Suspended Metal lath and Cement Plaster. Coverings Rigid Insulation, 1/2 - in 0.75 psf. Floor Fill Lightweight Concrete, per inch 8 psf

Similar documents
(b) Calculate the required nominal axial compression strength, Pn of the column.

Loads and Load Paths. "Architecture is inhabited sculpture." -Constantin Brancusi

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

Pre-schematic Considerations. Who. What. Where

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

Technical Assignment 3 December 3, 2007

STRUCTURAL TECHNICAL REPORT 1

OVERALL STRUCTURAL SYSTEM

Table of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5

Building Division Informational Handout

Tutorial 1. Ch 1: Types of Structures and Loads Ch 2: Analysis of Statically Determinate Structures Ch 3: Analysis of Statically Determinate Trusses

1000 CONTINENTAL SQUARE

Technical Report #1. Indiana Regional Medical Center Indiana, PA. Cody A. Scheller. Structural Concepts & Existing Conditions Report

Dead Loads (psf): Concrete Floor Slab on Metal Deck 45 psf Mechanical and Ceiling 7 psf Miscellaneous 5 psf Exterior Wall 80 psf

Third Avenue New York, NY. Structural Concepts/ Structural Existing Conditions Report September 30, Michelle L.

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

Structural Technical Report 1 Structural Concepts / Existing Conditions

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

Simplified Building Schematic for Typical Floor (Levels 9 through 22):

90% Design Submittal Structural Calculations Parking Garage CDRL

John Jay College Expansion Project

Structural Redesign Gravity System

HIGH RISE CONDO SOHO, NEW YORK, NY

Technical Report #2. Matthew R Peyton

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Project. San Jose City College Physical Education Building. Prepared For. Prepared By PLACE IMAGE HERE. Ken Bauer, AIA Principal

Case Study in Steel adapted from Structural Design Guide, Hoffman, Gouwens, Gustafson & Rice., 2 nd ed.

STEEL STRUCTURAL SYSTEMS

[TECHNICAL REPORT 3] Lateral System Analysis

Kaleida Health Global Heart and Vascular Institute University at Buffalo CTRC/Incubator. Buffalo, New York. Technical Report #2

Marconi Communications Building #5 Warrendale, Pennsylvania

VARIOUS TYPES OF SLABS

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

Technical Report 1. Kingstowne Section 36A 5680 King Center Drive Kingstowne, VA James Chavanic. Structural Option. Advisor: Dr.

Technical Report 1. Seneca Allegany Casino Hotel Addition. Salamanca, NY

Simplified Building Schematic for Typical Floor (Levels 9 through 22):

Boyds Bear Country Pigeon Forge, TN

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Lateral System Analysis and Confirmation Design November 15, 2004

David A. Walenga Technical Assignment #1

Corporate Headquarters

Dead Load Weight of Roof Trusses. Dead Load Weight of Floor Trusses

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Technical Report #3. Matthew R Peyton

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

111 MORGAN ST. Ryan Friis

Temecula Medical Center Temecula, CA

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

Jonathan R. Torch Technical Report 2 Columbia University. Technical Report 2. Pro-Con Structural Study of Alternate Floor Systems

Stone and Masonry Veneer

Technical Report #3: Lateral System Analysis. Executive Summary

Technical Report 1 Bed Tower Addition at Appleton Medical Center Appleton, WI

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

Earth and Engineering Sciences Building University Park, Pennsylvania

POST AND FRAME STRUCTURES (Pole Barns)

Technical Report #1. Matthew R Peyton

STRUCTURAL DESIGN CRITERIA

Structural Inspection

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

GEN*NY*SIS CENTER FOR EXCELLENCE IN CANCER GENOMICS Rensselaer, NY

THE FORENSIC MEDICAL CENTER

Masonry and Cold-Formed Steel Requirements

Structural Technical Report #1 By Robert Whitaker

THE CITY OF WALTHAM MASSACHUSETTS PURCHASING DEPARTMENT PHASE III RENOVATIONS TO THE FORMER BANKS SCHOOL ELDERLY HOUSING CONDOMINIUMS AND CONDOMINIUMS

John Jay College Expansion Project

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

POST AND FRAME STRUCTURES (Pole Barns)

Point Pleasant Apartments Point Pleasant, NJ Ryan P. Flynn Structural Option Faculty Consultant: Dr. Hanagan

Executive Summary...2 Introduction...3 Structural System Overview Buffalo,...4 Foundation...4 Floor System...4 Gravity System...4 Lateral System...

