SWING DOOR SPECIFICATION

Similar documents
SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

T SERIES WINDOW SPECIFICATIONS

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

T series Storefront Framing Flush Glazed Thermally Broken Product Details

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

TMS 114 XT TECHNICAL MANUAL

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

SECTION ALUMINUM STORM WINDOWS

Building Your Visions

System WV410 Storefront Window System

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM WINDOWS

SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM

HORIZONTAL SLIDER SERIES 700. Main Frame Depth: 2 3/4 Glazing Thickness (Maximum): 5/8 Thermal Break:

SECTION STAINLESS STEEL WALL PANELS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Series B450 Guide Specification

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

System Thermal Clip Storefront System

Series 510-I Thermal Heavy Commercial Projected Window

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

TMS 152 / 152T / 152XT TECHNICAL MANUAL

TMW 450 TECHNICAL MANUAL

7000 Series Curtain Wall Information Specifications

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

System WV410 Storefront Window System

Series 700 Series 7000 * 4 Heavy Commercial Roto-Vent Rotating Ventilator Window

PROJECT IN SERIES 1300 NARROW SIGHT LINE AAMA/WDMA/CSA 101/I.S.2/A Structural Performance:

Series x Thermal Triple Set Storefront Framing

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

Impact-Resistant Entrances Series

Aluminum Storefront Systems SERIES 200, 300 and 500 DOORS GUIDE SPECIFICATIONS

Series 890-I Equa-Vu Heavy Commercial Projected Window

STEEL WINDOWS & DOORS SECTION 08510

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION ALUMINUM WINDOWS

PROJECT OUT SERIES 6300 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

MPG Series 2250T Thermally Broken Aluminum Window

PROJECT OUT SERIES 6300 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

CASEMENT PROJECT OUT SERIES 2400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 2 3/8

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

Series x Thermal Triple Set Storefront Framing

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

North Hanover Township School District North Hanover Township, New Jersey

SECTION ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

SERIES /8 HORIZONTAL SLIDING WINDOW (CW30)

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

SECTION ALUMINUM CURTAIN WALL PART 1 - GENERAL

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

Guide Specifications- Section

YSD 700H PRODUCT DATA

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

ESTIMATING/TAKE-OFF AND ORDERING GUIDE

4600 Series Specifications (Section 08520)

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

SECTION ALUMINUM WINDOWS

Aluminum-Framed Entrances and Storefronts

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

Installation Instructions

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

WESTECK WINDOWS and DOORS

SECTION DETAILS (MECHANICALLY ASSEMBLY)

apexfacades.com apexfacades.com. Keystone Pg- 1

1 3 4 Tie Rod Aluminum Swing Entrance Doors

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

AUGUST, 2017 IR 500/501 Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

Heavy Commercial / Architectural Projected Windows Series L900T AW150

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Series Heavy Commercial Projected Window

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

SIGNATURE SERIES UNIT WALL

SECTION METAL WALL PANEL SYSTEM

SECTION A1 SERIES 200, 300 AND 500 ENTRANCE DOORS

ALL-ALUMINUM DOOR & WINDOW FRAMING

WESTECK WINDOWS and DOORS

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

Guide Specifications- Section

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

PRODUCT SPECIFICATION UNITIZED CURTAIN WALL THERMALLY BROKEN ALUMINUM AWNING/ FIXED WINDOW

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Hurricane System

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR

DOUBLE HUNG SERIES 3500 AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.

