State of the Art (SOTA) Manual for Volatile Organic Compound Storage Tanks (greater than or equal to 2,000 gallons)

Similar documents
General Permit (GP-016A) for Manufacturing and Materials Handling Equipment

Overlapping Wastewater Air Regulations

RULE PHARMACEUTICAL AND COSMETIC MANUFACTURING OPERATIONS (Effective 10/18/88: Rev. Adopted & Effective 5/15/96)

15A NCAC 02Q.0102 is amended with changes as published in 30:07 NCR as follows:

State Of The Art (SOTA) Manual For Non-Hazardous Onsite Remediation Processes

Minor Source Permitting Guidance for Facilities Subject To Federal Standards

State of the Art (SOTA) Manual for Stationary Gas Turbines

Title V. Model General Permit Template SERIES 2 LOADING RACKS. Template # SJV-LR-2-1

PERMIT TO INSTALL. Table of Contents

Proposed Repeal of Volatile Organic Compounds (VOC) Regulations for Pulaski County

CHAPTER 6: AIR EMISSIONS

Technical Contact. Reed Caron Quality Manager (704) Airport Road Monroe, NC 28110

New Source Performance Standards (NSPS) 40 CFR 60 Subpart OOOO for Storage Tanks (Part 1)

DRAFT Procedures for Quantifying Fugitive VOC Emission Sources at Petroleum Facilities

YOLO-SOLANO AIR QUALITY MANAGEMENT DISTRICT REASONABLY AVAILABLE CONTROL TECHNOLOGY (RACT) STATE IMPLEMENTATION PLAN (SIP) ANALYSIS

Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution (40 CFR 60, Subpart OOOO) Air Quality Compliance

RULE SUMMARY. Purpose of Change (Why)

STATEMENT OF BASIS for NEWARK BAY COGENERATION PARTNERSHIP L.P.

DRAFT FOR PUBLIC COMMENT MARCH 16, VOC ANALYSIS METHODS

Title V. Model General Permit Template SERIES 1 LOADING RACKS. Template # SJV-LR-1-1

AMENDATORY SECTION SECTION 1.07 DEFINITIONS

MEMORANDUM June 30, Phillip Fielder, P.E., Permits and Engineering Group Manager

Recent Postings of Broadly Applicable Alternative Test Methods. SUMMARY: This notice announces the broadly applicable alternative test method approval

New Source Performance Standards (NSPS) 40 CFR 60 Subpart OOOO for Storage Tanks

An Overview of Proposed Petroleum Refinery Fenceline Monitoring Requirements. A&WMA ACE 2015 Monitoring HAPs in Ambient Air Paper 309 June 23, 2015

RCRA Subpart AA - Air Emission Standards for Process Vents

The 3 N s of Air. Diane H. Leche Air Permit Coordinator ExxonMobil Baton Rouge

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

NEW JERSEY STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION NEW JERSEY ADMINISTRATIVE CODE TITLE 7, CHAPTER 27, SUBCHAPTER 17

NEW JERSEY STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION NEW JERSEY ADMINISTRATIVE CODE TITLE 7 CHAPTER 27 SUBCHAPTER 17

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. January 26, NEW SOURCE REVIEW PERMIT TO INSTALL No.

Technical Contact. Conrad Carter, Jr., P.E. President (704) PO Box 1760 Albemarle, NC

Hazardous Air Pollution Prevention (HAP2) Project Final Report to EPA

San Joaquin Valley Air Pollution Control District. Procedures for Quantifying Fugitive VOC Emissions At Petroleum and SOCMI Facilities

MICHIGAN DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENT AIR QUALITY DIVISION. March 31, PERMIT TO INSTALL No A

Notice of Construction (NOC) Worksheet

Air Permitting for Major Sources/Title V (Part 2)

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. March 17, 2004 NEW SOURCE REVIEW PERMIT TO INSTALL

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. November 8, PERMIT TO INSTALL No A

SLIDES: Details of the Regulatory Framework: Air Quality Regulation of Oil and Gas Development

Administrator means the Administrator of the United States Environmental Protection Agency and his or designee.

Modeling Parameters. Exit Velocity Exit Temp. Location longitude

GUIDANCE DOCUMENT April 6, Guidance on Estimating Condensate and Crude Oil Loading Losses from Tank Trucks

AIR POLLUTION CONTROL DISTRICT FINAL 2009 REASONABLY AVAILABLE CONTROL TECHNOLOGY STATE IMPLEMENTATION PLAN

RULE CRUDE OIL STORAGE TANK DEGASSING OPERATIONS (Adopted 11/8/94) b. Has a storage capacity greater than 2,000 barrels.

RULE 4651 SOIL DECONTAMINATION OPERATIONS (Adopted April 16, 1992; Amended December 17, 1992; Amended September 20, 2007)

EPA's Proposed Air Pollution Standards for the Oil and Natural Gas Sector Preliminary Analysis September 2011

e-cfr Data is current as of October 16, 2017

Pre-Publication Draft - September 21, 2016 APD MARINE LOADING COLLECTION EFFICIENCY GUIDANCE

Best Practices for Using Flares to Meet Proposed EPA Emissions Regulations for Hydraulically Fractured Natural Gas or Oil Wells

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. February 3, NEW SOURCE REVIEW PERMIT TO INSTALL No.

