Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Similar documents
Approved. This product is tintable in a wide range of colours in Jotun's Multicolor Decorative (MCD) system. Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

Protective: Recommended for refineries, power plants, bridges and buildings. Suitable for a wide range of industrial structures.

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 29 C IED (2010/75/EU) (calculated)

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong

Property Test/Standard Description

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 25 C calculated IED (2010/75/EU) (theoretical)

Marine: Outside hulls, exterior and interior areas, including water ballast tanks. Suitable for water ballast tanks at newbuilding stage.

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Property Test/Standard Description

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 32 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 30 C calculated VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description

General: Primarily designed for maintenance and repair. In immersed environments Jotamastic 80 Aluminium is suitable.

Property Test/Standard Description

Protective: Recommended as an internal lining for offshore, onshore and buried tanks and pipes. Refer to Protective Product Resistance List.

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test/Standard Description

Approved. Property Test/Standard Description. high gloss (85+) Flash point ISO 3679 Method 1 30 C. US EPA method 24 (tested)

Date of issue: 5 October 2017 Page: 1/6

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (30 C) calculated VOC-US/Hong Kong

Property Test/Standard Description. 53± 2 % matt (0-35) Flash point ISO 3679 Method 1 25 C calculated IED (2010/75/EU) (theoretical)

Protective: Recommended for offshore environments, refineries, power plants, bridges, buildings, mining equipment and general structural steel.

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (28 C) VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards.

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (33 C) calculated VOC-US/Hong Kong

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards. Property Test/Standard Description

Property Test/Standard Description Solids by volume. ISO 3233 Gloss level (60 ) ISO 2813

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 32 C calculated IED (2010/75/EU) (theoretical)

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 32 C VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 15 C IED (2010/75/EU) (calculated)

Property Test/Standard Description

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (32 C) calculated VOC-US/Hong Kong

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 14 C calculated VOC-US/Hong Kong US EPA Method (theoretical)

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Marine: Exterior and interior areas, including outside hulls, superstructures, decks, cargo holds and water ballast tanks.

Pre-qualification testing in accordance with NORSOK M-501, Rev. 3, System 7, suitable for splash zone. Property Test/Standard Description

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards.

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 35 C

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

General: Primarily designed for maintenance and repair. Only aluminium containing versions to be used in immersed environments.

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

Property Test/Standard Description STANDARD GRADE

Property Test/Standard Description STANDARD GRADE

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards. Property Test/Standard Description

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Approved. Marine: Exterior areas, specially designed for outside hull, may be used on superstructure, decks and other external areas.

Approved. Property Test/Standard Description STANDARD GRADE. semi gloss (35-70) Flash point ISO 3679 Method 1

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-USA / VOC Hong Kong EPA Method 24

Pre-qualification testing in accordance with NORSOK M-501, Rev. 3/4, System 7, suitable for splash zone. Property Test/Standard Description

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards. Property Test/Standard Description

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (35 C) VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description. 96± 2 % matt (0-35) Flash point ISO 3679 Method 1 34 C

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards. Property Test/Standard Description

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards.

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 22 g/l

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

Typically used in the oil, gas and energy industries. Suitable for both offshore and onshore environments.

Property Test/Standard Description. Flash point ISO 3679 Method C

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 14 g/l

Property Test/Standard Description Solids by volume. ISO 3233 Flash point ISO 3679 Method C

Property Test/Standard Description Solids by volume. ISO 3233 Flash point ISO 3679 Method 1 VOC-US/Hong Kong US EPA method 24 (tested)

Property Test/Standard Description. 98± 2 % gloss (70-85) Flash point ISO 3679 Method C calculated

Property Test/Standard Description. 98± 2 % gloss (70-85) Flash point ISO 3679 Method C

Technical Data Jotamastic 80 MIO

Technical Data Chemflake Special

Technical Data Baltoflake

The Application Guide offers product details and recommended practices for the use of the product.

Technical Data CHEMFLAKE SPECIAL

The Application Guide offers product details and recommended practices for the use of the product.

Technical Data CHEMFLAKE SPECIAL

The Application Guide offers product details and recommended practices for the use of the product.

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

^(ValidationDate) AE - BH - DZ - EG - KW - LY - MA - OM - QA - SA - TR Jotashield Tex Ultra

The Application Guide offers product details and recommended practices for the use of the product.

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

The Application Guide offers product details and recommended practices for the use of the product.

Transcription:

