STRUCTURAL ANALYSIS OF A 100 KW WIND TURBINE TOWER

Similar documents
SET PROJECT STRUCTURAL ANALYSIS OF A TROUGH MODULE STRUCTURE, IN OPERATION AND EMERGENCY Luca Massidda

Design of large scale wind turbine towers in seismic areas

A STUDY ON THE BEHAVIOR OF CONCRETE WIND POWER TOWER

Keywords: steel structures, cold-formed steel angles, structural stability, numerical analysis, non-linear analysis.

BUCKLING ANALYSIS OF PULTRUDED GFRP HOLLOW BOX BEAM

SEISMIC BEHAVIOUR OF RING SHAPED STEEL PLATE SHEAR WALL

RFS-CT HISTWIN High-Strength Steel Tower for Wind Turbine

Experimental and numerical validation of the technical solution of a brace with pinned connections for seismic-resistant multi-story structures

Fundamental Course in Mechanical Processing of Materials. Exercises

The Effect of Axial Force on the Behavior of Flush End-Plate Moment Connections

COLLAPSE OF A STEEL STRUCTURE AS A RESULT OF LOCAL BUCKLING

REAL SCALE EXPERIMENTAL ANALYSES OF CIRCULAR HOLLOW SECTION MULTI-PLANAR STEEL TRUSSES

Summary. 1. Introduction. Enrique GONZÁLEZ DUEÑAS Civil Engineer LRA Infrastructures Consulting Madrid, SPAIN

Finite element analysis of double layer metal bellows flexible hose for chemical pipeline Weijie Du, He-hui Wang 1,b), Shidong Wen 1,c) 1

RFS-CT HISTWIN High-Strength Steel Tower for Wind Turbine

Structural Design and Analysis of Wind Turbine Blade with Skin-Spar-Sandwich Composite Structure

FULL SCALE TESTS ON BOLTED BEAM-TO-BEAM END-PLATE

THE STUDY OF THE OVER STRENGTH FACTOR OF STEEL PLATE SHEAR WALLS BY FINITE ELEMENT METHOD

STAAD.pro 2007 Design of Wind Turbine Foundations

ON THE ANALYSIS OF A COLD FORMED STEEL PROFILE ARCH STRUCTURE

Numerical analysis of truss systems with stiffened flattened end bars

CHAPTER 3 ANALYSIS METHOD

A SEMI-RIGOROUS APPROACH FOR INTERACTION BETWEEN LOCAL AND GLOBAL BUCKLING IN STEEL STRUCTURES

FINITE ELEMENT MODELING OF ANGLE BRACING MEMBER BEHAVIOR IN EXPERIMENTALLY TESTED SUB-FRAME SPECIMENS

Design and Finite Element Analysis of A Spatial Tubular Truss and Its Pin Support

Chapter 7. Finite Elements Model and Results

INFLUENCE OF MEMBER COMPONENTS ON THE STRCUTURAL PERFORMANCE OF BEAM-TO-COLUMN JOINTS OF PITCHED ROOF PORTAL FRAMES WITH CLASS 3 AND 4 SECTIONS

Analysis and experimental studies of building glass facade

The Local Web Buckling Strength of Stiffened Coped Steel I-Beams

D. Y. Abebe 1, J. W. Kim 2, and J. H. Choi 3

POST BUCKLING BEHAVIOR OF THIN WALLED SILO STRUCTURE.

CHAPTER 4 CORRELATION OF FINITE ELEMENT RESULTS WITH EXPERIMENTAL VALUES OBTAINED FROM THE SAC STEEL PROJECT SPECIMENS 4.

Modal-spectral analysis of a gas storage tank.

7 LOCAL BUCKLING OF STEEL CLASS 4 SECTION BEAMS

Metal-plate connections loaded in combined bending and tension

LOW-CYCLE FATIGUE FAILURE MECHANISM OF WIND TURBINE FOUNDATION DUE TO VIBRATION OF UPPER STRUCTURE

THE STRUCTURAL ANALYSIS OF STEEL SILOS WITH CYLINDRICAL-WALL BEARING AND PROFILE-STEEL BEARING

midas Civil Cable Stayed Bridge Bridging Your Innovations to Realities

NON-LINEAR BEHAVIOR OF STEEL PLATE SHEAR WALL WITH LARGE RECTANGULAR OPENING

ELASTIC AND ELASTO-PLASTIC BUCKLING ANALYSIS OF PERFORATED STEEL PLATES

New approach to improving distortional strength of intermediate length thin-walled open section columns