Fundamentals of Building Construction: Materials and Methods

Executive Summary Building Description: Introduction... 13

G.Muttrah Commercial & Residential Complex Muscat, Sultanate of Oman

UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014. A How To guide for use of the new provisions

Hilton Baltimore Convention Center Hotel Western Podium

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Structural Technical Report #2 By Robert Whitaker

This report investigates alternative floor systems for the building. A brief summary of each system is as follows:

La Jolla Commons Office Tower. Appendix Slides. Architecture Breadth. Dual Systems Check. Lateral System. Shear Wall Modeling. Verification.

2003 International Residential Building Code

TECHNICAL REPORT II STRUCTURAL STUDY OF ALTERNATE FLOOR SYSTEMS

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

American Eagle Outfitters: Quantum III Pittsburgh, PA October 5, Samuel M. P. Jannotti Structural Professor M. Kevin Parfitt Technical Report I

Rutgers University Law School Building Addition and Renovation Camden, NJ

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

LPI 56 Technical Guide

Structural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report

ADVANCED FRAMING LUMBER

Framing Methods Structural Components

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

STANDARD PLAN RELEASE SUMMARY(SPR) Facilities Management Department

'Rose Avenue Project'

2003 International Building Code Errata

CARBON MONOXIDE ALARMS

Butler Health System New Inpatient Tower Addition/Remodel. Dr. Ali Memari Technical Report #1. Architects Rendering. Technical Report #1

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

Transcription:

Dead Loads Ceiling Suspended Metal lath and Cement Plaster 15 psf Coverings Rigid Insulation, 1/2 - in 0.75 psf Floor Fill Lightweight Concrete, per inch 8 psf Floor Finish Frame Partitions Ceramic or quarry tile (3/4) in. on (1/2) Mortar bed Wood Studs 2 x 4, plaster two sides 20 psf 20 psf Outer Walls Masonary, Lightweight Concrete 105 pcf *Floor Slabs *Girders *Columns Normal Weight Concrete 150 pcf Slab Thickness 4 in Slab Load 50 psf Normal Weight Concrete 150 pcf Cross Sectional Area 24 X 18 in^2 Girder Load 450 lb/ft Normal Weight Concrete 150 pcf Cross Sectional Area 24 X 24 in^2 Column Load 600 lb/ft * Exact dimensions are not designed therefore dimensions are assumed.

Roof Dead Loads: Section 1 & 2 Ceiling Suspended Metal lath and Cement Plaster 15 psf Coverings Rigid Insulation, 1/2 - in 0.75 psf *Floor Slabs *Girders Normal Weight Concrete 150 pcf Slab Thickness 4 in Slab Load 50 psf Normal Weight Concrete 150 pcf Cross Sectional Area 24 X 18 in^2 Girder Load 450 lb/ft ** Does not include Girder weight **Dead Load, D 65.75 psf Tributary Width of Interior Girders = 25 ft Span = 25 ft Area = 625 ft^2 Wu = Uniform Dead Roof Load for Interior Girders = 2093.75 lb/ft Wu = Tributary Width for Exterior Girders 12.5 Span = 25 ft Area = 312.5 ft^2 Uniform Dead Roof Load for Exterior Girders = 1271.875 lb/ft

Floor Dead Loads Ceiling Suspended Metal lath and Cement Plaster 15 psf Coverings Rigid Insulation, 1/2 - in 0.75 psf Floor Fill Lightweight Concrete, per inch 8 psf Floor Finish Ceramic or quarry tile (3/4) in. on (1/2) Mortar bed 20 psf Frame Partitions Wood Studs 2 x 4, plaster two sides 20 psf Outer Walls Masonary, Lightweight Concrete 48 psf *Floor Slabs *Girders *Columns Normal Weight Concrete 150 pcf Slab Thickness 4 in Slab Load 50 psf Normal Weight Concrete 150 pcf Cross Sectional Area 24 X 18 in^2 Girder Load 450 lb/ft Normal Weight Concrete 150 pcf Cross Sectional Area 24 X 24 in^2 Column Load 600 lb/ft **Total Floor Dead Load = 161.75 psf ** Does not include Girder and Column weight Tributary Width of Interior Girders 25 ft Span = 25 ft Tributary Area = 625 ft^2 Wd = Uniform Dead Floor Load for Interior Girders = 4493.75 lb/ft Tributary Width for Exterior Girders = 12.5 ft Span = 25 ft Area = 312.5 ft^2 WD = Uniform Dead Floor Load for Exterior Girders = 2471.875 lb/ft