Approved 28780 1,2 28780 acrylic ^(ValidationDate) 2 Product description This is a one component water borne acrylic emulsion coating. It is a versatile, fast drying product for exterior and interior use. Dries down to 5 C. Ideal for new construction or maintenance where fast dry to handle and over coating times are required. Suitable as primer or mid coat in up to moderately corrosive environments. Suitable for properly prepared carbon steel, stainless steel, aluminium, galvanised steel, shopprimed steel, concrete and a range of aged coating surfaces. This product is part of a complete system which is certified not to spread surface flames. Typical use Protective: Recommended as primer or mid coat for a wide range of industrial structures e.g. airports, buildings, bridges, refineries, petrochemical and chemical plants, accommodation and working spaces. Marine: Recommended as primer or mid coat for accommodation and engine rooms. Other Approvals and certificates Contributes to satisfying the following credit(s) Indoor Environmental Quality (IEQ) under LEED 2009 Environmental Quality (EQ) and Materials and Resources (MR) under LEED v4 Meets VOC content requirements for BREEAM International and BREEAM Nor When used as part of an approved scheme, this material has the following certification: Low Flame Spread in accordance with EU Directive for Marine Equipment. Approved in accordance with parts 5 and 2 of Annex 1 of IMO 2010 FTP Code, or Parts 5 and 2 of Annex 1 of IMO FTPC when in compliance with IMO 2010 FTP Code Ch. 8 Consult your Jotun representative for details. Additional certificates and approvals may be available on request. Colours white, red, grey, grey XO Product data Property Test/Standard Description Solids by volume ISO 3233 46 ± 2 % Gloss level (GU 60 ) ISO 2813 matt (035) Flash point ISO 3679 Method 1 101 C Density calculated 1,3 kg/l VOCUS/Hong Kong US EPA method 24 (tested) 55 g/l VOCEU IED (2010/75/EU) (calculated) 47 g/l The provided data is typical for factory produced products, subject to slight variation depending on colour. Gloss description: According to Jotun Performance Coatings' definition. VOC in g/l (ISO 118902): 55 Date of issue: 2 January 2017 Page: 1/5

Film thickness per coat Typical recommended specification range Dry film thickness Wet film thickness Theoretical spreading rate 80 175 5,8 150 325 3,1 μm μm m²/l Surface preparation To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any contamination. Surface preparation summary table Surface preparation Substrate Minimum Recommended Carbon steel St 2 (ISO 85011) Sa 2½ (ISO 85011) Stainless steel Aluminium Galvanised steel Shop primed steel Coated surfaces Concrete Water jetting to cleanliness corresponding to the description of Wa 1 (ISO 85014) Water jetting to cleanliness corresponding to the description of Wa 1 (ISO 85014) The surface shall be clean, dry and appear with a rough and dull profile. Clean, dry and undamaged shop primer (ISO 129444 6.1) Clean, dry and undamaged compatible coating (ISO 129444 6.1) Low pressure water washing to a rough, clean, dry and laitance free surface. The surface shall be hand or machine abraded with nonmetallic abrasives or bonded fibre machine or hand abrasive pads to impart a scratch pattern to the surface and to remove all polish from the surface. The surface shall be hand or machine abraded with nonmetallic abrasives or bonded fibre machine or hand abrasive pads to impart a scratch pattern to the surface and to remove all polish from the surface. Light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern. Sa 2 (ISO 85011) P Sa 2½ (ISO 85012) Minimum 4 weeks curing. Moisture content maximum 5 %. Dry abrasive blast cleaning to SSPCSP 13/NACE No. 6. Application Application methods The product can be applied by Spray: Use air spray or airless spray. Date of issue: 2 January 2017 Page: 2/5

Brush: Roller: Recommended for stripe coating and small areas. Care must be taken to achieve the specified dry film thickness. May be used for small areas. Not recommended for first primer coat. Care must be taken to achieve the specified dry film thickness. Product mixing Single pack Thinner/Cleaning solvent Thinner: Water Guiding data for airless spray Nozzle tip (inch/1000): Pressure at nozzle (minimum): 1721 150 bar/2100 psi Drying and Curing time Substrate temperature 5 C 10 C 23 C 40 C Surface (touch) dry Walkondry 1 h 40 min 30 min 15 min 3 h 2 h 1 h 30 min Dry to over coat, minimum 3 h 2.5 h 1 h 1 h Drying and curing times are determined under controlled temperatures and relative humidity below 85 %, and at average of the DFT range for the product. Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal tackiness. Walkondry: Minimum time before the coating can tolerate normal foot traffic without permanent marks, imprints or other physical damage. Dry to over coat, minimum: The shortest time allowed before the next coat can be applied. Heat resistance Continuous Temperature Peak Dry, atmospheric 80 C The dry coating film will be gradually softer as temperature increases. Correct procedures for handling and stacking must be established, depending on environmental conditions. Protective properties will not be influenced. Ultimate dry film hardness will be reached later than the time stated for dried/cured for service. Suitable procedure for stacking of coated products must be considered, depending on environmental conditions. Date of issue: 2 January 2017 Page: 3/5

The temperatures listed relate to retention of protective properties. Aesthetic properties may suffer at these temperatures. Product compatibility Depending on the actual exposure of the coating system, various primers and topcoats can be used in combination with this product. Some examples are shown below. Contact Jotun for specific system recommendation. Previous coat: Subsequent coat: acrylic, epoxy shop primer, inorganic zinc shop primer, epoxy acrylic Packaging (typical) Volume (litres) Size of containers (litres) 20 20 The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary due to local regulations. Storage The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle with care. Protect from freezing at all times during storage and transport. Shelf life at 23 C 24 month(s) In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf life, thereafter the paint quality is subject to reinspection. Caution This product is for professional use only. The applicators and operators shall be trained, experienced and have the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical documentation. Applicators and operators shall use appropriate personal protection equipment when using this product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing the work. Health and safety Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately. Date of issue: 2 January 2017 Page: 4/5

Colour variation When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering. Disclaimer The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and practical experience. Jotun's products are considered as semifinished goods and as such, products are often used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves the right to change the given data without further notice. Users should always consult Jotun for specific guidance on the general suitability of this product for their needs and specific application practices. If there is any inconsistency between different language issues of this document, the English (United Kingdom) version will prevail. Date of issue: 2 January 2017 Page: 5/5