SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Similar documents
A NEW CFRP STRENGTHENING TECHNIQUE TO ENHANCE PUNCHING SHEAR STRENGTH OF RC SLAB-COLUMN CONNECTIONS

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

Seismic Behavior of Concrete Columns Confined with Steel and Fiber-Reinforced Polymers

Seismic Behavior of Low Strength RC Columns with Corroded Plain Reinforcing Bars

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns 1

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

EXPERIMENTAL STUDY ON RC COLUMNS RETROFITTED BY FRP AND SUBJECTED TO SEISMIC LOADING

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

SHAKING TABLE TEST OF LARGE SCALE NONDUCTILE RC FRAMES RETROFITTED WITH FRP COMPOSITES

In-plane testing of precast concrete wall panels with grouted sleeve

GFRP retrofitted RC frames with columns subjected to high axial stresses

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

AFRP retrofitting of RC structures in Japan

REPAIR OF EARTHQUAKE DAMAGED SQUAT REINFORCED CONCRETE SHEAR WALLS USING EXTERNALLY BONDED CFRP SHEETS

SEISMIC RETROFIT OF NON-DUCTILE RECTANGULAR REINFORCED CONCRETE COLUMNS BY CFRP JACKETING

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

Experimental tests on RC hollow columns strengthened with FRPs

Retrofitting and Strengthening of Damaged Reinforced Concrete Columns Using Steel Angels Wrapped with Steel Wire Mesh

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

BEHAVIOR OF FULL-SCALE SHEAR DEFICIENT CORNER RC BEAM-COLUMN CONNECTIONS RETROFITTED WITH CFRP SHEETS

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

SEISMIC UPGRADING OF EXISTING RC ORDINARY MOMENT RESISTING FRAMES USING FRPS

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

SEISMIC STRENGTHENING OF INFILLED RC FRAMES BY CFRP

USE OF CFRP ANCHORS TO STRENGTHEN LAP SPLICES OF RECTANGULAR RC COLUMNS

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Repair of Earthquake-Damaged RC Columns with FRP Wraps

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

Influence of Longitudinal FRP Straps on the Behaviour of Circularised and FRP Wrapped Square Hollow RC Concrete Specimens

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Strengthening of infilled RC frames by CFRP

BEHAVIOUR OF FRP REINFORCED CONCRETE UNDER SIMULATED SEISMIC LOADING

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

1. INTRODUCTION. Fig.1 Dimension of test specimen

SEISMIC RETROFIT OF BEAMS IN BUILDINGS FOR FLEXURE USING CONCRETE JACKETING

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

An Experimental Investigation on Flange Bonded Retrofitting of RC Beam-Column Joints using CFRP

An Experimental Study on the Effect of Opening on Confined Masonry Wall under Cyclic Lateral Loading

EXPERIMENTAL RESULTS

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

EXPERIMENTAL STUDY ON REINFORCED CONCRETE COLUMN STRENGTHENED WITH FERROCEMENT JACKET

Seismic Behavior of Shear-Critical Reinforced Concrete Frame: Experimental Investigation

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

Retrofitting methods

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Seismic Resistance of Square Concrete Columns Retrofitted with Glass Fiber-Reinforced Polymer

BEHAVIOR OF RC BRIDGE COLUMNS UNDER CYCLIC FLEXURAL-TORSIONAL LOADINGS WITH MODERATE SHEAR

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

Failure Mechanism of Reinforced Concrete Structural Walls with and without confinement

Hybrid Simulation Based on Finite Element Analysis of a Continuous Gird Bridge with Fiber Reinforced Polymer composition

EXPERIMENTAL STUDY ON THE SEISMIC PERFORMANCE OF EXTERNALLY CONFINED REINFORCED CONCRETE COLUMNS

Seismic Upgrade with Carbon Fiber-Reinforced Polymer of Columns Containing Lap-Spliced Reinforcing Bars

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Design of FRP confinement for square concrete columns

MPC-526 December 20, 2016

Behavior of Reinforced Concrete Walls with Mesh Reinforcement Subjected to Cyclic Loading

Structural Upgrade of Reinforced Concrete Column-Tie Beam Assembly using FRP Composites

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Finite Element Simulation of Low Concrete Strength Beam-Column Joint Strengthened with CFRP

