DICTATOR Lift Shaft System

Similar documents
SECTION SECTIONAL OVERHEAD DOORS

Protective devices according to EN ISO 12100

Series ESK / ESB. Cabinets in Modular Design. Manufacturing Program: ESK-20 ESK-40 ESK-80 ESB Sandwich construction 20 mm, 40 mm and 80 mm

Tender specification KLAUS Multiparking TrendVario 4300

SECTION SECTIONAL OVERHEAD DOORS

Standard program overview fire doors

HEAVY STEEL CONSTRUCTION

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

MONK W20 range of mild steel windows

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS

TRITEC light Steel Panel Formwork

Aluminium SLIDING & BI-FOLD DOOR SYSTEMS

Reinforced concrete double walls

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

BLUEKIT VENTILATION FLAPS

Custom Made OVERHEADDOORS, the quality solution for.

ACCESSORY BUILDING. Building Permit Requirements: (must be completed before submitting application)

Sub-construction for Wall-mounted Longlight

SECTION SECTIONAL OVERHEAD DOORS

Planning and installation instructions

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

VPL-3200B Residential Vertical Platform Lift Technical Specifications

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS

Curtain Wall Stick System (Capped)

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS

HAAS-THERM. Commercial Insulated Steel Doors. Models CHT-710, CHT-716, CHT-732, CHT-780, and CHT-790

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

Section : 100 TRESHOLD STAIRS DEPARTMENT NGL HALLWAY TOWARDS MUSEUM FFL DISABLED WC FEMALE WC MALE WC FFL 95.

SECTION SECTIONAL OVERHEAD DOORS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

Thousands produced. GEBHARDT ConVer Goods Lifts modular and customised

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

The Versatile & Practical Choice. Gartec Goods Lifts. Modular & Customised

Reinforced concrete double walls

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

MISER-THERM. Commercial Insulated Steel Doors. Models CMT-610, CMT-616, CMT-680, and CMT-690

ThermaSteel Corporation ASSEMBLY MANUAL

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

SECTIONAL OVERHEAD DOORS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

RHINO-STOP Modular Vehicle Impact Barriers

SECTION ACCESS DOORS AND FRAMES

Northlights using VELUX Modular Skylights

Residential solutions. Steel, aluminium and fire doors

Sub-construction for Atrium Ridgelight

External Reinforcement System

Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

SECTION SECTIONAL OVERHEAD DOORS

Type II Environmental Declaration according ISO 14021:2001/A1:2011

Sept 30, 2004 Page 1

NBB. Outdoor Shelters. Entrance Shelters & Walkways. & Cigarette Litter. Disposal Products

A Comparative study on the Performance of PEB with CSB considering various parameters

BARRIER BARRIER. quick installation. high quality collective side protection. ideal for escape routes. pleasing, unobtrusively design

FIREMASTER 60 SERIES. Fire Resistant, Affordable, Innovative

LUXALON. Other Luxalon products. QuadroCladn. Sandwich Wall. Multiple Panel Façade. Sun Louvres. Ceilings and Soffits

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

The Finnish Quality Since 1960

SECTION COLD-FORMED METAL FRAMING

Sliding Door Systems

Alisply Walls. Product brochure

Expand your horizons... High quality Aluminium Door & Window Systems Folding Doors Slide & Turn Doors Sliding Doors Windows

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

0331 Brick and block construction

Modular Scaffolding MEKA 48

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CWCT CURTAIN WALL INSTALLATION HANDBOOK

Modular Floor Standing Enclosures Steel Powder-Coated MF1S SINGLE DOOR IP55

Presentation of prefabricated houses. - Main equipments. - Assembly steps. - Some realisations

Wall bracing panel requirements

BEARING METAL STUD FRAMING

One and Two Family Additions

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

ARCHITECTURAL SPECIFICATIONS

Task Infracon Pvt. Ltd. Think Better; Plan Better ; Build Better

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS. a r c h i t e c t u r e m a d e o f s t e e l STEEL INOX

