ctbuh.org/papers Prediction and Compensation of Column Shortening for Bitexco Financial Tower Title:

Similar documents
HanSoo Kim, Department of Architectural Engineering, Konkuk University

Predicting Axial Shortening of Vertical Elements in High Rise Buildings by Using PCA Method

ctbuh.org/papers Optimal Combination between Concrete Strength and Sets of Forms in High-rise Building Title:

Construction of complex RC tall building considering time-dependent properties of concrete and construction sequence

Risk Distribution Profile for Differential Column Shortenging Using a Possibility Theory Approach

Axial shortening in an 80-storey concrete building

midas Gen Advanced Webinar on Construction Stage Analysis with Special Emphasis on Column Shortening

MahaNakhon Tower History of a Design & Build. Dr. Kanokpat Chanvaivit, Senior Design Manger, Bouygues-Thai Ltd.

In-plane testing of precast concrete wall panels with grouted sleeve

midas Gen Advanced Webinar Column Shortening for High-rise Building

ctbuh.org/papers Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Title:

Structural System of North-East Asia Trade Tower in Korea

Seismic Performance of Residential Buildings with Staggered Walls

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

Deflection Analysis with Shoring Load Transfer Coefficient for Post-Tensioned Slab

When old meets new: Monitoring load sharing in a concrete building extended upwards

EVALUATION OF TIME-DEPENDENT BEHAVIOUR OF COMPOSITE CONCRETE SLABS WITH STEEL DECKING (AN EXPERIMENTAL STUDY)

ES

APPLICATION OF ULTRA-HIGH PERFORMANCE CONCRETE TO PEDESTRIAN CABLE-STAYED BRIDGES

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

ctbuh.org/papers Reform Measures of Korea s High-rise Buildings Construction Period Title: Ki-In Kim, Senior Manager, HanmiParsons Co., Ltd.

Effect of Column Shortening on the Behavior of Tubular Structures

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

The Effect of Column Axial Load on the Progressive Collapse

Shaking Table Model Test of a HWS Tall Building

ctbuh.org/papers A Study of Flat Plate Slab Column Connections with Shear Plate in Tall Concrete Building using Experimental and Numerical Analysis

Office Building-G. Thesis Proposal. Carl Hubben. Structural Option. Advisor: Dr. Ali Memari

CTBUH Technical Paper

Pushover Analysis of Reinforced Concrete Structures with Coupled Shear Wall and Moment Frame. *Yungon Kim 1)

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Shoring and Reshoring Fundamentals

Seismic Behavior of Composite Shear Wall Systems and Application of Smart Structures Technology

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

1. Cast-in-place concrete is specified in Section

SEISMIC PERFORMANCE OF BRIDGE SLAB-COLUMN JOINTS WITH HEADED REINFORCEMENT

Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

Franklin Square Hospital Center Patient Tower

Creep testing and analysis of high strength concrete panels under eccentric loading - buckling effects

CHAPTER 5 FRESH AND HARDENED PROPERTIES OF CONCRETE WITH MANUFACTURED SAND

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

A-One Polar Ltd. Bhulta,Rupgonj,Narayangonj. ( , ) 27th April 2014

Original Publication: International Journal of High-Rise Buildings Volume 6 Number 3

Level 6 Graduate Diploma in Engineering Structural analysis

U.S. General Services Administration Progressive Collapse Design Guidelines Applied to Concrete Moment-Resisting Frame Buildings

Thesis Proposal. Matthew R Peyton

IJSRD - International Journal for Scientific Research & Development Vol. 5, Issue 06, 2017 ISSN (online):

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

State of Practice of Performance-Based Seismic Design in Korea

ctbuh.org/papers Interconnectivity of Design and Construction for Complex Towers in Relation to Movement Issues Title:

Technical Report #1. Matthew R Peyton

Thermal Loads Effect on Response of One- Story Reinforced Concrete Frame Buildings in UAE

Progressive Collapse Assessment of RC Structures under Instantaneous and Gradual Removal of Columns

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Thesis Proposal. La Jolla Commons Phase II Office Tower San Diego, California. December 13, 2013

SUSTAINABLE CONCRETE COLUMNS WITH INNOVATIVE MULTI-SPIRAL SHEAR REINFORCEMENT ABSTRACT

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

BEHAVIOR OF REINFORCED CONCRETE ONE-WAY SLABS STRENGTHENED BY CFRP SHEETS IN FLEXURAL ZONE

Design of High Strength Concrete Filled Tubular Columns For Tall Buildings

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

Challenges and Opportunities for the Structural Design of the Jamsil Lotte World Tower

