Automation Test Introduction

Similar documents
ACD MIS Supervisor Manual

Streamlining Data Management Workflow

ACD MIS SUPERVISOR S GUIDE

Using UPSMON-PRO Monitoring Software. Opening UPSMON-PRO Monitoring Software

HID Real-Time PCR Analysis Software v1.3

FIERY WORKFLOW SUITE. EFI Fiery Central Centralize Production. Optimize Capacity.

Asset Management. Visit us at: or call SCAN

Productivity. PPS Cart: PulseNet Production Systems. Powerful Tools for Better Performance

Sage 300 ERP Sage 300 ERP Intelligence Release Notes

Universal Time Clock. Paychex Online Payroll Export Program User Guide

Oracle Enterprise Manager

The latest version of the easytrx2-s includes a number of new WIFI functions which are not yet described in the manual.

Technical Documentation. EiVisu4. Version : 1.0 Issued :

Sage 100. Sage Payroll Services Getting Started Guide

Tivoli Workload Scheduler

User s Manual. KSV NIMA Dip Coaters

Agilent VEE Pro 9.0 & Agilent VEE Express 9.0

Universal Time Clock TM. QuickBooks Plug-in User Guide

Technical Information SupplyCare Enterprise SCE30B

Primary Test Manager TM. Testing and management software for medium- and high-voltage assets

How to Configure the Workflow Service and Design the Workflow Process Templates

Access control SENATORFX.NET. Quick Start Guide

Eco Products Development

Outline. 01 Terminal Overview: Page The Basics: Page Transactions: Page Settlements: Page Poynt.

SAP Business One for Universities

Sage 100 Direct Deposit. Getting Started Guide

TrackITSystem. Facility Manager Documentation Installation and User Guide

Winzer Corporation 1 Revision: 4.0

UPS Shipping Setup for Conveyorware

Welcome to the course on the initial configuration process of the Intercompany Integration solution.

PISO-CAN200-D/T PISO-CAN400-D/T DASYLab CAN Driver User s Manual

ConnectWise-Sage 50 Accounts User Guide

Achieve higher levels of productivity, profit and success with Fiery

Enterprise Call Recorder

Accelerate your wor k fl ow

Index. Sarah Critchley 2018 S. Critchley, Dynamics 365 CE Essentials,

ROYALE ONLINE USERGUIDE

Agilent VEE Pro 9.2 and Agilent VEE Express 9.2

FFH (FINAL FINISH HOST)

Remote AMD Operator Manual

Out-of-the-Box Pro Software

Integrated IP Console (IIC)

Featuring, Remote Systems Explorer, Integrated Debugger, Support for IBM i Service Entry Points

INTRODUCTION.4 System Requirements... 4 Specifications INSTALLATION 6 Installation of TransactionTracker Server and Client Application...

February 2017 Merchant Overview

Content Page. DHL MyBill Guide. DHL MyBill. DHL MYBILL INTRODUCTION 01 Content Page 02 What does DHL MyBill offer?

C191-E018A. Analytical Network Data System Compliant with ER/ES Regulations Progress Configuration of LabSolutions System.

Introducing FUJITSU Software Systemwalker Centric Manager V15.0

DS-200 THE NEW STANDARD IN MAIL CENTER EFFICIENCY High processing speed and quick job change over make your envelope handling more efficient

ICP Expert software. Technical Overview. Introduction

CMS Server V6 Installation User Manual Edition: EN

Invoices 3.3 User Guide

INOView. Safety at a glance. Sicherheitstechnik GmbH

NTT DATA RPA, Office Robot NTT DATA Corporation RPA Solution Section 2, Public Division 4 Public Sector 2

DATA SHEET. RF Overlay NMS. Network Management System RF OVERLAY NMS. Overview. Manageable Equipment. Functional Features.

