Protect the Neck. Lieven Maene, MD. Marc Bosiers Koen Deloose Joren Callaert. Patrick Peeters Jürgen Verbist. Lieven Maene Roel Beelen.

Similar documents
Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Conformability without Compromise

PER F ORM ANC E b y d e s i g n. Pioneering TEVAR Therapy, Time and Time Again. CONFORMABLE

Conformability without Compromise

Zenith Alpha System, Designed for Easy and Durable repairs. Prof. Elixène JEAN-BAPTISTE (Nice)

NEW PERSPECTIVES ON CHALLENGING AAA NECKS. And why graft design matters in treating Reverse Taper Necks. Supplement to. Sponsored by Endologix, Inc.

Modular branched endograft system for aortic aneurysm repair: evaluation in a human cadaver circulation model

LINC James F. McKinsey, M.D.

DEC DEPARTMENT OF HEALTH & HUMAN SERVICES

Lombard Medical, Inc. (NASDAQ:EVAR) June 2016

Branched Grafts for Thoracoabdominal Aneurysms: Off-Label Use of FDA-Approved Devices

1. Until the CE Mark suspension has been lifted, the AFX product should not be implanted in patients.

Wireless Implantable Micromachined Pressure Sensors: Approach and Clinical Demonstration

You struggle to get into the fenestration: try a steerable guiding

A New Endoprosthesis With Sensing Capability

ENDOVASCULAR TREATMENT OF COMPLEX ABDOMINAL AND THORACOABDOMINAL

From the Society for Clinical Vascular Surgery

Conformability without Compromise. Now FDA APPROVED

The hypogastric issue: how important is the hypogastric patency? Why not a sandwich technique? Nilo J Mosquera, MD.

EVALUATING PROXIMAL AND DISTAL FIXATION ABILITY OF 8 ENDOGRAFTS USED IN EVAR

Mid-term results of the global ANCHOR registry regarding the treatment of type I endoleaks

Predictive and patient-specific numerical simulations of endovascular surgery for aortic abdominal aneurysms. Michel Rochette

Development of a Finite Element Model to Analyse the Proximal Ring of an Endovascular Device

Valiant Navion device enhancements: a case-based approach to Navion s clinical value

University Hospital. Parkland Hospital

V. Riambau and G. Mestres Vascular Surgery Division. Cardiovascular Institute Hospital Clinic. University of Barcelona

V. Riambau, MD, PhD. Professor and Chief of Vascular Surgery Division CardioVascular Institute, Hospital Clinic, University of Barcelona

KEY TO INNOVATION AT VASCUTEK JAPAN MATTERS FEBRUARY 7TH 2014

Effect of improved endograft design on outcome of endovascular aneurysm repair

Fenestrated and branched endografts: assessment of proximal aortic neck fixation

Aortica: Taking Aim at Complex EVAR with a Novel Endograft Fenestration Technology

Fenestrated and Branched Endografts: Assessment of Proximal Aortic Neck Fixation

How we deal with aortic endograft infection. Elena Iborra, Emma Espinar, Ramon Vila Hospital Universitari de Bellvitge Barcelona, Spain

ACCESS OPTIONS FOR PATIENTS WITH VENOUS OUTFLOW INSUFFICIENCY SYSTEM MERIT IS COMMITTED TO DIALYSIS ACCESS

S.M.A.R.T. Our inspiration came right from the source. Feeling is believing. S.M.A.R.T. Flex Vascular Stent System. LinkedIn page

New Fully Absorbable Patch Based Large Hole Vascular Closure Device Arne Schwindt, MD

Pre-op Planning. Dedicated to planning of Endovascular Interventions

A Coordinated Registry Network Based on the Vascular Quality Initiative: VISION. Vascular Implant Surveillance & Interventional Outcomes Network

Application for Training Centre. BSET Fellowships

Decide, guide, treat and confirm: The Philips Volcano CLI solution

TOBA II and TOBA III Clinical Programme Updates

Cre8 TM BTK polymer-free DES technology: the Activ8 clinical trial

PVL en Pacemaker rate problems solved. Tailored patient treatment, with a valve choice best for different anatomical features.

