Spectroscopy Solutions for Pharmaceuticals:

Similar documents
GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

UV/Vis/NIR Certified Reference Materials

2018 by Agilent Technologies Agilent CrossLab Compliance Services

NEW. NIST Traceable UV/Vis/NIR Reference Sets USP 857

How Compliant and Efficient is Your Spectroscopy Workflow?

UV-Visible Spectrophotometer Calibration. S.ZALI M.Sc. Dept. of Analytical chemistry Razi vaccine serum research institute

The latest revision of European Pharmacopoeia to 5.2, and its effect on the Qualification of UV-Visible. Visible spectrophotometers

Using a Diode Array UV-Vis in Regulated Environments

Operational Qualification and Performance Verification of UV-visible Spectrophotometers. Technical Note. Agilent Technologies Innovating the HP Way

Seamless Method Transfer between the Agilent Cary 8454 UV- Visible Spectrophotometer and the 8453 UV-Visible Spectrophotometer

Certified Reference Materials for Spectroscopy

Starna. Certified Reference Materials for UV and Visible Spectroscopy. Starna

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Efficient. Accurate. Flexible. AGILENT CARY 60 UV-VIS SPECTRoPHOTOMETER

Thermo Scientific GENESYS 10S Bio spectrophotometer

Fluorescence & UV- Visible Workshop

ICP Expert software. Technical Overview. Introduction

Efficient. Accurate. Flexible. AGILENT CARY 60 UV-VIS SPECTRoPHOTOMETER

Cleaning Validation PRODUCT OVERVIEW

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

APPLICATION NOTE. Application Note. Summary/Abstract:

Starna. Certified Reference Materials for UV and Visible Spectroscopy. Starna

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Impact of Standardizing on Traceable QC for Volume Transfers Artel

Calibration in the Laboratory

Agilent 8453 Spectrophotometer and UV-visible ChemStation for Dissolution Testing. Solution Bundles for automated Dissolution Testing

VALIDATION OF CD SPECTROMETERS

UV/Vis Spectrophotometry. Time for New Demands SPECORD PLUS

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada.

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Genova Nano. Micro-volume Spectrophotometer

Flexible. Accurate. Intuitive. AGILENT CARY 100/300 SERIES UV-VIS SPECTRoPHOTOMETERS

Using Empower SystemsQT Qualification Tool

UV/VIS Spectrophotometers Excellence UV/VIS Spectrophotometers UV5Bio UV5Nano

Qualification of High-Performance Liquid Chromatography Systems

Just Prove it. Spectroquant Prove

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

Validation Strategies for Equipment from Multiple Vendors

Real-time tablet API analysis: a comparison of a palm-size NIR spectrometer to HPLC method

ICH Q2(R1) A Primer. cgmp. GxP PIC/S SOP ISO QA/QC LOD/LOQ. Validation of Analytical Methods API EP FDA OECD GCP

Just Prove it. Spectroquant Prove

METHOD 7550 OSMIUM (ATOMIC ABSORPTION, DIRECT ASPIRATION)

Spectrophotometer Service Solutions Comprehensive Service and Maintenance for Biochrom Spectrophotometers

Unrivaled. Sensitive. Flexible. Agilent Cary 600 Series FTIR

SpectraMax Multi-Mode Microplate Readers

solutions UV-visible spectroscopy for chemical analysis Agilent 8453 UV-visible spectrophotometer Our measure is your success.

Technical Procedure for Ultraviolet Spectroscopy

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Agilent TRS100 Raman. Quantitative Pharmaceutical Analysis System

SmartSpec Plus spectrophotometer

Analytical Procedures and Methods Validation for Drugs and Biologics

A Quality Control Procedure for the Agilent Bravo Platform

Essential MOLECULAR SPECTROSCOPY PAGES EDITION THE CHROMATOGRAPHY & SPECTROSCOPY CATALOG

Technical Procedure for Microspectrophotometry

Technical Procedure for Microspectrophotometry

Analytical Method Transfer Program. Richard B. Nguyen. Associate Scientific Liaison, Chemical Medicines, USP

Validation Strategies for Equipment from Multiple Vendors

CHEMICAL SOLUTIONS, Inc.

