A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

Similar documents
GAS DETECTION SYSTEMS

Sensor unit MC2 for toxic gases and oxygen with analog output

Sensor Cartridge SC2 for toxic gases and oxygen

Sensor Cartridge SC2 for toxic gases and oxygen

INNOVA. Innova. Innova FV. Innova LS. Innova SV. Innova XT. Portable Gas Monitors For one, two, three or four gases. (Standard Multi Gas) (Fuel Vapor)

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

X-Change Gas Sensor Cartridges. PolyGard 2 SC2

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Crowcon Technical Note

Crowcon Technical Note

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

Technical Note TN-114 rev 16 wy/wh.11-04

SERIES 60 DETECTORS-TRANSMITTERS FOR FLAMMABLE, TOXIC GASES AND OXYGEN ATEX. Your environment, your safety, let s master them together

3M Meridian Sensor Specifications

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Online Gas Analyzer / Monitor

MLT 2 Multi-Component Gas Analyzer

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

MultiRAE Pro Monitors (Model PGM-6248)

SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases

SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

DR 1900 PORTABLE SPECTROPHOTOMETER

Cl500/Cl1000 BROCHURE

EQUIPMENT AND SERVICE COMPANY, INCORPORATED FX- 300 ISE Ammonia, Nitrate, Nitrite Measurement

Sensor Specifications and CroSS- Sensitivities

RESP_IRR_20 P Package

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.

Variable Area Flowmeters Model 28

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

DR1000 Flying Laboratory, Drone Environmental Monitoring

CANADA UNISEARCH founded in 1980

PRESSURE REGULATOR AND VALVE SELECTION GUIDE

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Waspmote Plug & Sense! Quick Overview

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

TEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions

Advanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis

COMBIMASS Thermal Gas Flow

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIA-G, DIS-G. Gas warning systems for Cl2, ClO2, O3, NH3, HCl

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Analyzer Module Wet Chemiluminescence Detection (WCLD)

Heated FID OVF Portable THC/TVOC Analyzer

SPECIFICATION SHEET FLUORIDE ION MONITOR SYSTEM CONFIGURATION. Model: FBM Fluoride Ion Monitor - Issue: FBM R1 Page 1

LEADERS IN PROCESS ANALYSIS AND CONTROL. Safety Solu ons. for Industrial Facili es

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

Vortex EX DELTA lowmeter Technical Specifications

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.

Lab Design or Renovation Plans Interview/ Review

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

???? Spot Check Measurement Simple, accurate, reliable

MultiRAE Pro Monitors (Model PGM-6248)

Royce Parts Per Million Dissolved Oxygen Systems. Water & Wastewater

3SP_CO_1000 Package

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

IMR E VIRO ME TAL EQUIPME T, I C. CATALOG

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Single-Use Sensors. Excellence in bioprocessing measurement. Data File #F808-DST-001-Rev2

Chloride/Sulfate Analyzer

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

QUICK START GUIDE. EVM Series Environmental Monitor

0.01 Micron Membrane Filters

SECTION Inline ULTRASONIC FLOW METERS

3SP_CO_1000 Package

Continuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers

madur GA21p-EN-v portable gas analyser

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors

Mobile Data Acquisition for Air Pollution Monitoring Using Embedded System

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Getting the most from your 4 gas monitor. Terri A. Pearce, PhD Emily R. T. Schmick, MSPH, CIH

F-2200 Series Steam Meter

Mass flow measurement without media contact

GAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES

MCBERNS ZC SERIES ODOUR FILTERS STANDARD SPECIFICATION

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

Draeger-Tubes and accuro Pump

MAX300-AIR PRODUCT NOTE. Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety. Environmental Mass Spectrometer

5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement

ECD Analytical. Your Liquid Measurement Expert. Industrial Water Analyzers and Liquid Analytical Products