The phase I multicenter trial (STAPLE-1) of the Aptus Endovascular Repair System: Results at 6 months and 1 year

Prediction of altered endograft path during endovascular abdominal aortic aneurysm repair with the Gore Excluder

European Journal of Vascular and Endovascular Surgery

EVAR Guided by 3D Image Fusion and CO 2 DSA: A New Imaging Combination for Patients With Renal Insufficiency

12/16/2013. New Codes 175 Revised Codes 107 Deleted Codes 54 Total 336. Regan Tyler, CPC, CPC-H, CPMA, CEMC, ACS-EM

Detection of endograft fractures with multidetector row computed tomography

Cardiovascular implants Endovascular devices. Part 1: Endovascular prostheses

Citation for published version (APA): Dijkstra, M. L. (2018). Advances in complex endovascular aortic surgery [Groningen]: University of Groningen

Patient-specific simulation of stent-graft deployment within an abdominal aortic aneurysm

In-Service Presentation

A Path from RWD to RWE Stopping Over at Statistical Inference

First Experiences with the Ziehm Vision FD Mobile C-Arm with Flat-Panel Detector

A Novel Segmentation and Navigation Tool for Endovascular Stenting of Aortic Aneurysms

Catheter-less angiography for endovascular aortic aneurysm repair: A new application of carbon dioxide as a contrast agent

Vascular Graft Sepsis

Advancing minimally invasive. therapeutics through novel device. development. Minima y Invasive New Technologies T H E L E O N A M. A N D H A R R Y B.

Failure of endovascular abdominal aortic aneurysm graft limbs

Interventional Radiology

Tissue Engineered Vascular Grafts

Bioresorbable Stent Implantation for Tibial Disease

TRUFILL DCS ORBIT Detachable Coil System

The Importance of Vessel Preparation

QUALITY INNOVATION 2015

Results with intraoperative 3-D angiography

Unique technologies for the endoluminal treatment of complex PAD lesions

Mechanics of Laser Cu Stent Grafts

PEAC. May 13 // May Marie Lannelongue Hospital le Plessis-Robinson, FRANCE. Paris Endovascular Aortic Course

Endograft limb occlusion and stenosis after ANCURE endovascular abdominal aneurysm repair

SYNERGYTM. Everolimus-Eluting Platinum Chromium Coronary Stent System

Precision Vascular Robotics. Corindus Vascular Robotics (CVRS) November 2017

Precision Vascular Robotics. Corindus Vascular Robotics (CVRS) January 2018

ISO Cardiovascular implants Endovascular devices Part 2: Vascular stents Part 2: Vascular stent

The evolution of stent design for chronic iliac vein obstruction

V. Riambau, MD, PhD Prof and Chief of Vascular Surgery Division Cardiovascular Institute, Hospital Clínic of Barcelona

Company Update. 28 May REVA Medical, Inc.

EndoVascular hybrid Trauma and bleeding Management (EVTM)

Technical solutions, and clinical utility of CO2 angiography. Ulf Teichgräber, MD, MBA Department of Radiology University Hospital Jena

University of Groningen. Improving diagnostic accuracy in aortic prosthetic graft infection Saleem, Rani

Poster No.: R Page 1 of 12

ISO INTERNATIONAL STANDARD. Cardiovascular implants Endovascular devices Part 2: Vascular stents

EndoVascular hybrid Trauma and bleeding Management (EVTM)

CTA Throughout the Ages

9/29/2016. Implantable Artificial Kidney: From Silicon Chips to Renal Clearance. ESRD Statistics. Arrhythmia Care as a Paradigm

ENDOGRAFTS, PRESSURE, AND THE ABDOMINAL AORTIC ANEURYSM. A Dissertation CLARK ANDREW MEYER

The Next Generation of Stents for the Lower Extremity: What s on the Horizon?

