RainBarrier Installation Guide

Similar documents
SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

SECTION CEMENTITIOUS SHEATHING

RAINBARRIER CONTINUOUS INSULATION GUIDE STANDARDS AND CODE COMPLIANCE INSTALLATION ATTACHMENT

R-Matte Plus-3: Insulation for the Building Envelope

Fastener Guidelines. Issued: 2015 Technical Communication - Fastener Guidelines DESIGN BASIS

Construction Standards PAGE

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

Break it, or Lose it: Thermal Bridging in Building Envelopes

Cladding Attachment Through Exterior Insulation Using Long Screws PHIUS 10 TH ANNUAL NAPHC, CHICAGO COLIN SHANE M.ENG, P.ENG 11 SEPTEMBER 2015

Construction Standards PAGE

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

EXTERIOR WALLS. exterior wall systems, cladding w/ masonry. chapters SUBJECT

Henry NFPA 285 Air Barrier Assemblies

SECTION INSULATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

SRP-AirOutshield UV Issued:

EcoTouch Insulation with PureFiber Technology

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Concrete Soffit Direct Fix

Addendum to Specifications

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

calibrated gas flows from the room burner.

Cladding Attachment and Support

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Insulated Composite Panels Designed for Brick Back-up

SPECIFICATION GUIDELINE

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Ultra Wall System. CAD Detail Sets

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS

NFPA 285 Assemblies. Table of Contents

Gold Bond BRAND Gypsum Sheathing

KNIGHT WALL SYSTEMS GUIDE DETAILS:

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

O82018 Hunter Panels XCI Foil

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

[Project Name] Section [ ]

SECTION GYPSUM BOARD PART 1 - GENERAL

COMPLE TE RAINSCREEN WALL SYSTEMS

Thermal Performance of Northern Facades ISO Clip System Summary

MASONRY ANCHORS AND CONNECTORS May 6, 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

I-STUD Shaftwall System

Thermafiber RainBarrier T Continuous Insulation (ci)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

Contents. ZIP System R-Sheathing

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

NFPA 285 Assemblies. Table of Contents

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

NFPA 285 Compliant Wall Systems and Assemblies

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation

Planning and installation instructions

GAF EnergyGuard Polyiso Wall Sheathing

Optima Vector Plank. Installation Instructions. Ceiling

OPTIMA Vector Plank Installation Instructions

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Installation Procedures for the Ultra Air Barrier Wall System

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

New Veneers Allow Greater Flexibility

Duct Wrap Flexible Wraps

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

Attaching Cladding with Long Screws. Presented by: Michael Aoki-Kramer LEED AP

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax:

SECTION HVAC INSULATION

Installation Guide Wall Panels

STONE TYPE AND CURTAIN WALL VERTICAL MULLIONS JOSE L. CABRERA ARCH2431 PROF. PAUL KING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

Sheathing Board Xtra protection, built in.

Hunter Xci Polyiso Installation Guide

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION STRUCTURAL INSULATED PANELS

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

AIA Disclaimer Notice

The Role of Control Layers in Building Enclosure Design

CONCRETE MASONRY VENEERS TEK 3-6C

RESILIENT SOUND ISOLATION CLIPS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION 07 SECTION 2100 Short Form Guide Specification THERMAL, AIR BARRIER AND WATER BARRIER WALL SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

Professional Educational Series BSP716 USGBC # Commercial Building Science Thermal Control in Building Envelopes

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation

Transcription:

Installation Guide Installation Instructions for: > / Impasse Hanger Attachment > / Attachment > Brick Tie/Masonry Anchor Installation > Installation within -Type Framing > Installation

Installation Guide 2 2 Impasse Hangers/ Panel 45 & HD Thickness Width* Length* 1 to 4 16, 24 and 36 48, 36 and 60 *Custom sizes available Impasse Hanger Installation with Vertical 2 Impasse Hanger Installation with Horizontal + Metal Cladding Applications + Open Face Architectural Panels is installed between the exterior gypsum wallboard and façade channels creating a friction fit. Additional pins can be mechanically attached to secure the panel.

