Client: Address: Property Description: (3) story townhouse Property age/ size: 2,781 s.f., built 2007 per listing Occupancy Status: Vacant

Similar documents
Client: Address: Inspection Date: 07/31/2011 Inspection Time: 10:00 A.M. 12:30 P.M. Weather Conditions: Overcast, 65 deg F +-

Property Description: (2) story townhouse style condominium Property age/ size: 1,600 s.f., built 2004 per listing Occupancy Status: Vacant

Property Description: (2) story single family home (daylight style) Property age/ size: Built 1974, 2,308 s.f. per listing Occupancy Status: Occupied

Client: Address: Inspection Date: 12/26/2011 Inspection Time: 9:00 A.M. 12:00 P.M. Weather Conditions: Overcast, 50 deg F +-

Inspection Date: 07/13/2011 Inspection Time: 3:30 P.M. 6:30 P.M. Weather Conditions: Scattered Clouds, 65 deg F +-

Inspection Date: 11/12/2011 Inspection Time: 1:00.M. 3:50 P.M. +- Weather Conditions: Heavy rain and wind, 37 deg F +-

Inspection Report. Property Address:

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

Alabama Home Inspections

The Inspector. Property Inspection Report

Madison's Home Inspections

Inspect Hawaii. Property Inspection Report

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

3D Home Improvement and Inspection Services, Inc

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Inspection Report. 1 of 8

1234 Main St. Buyer Name. Table of Contents

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Home Inspection Report

SUMMARY 1234 Main St.Severn Buyer Name 02/20/2018 9:00AM

component was performing its intended function; installation and condition were appropriate for age and use.

Capstone Inspection Services LLC

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Pre-Listing Home Inspection Checklist

Rental Inspection Checklist

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

Total Home Inspection Checklist

Property Inspection Checklist

REHABILITATION WORK WRITE-UP. Physical Address: Administrator: Grantee:

Pinnacle Home Inspections, Inc. Serving Central Arkansas

Accurate Inspections Inc. Property Inspection Report

Report Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID:

All Pro Home Inspection. Home Report North Your Town

Friendly Inspection Services

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

1st Defense Home Inspections, LLC

Hogue Home Inspections

J & M Solutions, LLC

Inspection Report. Property Address: 908 Black Hills Drive Spearfish, SD 57783

Home Condition Checklist

Friendly Inspection Services

Inspection Xpress. Property Inspection Report

1234 Main St Denver CO 80210

The Home Doctor, Inc.

Property Inspection Report

JBR Property Inspections

REPORT CHECKLIST SUPPLEMENT

RENTAL INSPECTION CHECKLIST. Helpful Definitions: Egress: the free and unobstructed access to the exterior of a habitable space.

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Home Inspection Checklist

City of New Hope Community Development 4401 Xylon Ave N New Hope MN Phone: Fax: newhopemn.gov

WEST MICHIGAN HOME INSPECTORS LLC 3134 Chamberlain SE Grand Rapids MI

Pacific Inspection Group Keaau-Pahaoa Rd Keaau, Hawaii Somewhere In Paradise Keaau, Hawaii 96749

Permit Posting and Inspection Procedures

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Z & C Construction, Inc. Subdivision:

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

SAMPLE Property Inspection Report

FINEGAN INSPECTION SERVICES, INC.

Property Inspection Report

Date of Inspection: April 30th 2006 Client: Ivan M. House Inspector: Lee Ottewell (CPBC License #: 47384)

Inspection Services of the Treasure Coast

New Jersey Home Inspection - Standards of Practice

Inspection Xpress. Property Inspection Report

GENERAL INFORMATION BUILDING INFORMATION ACRONYM RATING DEFINITIONS

Inspection Report. James Homeowner. Property Address: 123 Main St Paso Robles CA Murphree Building Inspections

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

Home Inspection Report South Sample Report Ave. - Boise Idaho

Woodard Inspections & Services, LLC

A 1 Professional Home Inspection 14 Brevoort Pl. Deer Park, NY Jamaica, NY 11434

Property Inspection Report

Walnut Creek Mutual Seventy

By YR Communities.