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

Thermo Scientific Orion Dissolved Oxygen Probes

CH88 In Situ Flue Gas Oxygen Transmitter

Fpollutant-free zero air for analytical

PIOX S FLEXIM. No more corrosion and mechanical failures. Non-intrusive concentration, density and flow measurement of aggressive media

Sievers M9 TOC Analyzers

Process Total Organic Carbon Analyzer

H2scan Market Overview

Analysis O2, CO, CO2. Applications. Characteristics. System. Air monitoring. Measurands O 2, CO, CO 2. Measurement in liquids

Gas Analyzer Spare Part Recommendations

Transcription:

A World of Gases A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

ATI Presents A Simpler Approach To Toxic Gas Detection. One Transmitter Is All You Need. Time was, monitoring multiple gases meant using different gas transmitters each with its own maintenance problems, its own appetite for spare parts, its own installation headaches, and so on, and so on. Never again, thanks to ATI. Our UniSens universal 2-wire gas transmitter handles 28 different gases, providing the most economical and flexible gas measurement system available today. Combining universal electronics, bench calibration capability, automatic sensor verification, fault detection and alarming, and superior sensor technology, UniSens is your best transmitter choice. UniSens is designed for ambient gas monitoring in all kinds of industrial environments: gas storage areas, gas compressor rooms, process piping galleries, rail car sidings, analyzer shacks, gas cabinets, chemical process areas, and more. In fact, the UniSens transmitter can be used most anywhere that hazardous gas conditions might develop either through leakage or through natural buildup. Unsurpassed Features: Interchangeable Sensing Modules Auto-Test Sensor Verification Non-Intrusive Magnetic Controls 28 Different Gases Off-Site Calibration Integral LCD Display Output Simulation CSA Approved Intrinsically Safe & Explosion Proof

Smart Sensing Modules ATI sensing modules consist of an electrochemical gas diffusion sensor and a solid state memory assembly. Developed and manufactured exclusively by ATI, our electrochemical sensors provide excellent response time, maximum selectivity, and superior temperature stability for reliable gas sensing in a wide range of environments. The companion memory assembly stores operational information and calibration constants, along with gas sensor identification, sensing module range, and software revision level. Complete sensing modules are housed in convenient snap-in packages that mate easily with UniSens transmitters. This unique combination of sensor and memory lets you calibrate sensing modules with any UniSens transmitter. So instead of calibrating in the field, you can bench calibrate sensing modules with a spare transmitter; once the sensors are snapped into a field transmitter, their calibration constants upload automatically. Gas Standard Min/Max Range Range Ammonia* 0-100 PPM 50/500 PPM Carbon Monoxide* 0-100 PPM 50-500 PPM Hydrogen 0-4% 2000 PPM/10% Nitric Oxide 0-50 PPM 25/500 PPM Oxygen 0-25% 10/100% Phosgene 0-1 PPM 1/100 PPM Bromine* 0-1 PPM 1/100 PPM Chlorine 0-10 PPM 1/100 PPM Chloride Dioxide* 0-1 PPM 1/100 PPM Fluorine* 0-1 PPM 1/100 PPM Hydrogen Peroxide 0-10 PPM 10/100 PPM Iodine* 0-1 PPM 1/100 PPM Ozone* 0-1 PPM 1/100 PPM Hydrogen Chloride* 0-20 PPM 10/200 PPM Hydrogen Cyanide* 0-20 PPM 10/200 PPM Hydrogen Fluoride* 0-20 PPM 10/200 PPM Hydrogen Sulfide* 0-50 PPM 10/500 PPM Nitrogen Dioxide* 0-20 PPM 5/200 PPM Sulfur Dioxide* 0-20 PPM 10/200 PPM Arsine 0-1000 PPB 1000 PPB/100 PPM Diborane 0-1000 PPB 1000 PPB/100 PPM Germane 0-1000 PPB 1000 PPB/100 PPM Hydrogen Selenide 0-1000 PPB 1000 PPB/100 PPM Phosphine 0-1000 PPB 1000 PPB/100 PPM Silane 0-10 PPM 1000 PPB/100 PPM Acid Gases* 0-10 PPM 10/100 PPM Ethylene Oxide 0-20 PPM 20/200 PPM Formaldehyde 0-20 PPM 20/200 PPM Alcohol 0-500 PPM 500/2000 PPM * Indicates Auto-Test availability. Sensor Keeper Powered by an ordinary C cell, the Sensor Keeper maintains sensors in stable operating condition for up to 6 months. Sensor Keepers are useful not just for transporting sensors to and from the field, but for keeping calibrated spares on the shelf. They also let us calibrate sensors at the factory, and ship them for immediate installation and use.

