank step by step guide to assist you

AS/NZS :2003. Plumbing and drainage AS/NZS :2003. Australian/New Zealand Standard. Part 3: Stormwater drainage

INSTALLATION GUIDE. Model #PP2 Pumpout Port Kit For Use with Grease Interceptors Models GB-50, GB-75 and GB-250. Contents

SXVS HEAVY DUTY SUMP PUMPS

Let us help! Free professional site visit with friendly support and advice. to make the right decision or call

PERMECAPTURE DETENTION / RETENTION. The Smart Stormwater Management Solution. S ustainable B y D esign

Product Catalogue 2014

ESS EcoCell Ecological Tank Systems

/ /

BGZ-S Heavy-duty channel

This unofficial translation of. Ministerial Decision No 421/1998. was downloaded from METS is not the copyright owner.

Defence ] Defence 9/14 A DIVISION OF STRONGFORM GROUP

Drilling a tube-well inside a wide-diameter well (preliminary trials)

WATER STORAGE SOLUTIONS Installation Guide - September 2017

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

COLLECTION AND DISTRIBUTION OF WATER

Rainwater Harvesting 2018

RIVE STOP PATENTED ELASTIC RIVET. Big expertise. Real convenience. Concrete commitment.

Transcription:

On Site Detention System. Setting new standards. NOTE: This OSD (On site detention system) brief should be read in conjunction with the Landscape Tanks brochure, which outlines all the features and benefits of the Landscape Tanks product. These features have been taken into the design of this OSD system, which we believe delivers a very practical, sustainable and highly cost effective OSD system. The Landscape Tanks are designed to last a lifetime and come pre-engineered for use as structural retaining walls, front fences, pool and pergola surrounds, water features, raised garden beds and much more all incorporating your new OSD system in the structure. Commercial and domestic. DWG format files on web site for downloading. All in one system * OSD System * Retaining wall,* Front fence, * Water tank * Raised garden bed * Water feature. Landscape Tanks Pty. Ltd abn 39133572111 Copyright 2017 Administration 2 Turner Court Wodonga Vic 3690 T: (02) 60566422 Www.landscapetanks.com.au Sales enquiries. Australia wide. Sydney/Brisbane 0407 200497 Melbourne/Adelaide 0414 308123 Email. Enquiries@landscapetanks.com.au Patent apn 2008202061, 2009904149, 2015202131, 2015100557, 2017200217, 2017901316 - Patents granted 2012100331, 2010286347 1

Imagine having your OSD system as your retaining wall or front fence. Sounds impossible doesn't it, well it s not and lots of people are using them already. In fact, if you plan your build correctly you may not need a traditional costly OSD system at all. Changing the way you think about O.S.D. * Stunning * Australia wide * Easy installation * Endless capacity * 50mpa concrete * No footings required * Three sizes available. * Domestic and commercial * Inbuilt HED unit with trash pit. The Landscape Tanks quality OSD system features a HED (High Early Discharge) tank, which incorporates a trash /silt pit and is usually located on the end of the line of tanks (centre options are available). Great savings can be made. Tanks are joined using cast in place O ring seals for endless storage capacity. Consider: Easy installation - no footings required. High grade pre cast concrete - to last a lifetime. HED unit with inbuilt trash/silt pit and mesh filter. Modular for endless storage capacity. Planter box on top to grow plants or shrubs. Above or below ground application. Easy fit cast in interconnecting O ring seals. Retaining wall, front fence or around pool. Three sizes available. Pre engineered drawings for big savings. Download DWG drawings on web site. HED pit may be located anywhere in the line of tanks end or side HED tank with inbuilt trash/silt pit (shown) and pit cover - mesh filter concrete baffle between trash pit and storage unit. Copyright 2017 2

Units may function as a water tank, OSD system and retaining wall or front fence. The Landscape Tanks are joined together using rubber "O" ring seals for endless storage capacity. Simply insert 50mm pressure pipe into the seals between tanks during installation. No other plumbing works required to join tanks together. The Landscape Tanks OSD system may eliminate the need for a traditional underground OSD system for huge savings. No footings required making them fast and easy to install. HED trash/silt pit unit All in one system * Retaining wall * Front fences,* OSD system, * Water tank * Raised garden bed * Water feature. 3

Configuring tanks and options. The Landscape Tanks are incredibly versatile and there are many and varied ways of configuring the Landscape Tanks to suit your project. The options offer endless water storage capacity. Place the HED unit (incorporating a pit and mesh filter) anywhere in the system to suit. Handy, lockable, easy access cover is standard with all HED units. Lockage durable top Planter top Trash/silt pit Mesh filter 100mm inlet - many options available Trash/silt pit may also make up the first or second tank in the row. - endless options. Reservoir units. Couple together for endless storage capacity. HED tank with trash/silt pit Discharge orifice 4