HIGH-PERFORMANCE SOFTWARE SOLUTIONS FOR YOUR BUSINESS. IT S IN THE DETAILS. PRINTERS AND SCANNERS SOFTWARE SOLUTIONS

Alcatel-Lucent OmniVista 2500 NMS C for Network on Demand Service Multi-tenant Network Management

A crash course in Microsoft 365 Business. Achieve more in your business with an integrated security, management and productivity solution all in one.

What s new in Sinter Software version 6.1 Customer Information Bulletin

A crash course in Microsoft 365 Business. Achieve more in your business with an integrated security, management and productivity solution all in one.

ServicePRO + PartsPRO User Guide

Bar Scan tracks fixed assets in a cost effective manner using the latest handheld technology.

Audit Logging and Reporting

Agilent VEE Pro 9.2 and Agilent VEE Express 9.2

Using Waypoints with ProMark3

itemp Anywhere Wireless Sensors and Cellular Gateway User s Guide

Autodesk A360 Collaboration for Revit (C4R) and BIM 360 Team Whitepaper

Fast Track SA 2.0 Drive Thru Timing System. Document: USR-FTSA, Rev. A Effective Date: September 6, 2017

WorkloadWisdom Storage performance analytics for comprehensive workload insight

We have attempted to make this manual as easy to read and navigate as possible. To that end, a few basic conventions will be used throughout.

Integrating PPC s SMART Practice Aids with Engagement CS (Best Practices)

Global Value 7. Productivity Suite for GammaVision. Optimizing Gamma Spectrometry Processes through Secure Data Management and Measurement Automation.

HOW INTEGRATION WORKS...3

SAP Solution Manager. Installation Guide

Cisco Workload Optimization Manager: Setup and Use Cases

QuickBooks 2011 What's New and Improved

infopia Co., Ltd GLUCO DIARY

Intelligent Sensors. Arc Gives You the Power to Connect

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

PREFACE 5 Introduction to InspectTech Software... 5

Scalability and High Performance with MicroStrategy 10

BMC Control-M Workload Change Manager

Agilent Quality Tool Online Help. Printable Version. Intelligent Test Software Solutions. ITFSS p January 2005

imvision System Manager Infrastructure Management Software

GS1 Data Source Healthcare. Web interface user manual for data recipients in healthcare

Agilent VEE Pro 9.0 and Agilent VEE Express 9.0 Data Sheet

Smart Communications for Small and Medium Business. UC Suite for UNIVERGE SV9100

Printed Documentation

The most efficient way to print, capture and distribute documents

X2-RCU (Robot Control Unit) BE-5132 User Guide V1.0

Oracle Hospitality Inventory Management Mobile Solutions. Installation and Configuration Guide

Contents OVERVIEW... 3

Intuit Field Service Management QuickStart Setup Guide

An introduction to MediaSales Traffic

Virtual Office. Auto-Attendant User Guide. Version

Cisco UCS CPA Workflows

Intelligent Sensors. Arc Gives You the Power to Connect

Introduction to PtMS IS - the Interactive Scheduler

Release 12.2 Beta Program

Apps4.Pro Planner Manager. Table of Contents

Transcription:

Product Introduction Automation Introduction Network Master Pro MT1000A

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 2

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 3

Proposal Outline (1/4) Issues during Commission ing 1. Varying Work Time and Results Quality Dependent on Technician s Experience Although experienced technicians are efficient, they are high cost. Inexperienced technicians are low cost, but their work efficiency is low, presenting a risk of increased total cost due to the need for retesting. Commissioning Increased cost: Reduced cost: Skilled Tech New Tech Work Procedure Work content understanding: Work accuracy: Work time: Work Procedure Good High Short Results Evaluation Results Evaluation Work Completion Work Completion Work content understanding: Poor Work accuracy: Low Work time: Long Work Errors Evaluation Errors Retesting Longer Work Time Issue: How to assure consistent quality irrespective of experience 4

