GUIDE TO PROPER INSTALLATION AND USE OF CANTILEVER RACKS

Similar documents
WHAT IS CANTILEVER RACK?

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

" RISKS ASSOCIATED WITH THE INSTALLATION OF THE SYSTEM

Structural Cantilever Installation Manual

Cantilevered Rail System

Standard Duty Cantilever Rack Installation and Assembly Guide

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

USER'S GUIDE FOR INSPECTION OF DAMAGED STORAGE RACK SYSTEMS DON T WAIT UNTIL IT S TOO LATE!

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

SK2000 Boltless Pallet Rack Installation and Assembly Manual

Installation and Maintenance Manual for EMH Freestanding Workstation Jib Cranes

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Cantilever Racking Store Any Size, Any Shape

Distriubted by Material Storage Systems, Inc CANTILEVER. Distriubted by Material Storage Systems, Inc

SKATEWHEEL FLOW RACK

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Lateral System Analysis and Confirmation Design

A GENERAL INSTALLATION GUIDE FOR RIDG-U-RAK DRIVE-IN / DRIVE-THRU STORAGE SYSTEMS IG-DI-1

USER'S GUIDE FOR INSPECTION OF DAMAGED STORAGE RACK SYSTEMS DON T WAIT UNTIL IT S TOO LATE!

STANDARDIZED STRUCTURES

W A R E H O U S E S O L U T I O N S

Safety on Heights: Our Policy

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Instructions for the use of the Link 4 Pallet Rack Lifter (PRL) model 5000

Keep workers and products out of harms way. STRUCTURAL GUARDS

Panduit Corporation Tinley Park, Illinois. Outset and Inset Cabinets Seismic Load Rating and Anchorage Design

Cantilever Rack System

LPI 56 Technical Guide

INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS

Modular Simplicity Dero

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Distribution of Forces in Lateral Load Resisting Systems

INSTALLING A POUR-IN-PLACE DOCK LEVELER (EH & RR)

Interior Hangers. Application

Stone and Masonry Veneer

Overturning Forces. 12 times 300 lbs = 3,600 lbs of shear force along top of wall. Shear Wall

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

Conergy SolarFamulus II

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

Cantilever Racking Store Any Size, Any Shape

Third Avenue New York, NY. Lateral System Analysis and Confirmation Design November 13, Michelle L. Mentzer.

SK3000 Structural Pallet Rack Installation and Assembly Manual

Example Hot Tub Deck Design Using ConstructionCalc Software, v2.0

SELECTIVE PALLET RACK

SECTION ALUMINUM GATES

APPLICATION GUIDE PERFORM WITH PRECISION

Allround Scaffolding

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

Site Preparation... 2

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

OSHA Rules for Scaffolding

Product Benefits & Specifications - SK3000

CANADIAN MANUFACTURED PALLET RACKING OUR STRENGTH IS OUR PRODUCT ROLLFORMED RACK

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Technical Report 3. Alyssa Stangl Structural Option Advisor Dr. Linda Hanagan L A J O L L A C O M M O N S P H A S E I I O F F I C E T O W E R

Structural Pallet Rack The ideal system for heavy-duty loads due to its greater weight-bearing capacity

PRODUCT INFORMATION Dero Hoop Rack

STRUCTURAL EVALUATION OF TARA HILLS ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

DIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK

Analysis and experimental studies of building glass facade

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Mecalux Pallet Racking Assembly

ENTRY FORM. DVASE 2014 Excellence in Structural Engineering Awards Program

Temporary Construction Loads Over I-Joist Roofs And Floors

EVERYONE'S RESPONSIBILITY

General and Technical Information

Commercial Structures

SECTION CONCRETE FORMWORK AND ACCESSORIES

SRS-02 NEW SEISMIC RESTRAINTS. Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems SYSTEMS THAT MAKE SENSE

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Adjustable Pallet Racking Installation Guide

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

Copyright Materials. American Wood Council

INSTALLATION MANUAL. All Types F Series Rev G

STATEMENT OF SPECIAL INSPECTION FORM

Tested Guardrail Post Connections for Residential Decks By Joseph Loferski, Dustin Albright, and Frank Woeste, Ph.D., P.E. Copyright.