Application of Buckling Restrained Braces in a 50-Storey Building

Performance of Multi-story RCC structure with Floating Column

Technical Specification for Concrete Structures of Tall Building

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

Applications of sustainable post-tensioned concrete slabs

Effect of Loading and Beam Sizes on the Structural Behaviors of Reinforced Concrete Beams Under and After Fire

Original Publication: International Journal of High-Rise Buildings Volume 1 Number 3

Seismic Design of Cast-in-Place Concrete Diaphragms, Chords and Collectors

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

Questions with Solution

Compression Test for Precast Encased Composite Columns with Corrugated Steel Tube

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Structural Performance Assessment and Control of Super Tall Buildings During Construction

NON-LINEAR STRUCTURAL INTEGRITY ANALYSIS

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering, Indian Institute of Technology Madras

Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete

OVERALL STRUCTURAL SYSTEM

SECTION US Patent 8,857,130 B1 CAST-IN-PLACE CONCRETE WITH ARDEX CONCRETE MANAGEMENT SYSTEMS (ACMS ) EARLY MC APPLICATION

Investigation of fibre reinforcing the cover of concrete columns

Study of Fracture Properties of Cement Stabilized Macadam

Keywords: Discrete Staggered Shear Wall, High-Rise Building, Response Spectrum Analysis, Storey Drift.

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

INSTITUTE OF CONCRETE TECHNOLOGY CONCRETE TECHNOLOGY & CONSTRUCTION Stage 2: GENERAL PRINCIPLES Learning objectives

Total 30. Chapter 7 HARDENED CONCRETE

STUDY AND COMPARISON OF CONTRUCTION SEQUENCE ANALYSIS WITH REGULAR ANALYSIS BY USING ETABS

Compound and Engineering Application of Fiber Reinforced Concrete with Low Shrinkage

Case Study: Challenges of a Single-layer Reticulated Dome

3.4.2 DESIGN CONSIDERATIONS

MODELLING OF SHEAR WALLS FOR NON-LINEAR AND PUSH OVER ANALYSIS OF TALL BUILDINGS

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

[TECHNICAL REPORT 3] Lateral System Analysis

DIAGRID STRUCTURAL SYSTEM: STRATEGIES TO REDUCE LATERAL FORCES ON HIGH-RISE BUILDINGS

2. Outline of the bridge 3-span continuous deck extradosed bridge Bridge length

BOAST. West Coast. Set to open this spring, the tallest building on the West Coast resists wind and seismic drifts with massive braces.

MEASUREMENT OF FRICTION COEFFICIENT OF POST-TENSIONING SYSTEM USING SMART STRAND

SENIOR THESIS PROPOSAL STRUCTURAL REDESIGN USING STEEL FRAMING

Ultimate strength of high-strength composite columns after sustained service loading

Transcription:

ctbuh.org/papers Title: Authors: Subject: Keywords: Prediction and Compensation of Column Shortening for Bitexco Financial Tower Seongdeok Kang, Assistant Chief Engineer, Hyundai Architects & Engineers Associates Jaesung Choi, Chief Engineer, Hyundai Architects & Engineers Associates Hakseong Kim, Chief Engineer, Hyundai Architects & Engineers Associates Inki Kim, CEO, Hyundai Architects & Engineers Associates Structural Engineering Concrete Core Structure Publication Date: 2011 Original Publication: Paper Type: CTBUH 2011 Seoul Conference 1. Book chapter/part chapter 2. Journal paper 3. Conference proceeding 4. Unpublished conference paper 5. Magazine article 6. Unpublished Council on Tall Buildings and Urban Habitat / Seongdeok Kang; Jaesung Choi; Hakseong Kim; Inki Kim