Seismic analysis of a RC frame building with FRP-retrofitted infill walls

Experimental Investigation of RC Beam Column Joint Strengthening

Restoration of Pre-damaged RC Bridge Columns with Deficient Plastic Hinge Regions Using Basalt FRP

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

SEISMIC PERFORMANCE AND RETROFIT OF BRIDGE FOOTINGS. David I. McLean 1

SEISMIC BEHAVIOR OF RC COLUMNS WITH VARIOUS TIE CONFIGURATIONS

SEISMIC RESPONSE OF END-CONFINED REINFORCED CONCRETE BLOCK SHEAR WALLS

Experimental study on behavior of Retrofitted with FRP wrapped RC Beam- Column Exterior Joints Subjected to cyclic loading

EXPERIMENTAL INVESTIGATION OF DAMAGED EXTERIOR RC BEAM COLUMN JOINTS RETROFITTRD BY FRP JACKETING

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

SEISMIC RETROFIT OF RECTANGULAR BRIDGE COLUMNS USING CFRP WRAPPING MESAY ABEBAW ENDESHAW

Joint. investigation and. partially confined. techniques. jacketing. in the overall frame 2008) enlargement proposed method not.

AN IMPROVED COMPOSITE ANCHORING SYSTEM

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

SEISMIC BEHAVIOR OF FOUR-CIDH PILE SUPPORTED FOUNDATIONS

Experimental Study on the Behaviour of Plastered Confined Masonry Wall under Lateral Cyclic Load

Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loading P.Rajaram 1 A.Murugesan 2 and G.S.

Anchoring FRP laminates for the seismic strengthening of RC columns

Comparisons to Tests on Reinforced Concrete Members

Pile to Slab Bridge Connections

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

TESTS ON A POST TENSIONED MOMENT RESISTING CONNECTION FOR PRECAST CONCRETE STRUCTURES

RESILIENT INFRASTRUCTURE June 1 4, 2016

Innovative Techniques for Seismic Retrofit of Reinforced Concrete Joints

Strengthening of RCC Column Using Glass Fibre Reinforced Polymer (GFRP)

Cyclic In-Plane Shear of Concrete Masonry Walls Strengthened by FRP Laminates

Confining concrete cover of GFRP tube reinforced concrete columns with polymer grids

RETROFIT OF EXISTING REINFORCED CONCRETE BRIDGES WITH FIBER REINFORCED POLYMER COMPOSITES. Bahram M. Shahrooz Serpil Boy. Report No.

Transcription:

Asia-Pacific Conference on FRP in Structures (APFIS 7) S.T. Smith (ed) 7 International Institute for FRP in Construction SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP) O. Ozcan, B. Binici * and G. Ozcebe Department of Civil Engineering, Akdeniz University, Antalya, Turkey, 8 (Currently on leave at the Middle East Technical University for graduate study) Department of Civil Engineering, Middle East Technical University, Ankara, Turkey, 65. Email: binici@metu.edu.tr ABSTRACT Reinforced concrete columns with non-seismic detailing are often vulnerable to the effects of a major earthquake. In this study, the structural behaviour of undamaged and moderately damaged columns, which were retrofitted with carbon fiber reinforced polymers (CFRP) is investigated. The experimental program consists of four specimens having inadequate tie spacing, 9 degree hooks and plain reinforcing bars that were tested under lateral cyclic displacement excursions under a constant axial load of approximately 7% of the axial load carrying capacity. One reference specimen without any strengthening and one strengthened specimen with strengthening but without any pre-damage were tested. In addition, two similar specimens tested to moderate damage level of % drift ratio were repaired and retested. In one of the pre-damaged columns the repairing process was performed in the presence of constant axial load. The main parameters investigated in this study were the presence of axial load on the column during repairing, effect of pre-damage on ultimate displacements and the effect of CFRP wrapping on strengthened and repaired columns. The ultimate drift ratio for retrofitted columns increased to 6% which was only.5% for the reference column. Severe stiffness degradation was observed in both of the repaired columns due to the moderate level of pre-damage. For the repaired columns, the presence of the axial load during repairing did not significantly affect the ultimate drift ratio significantly however the enhancement in strength was not observed as compared to its companion specimen. KEYWORDS RC columns, axial load effect, CFRP, pre-damage, repair, strengthening. INTRODUCTION Poor performance of reinforced concrete columns during recent earthquakes in Turkey (Kocaeli 999, Düzce 999, Bingöl ) demonstrated the major deficiencies in building columns owing to low concrete strength, inadequate transverse reinforcement and poor structural detailing. Hence, convenient strengthening and repair strategies should be utilized in the light of new and suitable retrofitting materials. The traditional method of repairing or strengthening reinforced concrete columns by means of concrete or steel jacketing involves difficult implementation procedures especially in building columns. Consequently, new retrofitting methods for columns using CFRP should be investigated for repairing and strengthening processes that were found to be effective as concrete and steel jacketing in improving seismic response as stated by Seible et. al. (997), Sheikh and Yau (), Iacobucci et. al. (), and Haroun et. al. (). By impeding premature bar buckling and providing confinement, CFRP retrofitted columns showed improved seismic resistance. The use of plain bars as main reinforcement was a common practice encountered in Turkey for columns built in structures in 96 s and 97 s which constitutes almost 6% of the current vulnerable building stock. Therefore there is a need to understand the behaviour of RC columns with and without any retrofit. So, the performance of FRP retrofitted columns require further examination due to seismic vulnerabilities commonly observed in Turkey include plain bars for longitudinal and transverse reinforcement, 9 degree hooks for stirrups and low concrete strength. Accordingly, a new experimental program investigating ) the effect of CFRP wrapping on strengthened and repaired columns and ) the effect of presence of axial load during repairing process was conducted in order to examine the seismic response of typical building columns. 9