401 KAR 60: C.F.R. Part 60 standards of performance for new stationary sources.

Guidance on Estimating Condensate and Crude Oil Loading Losses from Tank Trucks

2008 EIGHT-HOUR OZONE REASONABLY AVAILABLE CONTROL TECHNOLOGY DEMONSTRATION FOR SAN DIEGO COUNTY FINAL - DECEMBER 2016

Technical Contact. Edward Sievers Plant Manager (828) P. O. Box 2029 Hickory, NC 28603

NEW JERSEY STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION NEW JERSEY ADMINISTRATIVE CODE TITLE 7 CHAPTER 27 SUBCHAPTER 10. Sulfur in Solid Fuels

AIR EMISSION PERMIT NO IS ISSUED TO. Kaneb Pipe Line Operating Partnership, L.P. a Valero L.P. company. for

RELEASE POINT TYPE Enter or select one of the following stack/emission point release orientation: downward

Air Quality Requirements for Oil and Gas Facilities in Colorado

I. California Health and Safety Code (CH & SC) Exemptions

Technical Contact. Jeff Hardin SH&E Manager (704) Rocky River Road North Monroe, NC 28110

June 18, Via Electronic Mail

REASONABLY AVAILABLE CONTROL TECHNOLOGY (RACT) STATE IMPLEMENTATION PLAN (SIP) UPDATE ANALYSIS STAFF REPORT

Ozone State Implementation Plan (SIP) Revision. Reasonably Available Control Technology (RACT) as Applicable to the 8-Hour Ozone Standard

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM. October 27, 2010

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. APPENDIX D: Technical Support Document August 18, 2011 APPENDIX D

Volatile Organic Compound Emissions Results from DCU Depressurization Vent Testing. Presented by: Chris Weber, Senior Chemist, URS Corporation

NSPS Subpart OOOO Overview

Supersedes: 11/15 (Rev. 03) Preparer: Owner: Approver: EHS Team Member EHS Team Member EHS Manager

PRIMARY OR ALTERNATIVE OPERATING SCENARIO

SUPPLEMENT TO PERMIT NO Connolly North America, Inc Oakland Park Boulevard Highland Park, Michigan August 10, 2000

6NYCRR Part 212 Process Operations

NSPS QQQ Insights Bill Stewart February 2017

07/08 TABLE OF CONTENTS: 1

Case 1:18-cv SOH Document 1 Filed 12/14/18 Page 1 of 69 PageID #: 1 IN THE UNITED STATES DISTRICT COURT FOR THE WESTERN DISTRICT OF ARKANSAS

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. June 24, 2016 PERMIT TO INSTALL ISSUED TO Gerdau Bassett Street Facility

Tennessee Gas Pipeline Company, LLC Compressor Station Whites Creek Pike Page 1

ADEQ MINOR SOURCE AIR PERMIT

GOVERNMENT of PUERTO RICO OFFICE OF THE GOVERNOR ENVIRONMENTAL QUALITY BOARD

ENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION

Michigan Department of Environmental Quality - Air Quality Division ADDITIONAL TECHNICAL INFORMATION FOR BOILERS

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. July 24, 2015 PERMIT TO INSTALL ISSUED TO St. Marys Cement, Inc.

Serving Two Masters; Understanding Texas and EPA Permitting Programs

Complying with NSPS Regulations Governing Air Emissions from Natural Gas Well Sites

Marquette General Health System December 11, 2001 Permit No B Page 1 of 8. Table of Contents

MECKLENBURG COUNTY - A i r Q u a l i t y C o m m i s s i o n -

Air Pollution Control Operating Permit Significant Modification

RULE GASOLINE AND ROC LIQUID STORAGE TANK DEGASSING OPERATIONS (Adopted 11/8/94)

N.J.A.C. 7:14A-1 POLLUTANT DISCHARGE ELIMINATION SYSTEM SUBCHAPTER 21. REQUIREMENTS FOR INDIRECT USERS

PRETREATMENT STREAMLINING FINAL RULE FINALLY APPROVED

Title V. Model General Permit Template SERIES 1 FLARES. Template # SJV-FL-1-1

EPA s Proposed Emission Standards for New and Modified Sources and Draft Control Technique Guidelines for the Oil and Natural Gas Sector

July 5, U.S. Environmental Protection Agency Air Docket Mailcode: 6102T 1200 Pennsylvania Avenue, NW Washington, D.C

TITLE V OPERATING PERMIT STATEMENT OF BASIS

ATTACHMENT-1 BACKGROUND:

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION MARCH 16, 2004 NEW SOURCE REVIEW PERMIT TO INSTALL 25-03A

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. November 15, 2013 PERMIT TO INSTALL

STATEMENT OF BASIS. Cheney Lime & Cement Company Landmark Plant Alabaster, Alabama Shelby County Facility No