_ MS04-13 Prediction and Compensation of Column Shortening for Bitexco Financial Tower Seongdeok Kang 1, Jaesung Choi 2, Hakseong Kim 3, Inki Kim 4 Assistant Chief Engineer 1, Structural Design Dept., Hyundai Architects & Engineers Associates, 140-2 Gye-dong, Jongno-gu, Seoul, Korea, sdkang@hda.co.kr Chief Engineer 2, Structural Design Dept., Hyundai Architects & Engineers Associates, jschoi01@hda.co.kr Chief Engineer 3, Engineering Division, Hyundai Architects & Engineers Associates, star@hda.co.kr CEO 4, Hyundai Architects & Engineers Associates, ikk2537@hda.co.kr Biography Inki Kim, CEO of Hyundai Architects & Engineers Associates Co., Ltd. Mr. Kim is a CEO of Hyundai Architects & Engineers Associates. Since 1977, he has been with the Hyundai Engineering & Construction and the Hyundai Architects & Engineers Associate. Mr. Kim has also leaded for various professional and academic projects in the areas of architectural design and structural engineering. He is experienced in both high-rise steel and concrete buildings. He is also leaded for research team in the area of high-rise building. Mr. Kim has over 34 years of structural engineering experience and is registered as a qualified architect and professional engineer in Korea. Recent high-rise building projects include the Bitexco Financial Tower in Vietnam, the International Finance Centre, and the Haeundae AID in Busan. 811

_ Abstract The effects of column shortening, both elastic and inelastic, take on added significance need special consideration in design and construction. Axial shortening of columns due to long term creep and shrinkage is inevitable in tall reinforced concrete buildings. Therefore, a reasonable idea about the probable axial shortening could be important for construction engineers and project managers as well. A procedure is developed to predict the long-term deformations of reinforced columns and walls. The presentation will describe how to properly complete a Vietnam Bitexco Financial Tower Project. This is a commercial office development located in Hochiminh, Vietnam. The development is 258m(68 stories) in height and has three levels of basement. The tower is structurally composed of central reinforced concrete core and perimeter reinforced concrete columns connected in flat plate slab. The plan of the tower continually changes from oval to triangle at higher levels, so that some perimeter columns are declined in elevation and their locations also change in respective plans. Field measurement is performed to verify predicted axial shortening amounts and update compensation. Vibrating wire strain gauges are installed in selected vertical members before pouring concrete. Actual compressive strains of columns and walls due to load application and environmental effects are measured by vibrating wire strain gauges embedded in the member. Target members are selected when the results of initial axial shortening are available. Keywords Column shortening, Long term creep, Shrinkage, Field measurement, Long term deformation 1. Introduction In high rise building serviceability aspects should take into account vertical shortening effects in the design stage. In this paper axial displacements are described as consequence of sequential loading phases and long term effects. Computer aided analysis has been carried out to deeply study the phenomena and main results have been reported in this document. In very high rise buildings, the cumulative vertical movements due to creep and shrinkage may cause distress in the structure and induce forces into horizontal elements especially in the upper regions of the building. As a consequence also the stress distribution in vertical structures can be different from design values. Since the differential shortening between core structure and peripheral columns causes unwanted slope to floor horizontal structures, compensations are needed to assure a proper final position for each slab within the building. Essentially, during the construction process, each of the story support undergoes elastic shortening due to construction sequential loading (that are the loads imposed by the upper levels as they are completed); in addition, columns begin to shrink from moisture loss and creep as a result of the time depending effects. Vietnam Bitexco Financial Tower Project is a commercial office development located in Hochiminh, Vietnam (Fig. 1-1). The development is 258m (68 stories) in height and has three levels of basement. HYUNDAI Architects&Engineers Assoc. has been appointed to perform the Column Shortening Prediction to provide relevant information for differential shortening between vertical members as well as each level of the tower. The scope of works to be undertaken by HYUNDAI A&E is as follows: Predict tentative values of axial shortening of core walls and perimeter columns based on structural drawings and analysis data, construction program, and environmental conditions; Provide the necessary preset values of core walls and perimeter columns based on tentative values of axial shortening; Perform creep and shrinkage tests on the concrete specimens to update the timedependent material properties and enhance the accuracy of tentative values of axial shortening and corresponding presets; Perform on-site measurement for the axial shortening of selected core walls and columns to update the values of axial shortening and corresponding presets. 812

_ Fig. 1-1. Vietnam Bitexco Financial Tower 2. Analyses for Column Shortening Structural drawings are the basis of the structural layouts, dimensional data of core walls and columns, rebar content, and the grades of concrete, steel, and rebar. Elastic Modulus of concrete is calculated from its strength according to ACI 318. Both the specific creep and ultimate shrinkage values are taken from ACI 209 and PCA report (Fintel, Mark, Ghosh, S. K, and Iyengar, Hal, Column Shortening in Tall Structures Prediction and Compensation (EB108.01D), Portland Cement Association, 1986). Members to be considered for the shortening prediction are selected by the following criteria: All perimeter columns are considered; Core walls are put together into 5 groups (W1~W5, see Fig. 2-1 below); 813