Universal Transmitter Module The UniSens microcomputer-controlled transmitter provides a local digital display and a 4 20 ma analog output proportional to gas concentration. It works with any ATI sensing module, configuring its own display and output range automatically based on data read from the module s memory. Zero and calibration data is also read into memory, so the transmitter is automatically calibrated when it s connected to a calibrated module. Magnetic controls on the front of the transmitter allow field calibration, manual activation of the Auto-Test feature (if installed), and review of sensing module data including gas type, range, and number of successful Auto-Tests. The transmitter can also act as an analog output simulator to facilitate complete loop testing. Outputs of 4.0, 12.0, and 20.0 ma are selectable via the front panel, along with a trouble signal of 3.6 ma. The transmitter is housed in a durable castaluminum shell with an 11-pin octal base for easy installation and removal. And since UniSens transmitters are 100% interchangeable, one unit can serve as a backup for every type of gas in use. Auto-Test, for Savings and Safety. Until now, the manpower required for sensor testing has been the most expensive part of any toxic gas detection system. Available on many ATI sensing modules, our optional Auto-Test gas generator can cut testing costs dramatically by automatically verifying sensor response. It s a simple system. The Auto-Test gas generator is coupled to the end of the sensor as an integral part of the sensing module. Every 24 hours, the transmitter activates the generator and monitors the sensor for response. If the sensor responds properly, the system reverts to normal operation; if it fails, output is driven to 3.6 ma to signal trouble. (During testing, the output signal is held at the pre-test value.) The transmitter maintains a log of completed tests, and can display the time until the next scheduled test. An operator can manually activate Auto-Test, too. H 2 S Cl 2 CO SO 2 NH 3 H 2 Sensor Gas Generator

Typical Applications NH 3 CO H 2 S SO 2 Cl 2 O 2 H 2 HCl HF HCN NO NO 2 COCl 2 O 3 PH 3 H 2 O 2 Halogens Hydrides Chemical Processing Pulp & Paper R & D Labs Semiconductor Plants Refineries Pharmaceuticals Food Processing Aluminum Refining Breweries Metals Processing Water Treatment Wastewater Treatment Electric Utilities Agricultural Chemicals Plastics Manufacturing Specifications Gas Type: Customer-selected from available list Range: Supplied with standard range for each gas unless otherwise specified Display: 4-1/2 digit LCD Accuracy: Generally ±5% of value, but limited by available calibration gas accuracy Electronic Repeatability: ±1% Electronic Linearity: ±0.5% Zero drift: Sensor dependent, but generally less than 2% of full scale per month, non-cumulative Span drift: Application dependent, but generally less than 3% per month. Power: 12 30 VDC Output: Loop-powered 4-20 ma, 675 ohms maximum at 24 VDC Loop Simulation: Operator selectable outputs of 4, 12, 20, and 3.6 ma (trouble indictor) Enclosure: NEMA 4X and Explosion-proof cast aluminum, Class 1, Div. 1, Groups B, C, & D, CSA approved Controls: Magnetic controls activated externally through glass window Operating Temperature: -30 to +55 C (except oxygen, which is -10 to +55 C) Sensor: Modular plug-in unit with calibration data, gas type, and range in sensor memory Sensor Life: Average greater than two years Sensor Pressure Limits: 7 30 PSIA (05 2 Bar) Weight: 4 lbs. (1.8 Kg.) Accessories Splash Guard: Required for transmitters located outdoors or with Auto-Test, the clear polycarbonate splash guard provides protection against rain and high wind. Calibration Adapter: This fitting slides into the bottom of the splash guard and allows easy connection of zero air and span gas. Flowcell Assembly: For applications requiring sample draw systems, the flowcell seals the sensing module and permits the addition of inlet and outlet fittings to pipe sample into and out of the sensor. Splash Guard and Flowcell Assembly