ASSEMBLY & INSTRUCTIONS FOR USE. PALLET RACKING CITY Edition No. 2 BLS BLS AB

CHAPTER III DYNAMIC BEHAVIOR OF A LABORATORY SPECIMEN

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

Campbell County Building Inspection Division Guideline to 2018 IRC Residential Construction for Decks

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass

The Kodiak 3200 Seating System by Royal Stewart Ltd.:

Concrete Prestressed Concrete Pretensioned Concrete Posttensioned Concrete Typical Tendon Layout

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

2) Open ConstructionCalc ProBeam from Microsoft Excel: File Open. 3) Part 1 General Input. Here is a screenshot of Part 1 input.

LADDERSPAN AGR. BoSS Camlock Advance Guardrail Mobile Aluminium Tower 1450/850 Frames USER GUIDE

Transcription:

GUIDE TO PROPER INSTALLATION AND USE OF CANTILEVER RACKS The following is a guide for assembly, installation and use of Cantilever Storage systems. Please review the entire document prior to installation and use to familiarize all users with every aspect of installation and use of Cantilever Racks. Site Preparation The slab on which the cantilever column and bases are placed must be able to support the fully loaded weight of the cantilever storage system. Minimum concrete underlayment must be 3,000 PSI. Seasonal ground conditions, e.g. rain, permafrost thaw; potential subsidence must be considered. A ground survey may be required for proper installation. Tall storage systems may be subject to height restrictions and wind constraints and local permit requirements. The installation site must be level for the storage system to be stable. Appropriate preparation may need to be taken to prepare concrete slabs and or exterior areas. Non-concrete areas are not approved for cantilever installation. Cantilever Storage systems must be level and adjoining cantilever columns must be at the same height. If shimming is required to adjust the level, shims should be of steel plates as broad as or broader than the base structure width. Cantilever bases AND columns should be shimmed as needed to assure proper level alignment. Assembly Bracing Bracing must be installed between each pair of Cantilever columns. Twelve foot columns require one X-Brace and 2 Strut Braces between columns. Sixteen foot columns require one X-Brace and 3 Strut Braces between columns. Columns must be installed in sections of 2 or more columns for stability. Bracing should be placed between each column regardless of the length of the row segment or the total number of columns per row, no spaces should exist. Anchoring Upright columns and bases must be anchored to the floor using 5/8 diameter wedge anchors into a concrete slab (Columns require 2 anchors per column; bases require 4 anchors per base). Anchors should be embedded to a minimum depth of 3 ¾ into a concrete slab unless otherwise specified in local code or seismic requirements. Page 1 of 6

Fasteners Bases should be attached to Cantilever Columns with (6) ea. ¾ Bolts/Nuts Arms should be attached to Cantilever Columns with (4) ea. ¾ Grade 8.8 Metric Bolts/Nuts Cantilever Base Connection (6) ¾ Grade 8.8 (metric) X-bracing and struts should be attached to Cantilever Columns with (5) ea. ¾ Bolt/Nut X-Brace Connection (5) ¾ Grade 8.8 (metric) Bolts/Nuts All component fasteners must be tightened with the following hardware: 3/4 Grade 8.8 (metric) bolt/nut 5/8 Wedge Anchor 5/8 Grade 8.8 (metric) bolt/nut stopper hardware X-Braces Struts Page 2 of 6

SAFE USE OF CANTILEVER RACKS It is essential to system stability that columns and arms are not overloaded or damaged during use. Additionally, all personnel using Cantilever Storage Systems should be aware of the potential hazards involved. When loading equipment on cantilever arms, take care to ensure that arms do get damaged. Ensure Cantilever Storage Systems are installed on firm, even concrete. o If needed, use metal shims to adjust the bases and column to ensure it is stable and the arms are even. o Do not allow the arms to tip forward. o Do not load on the tip of arms. Ensure assistance is given to direct the forklift/crane operator to place the load carefully and evenly across all arms in the system. Ensure all personnel in the proximity of the storage system are positioned so that in the event of a loading or unloading mishap they cannot get hit by the falling load. Keep hands and body parts away from the storage system while loading and unloading. Do not crawl under loaded storage system. Do not climb on the storage system. Don t drop loads onto the arms. Ensure heaviest equipment is stored on lowest levels. On tandem racks, keep loads evenly spread on each side. CONSIDERATIONS FOR CANTILEVER RACKS Determine the Number and Spacing of Arms The load must be supported the appropriate number of arms to prevent load deflection (Fig. 1, A.2) See Page 4. Deflection may cause damage to the load being stored as well as the arms (Fig. 1, A.1). Place the load over two wooden blocks (to represent cantilever arms) as shown in next slide. If deflection is not present it is acceptable to use a two-arm system as long as the arms can support the load.? If the load shows deflection use three blocks as shown in Fig 1, A.3 or four blocks as in Fig. 1, A.4. The load should overhang the end arms by one-half the distance from the end column centerline to next column centerline with 12 between each load. Failure to observe this measure may cause an overload condition on the arms. Page 3 of 6