_ C1 C16 C2 C15 W1 C3 C14 W2 C4 C13 W3 W4 C5 C12 C11 W5 C7 C6 C10 C8 C9 Fig. 2-1. Structural layouts Fig. 2-2. Structural analysis model showing reactions at columns for Dead Load at 27 th floor All the design loadings are extracted by manipulating the ETABS model file. In addition to the existing 4 categories of loadings in the model, i.e. Dead Load (DL), Superimposed Dead Load (SDL), Façade, and Live Load (LL), DL is further classified according to the construction program as followings: Concrete column calculated with member dimensions and concrete density Topping concrete on slab slab weight Load reduction factor for Live Load is assumed as 0.5, which is a sufficient value as compared with the minimum 0.4 for high-rise office buildings. Since the column layout is different for every floor and core layout also changes several times, the distribution of floor load is recalculated for all stories from B3F to 68F by analyzing an isolated story model from the original ETABS model. Creep and shrinkage components of axial shortening are influenced by the environmental condition such as relative humidity. The average value (71%) is used in the shortening prediction. The sequential application of each floor load is input based on the internal construction schedule. With regard to the shortening prediction the following criteria is adopted: Each floor load (DL) is applied on Finish date of the construction schedule; Façade Load is applied on Finish date of Curtain Wall Unit work schedule; LL is applied, which is 668 days after the concrete for B3F core walls and B2F core slabs are cast. Total shortenings of core walls at top level are predicted from 80mm to 130mm. Total shortenings of columns are produced from 85mm to 160mm. These predicted values are well accordant with the values calculated by LERA (refer to structural drawings No.S-020). The SUBTO shortening after the installation of slabs are used to evaluate the differential shortening between adjacent members. Differential shortenings between core walls and columns and between adjacent columns are predicted within allowable tolerances (20mm, refer to Specification Sec. 03 30 00-1.6B) except C8, C9 columns. Relatively large SUBTO shortening at C8, C9 columns are occurred by helipad loads. Maximum differential shortening (74mm) are developed between 814

_ C8 column and W5 at 47 th floor. Core walls and perimeter columns except C8, C9 columns are well within the allowable tolerance. Therefore, presets are only required for C8, C9 columns to have horizontal floors within allowable tolerance. 121mm C1 122mm 109mm C16 C2 145mm 105mm C14 C15 114mm W2 133mm W1 126mm C3 111mm 96mm C4 123mm C13 82mm W3 111mm 91mm C12 W4 83mm W5 C5 C6 104mm 10 W5 7 82mm C11 C7 84mm 43mm 9 8 82mm C10 C9 C8 133mm 164mm (27)47F(70) Fig. 2-3. Distribution of absolute shortenings Fig. 2-4. Differential shortenings at the perimeter at top levels of each member of C8, C9 columns 3. Material Test Specimens poured in the vertical members were made at the construction site. These were delivered at the laboratory in Korea with the moisture curing cover. The specimens were moist-cured for 28 days, followed by Elastic Modulus and cylinder strength test. Three creep specimens were under 30% of ultimate cylinder strength for more than three months in the constant temperature and humidity room (20±2, 60%). Shrinkage test specimens were kept in the same environment as the creep test specimens without any loading. Data readings from the strain gauges were recorded with constant interval (one time a day) during three months. Nonlinear regression analysis of the test data is performed using MathCAD to find the values for Specific Creep and Ultimate Shrinkage. Concrete strain gauges were attached on the side surface of the cylinders in the middle and the obtained data were averaged in doing nonlinear regression analysis. Manual hydraulic jack with appropriate capacity was used to apply constant load under the spring-type creep test machine. The applied load in the creep test was monitored and the relaxation in the load should be recovered to the recorded value at the time of data readings. Table 3-1. Test Results Initial analysis Test results Concrete strengths 68MPa 30MPa 40MPa 67MPa 56MPa 40MPa 54MPa Specific creep 0.40E-06 0.91E-06 0.69E-06 0.34E-06 0.45E-06 0.75E-06 0.84E-06 815