Finite Element Analysis of Concrete Filled Steel Tube Flexural Model

Stability Analysis of Rigid Steel Frames With and Without Bracing Systems under the Effect of Seismic and Wind Loads

PLASTIC DESIGN OF STAINLESS STEEL STRUCTURES

BRACED FRAME USING ASYMMETRICAL FRICTION CONNECTIONS (AFC)

Abstract Introduction and Background Formulation Results and Discussion Conclusion and Future Work References...

Case Study: Challenges of a Single-layer Reticulated Dome

THE EFFECTS OF FRAME DEFORMATION ON WELDED GUSSET PLATES FOR DIAGONAL BRACING ELEMENTS LOADED IN TENSION

MODAL ANALYSIS OF A SMALL WIND TURBINE WITH WIND CONCENTRATOR

APPLYING MSC/PATRAN AND MSC/NASTRAN TO IMPROVE THE DESIGN PERFORMANCE OF LARGE BULK MATERIALS HANDLING MACHINES

Torsion in tridimensional composite truss bridge decks

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

ANALYTICAL AND EXPERIMENTAL STUDY ON COMPOSITE FRAMES

VIBRATION ANALYSIS OF AN OIL PRODUCTION PLATFORM

Design of Laterally Unrestrained Beams

FINITE ELEMENT ANALYSIS FOCUSED ON THE FLANGE PLATES AND CONNECTING BOLTS OF RUBER BEARINGS

A Commentary on Improving the Design Rules for Thin Aluminium Shell Structures

Verification Examples

Leelachai M, Benson S, Dow RS. Progressive Collapse of Intact and Damaged Stiffened Panels.

A Study on Design of A High Efficiency Vertical Axis Wind Turbine Blade Using Composite Materials

Zacq Consultants. An Overview

STRENGTH OF PLATES OF RECTANGULAR INDUSTRIAL DUCTS

Effect of Loading Level and Span Length on Critical Buckling Load

PARAMETRIC STUDY OF FLANGE JOINT AND WEIGHT OPTIMIZATION FOR SAFE DESIGN AND SEALABILITY- FEA APPROACH Chavan U. S.* Dharkunde R. B. Dr. Joshi S.V.

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Section Moment Capacity Tests of Rivet-Fastened Rectangular Hollow Flange Channel Beams

Influence of arch bridge skewness

Fully integrated simulation and design process for offshore wind turbines including support structures

Analysis of Bolted Beam-Column Connections with Multiple Bolts per Row and Column Web Stiffeners

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

1 Prepared By:Mr.A.Sathiyamoorthy, M.E., AP/Civil

POSTBUCKLING BEHAVIOUR OF A STIFFENED PANEL SUBJECT TO COMBINED LOADING

Modelling shearing characteristics of reinforced concrete

STRESS -STRAIN ANALYSIS AND EXPERIMENTAL VERIFICATION OF THREE-ROLL PYRAMIDAL SHAPE CONFIGURATION ROLL BENDING MACHINE

Footbridge 2005 Second International Conference

To have a clear idea about what really happened and to prevent the

Modal Behaviors of Spun-Cast Pre-Stressed Concrete Pole Structures

Code No: R Set No. 1

MODELING THE STRUCTURAL DYNAMICS OF CHOSEN COMPONENTS OF THE HORIZONTAL AXIS WIND TURBINE

DEVELOPMENT AND APPLICATION OF SYSTEM TO REDUCE THE EXCESSIVE TENSILE FORCES ARISING IN LAMINATED RUBBER BEARING

Pull-Through Failure Tests of Thin Steel Roof Battens under Wind Uplift Loads

Parametric Study of Concrete Filled Steel Tube Column

Fracture and springback on Double Bulge Tube Hydro-Forming

Experimental Tests and Numerical Modelling on Slender Steel Columns at High Temperatures

ST7008 PRESTRESSED CONCRETE

Multi storey buildings

Strength and Ductility of Steel Cold-Formed Section Beam to Column Bolted Connections