Place Place load load on on wooden blocks blocks to to determine the the optimal optimal number of of arms arms to to prevent prevent distortion of of the the load load The The load load should should overhang the the end end arms arms by by one-half the the distance from from the the end end upright upright centerline to to next next upright upright centerline. Fig. 1 Improperly Loaded 1/4 1/2 1/4 Two Arms 1/6 1/3 1/3 1/6 Three Arms 1/8 1/4 1/4 1/4 1/8 Four Arms A.1 A.2 A.3 A.4 DETERMINING THE LOAD CAPACITY REQUIREMENTS OF THE CANTILEVER SYSTEM Calculating Capacity requirements for Cantilever Columns The load capacity yield of the Cantilever Column is: A 12 Cantilever Column can support up to 22,000 lbs. per side, per column. A 16 Cantilever Column can support up to 22,000 lbs. per side, per column. A 20 Cantilever Column can support up to 22,000 lbs. per side, per column. In calculating the total capacity, users must consider the deflection of the load and the total weight required per level. Upon determining the load weight requirement per level, this number can be divided into the total capacity of two columns to determine how many levels and or columns will be needed for the total system requirement. The total weight of the storage system and its load needs to be considered when determining installation location to ensure the area will be able to bear the load without collapsing. The load placed on the base does not diminish the rated capacity of the column. Therefore, the heaviest loads should be placed on the base. Page 4 of 6

Proper Loading and Capacity of Cantilever Arms The load should never exceed the length of the arm. A 48" wide bundle of plywood requires a 48" long arm. Bundles of steel 24" wide require a 24" or longer arm and so on. Allow 1-2 extra to ensure that the load does not overhang the Cantilever arm. Incorrect: The load exceeds the length of the arm The load doesn t exceed the length of the arm DETERMINE THE LOAD & CAPACITY REQUIREMENTS OF THE CANTILEVER RACK SYSTEM Determine the weight per level and divide the weight by the not to exceed capacity of one arm to calculate how many arms will be needed to support the evenly distributed load in the system. Load for individual 48 x 4 Cantilever arms may not exceed 1,900#. Load on 12 tall Cantilever Columns may not exceed 22,000 lbs. per side (per column). Load on 16 tall Cantilever Columns may not exceed 22,000 lbs. per side (per column). To determine the total number of Cantilever Columns/Arms needed in a Cantilever Storage system, you must consider the length of the load, total weight on each level and total weight on the system. Examples: A. Customer needs to put 5,000 lbs. per level on 2 levels (10,000 lbs. total). This requires a basic system of 2 columns with 4 arms. B. Customer needs to put 10,000 lbs. per level on 2 levels (20,000 lbs. total). This would require a system of 4 columns with 8 arms. In a storage system, if a user can place some of that load weight on the base instead of a cantilever arm, you may be able to reduce the number of columns required. Page 5 of 6

Correct loading of racks Rated arm capacities may be seriously diminished if proper loading techniques are not observed. Loads should be placed to provide an even loading on each arm Loads create a greater bending moment on the arm the further it is placed from the column. Exceeding the loading capacity can permanently distort the arms, overstress column material and or welding on the material and lead to a catastrophic failure Back loading gives full rated arm capacity Centre loading gives near full rated arm capacity In- Tip loading may reduce arm rating by up to 50% Heaviest Loads on lower part of the rack The load placed on the base does not diminish the rated capacity of the column. Thus, the heaviest loads should be placed on the base. Page 6 of 6