Compliance and qualification services. Trust your validation needs to the people who design, build, test, and support your systems

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

Fields of Application / Industry:

Comprehensive Service Options for Your Lab

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

á1225ñ VALIDATION OF COMPENDIAL PROCEDURES

The procurement, qualification and calibration of lab instruments: An Overview

FOUNDRY-MASTER Pro. First class laboratory optical emission spectrometer for complete professional metal analysisoes

Validation. An Easy to Understand Guide Validating Purified Water Systems

Process Analyzer Continuous Verification

QIAxpert Spectral Content Profiling Protocols

Flexible. Accurate. Intuitive. AGILENT CARY 100/300 SERIES UV-VIS SPECTRoPHOTOMETERS

The New Wave in Spectroscopy FS-2 FluoroMate Fluorescence Spectrometer

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

UV-visible spectroscopy solutions for chemical analysis

European Pharmacopoeia Reference Standards A Lodi, Head of the Laboratory Department, EDQM, Council of Europe

Services for Regulated Bioanalysis System Solution June 2012

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

Onsite quantitative FTIR analysis of water in turbine oil

Elisa Reader And Washer AT-2960R Washer

Guide to Fulfillment of Validation and Verification of Examination Requirements

Regulatory Expectations, Standards & Guidelines

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

2018 by Agilent Technologies Agilent CrossLab Compliance Services

Contents. Contents (13) 1 Production (23)

FT-IR. varian, inc. 660/670/680-IR.

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE.

Thermo Scientific Antaris II FT-NIR Analyzers

INTERAMERICAN METROLOGY SYSTEM (SIM 2

Lessons from Pharmaceutical Laboratory related FDA Warning Letters

Traceability and Standards Applied to Microtrac Instruments

Thermo Scientific Nicolet is20 FTIR Spectrometer

T100 T100+ Testing items: Portable spectrophotometer. COD Cr. (low concentration) (high concentration) Ammonia Chromium VI Cyanide COD

Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES

PLA Product Overview. PLA 2.1 Overview

Sample Quantitation. Protein Assay Kits 20. Spectrophotometry 23 Cuvettes 25

Agilent ChemStation for UV-visible Spectroscopy. Understanding Your UV-visible Spectroscopy System

Utilizing Glow Discharge in Optical Emission Spectroscopy

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23

Reference Standard Characterization. Steve Lane. General Manager, NSF Reference Standards.

Transcription:

Spectroscopy Solutions for Pharmaceuticals: Confidence in Compliance to USP <857> Using the Agilent Cary 60 UV-Vis Spectrophotometer White Paper Introduction UV-Vis spectroscopy is one of the most commonly used analytical techniques in clinical chemistry, pharmaceutical research, and quality control/quality assurance (QA/QC). Regulatory requirements for UV-Vis instruments used in these environments ensure that they are subject to design qualification (DQ), manufacturing quality control, lifecycle management, and installation/operational qualification (IQ/OQ), all of which can be demonstrated through the manufacturing quality records and equipment validation certification of the instrument manufacturer. Laboratory managers and administrators must set up appropriate controls on laboratory access, and ensure that system suitability tests (SSTs) and standard operating procedures (SOPs) are documented and followed. Commonly, the guidelines used to generate these tests and procedures are defined by global pharmacopeias including the USP and EP, all of which require that the performance of UV-Vis spectrophotometers is regularly verified.