Starting Proposal Outline (2/4) Confirming Connection Completing Issues during Commissioning s 2.Increasing Risk of Work Errors as Items increase Sometimes several tests are performed on each circuit. As the number of test items increases, time for work, such as confirming the procedure for each test, setting the measuring instruments, checking the connections, etc., increases too. On-site test setting work not only wastes time, but is also a cause of human errors. RFC 2544 Y.1564 Saving Results Evaluating Pass/Fail Creating Report Work Step Work Step Work Step Work Step Work Step Issue: Important issue is how to decrease the number of work procedures to cut work times and lower the risk of operation errors. 5

Proposal Outline (3/4) Issues at Commissioning s 3. Reducing work burden to minimize errors Automating testing not only lightens the technician s work burden but also assures consistent quality. New Anritsu Proposal Setting Equipment: Executing : Evaluating Results: Manual Manual Judgment by the technician Setting Equipment: Auto Executing : Auto Evaluating Results: Auto One-button automation Issue: Automating on-site testing work procedures prevents work and evaluation errors to reduce the retesting risk. 6

Automatic Manual Confirm Connection Select Scenario Confirm Connection Proposal Outline (4/4) Save Save Issues at Commissioning s 4. Anritsu s Automated testing cuts timing time Start Op Setting RFC2544 Pass/ Fail Save Create Report Op Setting Y.1564 Pass/ Fail Save Create Report Complete Repetitive tasks: Set,, Evaluate, Create report Prepare Confirm Connection Start App Pass Create Start Pass Create Set Set Finish /Fail Report App /Fail Report Start RFC 2544 Y.1564 Automatic Execution Complete Prepare Confirm Connection Automatic Execution Select Finish Shorter Time Select one file Technician waits for test result 7

Product Introduction (1/2) Network Master Pro MT1000A Full range of Transport, OTDR and CPRI RF modules Supports optical mobile backhaul, fronthaul, metro and core networks Upgradeable structure to support to future network requirements Highly efficiency for large-capacity core and metro I&M Automated measurement functions simplifying work processes Network Master Pro MT1000A MU100010A: 10G Multi-rate Module MU10002xA: OTDR Module MU100040A: CPRI RF Module MU100090A: High Performance GPS Disciplined Oscillator Full Carrier Ethernet Installation and Troubleshooting Functions (RFC6349, RFC2544, ITU-T Y.1564, Ethernet OAM, Multi-Stream, BERT etc.) Synchronous Ethernet ing & Analysis Time Synchronization ing using PTP CPRI/OBSAI Fronthaul testing Optical Fiber ing (OTDR, PM, LS, VIP) CPRI RF testing of Spectrum and Spectrograph WLAN, Bluetooth connectivity Report Creation in multiple formats PDF, XML and CSV 8

Product Introduction (2/2) Scenario Environment Editing Kit (SEEK) MX100003A Free tool for creating automatic test scenarios for use on the MT1000A scenarios are created using the PC SEEK GUI with drag and drop operations Command Selection The MT1000A/MT1100A command functions are listed as icons here to create the test scenario using drag and drop operations. Command Details Comments, such as cable connection, test notes, etc., can be displayed here. Parameter input is also supported. Scenario Creation Area The scenario is created here by dragging icons from the command list into a series. Many areas are able to be configured, Instrument settings, Messages to the instrument user, Pass/Fail evaluation, file saving method, etc. Note: MU100040A function is not supported, yet. 9

Work Flow Step 1 Create/update measurement scenario Office Manage measurement reports Report (pdf) WireShark (pcap) Results file Measurement logs Field Step 2 Load measurement scenario into measuring instrument Measurement scenario file loading procedure USB Memory USB Cable LAN/WLAN Step 3 Perform automatic on-site measurement Scenario parameters can be edited on-site 10

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 11

Example 1: Multiple Communications Check 10G Ethernet Communications Check The MT1000A is connected to the circuit to be measured Scenario is run on both the local and remote sides Measurements are completed on Throughput, Frame Loss, Delay etc. On-site technician completes tests without the requirement to configure: Network Addresses, Configuration Settings, Pass/Fail thresholds etc. MT1000A Local Unit MT1000A Remote Unit 12