GA APPLICATION OF GYPSUM SHEATHING

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

STATEMENT OF SPECIAL INSPECTION FORM

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

HunterDouglas NBK Ceramic TERRART [Large/Mid/Shingle/Light/Baguette) Terracotta Façade System

Complete Selection of High Quality Commercial Doors COMMERCIAL DOORS. Exemplary in quality, safety and design

Tender specification KLAUS Multiparking MultiBase 2072 outdoor installation EB MultiBase 2072 outdoor installation DB

subtle form perfect function Quadra & Una Riser door systems Detailed product guide BIM L D11/1 [31.59] X Uniclass EPIC CI/SfB

Tender specification KLAUS Multiparking MultiBase U1 EB / MultiBase U1 DB

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION

Transcription:

DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings but also when modernizing existing houses. The DICTATOR modular lift shaft system offers the ideal solution for all cases where a concrete lift shaft is not available or cannot be built for architectural reasons or lack of space. Under the Construction Products Regulation 305/2011/EU only shaft systems may be mounted which have been certified according to EN 1090 and the production of which is subject to constant supervision. The DICTATOR lift shaft system meets these demands. More essential advantages: - Solid, self supporting system - Easy installation without dirt because all components are bolted together. - Modular and therefore very flexible - Offers various individual designs. - For interior and exterior installation - Retrofitting into existing houses - Comes prepared for the lift to be fitted into the lift shaft sytem (brackets to hold the rails, space to house the machinery on top etc.). - Complete installation from inside the shaft Technical Data Certified according to EN 1090 in accordance with the Construction Products Directive 305/2011/EU Rated load of the lift Type of lifts Max. interior dimensions Max. height of the shaft Finish Certificate of conformity max. 600 kg for lifts with rear rails max. 750 kg for lifts with lateral rails all types, hydraulic and electrical 1950 x 1950 mm 26 m polyester powder coated for outdoors: additionally hot galvanized 0035-CPR-1090-1.00963.TÜVRh.2014.001 Tel. +49(0)821-24673-0 Fax +49(0)821-24673-90 E-mail info@dictator.de 1015 Page 01.013.00

Components Components The DICTATOR lift shaft system consists of various components. Varying combinations of the standard elements permit to adapt the lift shaft system to the most different requirements. This permits an economic, efficient production without reducing the possibilities for a bespoke, flexible design. The main components are described in the following (see also illustrations no. 1, 2 and 3). 1c Lifting beam 1) Load carrying components a) Columns - Standard 80 x 80 mm (The columms on the sides where the rails are fixed must always be of the standard profile 80 x 80 mm.) - Opposite sides 80 x 35 mm possible; - Special profiles on demand b) Crossbeams c) Upper beams with the lifting beam for installation and maintenance 3 2) Reinforcements (depend on the lift to be built into the lift shaft) a) Reinforcements in the columns b) Diagonal braces between the beams (depend on the size of the lift shaft, the type of facing, the rated load) 1b 1a Reinforcements (2a) Braket for fixing the rails (3) Beam (1b) Column(1a) Ill. 1: Load carrying components of the shaft system Diagonal braces (2b) Ill. 2: Components of the DICTATOR lift shaft system 3) Fixing brackets for the rails Fixing brackets or plates, depending on the type of lift and rails, prepared to be bolted to the shaft system. They are normally produced to fit the rail fixtures used by the lift erecting company. Oblong holes in the brackets/plates permit an easy fitting and adjustment of the rail fixtures. Page 01.014.00 Tel. +49(0)821-24673-0 Fax +49(0)821-24673-90 E-mail info@dictator.de 1015