NUMERICAL ANALYSIS OF BUCKLING AND POST BUCKLING BEHAVIOR OF SINGLE HAT STIFFENED CFRP PANEL

Buckling Behaviour of Three-Dimensional Prestressed Stayed Columns

OPTIMIZATION OF STEEL CONNECTING ROD BY ALUMINUM CONNECTING ROD USING FINITE ELEMENT ANALYSIS

Jib Crane Analysis Using FEM

Belleville Spring. The relation between the load F and the axial deflection y of each disc. Maximum stress induced at the inner edge

BOUNDARY CONDITIONS OF SHEAR WALLS IN MULTI-STOREY MASONRY STRUCTURES UNDER HORIZONTAL LOADINGS

Example of a modelling review Roof truss

Finite Element Analysis of Failure Modes for Cellular Steel Beams

THIN WALLED COMPOSITE SHELLS UNDER AXIAL IMPULSIVE LOADING

BAS-010 B.TECH. (AEROSPACE ENGINEERING) LC) PROGRAMME (BTAE) BAS-010 : MACHINE DESIGN

RESILIENT INFRASTRUCTURE June 1 4, 2016

Optimization Design of Arm Frame of Folding Arm Type Tower Crane Based on ANSYS Ge-ning XU, Wen-ju LIU * and Yan-fei TAO

Transcription:

Copyright 2013 by ABCM STRUCTURAL ANALYSIS OF A 100 KW WIND TURBINE TOWER Mendes Fernandes, Télio Menezes, João Carlos ITA (Instituto Tecnológico de Aeronáutica), São José dos Campos - SP - Brasil teliofm@hotmail.com menezes@ita.br Abstract. Most large wind turbines currently installed use self-supporting steel tubular towers. The present study aims to perform a structural analysis of a 100 kw wind turbine tower, taking into consideration several structural criterions. Among many requirements of the design of a tower, the analysis of free vibration has been performed. Details of static and elastic stability analysis are also presented. The integrity analysis were performed using the commercial software ANSYS. The height of the tower was considered as 24 m. The tower has been designed as an assembly of four 6 m height modules connected by bolted joints. A special consideration of the module connections will be presented. Flanges are adopted to strengthen the tower modules end, having also the purpose of attaching the modules extremities by pre stressed bolts. Contact elements were adopted for the joint model. A distinct tool provided by ANSYS is the possibility of applying a preload to the connecting bolts. Under the condition of a load produced by the turbine blades thrust, the connected flanges tend to separate at the outer edge. One may obtain the state of deformation of the opened joint. Results of the stress analysis of the joints reveal a major stress concentration at the base of the bolts heads. Keywords: Wind Turbine; Finite Elements; Vibrations; Structural Analysis 1. INTRODUCTION This paper aims to contribute to the expansion of engineering studies in the area of alternative and renewable energy generation, specifically helping in the development of a methodology for the design of structures of tubular towers of wind generators. For a 24 meters height wind turbine of 100kW, all the dynamic and static requirements are defined for the design of the tubular tower, and a methodology using finite elements is set up. The design is based primarily on the vibration modes of the tower that should not coincide with the frequency of the generator excitation. Thereafter the basic geometry is defined. Thereon the static strength analysis and buckling is carried out, ending with the detailed analysis of the tower flanged pre stressed bolt joints modules, leading to the definitions of the amount of screws needed and the appropriate pretension load. Due to the complexity of the structures and the non-linearity of the contacts between the modules of the structure, the finite element method, using the commercial software ANSYS for nonlinear structural analyzes, and RADIOSS for the linear analysis. 2. REQUIREMENTS In the design of the tower, the critical gust load at the generator and the excitation frequencies of the rotation generator and crossing of blades were considered. For the sizing of the wind tower a wind generator of 100 kw having a height of 24m was considered according to Donadon et al (2008). The generator project had a preliminary evaluation of characteristics of the blades through an optimization software for blades of wind generators. The wind generator nacelle presents 4 tons, including the blades, the critical gust load for a wind speed of 30 m/s leading to a drag force was estimated to be 92kN, witch is a critical condition for static sizing of the tower. For the nominal wind velocity of 12.5 m/s the blades speed ratio at λ = 6.759, which corresponds to a rotation speed of 99 rpm, or an excitation frequency of 1.65 Hz. Attention should also be given to the fact that, for reasons of aerodynamic disturbance produced by the passage of a blade near the tower, a frequency of three times the excitation frequency rotation of the generator, 1.65 Hz, should also occur, i.e. 4.95 Hz. 3. BASIC CONCEPTION AND STRUCTURAL ANALYSIS Recently, Mendes and Menezes (2010a) presented a study of sensitivity to design parameters which identified the diameter of the base of the tower ideal for adjusting the natural frequency of the tower away from the frequencies of excitation of the generator. From this, all the basic conception was defined: base diameter of 3.0m, top diameter of 1.8m, four flanged modules of 6.0m height and wall thickness of 9.5mm that should be checked trough the static analysis. 9539