Aortic Endografts Market

RADIATION EXPOSURE IN ENDOVASCULAR PROCEDURES - AN ASSESSMENT BASED ON EXAMINATIONS PERFORMED AT SAHLGRENSKA UNIVERSITY HOSPITAL

Prestige Pilot: Phoenix atherectomy and Stellarex DCB in BTK interventions. Michael K. W. Lichtenberg MD, FESC

Optimisation of angioplasty workflow for CO2-angiography in patients with kidney impairment

VASCULAR ACCESS PRELUDE SHEATH INTRODUCERS. Merit Medical s Innovative Family of Vascular Access Products A GREAT INTRODUCTION

CT post processing and low dose scanning

Simulator Features. Imaging. Device Simulation. Patient Management. Educational Features

Perspective on initial Limflow experience in the US. Peter A. Schneider, MD Kaiser Foundation Hospital Honolulu, Hawaii

ProCol Vascular Bioprosthesis

Alma Mater Studiorum Università di Bologna TECHNOLOGIES IN ENDOVASCULAR AORTIC REPAIR. Bologna (Italy), 5-6 December 2013 Royal Hotel Carlton

Workflow optimization in the hybrid OR. Arjan Hoksbergen, Vascular Surgeon Rutger Lely, Interventional Radiologist

Failure modes of thoracic endografts: Prevention and management

Transcription:

A.Z. Sint-Blasius, Dendermonde Marc Bosiers Koen Deloose Joren Callaert Imelda Hospital, Bonheiden Protect the Neck Patrick Peeters Jürgen Verbist OLV Hospital, Aalst Lieven Maene Roel Beelen R.Z. Heilig Hart, Tienen Lieven Maene, MD Koen Keirse

Disclosure Speaker name:...maene LIEVEN... I have the following potential conflicts of interest to report: Consulting Trivascular Medical Educator Employment in industry Shareholder in a healthcare company Owner of a healthcare company Other(s) I do not have any potential conflict of interest 2

Protect the neck 3

Protect the neck 4

Protect the neck 5

Protect the neck Pre & intra-operative Post-operative 6

Pre and Intra-operative Identification of the correct juxta-renal sealing zone Apropriate graft-size selection Correct deployment of the graft. 7

Sealing mechanisms A. SE Stent graft : Expanding diameter Spot apposition Long segment B. BE Stent graft Fixed diameter Spot contact ~ Balloon

Sealing mechanisms C. Polymer filled O-ring and PTFE body Full wall apposition Moulding Materialise

1. Juxtarenal Sealing zone identification a. In relation to the sealing mechanism 3mm = 15-20mm b. Risk-factor evaluation : thrombus, calcium, c. Preoperative image processing to predict how the graft will take position in the aorta 10

1. Juxtarenal Sealing zone identification A. Traditional case planning

1. Juxtarenal Sealing zone identification Axial B. Graft orientation planning Centerline Stent Collar Sealing Ring @ IR+13 Sealing Ring @ IR+13 Sealing Ring @ IR+13 32.7mm avg = Eval. 26.9mm min = AB 34 25.7 mm avg AB 29 22.2 mm avg. AB 26 12

1. Juxtarenal Sealing zone identification B. Graft orientation planning Corrected sealing Sealing zone zone q q Short sealing => Selective lower placement 13

1. Juxtarenal Sealing zone identification C. Risk factor calculation Thrombus Calcifications Hourglass neck Conical neck Renal stents 14

1. Juxtarenal Sealing zone identification D. Intraoperative marking of Sealing zone 15

1. Juxtarenal Sealing zone identification Trivascular Ovation

Postoperative protection Sealing without Endoleak Future aortic neck dilatation 17

2. Juxtarenal sealing zone stability A seal can be achieved in a very short sealing zone A change in the neck can compromise the sealing, resulting in late type 1a endoleak and / or migration Neck dilatation : Stent Graft induced? Natural evolution? 18

Forces at work in the aorta : SE Stentgraft

SE Stentgraft

What we observe BE stent grafts

What we observe BE stentgrafts & SE stentgrafts 23

Sealing by non-expansive polymer-filled rings No graft induced chronic outward force at the infrarenal aorta Change in outward blood pressure to the aortic wall? Stabilising the infrarenal wall stress? 24

Zone B Zone C 25

Volumetric Case analysis 12 months 36 months Materialise 26

Case Neck : straight 8 mm Trivascular Ovation Stent graft (23) Bilateral extensions

Case 5 years follow-up Fixed diameter of the proximal sealing zone Complete exclusion of the aneurysm with dramatic decrease of AAA diameter 28