How To Order Model A12-CC-DDDD-E-F UniSens Transmitter Suffix CC- Gas Type: *Indicates that Auto-Test is available for standard range. 10 Bromine 0-1 (10) PPM* 11 Chlorine 0-10 (100) PPM* 12 Chlorine Dioxide 0-1 (10) PPM* 13 Fluorine 0-1 (10) PPM* 14 Ozone 0-1 (10) PPM* 15 Ammonia 0-100 (500) PPM* 16 Carbon Monoxide 0-100 (500) PPM* 18 Hydrogen 0-2000 PPM (0-4%) 19 Oxygen 0-25% (0-100%) 20 Phosgene 0-1 (10) PPM 21 Hydrogen Chloride 0-20 (100) PPM* 22 Hydrogen Cyanide 0-20 (100) PPM* 23 Hydrogen Fluoride 0-20 (100) PPM* 24 Hydrogen Sulfide 0-50 (100) PPM* 25 Nitric Oxide 0-50 (500) PPM Suffix D Measurement Range 26 Nitrogen Dioxide 0-20 (100) PPM* 27 Sulfur Dioxide 0-20 (100) PPM* 28 Arsine 0-1000 PPB (0-10 PPM) 29 Diborane 0-1000 PPB (0-10 PPM) 30 Germane 0-1000 PPB (0-10 PPM) 31 Hydrogen Selenide 0-1000 PPB (0-10 PPM) 32 Phosphine 0-1000 PPB (0-10 PPM) 33 Silane 0-10 PPM (0-1000 PPB) 34 Hydrogen Peroxide 0-10 (100) PPM 35 Iodine 0-1 (10) PPM* 36 Acid Gases 0-10 (100) PPM 37 ETO 0-20 (0-200) PPM 38 Formaldehyde 0-20 (0-200) PPM 39 Alcohol: Contact factory Code the measurement range using a 4-digit number representing the full scale value. For 0 10 PPM chlorine, the code would be 0010. For 0 100 PPM ammonia, the code would be 0100. The standard ranges are shown under Suffix C above. An alternate range is shown in parentheses. There is no added price for the alternate ranges. Suffix E Units of Measurement 1 PPM 2 PPB 3 % 4 %LEL Suffix F Auto-Test Option 1 Sensor without Auto-Test Generator 2 Sensor with Auto-Test Generator (Requires Splash Guard #45-0047) Accessories 45-0047 Splash Guard (Required for Auto-Test) 00-0249 Flowcell Assembly 00-0210 Sensing Module Keeper 00-0248 Calibration Adapter (Requires 45-0047) Calibration Kits To insure accurate measurement, gas transmitters should be calibrated every 3-4 months. ATI offers convenient calibration kits that can be used for either bench or field calibration. Kits contain span gas, zero air, and a combination pressure and flow regulator in a molded plastic carrying case. Contact ATI for details on available kits. Represented By: Analytical Technology, Inc. 6 Iron Bridge Drive Collegeville, PA 19426 Phone: 610/917-0991 Toll-Free: 800/959-0299 Fax: 610/917-0992 E-Mail: sales@analyticaltechnology.com Web: www.analyticaltechnology.com ATI (UK) Limited Bank Chambers, 33 Stamford Street Mossley, Aston-u-Lyne OL5 0LL Phone: +44 (0) 1457 832800 Fax: +44 (0) 1457 83950 E-Mail: sales@atiuk.com