SECTION VINYL (PVC) WINDOWS

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

Transcription:

SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified herein. Drawings and specifications for work in this section are based upon DESA series doors. (select series type: 100.350.500.100T/B.350T/B.500T/B ). Whenever alternative products are to be considered, submit supporting technical literature and samples for review and comparison by Consultant. Doors to fully comply with applicable standard specifications as typically referenced to the following requirement criteria: Air and water tightness, wind and other load resistance. their Weathering shall be elastomeric or wool pile and of size and density appropriate for their Construct door from extrusions of size and shape as shown on shop drawings, rails and stiles shall be porthole type extrusions. Corner joinery shall be accurately assembled with mechanical clip fasteners and deep penetration plug and fillet welds. Duranar Fluoropolymer paint: AAMA 2605 Hardware Hardware shall be the entrance manufacturers standard unless stated otherwise by the If alternative hardware is selected by consultant the required templates and physical hardware must be submitted for assembly and fabrication. Doors shall be installed, glazed and adjusted according to the manufacturers instructions and approved shop drawings. All items in this section shall be set level, square and plumb and at their correct location and alignment with 02/05

STOREFRONT FRAMING B1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance and window frames as detailed on the drawings and specified herein. Drawings and specifications for work in this section are based upon DESA series framing system. (select series type: 175.200.400). Whenever alternative products are to be considered, submit supporting technical literature and samples for review and comparison by Consultant. Framing system to fully comply with applicable standard specifications as typically referenced to the following requirement criteria: Air and water tightness, wind and other load resistance. their Weathering shall be elastomeric or wool pile and of size and density appropriate for their -175 series 1 3/4" (44.5) and/or 200 series 2" (50.8) for flush glazing, both maintaining their nominal face dimensions with no projecting glass stops except where necessary in door transom lites. -400 series 1 3/4" (44.5) for stop glazing, additional glass stop dimension of 3/4" (19.0) must be added to nominal face dimension of framing. Construct framing from extrusions of size and shape as shown on shop drawings. All framing joints shall be accurately cut and machined to allow neat watertight connections with all extrusions. Framing systems shall be designed for either shear block or screw spline corner joinery. Duranar Fluoropolymer paint: AAMA 2605 Framing shall be installed, glazed and adjusted accordingly to the manufacturer's instructions and approved shop drawings. All items in this section shall be set level, square and plumb and at their correct location and alignment with 06/03

SLIDING DOOR C1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified herein. Drawings and specifications for work in this section are based upon DESA S1000 series sliding doors. Whenever alternative products are to be considered, submit supporting technical literature and samples for review and comparison by Consultant. Doors to fully comply with applicable standard specifications as typically referenced to the following requirement criteria: Air and water tightness, wind and other load resistance. their Weathering shall be elastomeric or wool pile and of size and density appropriate for their Construct door from extrusions of size and shape as shown on shop drawings, rails and stiles shall be porthole type extrusions. Corner joinery shall be accurately assembled with mechanical clip fasteners and deep penetration plug and fillet welds. Standard Bronze Anodizing: AA-M12C22A31 Duranar Fluoropolymer Paint: AAMA 2605 Hardware Hardware shall be the entrance manufacturers standard unless stated otherwise by the If alternative hardware is selected by consultant the required templates and physical hardware must be submitted for assembly and fabrication. Doors shall be installed, glazed and adjusted accordingly to the manufacturers instructions and approved shop drawings. All items in this section shall be set level, square and plumb and at their correct location and alignment with 03/10