EXPERIMENTAL PROGRAM Test Specimens The dimensions of the test specimens were 5 5 mm that were connected to a 5 5 4 mm stub. The details of the specimens are shown in Figure. The longitudinal reinforcement consisted of eight mm diameter plain bars and the transverse reinforcement consisted of mm diameter plain bars with a spacing of mm with 9 degree hooks simulating typical deficient construction practice in Turkey. Table presents the details of test specimens. Concrete and Steel All the specimens were cast with batches of concrete having maximum 5 mm gravel size with a target compressive strength of MPa. Concrete compressive strength values at the test day of the specimens are presented Table. The plain longitudinal bars and transverse reinforcement had 87 MPa yield strength (f y ) and 4 MPa ultimate strength (f u ) as obtained from tension test results. LVDT Dial Gage Enerpac RCH66 jacks for vertical load 7kN. load cells controlling axial load 7kN. 5 kn (C/T) Load cell Test specimen kn (C/T) hydraulic jack for lateral loading Strong Floor C: Compression T: Tension 8φ4 bolts connecting column to the test setup Units: mm Figure. Test setup and details of the test specimens. Transverse Reinforcement: φ / mm (plain bars) with 9 deg. hooks Longitudinal Reinforcement: 8 x φ (plain bars) Table. Test specimen details. Specimen Properties Longitudinal Axial Load * Column CFRP Specimen f c f y Reinforcement Steel Ratio Level,N/N Type** Ply No (MPa) (MPa) Longitudinal Transverse (%) (%) S-H--. Ref., NL D= mm at S-H-- 9.5 8 mm S - NL 87.48 7. S-HD-- 9. Plain bars R - NL Plain bars. R - UL * N =.85 f c A g + A s f y ** Ref., S and R indicate reference, strengthened and repaired columns, respectively. NL and UL indicate CFRP application was made under no load and under load, respectively. CFRP Application Carbon fiber wrapping system was used to retrofit and repair the test specimens. CFRP plies having.65 mm thickness with an elasticity modulus of MPa and ultimate strain of.5 were used in retrofitting process. At the first phase of the application, the corners of each column were rounded to a radius of mm. After rounding off the corners, a thin layer of undercoat was applied on the plastic hinge region of the column (within 65 mm from column base) using a brush for the strengthened column. For the repaired columns this process was done after the removal and cleaning of spalled cover concrete (Figure.a,.b). Then, the column was repaired using epoxy based mortar having a corner radius of mm. This process was followed by the undercoat application again. (Figure.c). Subsequently, the epoxy based mortar was applied and FRP sheet was wrapped around the test region of the column (65 mm) starting from 5 mm above the column-stub interface (Figures.d). To achieve a successful interlock between column and the CFRP sheet, homemade CFRP anchorages were placed along the test region of the columns. In order to apply these carbon fiber anchor dowels, mm diameter holes with a depth of 8 mm were drilled between two longitudinal bars at heights of 5,, 45, 6 mm. The CFRP anchor dowels were formed from mm carbon fiber strips. These strips were rolled in the fiber direction and tied with a string. After the careful folding process, mm long dowels were obtained and its 8 mm length was inserted into the holes which were drilled and cleaned previously. (Figure APFIS 7 94