Tru-Quest Home Inspection

Property Inspection Report

My Home Was Built In What Can I Expect To See On My Report?

New Hope Inspections, LLC Property Inspection Report

Friendly Inspection Services

V.I. Inspections Page 1 of 15 21:04 September 18, 2018

Newberry. Foundation Framing

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Sample Home Inspection

Home Inspection Report

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

State Home Inspector Lic. # HI3986 Termite Inspector License # JE187661

Red Rock Home Inspections

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Checklist. Open House & Home Tour THE HOUSE. Flooring. Walls

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Anthracite Home Inspections

Home. Safe. Home. home inspection report

Integrity Home Inspection & Testing, LLC

SINGLE FAMILY HOME SPECIFICATIONS

HOUSING QUALITY STANDARDS (HQS) INSPECTIONS

Transcription:

(425) 652-6515 Kevin@Hergert.com Wa. Home Inspector 619 WSDA Inspector 79988 WSDA Control # 1196AQ-026 Client: Address: Property Description: (3) story townhouse Property age/ size: 2,781 s.f., built 2007 per listing Occupancy Status: Vacant Inspection Date: 08/29/2011 Inspection Time: 12:30 P.M. 3:50 P.M. Weather Conditions: Clear, 70 deg F +- Hergert Inspection LLC Kevin Hergert, Member Page 1 of 31

Table of Contents Summary of Inspection...3 Electrical System...5 Plumbing System...7 Water Heater...8 Heating System...10 Site...12 Building Exterior...14 Garage...17 Hallways and Foyer...18 Floor 1 Bedroom Suite...19 Kitchen...20 Living Room and Dining Room...22 Den...23 Utility Room...24 Powder Room...25 Master Bedroom Suite...26 Bedrooms 2 and 3...28 Main Bathroom...29 Structural Pest Inspection Diagram...31 Page 2 of 31

Summary of Inspection All items listed in the Summary of each section are listed below. Additional comments may be written in the body of the report. Please read the entire report. All items listed below should be further evaluated, inspected, modified, and/or corrected by a licensed professional in that corresponding or related trade. WDO refers to Wood Destroying Organism as defined by the Washington State Department of Agriculture - Items in this font are general comments throughout report. - Items in this font are considered minor cost and/or cosmetic. - Items in this font are considered an extreme safety concern or substantial cost. Electrical System - Electrical panel cover hinge missing - Question to Seller: What is the purpose of the unlabeled 50 amp breaker at the lower right corner of the panel; properly label panel Plumbing System Water Heater Heating System - Unable to operate furnace. Unable to properly operate thermostat. Recommend service of furnace and verify proper operation of entire heating and cooling system Site - Ground is saturated at S.E. corner of building. Possible solution would be an interceptor type drain. - Earth to wood contact at several area including deck posts. Ground should be 4-6 below wood - Vegetation in contact with structure (WDO conducive condition) - Evidence of settlement at side patio. Masonry veneer at post is not secure to patio (wobbles). Recommend fill voids with mortar and/or cultured stone Building Exterior - All roof areas should be cleaned of debris. Composition shingles should be treated for moss - Gutters and roof scuppers should be cleaned off all debris. Particular concern is gutter to left of garage that shows evidence of spillage onto siding below - Deck ledger should be lag bolted to structure to prevent separation of deck(s) from house - Barricades at all decks do not appear to meet code requirements. 36 high, no sphere greater than 4 can pass thru space - Substantial paint/finish deterioration at all deck rails; several areas not properly caulked to prevent moisture intrusion into barricade Garage Hallways and Foyer - Exterior lights inoperative. Recommend installation of new light bulbs as needed throughout house. Staircase light bulbs should be replaced with long life LED bulbs due to difficult access. All smoke detector batteries throughout should be replaced - Unable to retract deadbolt at foyer double door to patio - Door stop not installed at front door Floor 1 Bedroom Suite - Left sink valve is loose Page 3 of 31