WINDOW FRAMING D1 Windows can be divided into two classifications: fixed and operating : Fixed windows can be designed as punched openings or horizontal strip windows, with or without vertical and horizontal intermediate mullions. Operating windows are projected or side hinged and can be designed to open in or out. Operating windows are usually combined with fixed glazing areas and rather than attempt to achieve both the fixed and ventilating functions with one product, it is often beneficial to select a fixed window product with an operating insert vent at appropriate intervals. Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance and window frames as detailed on the drawings and specified herein. Drawings and specifications for work in this section are based upon DESA series framing system. (select type: 20 and/or 90, 115 series). Whenever alternative products are to be considered, submit supporting technical literature and samples for review and comparison by Consultant. Framing system to fully comply with applicable standard specifications as typically referenced to the following requirement criteria: Air and water tightness, wind and other load resistance. their Weathering shall be elastomeric or wool pile and of size and density appropriate for their -20 series 2 3/16" (56.2) depth thermally improved operating window framing system for sealed unit glazing.. -90 series 3 1/2" (89.0) depth thermally improved fixed window framing system for sealed unit glazing. -115 series 4 1/2" (114.0) depth thermally improved fixed window framing system for sealed unit glazing. Construct framing from extrusions of size and shape as shown on shop drawings. All framing joints shall be accurately cut and machined to allow neat watertight connections with all extrusions. Framing systems shall be designed for screw spline corner joinery. Duranar Fluoropolymer Paint: AAMA 2605 Framing shall be installed, glazed and adjusted accordingly to the manufacturer's instructions and approved shop drawings. All items in this section shall be set level, square and plumb and at their correct location and alignment with 02/05

CURTAIN WALL FRAMING E1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance and window frames as detailed on the drawings and specified herein. Drawings and specifications for work in this section are based upon DESA series framing system. (select type: 45 or 2500 series). Whenever alternative products are to be considered, submit supporting technical literature and samples for review and comparison by Consultant. Framing system to fully comply with applicable standard specifications as typically referenced to the following requirement criteria: Air and water tightness, wind and other load resistance. and workmanship provided under this section. suit their purpose and function. their intended function. Weathering shall be elastomeric or wool pile and of size and density appropriate for their Insulated back pans in column or spandrel areas shall be galvanized steel of 20 gauge thickness (or as specified to suit application) and have sealed corners. Insulation shall be AF530 (48kg/m (3 lb.) density) fibreglass 51mm (2") thick (or as specified to suit application). Securing of insulation into back-up panel shall be by impaling insulation onto welded pins with retaining discs. Any connections between the back-up panels and framing shall be caulked with high grade butyl sealant. -45 series 1 3/4" (45) wide thermally improved curtain wall framing for sealed unit glazing. -2500 series 2 1/2" (63.5) wide thermally improved curtain wall framing for sealed unit glazing Both systems offer vented horizontal mullion glazing pockets achieving full rain screen capabilities. Construct framing from tubular extruded sections of size and shape as shown on shop drawings. All framing joints shall be accurately cut and machined to allow neat watertight connections and be designed for shear block joinery with all extrusions. Vertical expansion joints shall be sleeved and sealed at meeting mullion ends. All structural anchors shall have 3 way adjustment with welding completed after curtain wall is aligned. Duranar Fluoropolymer paint: AAMA 2605 Framing shall be installed, glazed and adjusted accordingly to the manufacturer's instructions and approved shop drawings. All items in this section shall be set level, square and plumb and at their correct location and alignment with 03/10

SKYLIGHT FRAMING F1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum skylight systems as detailed on the drawings and specified herein. Drawings and specifications for work in this section are based upon DESA 6400 series framing system. Whenever alternative products are to be considered, submit supporting technical literature and samples for review and comparison by Consultant. Framing system to fully comply with applicable standard specifications as typically referenced to the following requirement criteria: Air and water tightness, wind and other load resistance. their Weathering shall be elastomeric of size and density appropriate for their -6400 series 2 1/2" (63.5) wide thermally improved skylight framing system for sealed unit glazing. This system incorporates gutters in the horizontal purlins and provides drainage channels that lead to exterior weep holes achieving full rain screen capabilities. Construct framing from extrusions of size and shape as shown on shop drawings. All framing joints shall be accurately cut and machined to allow neat watertight connections with all extrusions. Rafters and purlins within the system shall be designed with 1/2" vertical offset overlap joinery allowing moisture to enter the rafter drainage channels. Duranar Fluoropolymer Paint: AAMA 2605 Framing shall be installed, glazed and adjusted accordingly to the manufacturer's instructions and approved shop drawings. All items in this section shall be set level, square and plumb and at their correct location and alignment with 02/05