The updated USP chapter <857> guides instrument validation protocols for UV-Vis spectroscopy. Table 1 outlines the main changes that have occurred, and this white paper outlines how to ensure that your instrument meets the performance criteria required using an Agilent Cary 60 UV-Vis spectrophotometer running on the updated, Windows 10 compatible Agilent Cary WinUV software. Performance Test Requirements According to USP Chapter <857> The automatic regulatory testing capabilities embedded within the Cary WinUV Validate application (provided with every Cary 60 UV-Vis spectrophotometer) deliver trusted reliability in the laboratory, and ensure that the instrument being used is suitable for its intended use as part of operational qualification (OQ). Agilent also offers a comprehensive portfolio of service plans and regulatory compliance services to help achieve validation of the Cary 60 UV-Vis spectrophotometer, software, and its components to ensure the highest levels of reliability and performance. The update to USP <857> describes important revisions to four main performance capabilities: Control of wavelengths (wavelength accuracy and precision) Control of absorbance (photometric accuracy and precision) Stray light Resolution The testing protocol for each of these, along with the details of the tests that are automatically run by the Cary WinUV Validate application, and examples of data from the Cary 60 UV-Vis spectrophotometer will be outlined in the following sections. To execute these tests, USP<857> recommends that the instrument performance be qualified over the intended operational range. This will vary according to the analytical protocol of different laboratories. In addition, USP<857> indicates that certified reference materials (CRMs) should be sourced from a credible supplier, such as Agilent, and should be recertified at regular intervals to maintain the validity of the certified values. Table 1. Updates to USP<857> for OQ of UV-Vis Spectrophotometers USP <857> Requirement What has changed? Agilent Cary WinUV software test protocol Control of wavelengths Control of absorbances New accuracy tolerances: 200 400 nm ±1 nm 400 700 nm ±2 nm New precision tolerances: < 0.5 nm standard deviation UV accuracy (potassium dichromate) new tolerances: < 1 Abs, < ±0.01 Abs > 1 Abs, < ±1 % Abs New precision test for UV (potassium dichromate): < 1 Abs, < ±0.005 Abs > 1 Abs, < ±0.5 % Abs Visible accuracy (NIST filters) new tolerances: < 1 Abs, < ±0.008 Abs > 1 Abs, < ±0.8 % Abs New precision test for visible (NIST filters): < 1 Abs, < ±0.005 Abs > 1 Abs, < ±0.5 % Abs Stray light Aqueous potassium chloride (12 g/l), tolerance < 1 %T %T at 198 nm reported Aqueous sodium iodide (10 g/l), tolerance < 0.05 %T* Acetone, tolerance < 1 %T Aqueous sodium nitrite (50 g/l), tolerance < 0.05 %T* At least six replicate measurements, reporting mean and standard deviation for each analysis wavelength. At least six replicate measurements, reporting standard deviation for each analysis wavelength. At least six replicate measurements, reporting standard deviation for each analysis wavelength. %T at 220 nm reported %T at 320 nm reported %T at 370 nm reported Resolution The USP now requires resolution to be measured (Toluene in Hexane, 0.02 % v/v) Ratio of absorbance at 269 and 266 nm *Cary 60 UV-Vis guaranteed specifications 2

Control of Wavelengths Wavelength accuracy The wavelength accuracy test is used to ensure that the wavelength axis of the UV-Vis spectrum is accurate (correct and within acceptable limits) across the intended operational range. It recommends use of atomic line spectra or rare earth oxides that yield well-characterized absorption bands, and enables the comparison of the UV-Vis spectrophotometer wavelength readings to published values. The analysis of rare earth oxides holmium perchlorate (from 200 600 nm) and didymium (from 700 860 nm), commonly available as CRMs, yields well-characterized peaks (Table 2) across the useable range of the UV-Vis spectrum. Table 2. Prescribed Wavelengths for the Determination of Wavelength Accuracy and Precision for Holmium Perchlorate and Didymium Holmium perchlorate (nm) 241.1 731.6 278.1 740.0 287.2 794.1 333.5 799.0 345.4 864.4 361.3 385.6 416.3 451.4 467.8 485.2 536.6 640.5 Didymium (nm) Absorbance 0.8 0.6 0.4 0.2 300 400 500 600 Wavelength (nm) Figure 1. Wavelength scan of holmium perchlorate using an Agilent Cary 60 UV-Vis spectrophotometer and Agilent Cary WinUV software. Absorbance 1.5 1.0 0.5 0 Figure 2. 700 750 800 850 Wavelength (nm) Wavelength scan of didymium using an Agilent Cary 60 UV-Vis spectrophotometer and Agilent Cary WinUV software. Wavelength precision The wavelength precision test assesses how reproducibly a scanning UV-Vis spectrophotometer can measure at each specific wavelength in the wavelength range. Wavelength precision is tested by calculating the standard deviation of at least six replicate measurements of the absorbance peaks (Figure 3). USP<857> requires that the precision of UV-Vis instruments is better than 0.5 nm across the operational range of the instrument. To conduct a wavelength accuracy test according to USP<857>, the Cary 60 UV-Vis spectrophotometer performs a scan, and the peaks that can be resolved on the resulting spectrum (Figures 1 and 2) are then identified, and the precise location of each is cross-checked with the certified data for that standard. USP Chapter <857> requires that wavelength accuracy in the UV and visible regions of the spectrum must be ±1 nm and ±2 nm, respectively. Absorbance 1.0 0.8 0.6 0.4 0.2 0 Figure 3. 300 400 500 600 Wavelength (nm) Six overlaid wavelength scans of holmium perchlorate using an Agilent Cary 60 UV-Vis spectrophotometer and Agilent Cary WinUV software. 3