Live Loads: Section1 & 2 Occupancy: Business Group G Use Uniform (psf) Concentrated (lbs) Lobbies 100 - Movable Seats 100 - First Floor Corridor 100 - Elevator Machine on area of 2in X 2in - 300 Corridors above first floor 80 2,000 Offices 50 2,000 Classrooms 40 1,000 Stairs and exits 100 - Walkways 60 - * Values apply to different parts of building, worst case scenario will be applied when doing the load 1ST FLOOR: = Unreduced Live Load = 100 psf = live load element factor = 2 = Tributary Area = 625 ft^2 L = 67.42640687 psf 2nd to 5th Floor: = Unreduced Live Load = 100 psf = live load element factor = 2 = Tributary Area = 625 ft^2 L = = 67.42640687 psf

Roof Live Loads: Section 1&2 Occupancy: Business Group G Use Uniform (psf) Concentrated (lbs) Elevator Machine on area of 2in X 2in - 300 Roof 20 - = Minimum Uniform Live Load = 20 psf = Tributary Area = 625 ft^2 = Reduction Factor = 0.6 F = Inches of rise per foot for a sloped roof = 0 in/ft = Reduction Factor = 1 =.Reduced Roof Live Load = 12 psf Check for min. 12 psf WLR = WLR = Tributary Width Interior Girders = Tributary Width Exterior Girders = Uniform Roof Live Load for Interior Girders = Uniform Roof Live Load for Exterior Girders = 25 ft 12.5 ft 300 lb/ft 150 lb/ft * Values apply to different parts of building, worst case scenario will be applied when doing the load

Atrium Live Loads Use Uniform (psf) Concentrated (lbs) Elevator Machine on area of 2in X 2in - 300 Walkways 60 -

Flood Loads According to FEMA Flood Map the area of 78249 is under Zone X: Areas determined to be outside the 0.2 % annual chance floodplain. Based on the lack of risk, the flood loads are not necessary for this structure.

Snow Loads: Section 1 & 2 Snow load on flat roof 3.15 psf Exposure Factor 0.9 Thermal Factor 1 Importance Factor 1 * Category II Ground snow load 5 psf Minimum roof snow load for low-slope roof 5 psf S Snow Load 5 psf Tributary Width Interior Girders = Tributary Width Exterior Girders = 25 ft 12.5 ft Ws = Uniform Roof Live Load for Interior Girders = 125 lb/ft Ws = Uniform Roof Live Load for Exterior Girders = 62.5 lb/ft

Snow Loads: Atrium Slope Factor Roof Slope Snow Load on Flat Roof Sloped Roof Snow Load Therman Factor ps = Cs * pf = S = Snow Load = 0.6 30 5 psf 3 psf 1 3 psf 5 psf

Rain Loads i Design Rainfall Intensity 4.25 (in./h) A1 Roof Area 1 20000 ft^2 A2 Roof Area 2 5000 ft^2 Q1 Flow Rate 1 884 gal/min Q2 Flow Rate 2 221 gal/min Hydraulic Head 1 4.07 in Hydraulic Head 2 2.19 in Static Head 1 2 in Static Head 2 2 in R1 Rain Load on Roof Area 1 31.564 psf R2 Rain Load on Roof Area 2 21.788 psf Roof Area 1 used a 8in diameter drain. Roof Area 2 used an 6in diameter drain. Tributary Width Interior Girders = Tributary Width Exterior Girders = 25 ft 12.5 ft WR1 = WR1 = Uniform Rain Load for Interior Girders = Uniform Rain Load for Exterior Girders 789.1 lb/ft 394.55 lb/ft WR2 = WR2 = Uniform Rain Load for Interior Girders = Uniform Rain Load for Exterior Girders 544.7 lb/ft 272.35 lb/ft

Flat Roof 1 Parameters: Factors: 1st Floor Height 16 ft Wind Speed, V 120 mph 2nd Floor Height 12 ft Directionality Factor, kd 0.85 3rd Floor Height 12 ft TopographicFactor, Kzt 1 4th Floor Height 12 ft mean height, h 67.61 ft 5th Floor Height 12 ft Wind Loads - Walls, ph 50.87 psf Angle of Roof, θ 30 Wind Pressure at Roof: Risk Category III Zone 1 0 psf Structure Type Building Zone 2 0 psf Surface Roughness B Zone 3-40.1 psf Exposure Category C Zone 4-35.8 psf Class Building 2 Zone 5-29.3 psf Enclosure classification Enclosed Length parallel to wind, L 50 ft Length perpendicular to wind, B 100 ft