Kitchen - Excessive gap at hardwood floor board in front of sink - Unable to turn burner knob for front right burner at cooktop - Leak beneath Kitchen sink - Debris in garbage disposal Living Room and Dining Room - Electrical outlet plate cover missing at Dining room - Window screens not installed Den - Window screens not installed - Latch for stationary door will not insert into strike plate Utility Room - Window screen not installed Powder Room - Sink values are not properly aligned Master Bedroom Suite - Light fixture appears to be installed upside down (likely will leave heat marks on ceiling) - Question to Seller: Brochure stated in floor heat. Where is this located? - Likely window seal failure at window above bathtub - (2) single hung window latches disconnected - Window screens not installed - Door to bedroom self closes, door to bathroom closet and walk in closet do not latch - Doorstop missing at door to deck - Deck door window trim (exterior) is not secure and/or properly installed - Re-caulk base of shower pan-wall - Tile repairs near tub valves was not completed in a workmanlike manner - Shower head will not stay in adjusted position - Gas value at fireplace will not turn. A secondary valve is located beneath the fireplace - Tub motor access not located (as required by code) Bedrooms 2 and 3 - Discoloration at closet of N.E. bedroom. Recommend re-paint and continue to monitor - Smoke detector for N.E bedroom fell off on test - Roller catch closet doors need adjustment at N.E. bedroom Main Bathroom - Light fixture appears to be installed upside down (likely will leave heat marks on ceiling) - Heat register cover missing at toe-kick - Bath fan runs very loud; needs adjustment - Towel bar not secure (fell off) to wall - Leak beneath right sink - Re-caulk inside corner of tub-shower wall and at tile near floor - Sink valves and spouts are not secure; left sink stop disconnected Page 4 of 31

Electrical System No evidence of over-heating (arc fault breakers shown in yellow run hotter than others) Service Type: Underground Meter Location: Side of garage Voltage: 240 Panel Location: Manufacturer: Type: Panel Rating: Main Disconnect: Serv. wire Size/ Rating: Sub-panel: Grounding: Panel Clearance: Garage Siemens - Electrical panel cover hinge missing Dual bus bar 200 AMP 200 AMP 200 AMP No Copper to exterior ground rod, limited visibility 30 wide, 3 in front as required Hinge missing at electrical panel Page 5 of 31

Breakers/ Wiring Type: Breakers: Copper romex - Question to Seller: What is the purpose of the unlabeled 50 amp breaker at the lower right corner of the panel; properly label panel Page 6 of 31

Plumbing System Domestic Water Supply: Supply Pipe: House Piping: Pipe Condition: Main Water Shut off: Public water Poly pipe where visible Copper where visible where visible @ garage Domestic Water Shut off Sanitary Sewer Discharge: House Piping: Pipe Condition: Public sewer ABS where visible where visible Page 7 of 31

Water Heater Water Heater Location: Garage Make/ Model: Rheem power vent RHLND407V0724 manufactured 04/2007 Fuel Type: Natural gas Capacity: 50 gallon Useful Life Est. Useful Life new: 12 years Est. age of heater: 5 years +- Safety TMP valve: Earthquake Straps: Expansion Tank: Flame Rollout: As per required Installed Installed No visible evidence Drip (primer) valve for TMP discharge into P trap Valve is to drip water to keep water in P trap to prevent sewer gases from escaping Page 8 of 31

Flue Secure: Clearances: Draft Hood: Inspected As required where visible n/a Power vent Water Temperature Safe water temperature: Measured temperature: 120 deg F per industry standards 124 deg F +- at Kitchen faucet Page 9 of 31