Air/Vapor Barrier + CMU/Brick Veneer Wall Tie Application + Steel Stud/ Brick Veneer Wall Tie Application Attachment to typical wall ties can either be impaled onto shelf-type wall ties or installed so wall ties occur at insulation seams. Wall ties typically occur every 16 oc. is then secured to wall tie with Clip. * Please note that for systems requiring fire performance characteristics, galvanized steel retaining clips are recommended. Clip Attachment to shelf-type wall ties can either be impaled onto shelf-type wall ties or installed so wall ties occur at insulation seams. Wall ties typically occur every 16 oc. is then secured to wall tie with Clip * Please note that for systems requiring fire performance characteristics, galvanized steel retaining clips are recommended. Clip Attachment to Brick-Veneer anchor wall to be attached to CMU wall with brick tie wall anchors. is secured to CMU wall by screwing the anchor screw with minimum 1 ½ diameter head to the CMU anchor. Screws are typically spaced every 16 oc. Brick Veneer Anchor

2 s/ Panel 45 & HD Installation with Horizontal 1 to 3 16 48 1 to 2 24 48 1 36 48 or 60 Impaing Pin Installation with Vertical 3 s/ Panel 45 & HD 3-1/2 to 4 16 48 3 to 4 24 48 1-1/2 to 4 36 48 1-1/2 to 4 36 60

4 s/ Panel 45 & HD 1 to 4 16 48 1 to 3 24 48 5 s/ Panel 45 & HD 4 24 48 6 s/ Panel 45 & HD 1 to 4 36 48 1 to 4 36 60 offers industry leading technical and engineering assistance to architects, specifiers, and contractors. These services include CAD drawings, engineering judgments, LEED Credit Information, and product recommendations. All consultative services are free. We protect your building by customizing our five-step approach: 1. All-Phase Consultation 2. High-Performance Products 3. Cost-Saving Hanger Systems 4. Labor-Saving Customization and Packaging 5. Safe & Sustainable

1. Mechanical Attachment Mechanical fasteners should be inset 2 in from edge of insulation. Rainscreen and cavity wall systems vary greatly from types of hangers and how they are installed. Contact Technical Services for further installation recommendations not addressed in this installation guide. 2. Moisture Absorption absorbs less than 0.03% by volume when tested per ASTM C 1104. 3. Vapor/Air Barrier Vapor retarder, air barriers and moisture control are elements that are essential to the proper design and construction of buildings. The need for and proper placement of the vapor/ air barrier and moisture control must be determined by a qualified professional engineer/architect knowledgeable of the climatic conditions both inside and outside, involved in the construction of each specific building. Penetrating the vapor/air barrier with mechanical insulation pins must be approved by the air/vapor barrier manufacturer. 4. Corrosion Resistance is non-corrosive per ASTM C 665. 5. R-value 45 & HD have an R-Value of 4.2/inch. R-value does not diminish over the life of the insulation. 6. UV Exposure itself is UV resistant. Please note that packaging is not UV resistant and storing outside may cause packaging to deteriorate overtime. 7. Delivery and Storage of Materials All materials delivered in their original packages and stored in an enclosed shelter providing protection from damage and exposure to the elements. Damaged or deteriorated materials shall be removed from the premises. 8. Cutting Material cuts easily with a serrated knife. 9. PPE Contact with mineral wool may cause temporary eye and skin irritation (mechanical). Wear eye protection and long-sleeved, loose fitting clothing closed at the neck and wrists while working with this product to avoid irritation. See Bonded MSDS for more information. LEED v2009 Green Building Credits Minimum 70% Recycled Content 1 Energy & Atmosphere Materials & Resources Indoor Environmental Quality Innovation in Design 1 2.1, 2.2 9 1 3.1, 3.2 4.1, 4.2 5.1, 5.2 3711 Mill Street Wabash, IN 46992 888-TFIBER1 [834-2371] [260] 563-2111 www.thermafiber.com TF522/02-14 Copyright 2014,, Inc. All Rights Reserved LEED is a registered trademark of U.S. Green Building Council