Flat Roof 1 Wind 2 Parameters: Factors: 1st Floor Height 16 ft Wind Speed, V 120 mph 2nd Floor Height 12 ft Directionality Factor, kd 0.85 3rd Floor Height 12 ft TopographicFactor, Kzt 1 4th Floor Height 12 ft mean height, h 67.61 ft 5th Floor Height 12 ft Wind Loads - Walls, ph 50.87 psf Angle of Roof, θ 30 Wind Pressure at Roof: Risk Category III Zone 1 0 psf Structure Type Building Zone 2 0 psf Surface Roughness B Zone 3-40.1 psf Exposure Category C Zone 4-35.8 psf Class Building 2 Zone 5-29.3 psf Enclosure classification Enclosed Length parallel to wind, L 100 ft Length perpendicular to wind, B 50 ft

Atrium 2 Parameters: Factors: 1st Floor Height 16 ft Wind Speed, V 120 mph 2nd Floor Height 12 ft Directionality Factor, kd 0.85 3rd Floor Height 12 ft TopographicFactor, Kzt 1 4th Floor Height 12 ft mean height, h 67.61 ft 5th Floor Height 12 ft Wind Loads - Walls, ph 0 psf Angle of Roof, θ 30 Wind Pressure at Roof: - Risk Category III Zone 1-19.2 psf Structure Type Building Zone 2-24.6 psf Surface Roughness B Zone 3-37.8 psf Exposure Category C Zone 4-33.7 psf Class Building 2 Zone 5-27.6 psf Enclosure classification Enclosed Length parallel to wind, L 50 ft Length perpendicular to wind, B 100 ft

Atrium 2 Parameters: Factors: 1st Floor Height 16 ft Wind Speed, V 120 mph 2nd Floor Height 12 ft Directionality Factor, kd 0.85 3rd Floor Height 12 ft TopographicFactor, Kzt 1 4th Floor Height 12 ft mean height, h 67.61 ft 5th Floor Height 12 ft Wind Loads - Walls, ph 50.87 psf Angle of Roof, θ 30 Wind Pressure at Roof: - Risk Category III Zone 1-19.2 psf Structure Type Building Zone 2-24.6 psf Surface Roughness B Zone 3-37.8 psf Exposure Category C Zone 4-33.7 psf Class Building 2 Zone 5-27.6 psf Enclosure classification Enclosed Length parallel to wind, L 100 ft Length perpendicular to wind, B 50 ft

Flat Roof 2 Parameters: Factors: 1st Floor Height 16 ft Wind Speed, V 120 mph 2nd Floor Height 12 ft Directionality Factor, kd 0.85 3rd Floor Height 12 ft TopographicFactor, Kzt 1 4th Floor Height 12 ft mean height, h 67.61 ft 5th Floor Height 12 ft Wind Loads - Walls, ph 0 psf Angle of Roof, θ 30 Wind Pressure at Roof: - Risk Category III Zone 1 0 psf Structure Type Building Zone 2 0 psf Surface Roughness B Zone 3-37.8 psf Exposure Category C Zone 4-33.7 psf Class Building 2 Zone 5-27.6 psf Enclosure classification Enclosed Length parallel to wind, L 200 ft Length perpendicular to wind, B 100 ft

Flat Roof 2 Parameters: Factors: 1st Floor Height 16 ft Wind Speed, V 120 mph 2nd Floor Height 12 ft Directionality Factor, kd 0.85 3rd Floor Height 12 ft TopographicFactor, Kzt 1 4th Floor Height 12 ft mean height, h 67.61 ft 5th Floor Height 12 ft Wind Loads - Walls, ph 50.9 psf Angle of Roof, θ 30 Wind Pressure at Roof: - Risk Category III Zone 1 0 psf Structure Type Building Zone 2 0 psf Surface Roughness B Zone 3-37.8 psf Exposure Category C Zone 4-33.7 psf Class Building 2 Zone 5-27.6 psf Enclosure classification Enclosed Length parallel to wind, L 100 ft Length perpendicular to wind, B 200 ft