_ Ultimate shrinkage 750E-06 750E-06 750E-06 290E-06 456E-06 713E-06 1000E-06 Fig. 3-1. Time-dependent shrinkage of 50MPa-mixture 1 Fig.3-2. Time-dependent creep of 50MPa-mixture 1 Fig. 3-3. Time-dependent shrinkage of 40MPa Fig.3-4. Time-dependent creep of 40MPa Fig. 3-5. Time-dependent shrinkage of 30MPa 4. Field Measurement Fig.3-6. Time-dependent creep of 40MPa Field measurement is performed to verify predicted axial shortening amounts and update compensation. Vibrating wire strain gauges are installed in selected vertical members before pouring concrete. Actual compressive strains of columns and walls due to load application and environmental effects are measured by vibrating wire strain gauges embedded in the member. Target members are selected when the results of initial Axial Shortening are available. The preferred levels to be measured are 4 th Floor (the lowest level possible where the shortening from all the following load applications can be recorded), 35th Floor (different core concrete strength), and 49 th Floor (the 816

_ last oval level, above which the shape of plan becomes triangular). 2 strain gauges moved from 49 th floor were installed on 4 th floor slab below C10, C16 columns. The influence of 35MPa slab between 50MPa columns will be found from measurement results. 5. Conclusions Fig.4-1. Installation plan of strain gauge (4F) To predict axial shortenings of core walls and columns in Vietnam Bitexco Financial Tower, analysis, material test, and field measurement were performed. The results of works are summarized as followings. In analysis, differential shortenings between core walls and columns and between adjacent columns were predicted within allowable tolerances (20mm, refer to Specification Sec. 03 30 00-1.6B) except C8, C9, and C13, C14 columns. Relatively large SUBTO shortening at C8, C9 columns were occurred by helipad loads. Therefore, presets are only suggested for C8, C9, and C13, C14 columns. In material tests, 50MPa (two mixtures), 40MPa, and 30MPa concrete were tested to find 28days strength and the values for Specific Creep and Ultimate Shrinkage. Test results were used in 1 st and 2 nd re-analysis. 817

_ In field measurements, the shortening curves of predicted and measured values show the similar trend except C1, C13, and C16 at 4 th floor. As considering neighboring members and measurement results of slabs, measured value of C1, C13, and C16 seem abnormal. Maybe there were locally mechanical problems in gauges. Based on the measurement results of same members in 35 th and 49 th floors, creditability of these values were low. The shortening values of C8 and C9 columns by helipad loads (deck slab and screed) were properly considered in predicted values. Based on the comparison results, it can be said that measured values are relatively consistent with predicted values. Therefore behavior of shortenings for this tower could properly predicted by analysis results. As a final word for the shortenings, differential shortenings between core walls and columns and between adjacent columns will be within allowable tolerances on target day (1,000days after installation of the lowest basement floor) based on the results of analysis, compensations, and field measurement results. References Building Code Requirements for Reinforced Concrete, ACI 318-83 American Concrete Institute, Detroit, Mich., 1983. M. Fintel, S.K. Ghosh, H. Iyengar, Column Shortening in Tall Structures Prediction and Compensation, Portland Cement Association, pp.198. ACI 209.2R-08, Guide for Modeling and Calculating Shrinkage and Creep in Hardened Concrete, 2008. ACI Committee 318, Building Code Requirement for Structural Concrete (ACI 318-08), American Concrete Institute, Farmington Hills, MI, 2008. Faber O. Plastic yield, shrinkage and other problems of concrete and their effects on design, Minutes of the Proc. of the Inst. of civil engineers, 225(1927), pp.27 73. Bazant ZP, Prediction of concrete creep effects using age-adjusted effective modulus method, ACI Journal, 69(1972), pp.212 7. D.Bast W, Terry RM, Parker L, Shanks S. Measured shortening and its effects in a Chicago high-rise building, Proceedings of the Third Forensic Engineering Congress, San Diego, CA, 2003. Bazant ZP, Baweja S. Creep and shrinkage prediction model for analysis and design of concrete structuremodel B3, Report No. 94-10/603c, Chicago, Northwestern University, 1995. Jayasinghe MTR, Jayasena WMVPK. Effect of axial shortening of columns on design and construction of tall reinforced concrete buildings, Practice periodical on structural design and construction, 9(2004), pp.70 8. ACI Committee 209. Prediction of creep, shrinkage, and temperature effect in concrete structures, Detroit, MI, 1992. 818