.e). The anchorages were placed to prevent debonding of the overlap section of the CFRP sheet during the test. The strengthened and repaired specimens were tested precisely one week after the CFRP application (Figure.f). a. b. c. d. e. f. Figure. CFRP Application: a. Moderately damaged column (up to % drift), b. Removal of spalled cover and undercoat application, c. Repairing with epoxy based mortar, d. Applying the epoxy based mortar to the CFRP wrapping length, e. Anchorage insertion, f. CFRP wrapped column after repairing. Instrumentation and Testing All columns were instrumented by Linear Variable Displacement Transducers (LVDTs) to measure horizontal deflections and dial gages for rotations at the critical regions. There were seven LVDTs located at 5,, and mm from the column stub interface measuring deflections along the height of the column. In addition four dial gage couples were placed at a height of 5 mm that were used to record rotations relative to column - stub interface and 5 mm above it. The difference between the dial gage readings that were measured from the critical section and the surface of the column stub was accepted as the concentrated bar slip rotations due to the slip of longitudinal reinforcement in the footing. Besides, two dial gages were used in order to measure any possible movement of the column stub and strong floor. Eight strain gages were placed on longitudinal reinforcement at 5 and 5 mm heights from the surface of the column stub. The load cells were used to record the changes in lateral and axial load stages at different drift levels. There were 8 strain gages used in order to record the strain in longitudinal rebars placed 5 mm and 5 mm above the base. Columns were guided with four rollers between the guide rails to assure bending in the plane of loading. The test setup and the details of instrumentation are shown in Figure. All the column tests were conducted under constant axial load and cyclic lateral displacement excursions. The application of axial load was started just before the application of lateral loading. For the column that was repaired under axial load, the axial load level was maintained about one week during repair and curing of CFRPs to ensure proper curing of epoxy resin. Then the column was subjected to lateral loading excursions. The drift levels were incremented by.5% until the drift level of % having three cycles for each drift level. The following cycles beyond % drift level were incremented by % having two cycles for each level of drift. TEST OBSERVATIONS The lateral force column tip deflection (P Δ) were measured using four LVDTs that were located at mm from the base of the column. The P Δ responses of columns and important events during the test such as column stub cracking, CFRP debonding and CFRP rupture is presented in Figure. A similar failure mode was observed at the base of all columns due to column plastic hinging. Flexural cracks were observed in the first lateral displacement excursions and those cracks opened further and joined at both faces as the displacement excursions increased. Considering the fact that all the columns were flexural dominant having an aspect ratio of about 5.7, the observed failure mode for all columns was initiated with cracking of the column stub interface and progressed with further opening of this crack simultaneously with concrete crushing or CFRP debonding. The progression of concrete crushing and/or CFRP debonding resulted in buckling of longitudinal bars and sudden explosion of CFRP sheet. Plastic hinging started with the crushing of the corners at the base of the column and the gradual advance in the length of the hinging region reached up to a length of approximately the depth of the section, h. All the CFRP retrofitted columns experienced a sudden rupture of the CFRP sheet and consequently the observation of the plastic hinge lengths eventuated after that. However, for the reference specimen the formation of the hinging length was observed during the loading cycles. Test results are summarized in Table and the envelope curves of P Δ and M Κ responses for the columns are shown in Figure 4. The strains in longitudinal rebars above 5 mm of the base are presented in Figure 5. It can be also observed that at the end of damage cycles the longitudinal rebars are very close to yielding. APFIS 7 95