HED tank and trash pit configurations. RH3030 mesh OSD reservoir 100mm inflow into trash/silt pit. Slow release orifice. Common pipe sizes and location options available - see part numbers sheet. Open slot to receive water from hard surface into trash/silt pit Pit access cover Slow release orifice to suit. Centre trash/silt pit. OSD system centre inflow dual mesh screens Common pipe sizes and location options available - see part numbers sheet. 5

Design options water tanks and OSD system combined The Landscape Tanks may be used as water tanks and OSD system combined,while at the same time also acting as a structural retaining wall, front fence or around your pergola or swimming pool. This design option should deliver a massive saving as a traditional OSD system may not even be required. Tanks may also be buried to a height that suits or partially buried at one end. The OSD system may receive water either from the roof or from run off water from hard surfaces. Ideal for sloping ground may be staggered as required. Inflow and overflow in same tank The OSD system may receive water either from the roof or from run off water from hard surfaces. The water tank element of the structure is to receive water from the roof only. Tanks in the retaining wall are not joined together where the two systems meet. Both systems form an integral part of the structural retaining wall. Retaining wall/water tank/osd system combined. Water tanks Retained soil OSD System 6

Design options cont: The below configuration is somewhat similar to the centre HED tank configuration (above) in that hard surface run off water can be directed straight into the end of the line of tanks and into the HED tank with trash/silt pit. This can be particularly handy in some installations where remote pits and other plumbing are cumbersome and hard to manage. The Landscape Tanks are not designed to be driven on or carry heavy loads. It is recommended to have the planter box above ground if possible as that delivers a lovely end result. The raised garden bed is suitable for growing all types of plants. End HED tank receiving direct run off from driveway. Structural retaining wall and OSD system. Seals: (EPDM rubber) The Landscape Tanks use their own patented highly effective O ring seal to join the tanks together. This results in virtually no plumbing works required to join together. The seals are cast in during manufacture and enable the pipes to be inserted from either direction. They are flexible and provide a water tight seal. These proven seals are used wherever an orifice is required anywhere in our tanks. Seals can be expected to last a lifetime as they are not used in hostile environment. 7

The Landscape Tanks OSD system in more detail. With some planning and smart design you may not need a traditional OSD system at all. (Massive savings can be expected). During your build or renovation you can easily incorporate your OSD system into your design for use as structural retaining walls, front fences, raised garden bed or even around your pool for great results. This means you may not even need a traditional OSD system at all because you have the system as your retaining wall. This can result in quite substantial savings. The Landscape Tanks OSD system is fundamentally the same unit as the standard Landscape Tank, (please see standard Landscape Tanks brochure and web site for details) but with some clever design modifications they also make great OSD systems. a The purpose of an OSD system is to simply store stormwater on site during a heavy rain event and then release that water to the stormwater LPD (Legal point of discharge) at a suitable flow rate (slowly) to avoid flooding council and Water Board infrastructure. An OSD system will be designed by your hydraulics engineer (you will need to employ a hydraulics or civil engineer for this project) with a HED (High early discharge) unit incorporated into the system. This document is designed to assist you and your engineer understand the working of the Landscape Tanks and the OSD system, and just how easy they are to use. Councils and Water Boards Australia wide have variances depending upon local conditions, age of infrastructure and local environmental considerations. This will effect how many tanks you may need in the system. These Landscape Tanks are suitable for both domestic and commercial applications. 8

The HED tank. The purpose of the HED unit is to allow the engineer to accurately calculate the slow release orifice size (installed on the inside of the tanks during manufacture) and subsequent flow rate required for your system. The stormwater is directed to the HED unit first, which is an independent unit from the other tanks and fills first. The stormwater is directed into this reservoir via the trash/silt pit via stormwater hard surface run off, from the roof via downpipes or both. The HED unit (the first chamber) will form part of the overall storage reservoir and is integral to the overall system. The inbuilt convenient trash/silt pit is a unique feature of the Landscape Tank system which will make designing your system considerably easier. The Trash/silt pit has a RH3030 removable galvanised mesh filter to filter out course debris and other items which may find their way into your system over time. The water passes through the trash/ silt pit before entering the first tank reservoir in the system. The first tank or reservoir acts differently to the other storage reservoirs as explained on the next page. In the Landscape Tanks system, there are two options for the HED tanks as shown below. Slow release Slow release This unit has the option of a 100mm inlet pipe direct from the grate system on the property. This unit has the option of a rectangular opening (75mm x 600mm to receive run off water direct from the surface as required.. The HED tanks have an orifice plate fitted on the inside of the tank during manufacture. This plate is to suit your engineers design specifications. The Orifice plate specification will be advised to Landscape Tanks for inclusion in the system. The orifice plate is to be made of stainless steel 3mm thick. See page 10. 9