Proximal Neck diameter average expansion (mm) Can we protect the neck 5,0 Aortic Neck Dilatation Over Time* 4,7 4,0 3,6 3,0 2,4 2,0 1,0 0,0 0,4 0,0 0,0-0,2 0,8 0,0 0,2-1,0 Baseline 1 Year Growth 2 Year Growth 3 Year Growth 1 2 3 Self-Expanding Stents Open AAA Repair Ovation System *Based on all known peer-reviewed published clinical data with clearly outlined methodology to measure neck dilation in patients with self-expanding AAA stent grafts; measurement methodology in cited studies is comparable to measurement methodology in Ovation Pivotal Trial 3,4. 1 Monahan JVS 2010: 52: 303-7 N=46. Devices: Cook Zenith 2 Rodway Eur J Endovasc Surg 2008; 35: 685-93 EVAR: N=67, Open: N=56. Data available for up to 2 years. 3 Core Lab Data. Ovation Global Pivotal Trial 4 Neck dilation in proximal neck defined as growth > 3mm at 10mm below renals, 13mm below renals, and 15mm below renals 29

2014 TriVascular, Inc. Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. Ovation Global Pivotal Trial 3 Year Results A pivotal clinical study to evaluate the safety and effectiveness of the TriVascular Ovation Abdominal Stent Graft System. 138 patients were available for evaluation at 3 years. Technical Success 1 All (N=161) Defined as successful, delivery and deployment of one aortic body and two iliac limbs 100% Safety 2 Treatment to 30 Days 31 to 365 Days 366 to 730 Days 731 to 1095 Days Freedom From Major Adverse Events 97.5% 96.2% -- -- Freedom From Device Related Major Adverse Events 100% 100% -- -- Freedom from Rupture 100% 100% 100% 100% NO Ruptures Conversions Migration type I & III Endoleak Freedom from Conversion to Open Repair 100% 100% 100% 100% Effectiveness 3 30 Day 1 Year 2 Years 3 Years Freedom from Type I and III Endoleaks 100% 100% 100% 100% Freedom from Migration Baseline 100% 100% 100% Data as of July 25, 2014 1 Technical Success based on investigator reports 2 Major Adverse Events and Device Related Major Adverse Events based on Clinical Events Committee (CEC) adjudicated data. Rupture and Conversion to Open Repair based on investigator reports 3 Endoleaks and Migration rates based on Core Lab Data (M2S) 4 Type II endoleaks reported in all cases of AAA Enlargement. Analysis windows are: 1 year (305 to 547 days) and 2 years (548 to 911 days 30

Can we protect the neck YES Preoperative image processing, graft-selection and intraoperative accurate visualisation are mandatory 31

Trivascular Ovation 32

INDICATIONS FOR USE: The TriVascular Ovation platform (including Ovation, Ovation Prime and/or Ovation ix Abdominal Stent Graft Systems) is indicated for treatment of patients with abdominal aortic aneurysms having the vascular morphology suitable for endovascular repair, including: adequate iliac/femoral access compatible with vascular access techniques (femoral cutdown or percutaneous), devices, and/or accessories; proximal aortic landing zone: with an inner wall diameter of no less than 16 mm and no greater than 30 mm at 13 mm below the inferior renal artery, and with an aortic angle of 60 degrees if proximal neck is 10 mm and 45 degrees if proximal neck is < 10 mm; distal iliac landing zone: with a length of at least 10 mm, and with an inner wall diameter of no less than 8 mm and no greater than 25 mm (no greater than 20 mm for Ovation/Ovation Prime). CONTRAINDICATIONS: The systems are contraindicated for use in patients who have a condition that threatens to infect the graft and in patients with known sensitivities or allergies to the device materials (including polytetrafluoroethylene [PTFE], polyethylene glycol [PEG]- based polymers, fluorinated ethylene propylene [FEP] or nitinol). Also consider the information in Section 4 Warnings and Precautions of the systems Instructions for Use. Refer to Instructions for Use at TriVascular.com for more information concerning Indications, Contraindications, Warnings and Precautions, and Adverse Events. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. NOTE: Not all product components are available in every country. Please consult with your TriVascular representative to confirm product availability. CE marked. Please refer to current product Instructions for Use.