The WinUV advantage The Validate application of the Cary WinUV software makes ensuring that your instrument meets the Control of Wavelengths (Wavelength Accuracy and Precision) tests efficient and easy by automatically running the testing protocols for holmium and didymium. In addition, the wavelength accuracy can be confirmed using lines that are intrinsic to the unique Agilent Xenon flash lamp source. The Cary 60 UV-Vis meets the wavelength accuracy and precision performance requirements specified by USP<857>. The Cary WinUV software generates a report that allows the user to review the tests performed and the values obtained for each replicate measurement. Control of Absorbances Photometric accuracy Photometric accuracy and precision tests are used to establish the linearity of a UV-Vis spectrophotometer across the operational absorbance range of the instrument. In essence, these tests are used to ensure that a UV-Vis spectrophotometer yields reliable quantitative measurements. All tests for these parameters rely on the Beer-Lambert Law, which dictates that a linear relationship exists between absorbance and sample concentration. Tests for USP<857> are conducted on solutions of potassium dichromate, which has absorbance peaks in the UV region of the spectrum; NIST traceable filters (930E) can be similarly used for the visible region of the spectrum. To test photometric accuracy in the UV region of the spectrum according to USP<857>, a solution of potassium dichromate in dilute perchloric acid is measured, and the absorbance intensity at 235 nm, 257 nm, 313 nm, and 350 nm is determined. The photometric accuracy is determined automatically by the Validate application of the Cary WinUV software, with the capability to analyze up to three absorbance levels in the range of 0 200 mg/l potassium dichromate. When below 1 Abs, the absorbance accuracy must be ±0.01 Abs, and when above 1 Abs, ±1 % of the absorbance measured. Following USP<857>, photometric accuracy in the visible range of the spectrum uses NIST traceable filters that absorb between 440 635 nm. The Cary WinUV Validate application allows for up to three NIST-traceable filters to be measured automatically, with the user able to enter the expected absorbance, accuracy, and precision. The application generates a report showing the mean result (accuracy) and a Pass or Fail response as determined by the entered tolerances (Figure 4). Figure 4. Photometric precision USP <857> requires that photometric precision be determined for the UV-Vis spectrophotometer in the intended operational range. Absorbance precision is determined as the standard deviation of six replicate measurements with the tolerances described in Table 1. Figure 4 shows a typical report provided by the Cary WinUV Validate application using a Cary 60 UV-Vis spectrophotometer. The WinUV advantage The Cary WinUV Validate application allows up to three test solutions of potassium dichromate, or three absorbance levels for NIST filters, to be measured automatically. The user can easily enter the expected absorbance, accuracy, and precision allowing the intended operational range of the Cary 60 UV-Vis to be qualified. All measurements are displayed in the report with Pass/Fail recorded for each test. Stray Light Six replicates of 60 mg/l potassium dichromate were measured, and the Agilent Cary WinUV Validate application generated a report for photometric accuracy and precision (standard deviation). The test for stray light quantifies light that is detected by the UV-Vis spectrophotometer, but is actually from a wavelength other than that selected reaching the detector. Because the detector in the instrument cannot differentiate between the types of light that it measures, all light is measured. This means that any stray light that is detected can yield inaccuracy and problems with quantitative analyses because it can decrease photometric selectivity and create a nonlinear photometric response (degrade the Beer-Lambert Law relationship). The stray light tests use solutions that have no transmission within a specified wavelength range, so that any light reaching the detector indicates the presence of stray light. 4