Reference Column: S-H-- In the reference specimen, S-H--, the column-stub interface cracked at.5% drift level and as the column performed inelastic displacement cycles, the slipping of the reinforcement increased as a result of the widening of the interface crack. Furthermore, evenly distributed flexural cracks were observed at both faces of the column at heights of 5 to mm. First cover crushing, initiated from the longitudinal cracks at the base of the column at a height of approximately h, was observed at % drift level. Lateral load carrying capacity degraded below 8% of the ultimate was followed by the longitudinal bar buckling at a drift level of about 4%. Retrofitted Columns: S-H--, S-HD--, All the retrofitted columns were wrapped with layer of CFRP within the expected plastic hinge region of 65 mm starting from 5mm above the column base. In all columns, the column-stub interface cracking was observed at.5% drift level. In the strengthened column, S-H--, the flexural cracks were developed at heights of 65 to mm from the base of the column at the initial cycles of displacement excursions. These cracks were closer to each other than those observed in the reference specimen. In the following cycles, the flexural cracks opened further and closed in the opposite cycles of deformations. As a result of the horizontal CFRP cracks at mm from the base, CFRP at the other face of the column started to debond at about.5% drift level. The confinement effect of CFRP helped in maintaining the lateral capacity constant and preventing longitudinal bar buckling. The interface crack (i.e. crack observed at column base stub interface) widened which resulted in increase of the longitudinal reinforcement slip at the column-stub interface and the lateral load reached the lateral load carrying capacity at about % drift. The first rupture at the CFRP sheet occurred at 5% drift and at 6% drift level the lateral load dropped 8% of the capacity by buckling of the longitudinal reinforcement. The repaired columns, S-HD-- and exhibited similar deformation behaviour. In the first phase of the tests, both of the repaired columns were subjected to a moderate damage level of % drift. Evenly distributed flexural cracks were formed at heights of 5 to mm from the column base. The only difference was the presence of axial load during the repairing process, which was about 7% of the capacity in the column S-HD-- 7. The flexural cracks that formed in the pre-damage state opened further and no new flexural cracks outside the strengthened region occurred in the retesting stage. The drift levels at which CFRP debonding, CFRP rupture and % drop in lateral capacity took place were identical for the three specimens (%, 5% and 6% drift respectively). The lateral load capacity of the repaired column did not change as compared to the capacity observed at the damage stage whereas its companion column S-HD-- gained lateral capacity enhancement of about 5%. For the repaired columns, the strength of the columns decreased compared to the strengthened column as a result of the initial damage. Furthermore, reductions in energy dissipation capacities were observed when compared to the strengthened specimen. DISCUSSIONS Effect of CFRP Wrapping Strengthening or repairing square columns with ply of CFRP sheet significantly improved the ductility and energy dissipation capacity of the columns. However, the strength and energy dissipation capacity of the repaired columns, S-HD-- and, were lower than the strengthened column, S-H--, which had no prior damage. This can be attributed to cracking and stiffness degradation that occurred in the pre-damage state, i.e. no effort was needed for the reopening of the interface crack at the base and other flexural cracks outside plastic hinge region. Wrapping layer of CFRP sheet increased the ultimate drift ratio of the retrofitted columns, S-H- -, S-HD-- and by a factor of.5 compared to the reference column S-H--. Effect of Repairing under Axial Load The effect of axial load during repairing was evaluated by comparing the columns S-HD-- and. It was observed that both of the columns performed similar inelastic responses achieving similar ultimate drift deformations. The presence of axial load during the repairing process did not affect the ultimate drift ratios (~6%). The drift levels at which the CFRP debonding and rupture took place were also similar (% and 5%, respectively) for the specimens repaired in the presence and absence of axial load. The only effect of axial load during repairing was the gain in lateral capacity of about 5% as compared to the reference column. This difference can be attributed to the high compressive strength of the epoxy repair mortar (about 7 MPa) compared to the concrete compressive strength (about MPa) of the original column. The high variation in compressive strength (.5 times the concrete) forced the repaired column S-HD-- to increase its lateral capacity after the application of the axial load. However, for the repaired column under axial load the section, APFIS 7 96