Example 2: Optical Fiber Check Measuring Multiple Optical Fibers with an OTDR Per site optical fiber testing requires different evaluation values, depending on the network requirements The technician is required to set reference values for each site The measurement conditions and reference values for each site and fiber can be pre-set in a scenario file The field technician simply executes the MT1000A SEEK one button test manual A manual B 13

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 14

Automatic Measurement Workflow Step 1 Create/update measurement scenario Office Manage measurement reports Report (pdf) WireShark (pcap) Results file Measurement logs Field Step 2 Load measurement scenario into measuring instrument Measurement scenario file loading procedure USB Memory USB Cable LAN/WLAN Step 3 Perform automatic on-site measurement Scenario parameters can be edited on-site 15

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 16

Office Work (1/10) Introduction A scenario file is created based on predetermined test contents to be executed on-site Displayed message dialogs reduce the technicians workload and shorten the overall test work time The following items are required to create an automated test scenario for the MT1000A which can be downloaded from the Anritsu website Scenario Environment Editing Kit (SEEK) MX100003A (free software) SEEK Sample Scenarios Instruction manual for MX100003A MT1000A/MT1100A SEEK Scenario Creation Method Search Anritsu Website for MT1000A and click [Download] Windows PC Connection between PC and MT1000A (USB cable, Ethernet connection, etc Downloaded and install the software to a PC Refer to the Instruction Manual for the installation method. 17

Office Work (2/10) Measurement modules, scenario icons, report file name, etc., are configured here. The scenario can be created with the tester connected allowing editing and confirmation of actual operation The report name and whether or not to use a timestamp can be set as a single action. User selectable logo can be inserted into the PDF report MT1000A Display Choose the main frame and module configuration to use The file names and icons displayed at the MT1000A are configurable along with a password if required. 18

Office Work (3/10) Information required for each procedure, parameters, Pass/Fail etc., can be adjusted and visualized here Each Application and operation is dragged and dropped into the Command Sequence. The Command Selection can be added within the visual procedure 19

Office Work (4/10) Explanation of Commands The following commands can be set by each application and are executed in accordance to their sequence Command Load Settings Message Start Measure Stop Measure Request Execute Evaluate Save Use Loads settings file specified by application into scenario The settings file can also be loaded after starting the application. Displays screen message dialog Starts measurement Stops measurement Displays dialog requesting input of a defined value Sets MAC and IP address and sets processing contents Sets Pass/Fail processing contents for test results Outputs test log report, saves results for each application, and executes report output 20

Office Work (5/10) The details for each command are set. The detailed contents are different for each application and command. The test procedure can be expressed in concrete terms by message commands. Images can also be displayed if necessary. 21

Office Work (6/10) Settings files not loaded previously can be edited directly by selecting [Load Settings] for OTDR. 22

Office Work (7/10) The following operations can be executed via [Execute]. OTDR: Insert script or SCPI commands Transport: Specify MAC and IP and Insert script or SCPI commands Transport:Address setting Common: Execution script setup Common: Execution SCPI setup 23

Office Work (8/10) The test is executed by [Start Measure]. Command details can differ with different applications The test is stopped by [Stop Measure]. (There are no command details.) Command details The contents change for each application 24

Office Work (9/10) In addition to displaying the MT1000A test results, [Evaluate] can be used to set any evaluation value Common: result display Common: Judgment script setup Common: Judgment SCPI setup 25

Office Work (10/10) [Save] sets the saved file name. There are also options to append a timestamp to the file name and create a report 26

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 27

Registering Scenario (1/2) 1. Power-up MT1000A 2. Move to Utilities screen 3. Start Scenario Mgr. 4. Select and load created measurement scenario Measurement scenarios are loaded using either USB memory, USB cable, or via LAN 2 Measurement scenario file loading procedure USB Memory USB Cable LAN/WLAN 3 4 28

Registering Scenario (2/2) The MT1000A Utility screen can also be used to confirm the test scenario icon registration Icon of loaded measurement scenario 29