Procedure and performance limits The USP<857> prescribes a new method for measuring stray light that uses differing pathlength cells, and comparing the measurement from the sample and reference positions in the instrument. For the Cary 60, the alternative method described in USP<857> is used in which each analytical solution is measured at a single wavelength, and the % transmission (%T) is reported. This method is valid, and can be used to demonstrate that any Cary 60 UV-Vis spectrophotometer is USP<857> compliant for stray light. Cary WinUV advantage The stray light tests are performed automatically by the Validate application of Cary WinUV, and the Cary 60 UV-Vis spectrophotometer passes the stray light test if the %T is less than the prescribed tolerance (Figure 5). Validate Report: What Happens When You Pass All Tests? Agilent recommends that the full suite of tests be regularly undertaken to verify performance, and help build a database of instrument operating parameters that will aid troubleshooting and streamline maintenance procedures. This is easy to do with the Validate application of Cary WinUV software, which provides a fully automated method for verifying that your instrument is performing to the specifications prescribed in Chapter <857>. The user must simply enter the values and tolerances from their CRMs, and place each sample into the instrument when prompted. All collected results are displayed in the Validate report with Pass/Fail recorded for each test, with the Cary 60 UV-Vis spectrophotometer meeting the performance requirements specified by the USP<857>. Selecting an instrument Figure 5. The Agilent Cary WinUV Validate application reports the %T measured for each stray light analtyical sample, and reports a Pass or Fail against the tolerance for the Agilent Cary 60 UV-Vis. Resolution The resolution of a UV-Vis spectrophotometer is the narrowest spectral bandwidth that the instrument can achieve, and is important when measuring samples that have complex spectra or spectra that have multiple, near overlapping absorbance peaks. Procedure and performance limits The resolution test involves measuring the spectrum of a 0.020 % v/v solution of certified samples of toluene in hexane (UV grade) between 275 to 265 nm, and calculating the ratio of the absorbance maxima and minima that are found at approximately 269 and 266 nm, respectively. The calculated absorbance ratio is dependent upon the spectral bandwidth of the instrument used. The reputation of all quality-driven pharmaceutical laboratories is dependent upon maintaining the quality of the results they produce. This can only be obtained with the utmost confidence in the instrumentation used. Agilent Technologies is a trusted manufacturer with a strong presence in the pharmaceutical industry. The Agilent Cary 60 UV-Vis spectrophotometer is an integral instrument in the Agilent suite of analytical tools, and is manufactured according to a quality management system certified to ISO 9001. It meets or exceeds all the performance requirements prescribed by global pharmacopeia. The Cary 60 UV-Vis spectrophotometer is built around the unique Agilent Xenon flash lamp source that has been proven to collect high quality data over the complete UV Vis wavelength range. The patented Xenon flash lamp has the lowest cost of ownership, as lamps routinely last more than 10 years, thus minimizing lamp replacement and expensive instrument revalidation costs. It also provides usability benefits for room light immunity, efficiency savings (the Cary 60 has no warm up time), and performance benefits (great linear absorbance range and fast scanning for improved productivity). The Cary 60 UV-Vis spectrophotometer also offers a comprehensive software package to help achieve compliance with 21 CFR part 11 and EU Annex 11 [1]. This software product helps achieve data integrity and traceability for all electronic records associated with the operation of the Cary 60 UV-Vis spectrophotometer, including the Validate application used to perform the instrument performance tests described in this white paper. 5

Reference 1. Support for Title 21 CFR Part 11 and Annex 11 Compliance: Agilent Cary WinUV Pharma, Agilent Technologies White Paper, publication number 5991-7268EN (2016). For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc., 2016 Printed in the USA December 1, 2016 5991-7269EN