Heating System Furnace Location: Garage Make/ Model: Rheem classic 90 s/n FY5D702F440602018 manufactured 11/2006 Fuel Type: Natural gas BTUH: 60,000 Efficiency Rating: High-efficiency Exterior Compressor: Rheem s/n 7297M260726357 manufactured 06/2007 Useful Life Est. Useful Life new: 25 years Est. age of furnace: 5 years +- - Unable to operate furnace. Unable to properly operate thermostat. Recommend service of furnace and verify proper operation of entire heating and cooling system Heat Exchanger Visible Inspection: Gas detection test: Operation Thermostat: Combustion Air:, limited visibility No gas leak detected Programmable @ floor 2 hall Appears adequate Flue Secure: clearances: Inspected Per requirements where visible Page 10 of 31

Heat Gain Rating: @ return air: @ nearest register: 40-70 deg F - Not verified as heating system inoperable - Not verified as heating system inoperable Heat drop from cooling mode; approximately 14 deg F (normal) Temperature measured at return air Temperature measured at register Page 11 of 31

Site Site Grade at structure: Earth to wood contact: Vegetation contact: Roof drain discharge: - Marginal grade away at East area of South wall - Ground is saturated at S.E. corner of building. Possible solution would be an interceptor type drain. - Earth to wood contact at several area including deck posts. Ground should be 4-6 below wood - Vegetation in contact with structure (WDO conducive condition) Underground discharge Reverse grade to structure Ground in contact with wood Potential wood rot condition Vegetation in contact with structure WDO conducive condition Driveway Type: Condition: Trip Hazard: Concrete None Page 12 of 31

Front walks/ steps Type: Condition: Trip Hazard: Rear walks/ steps Type: Condition: Trip Hazard: Miscellaneous Overhead Power Lines: Retaining Walls: Underground Oil Tank: Irrigation System: Concrete None Concrete - Evidence of settlement at side patio. Masonry veneer at post is not secure to patio (wobbles). Recommend fill voids with mortar and/or cultured stone None N/A None that affect structure No visible evidence None visible Page 13 of 31

Building Exterior General Condition Structural Movement: Exterior doors: Windows (ext. cladding): Siding Type: Condition: Window/Door Flashing: Caulking: No visible evidence Hardboard, shingles, and cultures stone - Moisture stains at porch soffit in several areas. These appear to be related to construction. No other evidence of leakage found. Recommend continue to monitor Gap at N.E. patio pier See prior comment in Site section Roof Estimated Pitch: 9:12 +- and 2:12 +- Material: Composition and membrane Layers: 1+ How Inspected: From eave at (2) locations and from street and rear yard Condition: - All roof areas should be cleaned of debris. Composition shingles should be treated for moss Ventilation: Eave vent Plumbing Vents: Flues: Flashing: Page 14 of 31

Membrane roofing Scuppers need to be clear of debris Gutters/ Downspouts Type: Condition: Continuous metal - Gutters and roof scuppers should be cleaned off all debris. Particular concern is gutter to left of garage that shows evidence of spillage onto siding below Siding stain shows evidence of spillage Gutter above and left of garage Electrical Plumbing Outlets: Switches/Lights: Hose Bibs: Gas Piping:, GFCI protected Anti-siphon Inspected Page 15 of 31

Decks Structure: Decking: Condition: Connection to Structure: Trip Hazard: Barricades: Pressure treated joists Composite - Deck ledger should be lag bolted to structure to prevent separation of deck(s) from house None - Barricades at all decks do not appear to meet code requirements. 36 high, no sphere greater than 4 can pass thru space - Substantial paint/finish deterioration at all deck rails; several areas not properly caulked to prevent moisture intrusion into barricade No evidence of lag bolt connection of deck to house Rails do not appear to comply with code Substainial weathering of deck rails Gaps at posts at deck rail could lead to wood rot Page 16 of 31