Overflow from HED into reservoir. (other tanks in the line). 90mm check valve to ensure water from HED is always full. When full water overflows through 100mm pipe at the top of into the other reservoir tanks. When HED Step irons medium and large units only. One way check Valve tanks water level drops (because it has been discharging through the slow release orifice), water from reservoir (other tanks in the line) flows back into the HED tanks and subsequently to storm water. Removable RH 3030 removable galvanised mesh. The HED unit fills completely first and then overflows into the following tanks via a 100mm pipe at the top of the tank once full. The storage reservoir capacity (number of tanks) is also calculated by your hydraulics engineer. There is a 90mm connecting pipe (O ring seal) connected between the HED tank and the following tanks. This 90mm connecting pipe has a check valve fitted to prevent the inflowing water in the HED tank from entering into the following tanks from the bottom orifice. The HED tank must be full for it to overflow into the following tanks. Water flow filling Water flow emptying The HED tank also has a slow release orifice plate fitted internally to your requirements. Once the storm has passed the HED tank will release water through the control orifice and water levels will begin to fall. As the water levels falls, water from the following tanks will flow back into the HED and out to stormwater. In another great innovation the orifice plate as specified by your hydraulics engineer is fitted by Landscape Tanks to O ring seal internal face. This design means that a plumber can use standard PVC pipe sizes and simply push into the rubber O ring seal for convenience provided of course this PVC piping is larger than the orifice plate opening. Internal face of the tanks showing orifice plate. External tank face of the tank with PVC pipe 10

Centre HED tanks and Trash/silt pit. HED tank/trash silt pit includes: Galvanised 3mm mild steel access top, 3mm stainless steel orifice plate fitted internally. Orifice plate secured with SS Dyna bolts Removable galvanised RH3030 mesh, Orifice hole fitted where required, internal non return valve for equalising port. Internal concrete baffles. Step irons as required. The third option for the HED tanks and trash/ silt pit tank is that the tank may be placed in the middle of a row of tanks for convenience. This means you may be able to direct the driveway stormwater flow into the centre of the row of tanks on the lower side of the driveway. With some careful planning of heights and slopes this feature can save a great deal of money. Technical specifications: Full set of DWG downloadable files is available for downloading of our web site. Www.landscapetanks.com.au (go to the builders and architects box) All tanks measure 2800mm long and 1100mm wide. Capacity (including trash pit and HED tank) HED tank/trash pit mesh Small tank 1,750 litres RH 3030 galvanised Medium unit 2,250 litres Large unit 3,150 litres Weight (including planter top) Checker plate trash pit top. Small unit 2.5tonnes 1,055mm high Galvanised mild steel 3mm Medium unit 2,250 tonnes 1,300mm high Large unit 4,00 tonnes 1,600mm high Concrete (Standard any strength available) Delivery times High grade concrete (50mpa after 28 days). Please allow three weeks from order Lifting (4 Swift anchor points per tank) Pipe plumbing sizes Small tank 1.3 tonnes Standard 90mm Medium tank 1.3 tonnes Optional 100mm Large tank 2.5 tonnes. Equalising ports 50mm standard. Planter tops (both sizes) 1.3 tonnes. Equalising ports 90mm optional. More detail on physical sizing please see pages 11 to 13. (Larger planter top upgrade adds 100mm to heights) Custom design configurations available subject to discussions with Landscape Tanks staff. Specifications in this document are subject to change without notice. Copyright 2017 11

HED tank - Trash/Silt pit includes: Galvanised 3mm mild steel access top, bolt to secure. 3mm stainless steel orifice plate fitted internally. Orifice plate secured with SS Dyna bolts Removable galvanised RH3030 mesh, Orifice hole fitted where required, internal non return valve for equalising port. Internal concrete baffles. Step irons as required. 100mm sump for silt collection Tank part numbers and dimensions 12

13

14

15

16

17

Commercial and custom applications. The Landscape Tanks and their planter tops are versatile and may be designed to suit any project. Access to tanks below may be through entire planter top area. Ideal for aquatic purposes or oil separation or waste water treatment or the like. Please contact Landscape Tanks staff to discus options in this regard. Something different. Imagine having you OSD system /Water tank as part of your Poll Surround or pergola. Its all possible and adds that WOW factor to your property. Tanks may also be used to store pumps and other items. 18