Components - continued Ill. 3 a/b: Examples of fixing brackets/plates for the rail fixtures of the lift companies 4) Facings a) Closed sheet steel panels b) Perforated sheet steel panels c) Frames for window panes (supplied by the customer) d) Special designs or preparation for those on demand (indicate weight and dimensions - for static reasons) Ill. 4a: Lift shaft with closed sheet steel panels... Ill. 4d: Special design: lift shaft closed with sandwich panels Ill. 4c: Lift shaft with window panes Ill. 4b:...or perforated panels 5) Roof Normally made in two parts, a) straight for interior use b) slightly inclined for exterior use Ill. 5: Construction of the roof Tel. +49(0)821-24673-0 Fax +49(0)821-24673-90 E-mail info@dictator.de 1015 Page 01.015.00

Technical Data Materials Upper beams (depend on the type of lift) hot-drawn U-profiles or normal beams Columns, beams, reinforcements, brackets/plates for the rail supports 4 mm thick sheet steel, cold formed Panels, roof 1.5 mm thick sheet steel Bolts for the columns M 12 for the beams, panels M 10 Finish For interior use For outdoors powder coated, light textured paint finish for colours see separate table (sent on demand) Hot galvanised and powder coated (colours as above) Load / Fastening of the Shaft Columns each standard column (80 x 80 )with reinforcement 2500 kg Lifting beam max. 1000 kg Those loads are valid for lift shaft systems being installed inside a building or if outdoors are leant and fixed directly to the building. At least 2 columns of the lift shaft have to be fixed every 3 m in the vertical. In order to assure the smooth and reliable function of the door operators, this has always to be on the side of the access (see ill. 6a/6b). Ill. 6a Ill. 6b Page 01.016.00 Tel. +49(0)821-24673-0 Fax +49(0)821-24673-90 E-mail info@dictator.de 1015

Weather-Proofness, Static Calculation, Dimensions Ventilation / Insulation The necessary ventilation of the lift shaft is achieved by using perforated sheet steel panels below the upper beams. It depends on the area and the travel. The standard lift shaft system with sheet steel panels or window panes is not insulated and waterproof. When the lift shaft is installed outdoors, it is sealed on site with silicone. If the lift shaft system has to be insulated and sealed, it is possible just to use the load carrying components and reinforcements without panels. The shaft can then be covered e.g. with sandwich panels (see ill. 4d) or an aluminium framework with window panes can be fixed to the shaft system. A further possibility is e.g. to close the shaft from the outside with a simple brick wall or a dry construction and apply plaster (see ill. 7). Ill. 7 Static Calculations A general static calculation for the maximum dimensions (height 26 m, inner dimensions 1950 x 1950 mm) is available. An abbreviated version of this calculation can be provided without charge. If the lift shaft is panelled by the customer, the aprox. weight and the type of paneling must be indicated in the order. DICTATOR then verifies whether the basic data of the standard static calculation are still valid. On demand DICTATOR can also provide a detailled static calculation. This is always necessary, when the lift shaft is installed at more than 1.5 m distance from the building, when special wind conditions apply or a paneling with high own weight is used. This static calculation is charged separately. Dimensions Inner dimensions max. 1950 x 1950 Tel. +49(0)821-24673-0 Fax +49(0)821-24673-90 E-mail info@dictator.de 1015 Page 01.017.00

Variations / Required Data Variations The DICTATOR lift shaft system offers both technical and architectural versatility. It is individually designed, thus optimising the coordination of the requirements of the installed lift and the design of the installation site. Required Data For an offer the following information is required: - Dimensions of the site for the lift shaft and the travel/total height - Lift to be installed - Pit and headroom (height available from the floor of the upper landing to the ceiling) - Design (sheet steel panels, window panes etc.) - Inside or outdoor installation In case of an order the following additional data: - Binding installation plan with horizontal and vertical projections and all necessary dimensions - Detailed drawing of the rail fixing brackets - Detailed drawing of the landing doors - Detailed drawing of the vertical projection of the access side to the lift shaft. If the DICTATOR lift shaft system is used in combination with the DICTATOR home lift DHM 500 or the lift DHE, we just need the information concerning the design of the lift shaft. Page 01.018.00 Tel. +49(0)821-24673-0 Fax +49(0)821-24673-90 E-mail info@dictator.de 1015