U.S. EPA S MAY 12, 2016 ACTIONS AFFECTING THE OIL AND GAS INDUSTRY

Refinery Benzene Fenceline Monitoring: Considerations in Addition to Cost

Transcription:

State of the Art (SOTA) Manual for Volatile Organic Compound Storage Tanks (greater than or equal to 2,000 gallons) July 1997 State of New Jersey Department of Environmental Protection Air Quality Permitting Program

State of the Art (SOTA) Manual for Volatile Organic Compound Storage Tanks (greater than or equal to 2,000 gallons) Section 3.1 Table of Contents Section Page Number 3.1: SOTA Manual for VOC Storage Tanks...3.1-3 3.1.1: Scope...3.1-3 3.1.2: SOTA Performance Levels...3.1-3 3.1.2.1: Storage Tanks Subject to MACT...3.1-3 3.1.2.2: Storage Tanks Not Subject to MACT...3.1-3 3.1.3: Technical Basis and References...3.1-4 3.1.4: Recommended Review Schedule...3.1-5 3.1-2

3.1 SOTA MANUAL FOR VOC STORAGE TANKS 3.1.1 Scope These State of the Art (SOTA) levels apply to all newly constructed, reconstructed or modified storage vessels, storing any volatile organic compound (VOC) with a capacity equal to or greater than 2000 gallons. 3.1.2 SOTA Performance Levels SOTA performance levels are not a substitution for complying with the regulations contained in the New Jersey Administrative Code (N.J.A.C.) 7:27, particularly section - 16.2 (Storage of VOC s). These regulations must be met for all tanks. For some tanks, there will be no additional SOTA levels, and compliance with N.J.A.C. 7:27 will be sufficient. 3.1.2.1 Storage Tanks Subject to MACT If a storage vessel is subject to 40 CFR 63, Subpart CC, National Emission Standards for Hazardous Air Pollutants from Petroleum Refineries, then compliance with all of the provisions of that Maximum Achievable Control Technology (MACT) standard is equivalent to SOTA. If a storage vessel is subject to 40 CFR 63, Subpart G, Standards for Synthetic Organic Chemical Manufacturing Industry (SOCMI) Storage Tanks, then compliance with all of the provisions of that MACT standard is equivalent to SOTA. 3.1.2.2 Storage Tanks Not Subject to MACT A. Storage Tanks with a capacity greater than or equal to 2,000 gallons, and storing Group 1 Toxic Substances (TXS) greater than 50% by volume, are required to install a vapor control system. The control system shall be designed and operated to reduce uncontrolled TXS emissions by a minimum of 99%. B. Storage tanks with a capacity greater than or equal to 2,000 gallons, and storing a VOC with a vapor pressure greater than 11.1 pounds per square inch absolute (psia), are required to install a vapor control system. The control device shall be designed and operated to reduce uncontrolled VOC emissions by a minimum of 95% or greater. C. Storage tanks with a capacity greater than or equal to 2,000 gallons, and storing a VOC with a vapor pressure less than or equal to 11.1 psia must meet the criteria in the following table. 3.1-3

Vapor Pressure of Contents (psia) Tank Capacity State of the Art Standard Less than 0.75 All sizes Compliance with N.J.A.C. 7:27-16.2 is SOTA 0.75 or greater, but less than 4.00 4.0 or greater, and less than 11.1 psia Less than 40,000 gallons Compliance with N.J.A.C. 7:27-16.2 is SOTA 40,000 gallons or greater SOTA is having a floating roof configuration as described below, and compliance with N.J.A.C. 7:26-16.2 Less than 20,000 gallons Compliance with N.J.A.C. 7:27-16.2 is SOTA 20,000 gallons or greater SOTA is having a floating roof configuration as described below, and compliance with N.J.A.C. 7:27-16.2 For a tank required to have a floating roof to comply with this SOTA standard, one of the following configurations is required: internal floating roof with a foam or liquid filled seal internal floating roof with a double wiper seal internal floating roof with a mechanical shoe seal external floating roof with a foam or liquid filled seal with a secondary wiper seal external floating roof with a mechanical shoe seal with a secondary wiper seal The technical and operating specifications for the above SOTA floating roof configurations are the same as those located in the New Source Performance Standard (NSPS - 40 CFR Part 60 Subpart Kb). 3.1.3 Technical Basis The SOTA workgroup evaluated information from the following sources in determining the SOTA Performance Levels. A. Department of Environmental Protection, Bureau of New Source Review permit files for storage tanks. B. Existing NSPS, National Emissions Standards for Hazardous Air Pollutants (NESHAP), and MACT standards. C. Storage Tank Manufacturers. 3.1-4

D. New Jersey Administrative Code 7:27-16, Control and Prohibition of Air Pollution By Volatile Organic Compounds. The SOTA levels indicated above are what is required by applicable Federal and State of New Jersey regulations. 3.1.4 Recommended Review Schedule The manual will be revised any time N.J.A.C. 7:27-16 and 17 are revised, and any time a new MACT standard, NSPS, or NESHAP standard is published. The manual may also be revised if new storage technologies that minimize emissions become available. This manual is expected to be revised by July 2000. 3.1-5