Garage Type: Attached General Room Condition Visibility: Structural Movement: Moisture Infiltration: Walls: Ceiling: Slab: Safety Fire separation: Ignition point > above FF: Safety barricade to mech.: Garage Door Type: Springs & Fasteners: Auto Reverse: Photocell reverse: Remote openers: Space is vacant No visible evidence No visible evidence As required where visible In compliance Not needed Metal roll-up - Cosmetic dent at garage door Not present Electrical Doors Switches/Lights: Outlets: Operation/latching: Door condition: All visible tested, GFCI protected Page 17 of 31

Hallways and Foyer Location: Floors 1, 2, and 3 General Room Condition Visibility: Space is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Electrical Switches/Lights: Outlets: Smoke Detector: Heating Source: Air Flow/ Heat Gain: All visible tested - Exterior lights inoperative. Recommend installation of new light bulbs as needed throughout house. Staircase light bulbs should be replaced with long life LED bulbs due to difficult access. All smoke detector batteries throughout should be replaced All visible tested Ceiling register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Screen: Not required Doors/Millwork Operation/latching: Door condition: Millwork condition: - Unable to retract deadbolt at foyer double door to patio - Door stop not installed at front door Stairwell Handrails: Barricades: Balusters: Trip Hazard: As required As required As required None - Elevator not a part of this inspection Page 18 of 31

Floor 1 Bedroom Suite Location: Floor 1 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Mirrors: Electrical Switches/Lights: Outlets: Smoke detector: Heating Source: Air Flow/ Heat Gain: Mechanical ventilation: All visible tested All visible tested. Bathroom outlets are GFCI protected Ceiling register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Egress: Screen: As required Appears to meet current egress standards Doors/Millwork Operation/latching: Door condition: Millwork condition: Bath Hardware: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Toilet Secure: Tub/Shower surround: Fixtures: Appears adequate Appears adequate None visible - Left sink valve is loose Page 19 of 31

Kitchen Location: Floor 2 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: - Excessive gap at hardwood floor board in front of sink Cabinets: Countertops: Appliances Dishwasher: Dishwasher air gap: Oven: Cooktop: Microwave: Ventilation: Refrigerator: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Disposal: Caulking: Fixtures: full cycle Visible - Unable to turn burner knob for front right burner at cooktop Not tested Appears adequate Appears adequate - Leak beneath Kitchen sink - Debris in garbage disposal Leak at Kitchen sink Page 20 of 31

Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: All visible tested All visible tested, GFCI protected Floor register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Screen: Not required Doors/Millwork Operation/latching: Door condition: Millwork condition: Page 21 of 31

Living Room and Dining Room Location: Floor 2 General Room Condition Visibility: Rooms are vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: All visible tested All visible tested - Electrical outlet plate cover missing at Dining room Floor register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Screen: Not required - Window screens not installed Doors/Millwork Operation/latching: Door condition: Millwork condition: Fireplace Type: : Sealed gas direct vent Ignition tested - Batteries not installed at both fireplaces for ignition during power outage Page 22 of 31

Den Location: Floor 2 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Electrical Switches/Lights: Outlets: Smoke Detector: Heating Source: Air Flow/ Heat Gain: All visible tested All visible tested - Not tested Floor register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Egress: Screen: Not required Appears to meet current egress standards - Window screens not installed Doors/Millwork Operation/latching: Door condition: Millwork condition: - Latch for stationary door will not insert into strike plate Page 23 of 31

Utility Room Location: Floor 2 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: Mechanical ventilation: All visible tested All visible tested, GFCI protected Floor register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Screen: Not required - Window screen not installed Doors/Millwork Operation/latching: Door condition: Millwork condition: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Fixtures: Appears adequate Appears adequate None visible Page 24 of 31

Powder Room Location: Floor 2 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Mirrors: Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: Mechanical ventilation: Doors/Millwork Operation/latching: Door condition: Millwork condition: Bath Hardware: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Toilet Secure: Fixtures: All visible tested All visible tested, GFCI protected Floor register - Not verified as heating system inoperable Appears adequate Appears adequate None visible - Sink values are not properly aligned Page 25 of 31