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 30

Select Scenario Confirm Connection Field Work (1/7) RFC2544 Y.1564 Start Op Setting Pass/ Fail Save Create Report Op Setting Pass/ Fail Save Create Report Complete Automatic Execution 1. Power-up the MT1000A. 2. Select test scenario starting automatic measurement No other settings required Start scenario to perform automatic measurement. 31

Select Scenario Confirm Connection Field Work (2/7) Start Op Setting RFC2544 Pass/ Fail Save Create Report Op Setting Y.1564 Pass/ Fail Automatic Execution Save Create Report Complete 3. Confirm cables, connections and pre-test items as per MT1000A screen images Connection details displayed on screen Notice: Connection cable Please insert an optical cable in the port number 1 of a measuring instrument. 32

Select Scenario Confirm Connection Field Work (3/7) Start Op Setting RFC2544 Pass/ Fail Save Create Report Op Setting Y.1564 Pass/ Fail Automatic Execution Save Create Report Complete 4. Warnings are displayed before testing starts, if the connection cannot be confirmed or the addresses are incorrect testing will not continue Automatic judging of the link status 33

Select Scenario Confirm Connection Field Work (4/7) RFC2544 Y.1564 Start Op Setting Pass/ Fail Save Create Report Op Setting Pass/ Fail Save Create Report Complete Automatic Execution 5. MAC and IP addresses can be changed, parameter inputs can be specified. Work errors are eliminated as the technician only inputs required information once. The test progress status can be confirmed via the real-time log Input of Source Address status log Parameter can be changed at pop-up menu during testing 34

Select Scenario Confirm Connection Field Work (5/7) RFC2544 Y.1564 Start Op Setting Pass/ Fail Save Create Report Op Setting Pass/ Fail Save Create Report Complete Automatic Execution 6. The [Pass/Fail] evaluation is displayed on-screen when the test completes. If the test is failed, the exact test failure point can be confirmed in the log Final results check (Green: Pass; Red: NG) 35

Select Scenario Confirm Connection Field Work (6/7) RFC2544 Y.1564 Start Op Setting Pass/ Fail Save Create Report Op Setting Pass/ Fail Save Create Report Complete Automatic Execution As test results are saved automatically on the unit securely, they can easily be confirm. Additionally, a new folder is created for each SEEK test holding the results, this prevents any confusion when managing results files 36

Select Scenario Confirm Connection Field Work (7/7) RFC2544 Y.1564 Start Op Setting Pass/ Fail Save Create Report Op Setting Pass/ Fail Save Create Report Complete Automatic Execution Post-test report is saved in the same folder, as results are able to be saved in PDF format, there is no requirement to edit the report 2016xxxx_test1 37

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 38

Operating Environment and Procurement SEEK software PC requirements CPU: Intel Core i5 @2.4 GHz or better, Memory: 4 GB or better, HDD: 200 GB Hard drive or better, OS: Windows7 Professional 32/64-bit (SP1) Windows8 32/64-bit Windows8.1 32/64-bit Interface: Ethernet (10/100/1000 Mbps) or WLAN or USB MT1000A requirements Version v7.02 or later Procurement Software: https://www.anritsu.com/en-au/testmeasurement/support/downloads/software/dwl17488 Sample Scenarios: https://www.anritsu.com/en-au/testmeasurement/support/downloads/software/dwl17512 39

Proposal Outline Product Introduction Work Flow Application Examples Automation Steps Step 1: Office Work Step 2: Registering Scenario Step 3: Field Work Operating Environment and Procurement Summary 40 40

Summary Automation of commissioning tests shortens test times and cuts costs Reduces Field Technician Workload Automated testing with measuring instrument which eliminates re-work while on-site Simplification enables less experienced technicians to achieve the same level of accuracy as experienced technicians Shortens Times Reduces workload by automation of configuration and saving settings and results for each test On-the-spot evaluation ensures decision to re-test upon a result failure can be completed with full confidence Automated testing using the MT1000A unifies work flows and cuts field work costs 41

2017-2 MG No. MT1000A_Autotest-E-L-1-(1.00)