Télio Fernandes Mendes, João Carlos Menezes Structural Analysis of a 100 kw Wind Turbine Tower Figure 1 shows the first natural modes and frequencies of the wind tower designed. The first and second mode for this configuration are first order bending modes of 3.47Hz, which classifies the tower as flexible, placed between the blade passing frequency, 4.95Hz, and the rotational speed of the generator, 1.65Hz. The third and fourth modes are also bending, however, second-order modes of 20Hz, well away from the excitation frequencies of the wind generator. Figure 1. Eigenvector and eigenvalues of the tubular conical wind tower for modal analysis Figure 2 shows results for the global stress static analysis for the critical gust drag load condition of 92kN in addition with the gravitational load also applied to evaluate the effects of the weight of the turbine and tower together with the wind load. From the results it is seen that the gravitational loads are negligible compared to the gust load. It could be considered conservative to neglect it as it reduces the tensioning loads acting in the module flanges. The figure presents separate results for the gravitational load, gust load and both together. Figure 2. Global stress static analysis von Mises stress (MPa). Considering that, standard steel metallic plates have its yielding stress of almost 345 MPa, one may conclude that for static loads the structure has a high margin of safety. Structures of wind turbines should be designed to high cycling, higher than aeronautical structures e.g. Thereby, for the normal operating conditions, loads must be kept in low levels in order to avoid considering also the extreme amplifications dynamic loads in the count of the fatigue damage cycles. Figure 3 shows the result of the buckling analysis for the critical gust load. Similarly to the stress static analysis of the structure, the weight of the structure has low influence on the results. The structure provides security for this requirement as it would be required a load 24 times greater than that to produce structural instability in the tower. 9540

Figure 3. Buckling analysis 4. BOLTED JOINT For the flanged bolted joints a detailed analysis was performed to validate the methodology for the sizing of the joint: thickness, number of bolts and pre tension load. 4.1 Theoretical model The ESDU 84039 (1986) presents an analytical method for analysis of flanged connections with pre-tensioned bolts under tensile load for estimating the stresses, deformation and the maximum load allowable for the joint based on experimental data. According to the ESDU 85021 (1995), pre-tensioned bolted joints must ensure two conditions: the bolts do not yield and the flanged joint does not open. The procedure warns that this kind of analysis is a complex procedure resultant from the interaction of various elements stiffness. Thus, the procedure provides simplified models that illustrate the main effects of the many factors that influence the stresses and deflections in the joint. The German Procedure, VDI2230 (2003), presents some analytical methods to evaluate the behavior of this joint to some restricted situations. It presents a method for calculating the bolt load increase as a proportion of load increase in the width of the wall of influence under these conditions. The axial load on the flanged joint and the effect of the moment due to the eccentricity of loading are considered separately. The axial load is assumed to be shared between the screw and the pre-tensioned flange in proportion to the stiffness of the load paths, which, in the case of flanges, are based on an area of the reduced cross section related to the compressed volume by the pre load. This procedure presents the disadvantage of being too conservative for low values of loading. Schmidt and Neuper (1997) proposed a more sophisticated model identified as "Model C", a method that combines aspects of VDI2230 and considers the load on the screw so as to be as close as possible to the experimental results, which makes it a more realistic calculation, however increasing the complexity of calculating the loading. The uniformity of loading of the screw around the tower depends on the accuracy of the contact surfaces between the coupling flange. Schmidt et al (1999) investigated the effects of various imperfections using a finite element model and iterative testing done with the tolerance levels allowed. Shigley (1994) emphasizes one more point in the complexity of the analysis of this type of joint when it lists a table to some material friction coefficients. Figure 4 shows schematically the behavior of a pre-tensioned joint under tension load, considering all nonlinearities and different stiffness from the bolt and from the flange. To help on the understanding of this kind of joint, mainly for circular joints as found in wind turbine towers, finite element models were constructed to represent this complex non linear behavior with the objective to get a confident methodology for structural analysis for this kind of structures. 9541