Master Bedroom Suite Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Mirrors: Electrical Switches/Lights: Outlets: Smoke detector: - Light fixture appears to be installed upside down (likely will leave heat marks on ceiling) All visible tested. Bathroom outlets are GFCI protected - Reset in main bathroom Light fixtures face upwards close to ceiling Heating Source: Air Flow/ Heat Gain: Mechanical ventilation: Floor register - Not verified as heating system inoperable - Question to Seller: Brochure stated in floor heat. Where is this located? Page 26 of 31

Windows Glazing: Tempered: Operation: Egress: Screen: - Likely window seal failure at window above bathtub As required - (2) single hung window latches disconnected Appears to meet current egress standards - Window screens not installed Doors/Millwork Operation/latching: Door condition: Millwork condition: Bath Hardware: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Toilet Secure: Tub/Shower surround: Fixtures: - Door to bedroom self closes, door to bathroom closet and walk in closet do not latch - Doorstop missing at door to deck - Deck door window trim (exterior) is not secure and/or properly installed Appears adequate Appears adequate None visible - Re-caulk base of shower pan-wall - Tile repairs near tub valves was not completed in a workmanlike manner - Shower head will not stay in adjusted position - Gas value at fireplace will not turn. A secondary valve is located beneath the fireplace - Tub motor access not located (as required by code) Page 27 of 31

Bedrooms 2 and 3 Location: Floor 3 General Room Condition Visibility: Rooms are vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence - Discoloration at closet of N.E. bedroom. Recommend re-paint and continue to monitor Walls: Ceiling: Flooring: Electrical Switches/Lights: Outlets: Smoke Detector: Heating Source: Air Flow/ Heat Gain: All visible tested All visible tested - Smoke detector for N.E bedroom fell off on test Floor register - Not verified as heating system inoperable Windows Glazing: Tempered: Operation: Egress: Screen: Not required Appears to meet current egress standards Doors/Millwork Operation/latching: Door condition: Millwork condition: - Roller catch closet doors need adjustment at N.E. bedroom Page 28 of 31

Main Bathroom Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Mirrors: Electrical Switches/Lights: Heating Outlets: Source: Air Flow/ Heat Gain: Mechanical ventilation: All visible tested - Light fixture appears to be installed upside down (likely will leave heat marks on ceiling) All visible tested, GFCI protected Floor register - Heat register cover missing at toe-kick - Not verified as heating system inoperable - Bath fan runs very loud; needs adjustment Windows Glazing: Tempered: Operation: Screen: As required Doors/Millwork Operation/latching: Door condition: Millwork condition: Bath Hardware: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Toilet Secure: Tub/Shower surround: Fixtures: - Towel bar not secure (fell off) to wall Appears adequate Appears adequate - Leak beneath right sink - Re-caulk inside corner of tub-shower wall and at tile near floor - Sink valves and spouts are not secure; left sink stop disconnected Page 29 of 31

Leak at bathroom sink Page 30 of 31

Structural Pest Inspection Diagram Wood Destroying Organisms (WDO) Conducive Conditions (CC) WDO-AB Anobid Beetles CC-BG Bare Ground WDO-CA Carpenter Ants CC-CD Conducive Debris WDO-DT Dampwood Termites CC-EM Excessive Moisture WDO-MA Moisture Ants CC-EW Earth-Wood Contact WDO-OB Other Beetles CC-FC Failed Caulking WDO-RF Rot Fungus CC-IV Inadequate Ventilation WDO-ST Subterranean Termites CC-RG Restricted Gutter CC-VC Vegetation Contact Inspection Conditions (IC) IC-CSA Crawl Space Access IC-IA Inadequate Clearance CC-EM (saturated ground) CC-EW slab on grade CC-EW (deck posts) GARAGE CC-EW/VC DRAWING NOT INTENDED TO BE EXACT Page 31 of 31