lateral load carrying capacity was kept constant (i.e. axial load was always carried by the damaged column, not by the epoxy mortar) as the section behaviour was not significantly affected by the high compressive strength of the epoxy mortar. Table. Test Results Interface CFRP % Capacity Drop Specimen Cracking Debond Rupture u, Drift (%) u, Drift (%) u, Drift (%) u, Drift (%) S-H--. (crushing) 4. S-H--.5.5 S-HD--. 5. 6.. 9 6. Column-stub interface cracking. Concrete crushing. Longitudinal bar buckling 9 6. Column-stub interface cracking. CFRP debonding. CFRP rupture 4. Longitudinal bar buckling 4 - -6-9 S-H-- Reference Specimen f c' =. MPa N / N = 7 % 8 φ (plain bars), ρ l =.48% φ / (plain bars) - - - -6 - -8-4 4 8 6 - -6 - -8-4 4 8 6 9 6. Column-stub interface cracking. CFRP debonding. CFRP rupture 4. Longitudinal bar buckling S-HD-- - Repaired Specimen f c' = 9. MPa -6 N / N = 7 % 8 φ (plain bars), ρ l =.48% -9 φ / (plain bars) - - -6 - -8-4 4 8 6 4 - -6-9 9 6. Column-stub interface cracking. CFRP debonding. CFRP rupture 4. Longitudinal bar buckling S-H-- Strengthened Specimen f c' = 9.5 MPa N / N = 7 % 8 φ (plain bars), ρ l =.48% φ / (plain bars) - Repaired Specimen f c' =. MPa N / N = 7 % -6 8 φ (plain bars), ρ l =.48% -9 φ / (plain bars) - - -6 - -8-4 4 8 6 Figure. Lateral load vs. Deflection responses of columns. (Dotted lines indicate damage cycles for repaired columns) 4 9 6 4 8 - -6 S-H-- S-H-- -9 S-HD-- - - -6 - -8-4 4 8 6 M, knm 6-6 - S-H-- S-H-- -8 S-HD-- -4 - -6 - -8-4 4 8 6 Curvature, rad/km a. b. Figure 4. Envelope responses for: a. Lateral load vs. Deflection b. Moment vs. Curvature APFIS 7 97

5 - -5 - - 5 - -5 - - S-H-- - - - S-HD-- -5-4 - - - 4 5 5 - -5 - - 5 - -5 - - S-H-- - - - Damage - - - 5 - -5 - - 5 - -5 - - S-HD-- Damage - - - Figure 5. Strain gage responses of specimens with damage cycles. -5-4 - - - 4 5 SUMMARY AND CONCLUSIONS Results from an experimental study, in which four columns were tested under constant axial load and cyclic lateral displacement excursions that simulated seismic forces, are presented in this study. Each column had dimensions of 5 5 mm cast vertically together with a stub of 4 5 5 mm that represented a typical near full scale building column. Three specimens representing the strengthened and repaired columns were retrofitted with layer of CFRP sheet. Other column was termed as reference column as it represented a deficient building column that had plain longitudinal bars, insufficient transverse reinforcement and relatively low concrete compressive strength. The effect of CFRP confinement and presence of axial load during repairing were studied. The following conclusions can be drawn from this study:. layer of CFRP sheet used to confine the plastic hinge regions of the columns significantly improved the seismic behaviour of the deficient columns by improving the ductility and the energy dissipation capacity of the columns.. The energy dissipation capacities of the repaired columns were lower than the strengthened column due to the initial cracks that formed during the application of the moderate level of previous damage.. The presence of axial load level of 7% of the capacity during repairing had almost no influence on the ultimate drift and ductility of the columns. The repaired columns behaved in a similar manner with the strengthened column. On the contrary, the lateral load carrying capacity increased by 5% of the reference column in the absence of the axial load during repairing. This fact was due to the higher compressive strength of the epoxy mortar compared to the existing compressive strength of concrete that influenced the section capacity in the absence of axial load. When the axial load was present there was no gain in the lateral capacity of the column. In this case, the section capacity was not affected since the axial load was not perceived by the epoxy mortar repair section of the column. REFERENCES Haroun, M.A. and Elsanadedy, H.M., (). Behavior of Cyclically Loaded Squat Reinforced Concrete Bridge Columns Upgraded with Advanced Composite-Material Jackets, Journal of Bridge Engineering, ASCE, November December, 74-748. Iacobucci, R.D., Sheikh, S.A. and Bayrak, O. (). Retrofit of Square Concrete Columns with Fiber- Reinforced-Polymer for Seismic Resistance, ACI Structural Journal, -S8, 785-79. Seible, F., Priestley, M.J.N., Hegemier, G.A. and Innamorato, D. (997). Seismic Retrofitting of RC with Continuous Carbon Fiber Jackets, Journal of Composites for Construction, May, 5-6. Sheikh, S.A. and Yau, G. (). Seismic Behavior of Concrete Columns Confined with Steel Reinforced Polymers, ACI Structural Journal, 99-S8, 7-8. APFIS 7 98