Télio Fernandes Mendes, João Carlos Menezes Structural Analysis of a 100 kw Wind Turbine Tower 4.2 Convergence model Figure 4. Real behavior on loads for a pre-tensioned joint. Mendes and Menezes (2010b) presented a study and all procedures to be considered in order to obtain accurate results from the analysis. Figure 5 presents one of the steps of this study, where it was concluded as necessary for the convergence, that the full model should have the load applied in progressive steps. One should take into account the refinement on the model of the studied region, how to model the bolt head and its linkage to the flange, the non-linearity model of the contact faces, the friction between the surfaces and the iterative method for the nonlinear analysis to improve the convergence without jeopardize the results accuracy. 4.3 Global detailed model Figure 5. Reduced convergence model. 9542

Mendes (2012) presents the detailed analysis of the pre-tensioned flanged of a wind turbine tower. Figure 6 presents the global detailed model with the loads and boundary conditions built according to the definitions from the reduced convergence model. Figure 6. Symmetrical global model with loads and boundary conditions. After forty-nine iterations, the global model with the gust load converged, as seen in Figure 7, where it is presented the convergence for each one of the fifteen sub steps of loads increments. Figure 7. Convergence table. The results of the analysis are shown in Figures 8, 9 and 10, deformation, stress distribution over the critical bolt and stress distribution over the flange region, respectively. 9543

Télio Fernandes Mendes, João Carlos Menezes Structural Analysis of a 100 kw Wind Turbine Tower Figure 8. Deformation of the flange. Figure 9. Critical bolt stress distribution. Figure 10. Flange stress distribution over the critical bolt. 9544

5. RESULTS COMMENTS These results are in line with the expected behavior, compared to a structure with having one pre-tensioned bolt only. What can be evidenced is that ANSYS analyses for the pre-tensioned elements is a very useful tool to evaluate this kind of joint, since experimental data are not always available to an accurate analytical analysis. To ensure this procedure for sizing wind turbines towers or similar structures it is recommended the calibration of the finite element models with some test data. 6. REFERENCES Donadon, M. V., Savanov, R., Menezes, J. C. and Lindolfo, A. M. F., 2008, A numerical tool to design blades for horizontal axis wind turbines with variable geometry. In: National Congress of Mechanical Engineer, 5, Salvador. Engineering Science Data Unit, 1986, ESDU 84039: Strength of angles and club-foot fittings (transmitting tensile loads). Hatfield. Engineering Science Data Unit, 1995, ESDU 85021: Analysis of pre-tensioned bolted joints subject to tensile (separating) forces. London. Mendes, T. F. and Menezes, J. C., 2010a, Estudo de sensibilidade e dimensionamento estrutural de torres tubulares para geradores eólicos. In: Congresso Nacional de Engenharia Mecânica, 6, 2010, Campina Grande. Mendes, T. F. and Menezes, J. C., 2010b, Comportamento da ligação entre módulos flangeados de torres cilíndricas para geradores eólicos. AE601 Iniciação a Pesquisa. São José dos Campos: ITA. Mendes, T. F., 2012, Dimensionamento de Torre Cônica Tubular de Gerador Eólico de 100 kw, Master thesis, ITA, São José dos Campos. Schmidt, H. and Neuper, M., 1997, On the elastostatic behaviour of an eccentrically tensioned l-joint with prestressed bolts. Stahlbau. Schmidt, H., Winterstetter, T. A. and Kramer, M., 1999, Non-linear elastic behaviour of imperfect, eccentrically tensioned l-flange ring joints with prestressed bolts as basis for fatigue design. In: European Conference on Computational Mechanics. Shigley, J. E., 1984, Elementos de máquinas. v. 1. Rio de Janeiro: LTC. Verein Deutscher Ingenieure, 2003, VDI2230: systematic calculation of high duty bolted joints - joints with one cylindrical bolt. 7. RESPONSIBILITY NOTICE The authors are the only responsible for the printed material included in this paper. 9545